• 제목/요약/키워드: heart function

검색결과 1,136건 처리시간 0.026초

관통성 심장 자상 환자의 응급수술 (Emergency Treatment of Penetrating Cardiac Injury)

  • 신윤곤
    • Journal of Chest Surgery
    • /
    • 제27권6호
    • /
    • pp.483-485
    • /
    • 1994
  • Recently, we experienced one case of penetrating cardiac injury patient by the knife.This patient was treated by emergency operation through left anterolateral thoracotomy under local anesthesia at emergency room. But, the patient was brought about the brain death inspite of normalized function of heart and lung. Now we have a conclusion that was able to recover of heart and lung functions by doctor`s exactly judgement and practice, at least.

  • PDF

Application of Artificial Intelligence to Cardiovascular Computed Tomography

  • Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1597-1608
    • /
    • 2021
  • Cardiovascular computed tomography (CT) is among the most active fields with ongoing technical innovation related to image acquisition and analysis. Artificial intelligence can be incorporated into various clinical applications of cardiovascular CT, including imaging of the heart valves and coronary arteries, as well as imaging to evaluate myocardial function and congenital heart disease. This review summarizes the latest research on the application of deep learning to cardiovascular CT. The areas covered range from image quality improvement to automatic analysis of CT images, including methods such as calcium scoring, image segmentation, and coronary artery evaluation.

하퇴 절단 환자의 족부 종류에 따른 심폐 기능의 비교 (A Comparison of Cardio-Pulmanary Function by the use of a Single Axis Foot and SACH Foot in Below-Knee Amputation)

  • 안왕훈;김영희
    • 대한물리치료과학회지
    • /
    • 제7권1호
    • /
    • pp.311-319
    • /
    • 2000
  • This study was to measure whether single axis foot or the SACH foot applied to below-knee amputation patients would bring positive changes to the patients' cardiopulmonary function, and help them to overcome their disability. The experiment took place at Asan Medical Center, University of Ulsan, from July 20th to November 20th, 1999 with 10 below-knee amputation patients. The patients were asked to equip single axis foot and SACH foot by turns and lead them to walk on a treadmill which was designed to increase its steep slope. Patients heart rate and blood pressure were recorded before and after their walking, The heart rate, systolic blood pressure, diastolic blood pressure of the patients who were equipped with, either SACH foot or single axis foot, have been increased with as the slant becoming steeper. The heart rates during the experiment did not show relevant changes according to the kind of foot used and the gradient, but the changes occurred before and after the walking(p=0.0001), The similar result of systolic blood pressure was found during the waking(p=0.01). Below-knee amputation patients are expected to walk and perform the routines better, no matter what type of foot is used, as long as they wear an artificial foot properly and taking features of foot product into consideration

  • PDF

여성의 무증상 갑상샘 기능이상과 관상동맥질환 발생과의 관련성 연구 (A Study of Subclinical Thyroid Function Disorder and the Risk of Coronary Heart Disease in Women)

  • 염순교;박재순
    • 성인간호학회지
    • /
    • 제22권1호
    • /
    • pp.80-89
    • /
    • 2010
  • Purpose: This paper has attempted to investigate the association between the subclinical thyroid function disorder caused by natural change in thyroid hormones or thyroid remedies and the incidence of CHD. Methods: Data was analyzed of 7,675 women who had undergone health examinations in a hospital in Gyeonggi-do between January 2007 and December 2008. The covariation of the coronary risk factors such as age, BMI, HbA1C, systolic blood pressure, LDL:HDL-cholesterol ratio, CRP, smoking and exercise were analyzed by using logistic regression analysis. Results: A significant increase in serum TSH was observed with higher age (F=26.91, p=.00). In terms of age, the risk of CHD started to gradually increase since the 40s and sharply since the 60s (${\chi}^2$=113.29, p=.00). The serum TSH was the most significant parameter influencing CHD (B=.12, p=.00). The risk of coronary heart disease was 3.12 times higher in the subclinical hypothyroidism group (OR=3.12) while no significant difference was observed in the subclinical hyperthyroidism group. Conclusion: Subclinical hypothyroidism may be an independent risk factors for CHD. A nurse nursing patients with thyroid disorder should be well informed of their state of subclinical thyroid function disorder and make efforts to extend their health expectancy.

Wearing of a Whole-Body Compression Garment Can Enhance Exercise Efficiency

  • Jeon, Su-Jeong;Jung, Yu-Jin;Lee, Eun-Jae;Choi, Ji-Hye;Jung, Dongju
    • 대한의생명과학회지
    • /
    • 제27권2호
    • /
    • pp.88-94
    • /
    • 2021
  • A whole-body compression garment (WBCG) is mainly used for cosmetic purpose in Korea. Another case for wearing the WBCG would be while exercising because it allows the body to move easily. But physiological effects of wearing WBCG to the body have not been known much. To investigate whether wearing WBCG would be helpful for conducting exercises, we measured physiological criteria, which could be influenced by the compression, such as cardiovascular and pulmonary function. Twelve female college students participated in this experiment. Increase of blood pressure was monitored in all of the participants when they wore a WBCG just for 10 minutes. Pulmonary function that requires skeletal muscle contraction was decreased by wearing a WBCG. Blood pressure measured after conducting exercise became even lower when wearing a WBCG than non-wearing. Interestingly, heart pulse remained lower when wearing a WBCG than non-wearing during the whole relaxing period after the exercise. Electrocardiogram (ECG) analyses showed that such lower heart rate largely depended on extension of QT time. For that reason, physiological efficiency index (PEI) was higher for wearing WBCG. These results indicate wearing WBCG could enhance exercise efficiency by lowering heart pulse.

Urokinase의 적출심장의 심근허혈에 대한 보호작용과 invitro 및 exvivo항혈전작용 실험 (Protective Effect of Urokinase on Reperfusion Function in Isolated Perfused Rat Heart, and Anti-platelet Aggregation Effect Invitro and Exvivo)

  • 권광일;신흥섭;윤정옥;김보신;민지하;이병호;허인회
    • 한국임상약학회지
    • /
    • 제2권1호
    • /
    • pp.1-9
    • /
    • 1992
  • Protective effect of urokinase on reperfusion were studied followed by global ischemia in the isolated perfused rat heart. Separately, anti-platelet aggregation effect of urokinase also investigated. Urokinase exhibited positive effect for the protection of rat heart function by increasing the LV dp/dt, coronary flow(CF) and the Tate pressure product(RPP), and by decreasing the LVEDP on reperfusion. Urokinase also decreased arrhythmia by $74.7\%(P<0.05) induced by global ischemia in the rat heart. In the platelet aggregation study, urokinase did not show the inhibitory effect of ADP or collagen induced platelet aggregation inviuo and exvivo.

  • PDF

$^{99m}Tc-DISIDA$ 스캔에 의한 간기능의 정량적 평가 (Quantitative Evaluation of Liver Function Using $^{99m}Tc-DISIDA$ Cholescintigraphy)

  • 김창근;김병찬;정영선;원종진;이정균
    • 대한핵의학회지
    • /
    • 제22권2호
    • /
    • pp.181-185
    • /
    • 1988
  • Since hepatocyte clearance, leading edge parencymal transit time and biliary excretion can be evaluated separately with hepatobiliary scan using $^{99m}Tc-DISIDA$, hepatobiliary scan may be useful in differentiating intrahepatic cholestasis from extrahepatic cholestasis. Excretory liver function was analysed in 13 healthy subjects and 11 patients with clinically suspected hepatocellular disease and 9 patients with extrahepatic biliary obstruction confirmed by surgery, radiological and clinical evidence. Indices of total liver activity (% TLA), liver parechymal uptake (% LPU), heart pool clearance (% HPC) and liver-heart rate (% LHR) were calculated from time activity curve over heart and liver. Compared with healthy subjects, significant reduction (p<0.05) in total liver activity (% TLA) and liver-heart rate (% LHR) was observed in all patients group. But no useful indices was demonstrated in differentiating hepatocellular disease from extrahepatic biliary obstruction.

  • PDF

Assessment of the Cardioprotection Offered by Fisetin in H2O2-induced Zebrafish (Danio rerio)-Tg (cmlc2: egfp)

  • Lee, Jeong-Soo;Park, Eun-Seok;Kim, In-Sik
    • 대한의생명과학회지
    • /
    • 제24권2호
    • /
    • pp.130-133
    • /
    • 2018
  • The aim of this study was to evaluate the protective function of fisetin, a natural flavonoid in zebrafish heart for the treatment of myocardial infarction in coronary and ischemic heart disease. For this purpose, we induced oxidative stress zebrafish (Danio rerio)-Tg (cmlc2: egfp) by $H_2O_2$ and then administered fisetin, the protective effect of fisetin was determined by measuring the heart rate following fisetin administration. After testing the toxicity of fisetin, we found that the heartt increased in a concentration-dependent manner, however there was no difference between the heart rates of embryos and adults. The improved heart rate demonstrated the cardioprotective effect of fisetin. The result showed that fisetin, at concentration of 3and $5{\mu}M$, significantly increased heart rate compared with the heart with $H_2O_2$ alone. This indicates that fisetin plays an important role in the prevention of heart damage and treatment of cardiovascular diseases caused by oxidative stress due to ischemia / reperfusion.

심실의 부하감소 측면에서 좌심실 보조장치의 최적 치료시기 예측을 위한 시뮬레이션 연구 (Prediction of Pumping Efficacy of Left Ventricular Assist Device according to the Severity of Heart Failure: Simulation Study)

  • 김은혜;임기무
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.22-28
    • /
    • 2013
  • It is important to begin left ventricular assist device (LVAD) treatment at appropriate time for heart failure patients who expect cardiac recovery after the therapy. In order to predict the optimal timing of LVAD implantation, we predicted pumping efficacy of LVAD according to the severity of heart failure theoretically. We used LVAD-implanted cardiovascular system model which consist of 8 Windkessel compartments for the simulation study. The time-varying compliance theory was used to simulate ventricular pumping function in the model. The ventricular systolic dysfunction was implemented by increasing the end-systolic ventricular compliance. Using the mathematical model, we predicted cardiac responses such as left ventricular peak pressure, cardiac output, ejection fraction, and stroke work according to the severity of ventricular systolic dysfunction under the treatments of continuous and pulsatile LVAD. Left ventricular peak pressure, which indicates the ventricular loading condition, decreased maximally at the 1st level heart-failure under pulsatile LVAD therapy and 2nd level heart-failure under continuous LVAD therapy. We conclude that optimal timing for pulsatile LVAD treatment is 1st level heart-failure and for continuous LVAD treatment is 2nd level heart-failure when considering LVAD treatment as "bridge to recovery".

Carbomedics 인조 심장판막의 임상적 경험 (Clinical Experience of Carbomedics Prosthetic Heart Valve)

  • 전상협;김종원
    • Journal of Chest Surgery
    • /
    • 제28권9호
    • /
    • pp.817-821
    • /
    • 1995
  • The CarboMedics Medical valve has become our mechanical valvular prosthesis of choice because of favorable hemodynamic results that associated with marked clinical improvement and low incidence of thromboembolism after it,s uses. The data for this study was collected from August 1988 to July 1993,five years period. There were total of 57 patients[female 40,male 17 in this series with 4 isolated aortic valve,26 isolated mitral valve,11 double valve and a triple valve replacement. The mean follow up time was 32 months. Postoperatively,58% of cases were in New York Heart Association[NYHA functional class I,and mild and moderate symptoms[NYHA class II were present in 36% and there were very few patients remaining in higher functional classes. In postoperative echocardiographic study, showed marked improved cardiac function. The overall early mortality was 3.5% and the late mortality was one case after triple valve replacement due to sudden death. The causes of early death were attributed to early prosthetic valve endocarditis and heart failure.

  • PDF