• Title/Summary/Keyword: head field

Search Result 1,063, Processing Time 0.027 seconds

A Computational Method to Consider the Saturation of Magnetic Field In a High Density Recording Head

  • Park, Gwan-Soo
    • Journal of Magnetics
    • /
    • v.8 no.4
    • /
    • pp.164-168
    • /
    • 2003
  • In high density recording system, the recording head field on a medium should be focused in small bit area and should have a sufficient value to overcome the medium coercivity, which resulted in head saturation. In this paper, an efficient method to access the head field and field gradient considering head saturation is presented. The magnetic vector potential on the head surface is pre-calculated considering head saturation in several cases and accumulated into database. The head field on the recording media is easily produced solving Laplace equation using accessed magnetic vector potential boundaries. The computed head field is compared with a quantified magnetic force microscopy measurement.

Numerical Analysis of Electric Field Distribution Induced Inside a Realistic Brain Model Considering Conductivity Heterogeneity (전기전도도의 비균질성을 고려한 정밀 두뇌 모형 내부에서 유기되는 유도 전기장 분포해석)

  • Kim, Dong-Hun;Lee, Il-Ho;Won, Chul-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.314-319
    • /
    • 2008
  • In this paper, the electric field distribution induced inside the brain during Transcranial Magnetic Stimulation(TMS) has been thoroughly investigated in terms of tissue heterogeneity and anisotropy as well as different head models. To achieve this, first, an elaborate head model consisting of seven major parts of the head has been built based on the Magnetic Resonance(MR) image data. Then the Finite Element Method(FEM) has been used to evaluate the electric field distribution under different head models or three different conductivity conditions when the head model has been exposed to a time varying magnetic field achieved by utilizing the Figure-Of-Eight(FOE) stimulation coil. The results show that the magnitude as well as the distribution of the induced field is significantly affected by the degree of geometrical asymmetry of head models and conductivity conditions with respect to the center of the FOE coil.

Investigation of Interface between Slider and Plastic Disk for Optical Head (Optical head를 고려 한 slider와 plastic disk의 interface에 대한 연구)

  • 박진무;정구현;김대은
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.193-198
    • /
    • 2000
  • Near-field recording NFR), advanced optical storage technology, relies on maintaining a small gap between the optical head and the media. This can be accomplished by utilizing the flying optical head concept as in the magnetic recording. In this research, slider/suspension system and plastic disk are tested for their head/disk interface performance. CSS tests are conducted to monitor the frictional and flying characteristics of sliders.

  • PDF

Visual Fields Reflecting Effects of Target Size, Color and Meridian in Visual Tasks (시각작업의 설계와 평가를 위한 표적의 크기, 색과 위치에 따른 시각영역)

  • Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.27 no.2
    • /
    • pp.190-196
    • /
    • 2001
  • This study aims to develop three types of the visual fields: stationary field, eye field, and head field, which are classified depending upon the eye and head movements. A visual experiment taking target size, target color, and meridian into account was conducted, in which the L32 orthogonal array was employed. The results showed that target size and meridian were significant at ${\alpha}$=0.01 in all three visual fields. Contrary to expectation, target color was significant at ${\alpha}$=0.10 only in the head field. Furthermore, the differences in size of the head field depending upon four target colors were negligibly small. Three linear regression models were provided to generate visual fields which are appropriate for given visual task's characteristics. In addition, a simple method using adjusting factor was also proposed so that anyone without knowledge for human factors/ergonomics can easily generate and use them when designing or evaluating visual tasks. It is expected that the visual fields presented in this study can be easily used even by non-ergonomic experts in real situations due to their simplicity.

  • PDF

HRTF-field reproduction for robust virtual source imaging (머리 전달 함수장 재현을 통한 광대역 입체 음향 구현)

  • Choi, Joung-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.997-1004
    • /
    • 2007
  • A hybrid technique that combines the advantages of binaural reproduction and sound field reproduction technique is proposed. The concept of HRTF-field, which is defined as the set of HRTFs corresponding to the various head dislocations, enables us to realize virtual source imaging over a wide area. Conventional $2{\times}2$ definition is redefined as a MIMO system composed of multiple control sources and multiple head locations, and HRTF variations corresponding to various head movement are quantified. Through the direct control of HRTF-field, reproduction error induced by head dislocation can be minimized in least-square-error sense, and consequential disturbances on the virtual source image can be reduced within a selected area. Simple lateralization examples are investigated, and the reproduction error of the proposed technique is compared to that of Higher-order Ambisonics.

  • PDF

HRTF-field Reproduction for Robust Virtual Source Imaging (머리 전달 함수장 재현을 통한 광대역 입체 음향 구현)

  • Choi, Joung-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.2
    • /
    • pp.199-207
    • /
    • 2008
  • A hybrid technique that combines the advantages of binaural reproduction and sound field reproduction technique is proposed. The concept of HRTF-field, which is defined as the set of HRTFs corresponding to the various head dislocations, enables us to realize virtual source imaging over a wide area. Conventional binaural($2{\times}2$) reproduction system is redefined as a MIMO system composed of multiple control sources and multiple head locations, and HRTF variations corresponding to various head movement are quantified. Through the direct control of HRTF-field, reproduction error induced by head dislocation can be minimized in least-square-error sense, and consequential disturbances on the virtual source image can be reduced within a selected area. Simple lateralization examples are investigated, and the reproduction error of the proposed technique is compared to that of higher-order Ambisonics.

Magnetic Orientations of Bull Sperm Separated into Head and Flagellum Treated by DTT or Heparin

  • Suga, D.;Shinjo, A.;Kurnianto, E.;Nakada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.2
    • /
    • pp.167-175
    • /
    • 2000
  • This paper describes the magnetic orientation of bull sperm separated into the head and the flagellum treated by DTT or heparin in a 5,400G static field. Semen samples collected from four bulls (Japanese Black) were mixed to the same sperm density. One percentage triton X-100 was used to extract the plasma membrane. The intact and demembranated sperm suspensions were treated with 20, 200, 2,000 mM DTT, 100, 1,000 or 10,000 units heparin solutions at $4^{\circ}C$ for 6 days. The decondensation of the sperm nuclei treated by DTT or heparin was examined by measuring the head area at 1, 3 and 6 days. After measuring the area, each sample was exposed to a 5,400G static magnetic field generated by Nd-Fe-B permanent magnets for 24 hours at room temperature. Results showed that the sperms were separated into the head and the flagellum through the DTT treatment. Almost of the separated heads showed that their long axis oriented perpendicularly to the magnetic lines of force, and most of the long axis perpendicularly oriented heads showed that their flat plane oriented perpendicularly in a 5,400G magnetic field. Also, the demembranation of the head tended to increase those perpendicular orientations, while those perpendicular orientations of the head declined with the decondensation of the sperm nuclei. These findings suggest that strong magnetic anisotropy for the perpendicular orientation of the long axis and the flat plane of the head occurs in the sperm nuclei in a 5,400G magnetic field. The separated flagellum showed lower parallel orientation, and the separated and demembranated flagellum showed parallel orientation to the magnetic lines of force in this magnetic field. These findings suggest that weak magnetic anisotropy of the parallel orientation of the flagellum occurs in the inside components in a 5,400G field.

The Analysis of Drop-On-Demand Characteristic of Electrostatic Field Induced Inkjet Head System with Carbon Nano Tube (CNT) Ink (정전기장 유도된 잉크젯 프린터 헤드를 이용한 탄소나노튜브 잉크의 Drop-On-Demand 특성 연구)

  • Choi, J.Y.;Kim, Y.J.;Son, S.U.;Kim, Y.M.;Byun, D.Y.;Ko, H.S.;Lee, S.H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1445-1449
    • /
    • 2007
  • This paper presents the DOD (Drop-On-Demand) characteristic using the electrostatic field induced inkjet printing system. In order to achieve the DOD characteristic of electrostatic field induced inkjet printing, applied the bias voltage of 1.4 kV and the pulse voltage of $2.0\;kV\;{\sim}\;2.7\;kV$ using high voltage pulse generator. Electrostatic field induced droplet ejection is directly observed using a high-speed camera and for investigated DOD characteristic, CNT ink used. The electrostatic field induced inkjet head system has DOD characteristic using pulse generator which can be applied pulse voltage. The bias voltage has a good condition which form meniscus and has micro dripping mode for small size micro droplet. Also, the droplet size decreases with increasing the applied pulse voltage. This paper shows DOD characteristic at electrostatic field induced inkjet head system, Therefore. electrostatic DOD inkjet head system will be applied industrial area comparing conventional electrostatic inkjet head system.

A Study on Assembly and Evaluation of SIL optical Head for surface Recording of SIL based NFR (고체침지렌즈 기반 근접장 표면 기록을 위한 고체침지렌즈 광학 헤드의 조립 및 평가에 대한 연구)

  • Min, Cheol-Ki;Kim, Tae-Seob;Yoon, Yong-Joong;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.4 no.1
    • /
    • pp.19-22
    • /
    • 2008
  • For the assembly and evaluation of solid immersion lens (SIL) optical head which is the key component of SIL based near field recording (NFR) technology, we modify the Twyman-Green interferometer. Super-hemisphere SIL optical head for the surface recording is assembled and evaluated by the modified Twyman-Green interferometer. In order to verify the optical performance of the assembled SIL optical head, we compare the measured results of the SIL optical head with the simulation ones. Finally, we show the feasibility of applying the assembled SIL optical head to near field recording system by the experiment of the dynamic gap control based on test bed.

  • PDF

Effect of soft underlayer on read/write in double layered perpendicular recording media (이중층 수직기록 매체에서 read/write 특성에 미치는 soft underlayer의 효과)

  • 이성철;탁영욱;이택동;이경진
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.180-181
    • /
    • 2002
  • 수직기록매체에서 기록 밀도가 증가하기 위해서는 bit의 크기를 줄여야 하고, 이를 위해서는 writing head의 width와 thickness를 줄여야 한다. 그러나 head의 크기가 줄어들면 기록층의 자화를 반전시키기에 충분한 write field를 얻지 못한다. 이를 극복하기 위해 head의 tip부분을 trimming을 하여 작은 pole tip 크기를 가지면서도 큰 write field를 얻고, 여분의 magnetic field를 얻기 위해 soft underlayer를 도입하는 이중층 수직기록 매체가 제안되고 있다. (중략)

  • PDF