• 제목/요약/키워드: healing temperature

검색결과 134건 처리시간 0.042초

A Model-Based Fault Detection and Diagnosis Methodology for Cooling Tower

  • Ahn, Byung-Cheon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.63-71
    • /
    • 2001
  • This paper presents a model-based method for detecting and diagnosing some faults in the cooling tower of healing, ventilating, and air-conditioning systems. A simple model for the cooling tower is employed. Faults in cooling tower operation are detected through the deviations in the values of system characteristic parameters such as the heat transfer coefficient-area product, the tower approach, the tower effectiveness, and fan power. Three distinct faults are considered: cooling tower inlet water temperature sensor fault, cooling tower pump fault, and cooling tower fan fault. As a result, most values of the system characteristics parameter variations due to a fault are much higher or lower than the values without faults. This allows the faults in a cooling tower to be detected easily using above methods. The diagnostic rules for the faults were also developed through investigating the changes in the different parameter due to each faults.

  • PDF

오피스 휴게공간에서 자연요소의 심리적 효과에 관한 연구 (A Study on Psychological Effect of Natural Element in Rest Space of Office)

  • 강민경;류호창
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.84-87
    • /
    • 2004
  • The stress from the office environment comes from the most psychological things. Therefore, the purpose of this study is to research the psychological effect of natural element for office worker's psychological stability. This study is focused on the light, sound, air, temperature, plant, and water. Perception of these natural elements through the senses of sight, auditory, smell, and touch is effect on human body and mind directly. The application of natural elements provide a health of office workers. The result will show that, with application of the natural element, the rest space will be more powerful for health of workers. And also combination of natural element and geometric pattern will be very useful to prepare healing environment on the rest space

  • PDF

A Study on Flow Properties of Semisolid Dosage Forms

  • Shon, Sung-Gil;Lee, Chi-Ho
    • Archives of Pharmacal Research
    • /
    • 제19권3호
    • /
    • pp.183-190
    • /
    • 1996
  • There are a wide variety of semi-solid ointments used for healing the skin diseases, whose therapeutic and skin penetration abililties may greatly differ from one another depending on the compositions of ointment vehicles. A computer optimization technique was applied to obtain the optimum formula of o/w type ointment giving the in vitro maximum absorption rate through hairless rat skin membrane. Some of the formulations were selected to find out a relationship between skin penetration of ointment and its Theological characteristics. The experimental value of absorption rate obtained from the ointment by optimum formula agreed well with the theoretical value obtained from a polynomial regression analysis, Three kinds of ointments selected among 15 formulations were obtained with a concentric cylinder type rheometer (Model; Rheolab SM-HM Physica, Germany) at 20, 30, 40 and $50^{\circ}C$ for rheograms of rhelolgical properties of o/w type ointments. As the temperature was raised, all products showed a decrease in both shear stress and yield values. The higher skin penetration, the lower shear stress showed.

  • PDF

플라스틱 기판을 이용한 in-situ 광배향법에 의한 액정배향 효과 (Liquid Crystal Alignment Effect with in-situ Photoalignment on Plastic Substrates)

  • 황정연;남기형;김종환;김강우;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.80-83
    • /
    • 2003
  • We have investigated the generation of pretilt angle for a nematic liquid crystal (NLC) alignment with in-situ photoalignment method on polyimide (PI) surfaces using thin plastic substrates. The LC aligning capabilities and pretilt angle of the thin plastic substrates by in-situ photoalignment method were better than that of the glass substrate by general photoalignment. Also, the LC pretilt angle increased with increasing healing temperature and exposure time.

  • PDF

경피적 동맥확장술을 이용한 당뇨족 허혈의 치료 (Treatment of Vasculopathy in Diabetic Foot by Percutaneous Transluminal Angioplasty)

  • 김홍렬;한승규;나승운;김현석;김우경
    • Archives of Plastic Surgery
    • /
    • 제37권2호
    • /
    • pp.148-152
    • /
    • 2010
  • Purpose: In treating diabetic foot ulcers, satisfactory vascularity is an essential prerequisite. To improve vascularity, a bypass graft has long been carried out. Recently, however, percutaneous transluminal angioplasty (PTA) has also been tried since the PTA is less invasive than the bypass graft. However, publication demonstrating the improvement of vascularity after the PTA are lacking. Therefore, this study was designed to show usefulness of the PTA in treating vasculopathy of diabetic foot. Materials: and Methods This study included 30 feet of 24 ischemic diabetic foot patients. Inclusion criteria were diabetes (duration > 5 years) and a significant lower extremity ischemia, as determined by a transcutaneous oxygen pressure ($TcpO_2$) < 30 mmHg. The PTA was carried out in 61 arteries. PTA procedure was considered successful, when residual stenosis was less than 30%. The procedure was considered failed when residual stenosis was more than 50%. Residual stenosis between 30% and 50% was considered acceptable. For evaluation of PTA effect, foot $TcpO_2$ and infrared thermography were measured before and 7th day after PTA. Results: Immediately after PTA performed in 61 arteries, 58 and 3 arteries were evaluated as being successful and acceptable, respectively. Before PTA, average foot $TcpO_2$ was $12.6{\pm}8.8$ mmHg and its value was increased to $44.2{\pm}23.9$ on 7th day after PTA (p<0.01). Average skin temperature was $31.8{\pm}1.2^{\circ}C$ before PTA and it was increased to $33.5{\pm}1.1^{\circ}C$ on 7th day after PTA (p<0.01). Conclusion: PTA procedure increases tissue oxygenation of ischemic diabetic feet which do not have wound healing potential due to low tissue oxygenation, to the level of possible wound healing. In addition, PTA increases skin temperature of ischemic diabetic feet which can imply an improvement of peripheral circulation.

산림휴양지 유형에 따른 피톤치드(모노테르펜) 농도 비교 (Comparison of Phytoncide (monoterpene) Concentration by Type of Recreational Forest)

  • 이용기;우정식;최시림;신은상
    • 한국환경보건학회지
    • /
    • 제41권4호
    • /
    • pp.241-248
    • /
    • 2015
  • Objectives: This study was conducted to provide scientific and effective information on phytoncides, which are associated with forest healing, and to activate recreational forests. Methods: The target sites were natural recreation forests, a forest park and an arboretum, and the control sites were three urban parks. The samples were collected at a volume of 6.0 L and a flow rate of 0.1 L/min for one hour using a low volume pump and the solid adsorbent sampling method. The phytoncide compounds adsorbed in the Tenax TA tube were analyzed by a automatic heat desorption unit and GC-MS. Results: By type of recreational forest, the annual concentrations of phytoncide (monoterpene) for the forest park showed the highest concentration with $1.450{\mu}g/m^3$, while those for the arboretum showed the lowest concentration at $0.892{\mu}g/m^3$, and thus the concentration of the forest park was approximately 1.6 times higher than the arboretum. The season showing the highest concentration of phytoncides was summer (June) and the forest park was the highest among the recreational forests. The concentrations of major components for phytoncide showed in descending order: ${\alpha}-pinene$, ${\beta}-pinene$, camphene, 3-carene and limonene. The seasonal concentration of ${\alpha}-pinene$, camphene and ${\beta}-pinene$ by type of recreational forest increased in April, which is characterized by low temperature and humidity, and the seasonal concentration of camphene decreased with higher humidity. The meteorological factors which had the high correlation with the concentration of total terpene were temperature and humidity. $CO_2$ and $O_2$ showed an inverse correlation. Conclusion: The major components of phytoncide were ${\alpha}-pinene$, ${\beta}-pinene$, camphene, 3-carene and limonene in descending order of concentration. Further and systematic study on the chemical nature of individual phytoncides, and on the effect of phytoncides on humans needs to be performed.

다양한 조성의 혼용 폴리올에 기초한 접착력 및 굴곡성이 향상된 자외선 경화형 폴리우레탄 접착제의 합성 (Synthesis of UV Curable Polyurethane Adhesives Based on Various Compositions of Mixed Polyol with Improved Adhesion and Flexural Properties)

  • 이원영;박수용;김구니;정일두
    • 접착 및 계면
    • /
    • 제23권4호
    • /
    • pp.137-143
    • /
    • 2022
  • 본 연구에서는 신발 및 의류용 접착제로 접착력과 굴곡성이 우수한 폴리우레탄 아크릴레이트 수지를 합성하기 위하여 폴리에스테르 폴리올인 poly(tetramethylene adiphate glycol) (PTAd)와 폴리에테르 폴리올인 poly(tetramethylene ether glycol) (PTMG)를 4,4'-methylene diphenyl diisocyanate (MDI), isophorone diisocyanate (IPDI), 1,4-butandiol (1,4-BD), 2-ydroxyethyl methacrylate (2-HEMA), dibutyl amine (DBA)와 함께 사용하여 폴리우레탄 아크릴레이트를 합성하였으며, 폴리올을 병용한 폴리우레탄 아크릴레이트의 열적·기계적 특성, 접착력 및 굴곡성을 검토하였다. 합성된 폴리우레탄 아크릴레이트의 유리전이온도는 -70~-40 ℃ 범위로 확인되었으며, PTAd 함량이 증가함에 따라 유리전이온도, 분해온도, 인장강도, 접착력 및 내열성이 증가하였고 반대로 신장률, 내수성 및 굴곡성은 감소되었다. 합성된 폴리우레탄 아크릴레이트는 PTAd와 PTMG 비율이 5:5일 때 높은 접착력과 굴곡성을 나타내었다.

Correlation of the 2223 percentage before the first intermediate pressing and the transport property of the fully processed Bi-2223/Ag tapes

  • Jiang, C.H.;Yoo, J.M.;Ko, J.W.;Kim, Y.K.;Chung, H.S.
    • Progress in Superconductivity
    • /
    • 제4권1호
    • /
    • pp.94-98
    • /
    • 2002
  • Two kinds of multifilament Bi-2223/Ag tapes, which are different in the precursor calcination temperatures, were heat treated for different time (12, 20, 30, 50, 70, or 100 h) firstly to obtain varied B2223 contents, and then followed by the same pressing and sintering cycles. The relation of the 2223 phase contents after the first sintering and the transport property of the fully processed tapes was studied. The results show that 75-80% 2223 phase formed in tapes before the first cold pressing is beneficial to get a high $I_{c}$ in the final tapes. Compensating the total heat treatment time of the tapes first sintered for 20 h to the same length as that first sintered for 50 h in the subsequent sintering stages, different $I_{c}$ enhancements were observed in these two tapes. No improvement on $I_{c}$ was found in the tape made from the powder calcined at higher temperature, whereas for the tape prepared with the lower temperature calcined powder, the $I_{c}$ was increased to the same level as that first sintered for 50 h. The 2223 contents before the intermediate mechanical work is related to the residual reactants, especially to the liquid phase, which is of vital importance to the phase conversion and healing microcracks, meanwhile, to the size and distribution of the non-superconducting secondary phases. The lower temperature calcined powder resulted in slow formation of 2223 phase, but also provided more reactants and liquid phase for the further phase conversion, as a consequence, for the Improvement of $I_{c}$. c/.

  • PDF

SIS-SBS 개질아스팔트 방수시트재 물성 최적화 (Optimization to Prepare SIS-SBS Modified Asphalt for Waterproof-sheet)

  • 임광희
    • Korean Chemical Engineering Research
    • /
    • 제55권5호
    • /
    • pp.690-697
    • /
    • 2017
  • 본 연구에서는 방수시트재를 위한 아스팔트의 styrene-butadiene-styrene (SBS)와 styrene-isoprene-styrene (SIS)에 의한 개질에 있어서 자가치유성을 가지는 개질아스팔트 방수시트재의 연화점(softening point), 침입도(penetration), 저온굴곡저항성능(low temperature flexibility), 점도(viscosity) 및 부착성능(adhesion) 등의 물성을 관찰하고, 반응표면분석법(response surface methodology, RSM)을 활용하여 아스팔트 질량 대비 SBS와 SIS의 적정조성을 도출하고 자가치유성을 가지는 개질아스팔트 방수시트재의 물성을 최적화하였다. 고온에서 측정이 수행되는 연화점과 점도는 SBS 또는 SIS의 함량이 증가함에 따라서 유의하게 값이 증가하였다. 그러나 함량 대비 연화점과 점도 증가분은 SBS 경우가 SIS보다 커짐이 관찰되었다. 이러한 원인은 SBS와 SIS의 열적거동의 차이 때문인데, SBS는 고온에서 점도 상승을 동반하는 겔화(gelation)가 되어 가교도가 커지나 SIS는 점도감소를 초래하는 폴리이소프렌 블록의 사슬분리(chain scission) 때문에 사슬꼬임(chain entanglement)이 상대적으로 적어지기 때문이다. 반면에 SIS-SBS 개질아스팔트는 상온에서 측정되는 침입도, 부착성능 및 저온굴곡성능에 대하여, 아스팔트 63 g을 기본으로 SIS 4~5 g과 SBS 8.5 g의 조성에서 최소 탄성거동을 나타내어 최대 침입도 및 최대 부착성능과 최저 저온굴곡성능 값을 보였다.

인공광을 이용한 접목표 활착촉진 시스템의 시작품 설계 - 활착촉진 시스템 내의 기온과 상대습도 분포에 미치는 기류속도의 효과 (Design of a Prototype System for Graft-Taking Enhancement of Grafted Seedlings Using Artificial Lighting - Effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system)

  • 김용현
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.213-220
    • /
    • 2000
  • Grafting of fruit-bearing vegetables has been widely used to increase the resistance to soil-borne diseases, to increase the tolerance to low temperature or to soil salinity, to increase the plant vigor, and to extend the duration of economic harvest time. After grafting, it is important to control the environment around grafted seedlings for the robust joining of a scion and rootstock. Usually the shading materials and plastic films are used to keep the high relative humidity and low light intensity in greenhouse or tunnel. It is quite difficult to optimally control the environment for healing and acclimation of grafted seedlings under natural light. So the farmers or growers rely on their experience for the production of grafted seedling with high quality. If artificial light is used as a lighting source for graft-taking of grafted seedlings, the light intensity and photoperiod can be easily controlled. The purpose of this study was to develop a prototype system for the graft-taking enhancement of grafted seedlings using artificial lighting and to investigate the effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system. A prototype graft-taking system was consisted by polyurethane panels, air-conditioning unit, system controller and lighting unit. Three band fluorescent lamps (FL20SEX-D/18, Kumho Electric, Inc.) were used as a lighting source. Anemometer (Climomaster 6521, KANOMAX), T-type thermocouples and humidity sensors (CHS-UPS, TDK) were used to measure the air current speed, air temperature and relative humidity in a graft-taking system. In this system, air flow acted as a driving force for the diffusion of heat and water vapor. Air current speed, air temperature and relative humidity controlled by a programmable logic controller (UP750, Yokogawa Electric Co) and an inverter (MOSCON-G3, SAMSUNG) had an even distribution. Distribution of air temperature and relative humidity in a graft-taking enhancement system was fairly affected by air current speed. Air current speed higher than 0.1m/s was required to obtain the even distribution of environmental factors in this system. At low air current speed of 0.1m/s, the evapotranspiration rate of grafted seedlings would be suppressed and thus graft-taking would be enhanced. This system could be used to investigate the effects of air temperature, relative humidity, air current speed and light intensity on the evaportranspiration rate of grafted seedlings.

  • PDF