• Title/Summary/Keyword: heart valve

Search Result 819, Processing Time 0.024 seconds

Reoperations on Heart Valve Prostheses (인공심장판막에 대한 재치환술)

  • 김재현;최세영;유영선;이광숙;윤경찬;박창권
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1165-1171
    • /
    • 1998
  • Background: All currently available mechanical and bioprosthetic valves are associated with various types of deterioration leading to dysfunction and/or valvular complications. Reoperation on prosthetic heart valves is increasingly under consideration for both clinical and prophylactic indications. This review was conducted to determine the factors affecting the risk of reoperation for prosthetic valve replacement. Material and method: From January 1985 to July 1996, 124 patients underwent reoperation on prosthetic heart valves, and 3 patients had a second valve reoperation. The causes of reoperation were prosthetic valve failure(96 cases, 77.4%), prosthetic valve thrombosis(16 cases, 12.9%), prosthetic valve endocarditis(7 cases, 5.6%) and paravalvular leak(5 cases, 4.1%). This article is based on the analysis of the experience with particular emphasis on the preoperative risks affecting the outcome of the reoperation. Result: Overall hospital mortality rate was 8.9%(11/124). Low cardiac output was the most common cause of death(70.6%). Left ventricular systolic dimension(p=0.001), New York Heart Association functional class IV(p=0.003) and serum creatinine level(p=0.007) were the independent risk factors, but age, sex and cardiothoracic ratio did not have any influence on the operative mortality. Follow-up period was ranged from 3 to 141 months (mean, 50.6 months). A late mortality rate was 1.8%. Conclusion: The surgical risk of reoperation on heart valve prostheses in the advanced NYHA class patients is higher, therefore reoperation is recommended before the hemodynamic impairment become severe.

  • PDF

Trends in Heart Valve Surgery in Korea: A Report from the Heart Valve Surgery Registry Database

  • Choi, Jae Woong;Kim, Joon Bum;Jung, Yoo Jin;Hwang, Ho Young;Kim, Kyung Hwan;Yoo, Jae Suk;Lee, Sak;Lee, Seung Hyun;Sung, Kiick;Je, Hyung Gon;Lim, Mi Hee;Chang, Byung-Chul;Hong, Soon Chang;Lee, Heemoon;Shin, Yoon Cheol;Kim, Jae Hyun;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.55 no.5
    • /
    • pp.388-396
    • /
    • 2022
  • Background: In this study, we present recent trends in heart valve surgery in Korea through analyses of data from the Korea Heart Valve Surgery Registry (KHVSR). Methods: We enrolled 8,981 patients who were registered in the KHVSR from 2017 to 2020. Yearly trends in patients' baseline characteristics, surgical profiles, and early mortality rates were explored. The observed/expected mortality ratio (O/E ratio), calculated from the actual mortality in the KHVSR and the predicted mortality estimated using the EuroSCORE II, was also analyzed. Results: The proportion of aortic valve surgery significantly increased from 56.8% in 2017 to 60.3% in 2020. The proportion of all combined procedures and minimally invasive surgery significantly increased over the 4-year study period. The operative mortality rate was 2.9% in the entire cohort, while mitral valve repair showed the lowest mortality risk (0.9%). The mortality rates of isolated aortic valve replacement (AVR) significantly decreased from 2.1% in 2017 to 0.8% in 2020 (p=0.016). Overall, the O/E ratio was 0.784 (95% confidence interval [CI], 0.677-0.902) demonstrating significantly lower actual mortality risks than expected based on the EuroSCORE II. In particular, the O/E ratios were as low as 0.364 (95% CI, 0.208-0.591) for isolated AVR. Conclusion: The recent data from the KHVSR showed increasing trends for complex procedures and minimally invasive surgery in heart valve surgery in Korea, and demonstrated remarkably low risks of operative mortality.

Heart Valve Stenosis Region Detection Algorithm on Heart Sounds (심음에서의 심장판막협착 영역 검출 알고리듬)

  • Lee, G.H.;Lee, Y.J.;Kim, M.N.
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.11
    • /
    • pp.1330-1340
    • /
    • 2012
  • In this paper, a new algorithm is proposed for the heart valves stenosis region detection using heart sounds. Many researches for detecting primary components or removing heart murmurs have been studied, but their performances are degraded at abnormal heart sounds such as aortic stenosis and mitral stenosis because of large heart murmurs. In this paper, heart murmur detection method is proposed based on noise intensity function. The proposed noise intensity function detect the primary components S1, S2, then set session up using S1, S2. And then noise intensity function was computed using autocorrelation value of each session. The proposed noise intensity function estimated noise intensity of each sessions and detected heart murmurs. According to simulation results, the proposed algorithm has better performance than former study for detecting heart valve stenosis region.

Mitral Valve Replacement : A Report of 238 cases (승모판막 대치이식술 238예 보고)

  • Lee, Yung-Kyoon;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.422-434
    • /
    • 1980
  • Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.

  • PDF

Assessment of Hemodynamic Properties of Trileaflet Polymer Heart Valve Manufactured By Vacuum Forming Process (진공성형을 이용한 삼엽식 고분자 심장판막의 제작과 혈류역학적 성능평가)

  • Kim, K.H.;Hwang, C.M.;Jeong, G.S.;Ahn, C.B.;Kim, B.S.;Lee, J.J.;Nam, K.W.;Sun, K.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.418-426
    • /
    • 2006
  • In the artificial heart application, productivity and hemodynamic properties of artificial heart valves are crucial in successiful application to long term in vivo trials. This paper is about manufacture and assessment of trileaflet polymer heart valves using vacuum forming process(VFP). The VFP has many advantages such as reduced fabrication time, reproducibility due to relatively easy and simple process for manufacturing. Prior to VFP of trileaflet polymer heart valves, polyurethane(Pellethane 2363 80AE, Dow Chemical) sheet was prepared by extrusion. The sheets were heated and formed to mold shape by vacuum pressure. The vacuum formed trileaflet polymer heart valves fabrication is composed of two step method, first, leaflet forming and second, conduit forming. This two-step forming process made the leaflet-conduit bonding stable with any organic solvents. Hydrodynamic properties and hemocompatibility of the vacuum formed trileaflet polymer heart valves was compared with sorin bicarbon bileaflet heart valve. The percent effective orifice area of vacuum formed trileaflet polymer heart valves was inferior to bileaflet heart valve, but the increase of plasma free hemoglobin level which reflect blood damage was superior in vacuum formed trileaflet polymer heart valves Vacuum formed trileaflet polymer heart valves has high productivity, and superior hemodynamic property than bileaflet heart valves. Low manufacturing cost and blood compatible trileaflet polymer heart valves shows the advantages of vacuum forming process, and these results give feasibility in in vivo animal trials in near future, and the clinical artificial heart development program.

Early and Late Results after Mitral Valve Replacement (승모판막 치환후 조기및 장기추적결과)

  • 김명인
    • Journal of Chest Surgery
    • /
    • v.25 no.2
    • /
    • pp.149-157
    • /
    • 1992
  • Total 145 cases mitral vlave replacement were performed in Department of Thoracic and Cardiovascular Surgery in Chungnam National University Hospital during the period from May 1983 to July 1991. Sixty-one patients were male and 84 patients were female and the range of age was from 12 to 66 years old with the mean of 37.9[$\pm$11.6] years. Valvular lesions were 49 cases of mitral stenosis, 18 cases of regurgitation and 78 cases of combined lesion. Used valve were Ionescu-Shiley[42 cases], Bjork-Shiley[49 cases], Inact[6 cases], St. Jude Medical[11 cases] and CarboMedics[37 cases]. Mean size of valve was 29.8$\pm$1.68mm. Early morality was 13.8%[20 cases] and low output syndrome was most common cause[9 cases]. Age, functional classification and biventricular hypertrophy were risk factors. All survived cases were followed up without missing. Mean follow up period were 3 years and 3 months. Total 14 cases of death[9.7%] were observed and heart failure, unexplained sudden death and bleeding were the causes in that order. Common late complications were heart failure and bleeding related with anticoagulation. Actuarial survival rate at 5 years was 83$\pm$5.4% in overall, 78$\pm$7.2% in tissue valve group, 87$\pm$6.8% in mechanical valve group. The actuarial freedom rate from thromboembolism at 7 years was 89$\pm$8.3% in overall, 86$\pm$9.9% in tissue valve group and 97$\pm$1.9% in mechanical valve group. Actuarial freedom rate from bleeding at 5 years with anticoagulation was 88.9$\pm$4.2% in overall, 96$\pm$3.9% in tissue valve group, 86$\pm$4.6% in mechanical valve group. Reoperation was done in 3 cases with heart failure with tricuspid regurgitation and thromboembolism in 2 cases. The functional status of survived cases was I or II.

  • PDF

4D flow MRI based flow visualization and quantification of bicuspid valvular flow using ex-vivo porcine model (4차원 자기공명영상을 활용한 돼지 심장 ex-vivo 이첨판 모델 유동 가시화 및 유동 특성 분석)

  • Minseong Kwon;Sungho Park;Hyungkyu Huh
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.12-17
    • /
    • 2023
  • Aortic valve stenosis is a heart valve disease caused by the accumulation of calcium in the valve, which can divide into tricuspid aortic valve (TAV) stenosis and bicuspid aortic valve (BAV) stenosis depending on the shape of natural valve. In this study, pig heart-based TAV and BAV ex vivo models were fabricated, and the flow characteristics behind a valve were analyzed using 4D flow MRI. Flow behind normal TAV was uniformly distributed, while BAV asymmetrically opened with an eccentric strong jet. Especially, BAV ex vivo model exhibited a secondary flow in the region where the valve closed. In addition, BAV had a 26% higher peak velocity while maintaining similar stroke volume compared with normal TAV. This study would be helpful for understanding the flow characteristics for BAV AS patients.

Dynamic Behavior Analysis of the Heart Valve Prostheses Considering Squeeze Film Effect During Closing Phase (스퀴즈필름효과를 고려한 인공심장밸브의 닫힘시 동적거동 해석)

  • 천길정
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.443-450
    • /
    • 1995
  • An analysis of the dynamics of a mechanical monoleaflet heart valve prosthesis in the closing phase is presented. Employing the moment equilibrium principles on the occluder motion and the squeeze film dynamics of the fluid between the occluder and the guiding strut at the instant of impact, the velocity of the occluder tip and the impact force were computed. The dynamics of fluid being squeezed between the occluder and the guiding struts is accounted for by Reynold's equation. The effect of the fluid being squeezed between the occluder and the guiding strut was to reduce the velocity of the occluder tip at the instant of valve closure as well as dampen the fluttering of the occluder before coming to rest in the fully closed position. The squeeze film fluid pressure changed rapidly from a high positive value to a relatively large negative value in less than 1 msec. The results of this study may be extended for the analysis of cavitation inception, mechanical stresses on the formed elements and valve components as well as to estimate the endurance limits of the prosthetic valves.

Reoperations for valvular heart disease: report of 29 cases (심장판막 재수술: 29례 보)

  • 김은기
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.498-505
    • /
    • 1983
  • It has been over 20 years since successful operations of Cardiac valves at the Department of Thoracic and Cardiovascular surgery, college of medicine, Yonsei University. About six hundreds of patients with severely symptomatic valvular heart disease have had valve operations with complete loss or sharp decrease in their cardiac symptoms since 1956. As the number of cardiac patient increases, reoperation on valves assumes greater importance. To define the group of patients undergoing reoperations on valves and the factors influencing their survival, we have reviewed our experiences of the reoperation on valves at the Yonsei University, Severance Hospital. This is a report of 29 cases which was undergone secondary or more surgery for valvular heart disease from 1966 to 1983. The primary operations includes 159 cases of open heart surgery from 1966 to 1975 and 476 cases from 1976 to march, 1983. The secondary operations are classified into groups of secondary valvuloplasty or valvotomy [8 cases], prosthetic valve replacement following valvuloplasty or valvotomy [14 cases] and prosthetic valve rereplacement [2 case] for such as calcification, degeneration and perforation of the cusps and paravalvular leakage, of the bioprosthetic valves. The leading indication for reoperation of mitral valve was restenosis or stenoinsufficiency, The indications of aortic valve replacement was active bacterial endocarditis, medically uncontrollable prosthetic endocarditis or paravalvular leakage. Overall death rate of the reoperation was 17.4% [5 death among the 29 patients] and the leading causes of death were myocardial failure, arrhythmia, cerebral embolism, acute renal failure due to low output syndrome. And it was followed by sepsis associated with active prosthetic endocarditis. The death rate of reoperation was 4.3% in the elective cases except urgent cases and the death rate of overall cardiac valve except reoperation cases was 4.1% in the last two years. Although the general mortality of reoperation was high, both mortality rates were comparable except emergency cases due to urgent preoperative patient’s condition.

  • PDF

The Effect of Compliance Structures Near the Mechanical Heart Valve on Valve Surface Erosion (기계식 인공 판막 주위의 유연성 구조가 표면 괴식에 미치는 영향)

  • Lee, Hwan-Sung;Hwang, Sung-Won;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.309-315
    • /
    • 2002
  • Since the discovery, in the 1980s, of erosion-pit-induced fractures in implanted mechanical heart valves. cavitation on the surface of mechanical heart valves has been widely studied as a possible cause of pitting. Several factors, including peak dp/dt of the ventricular pressure. maximum closing velocity of the leaflet, and squeeze flow. have been studied as indices of the cavitation threshold. In the present study. cavitation erosion on the surface of a mechanical valve was examined by focusing on squeeze flow and the water hammer phenomenon during the closing period of the valve. In this study, we measures pressure wave forms near a valve and closing velocities of a disk, which were placed in a holder with and without compliance. In case of all holders, pressure drop of below vapor pressure expect at near the surface disk. It was also found that the closing velocity of the disk increased and that cavitation erosion was enhanced too. These results suggest that disk closing velocity during the closing phase has signifiant effects on pitting erosion.