• Title/Summary/Keyword: head direction

Search Result 530, Processing Time 0.033 seconds

A Relevant Distortion Criterion for Interpolation of the Head-Related Transfer Functions (머리 전달 함수의 보간에 적합한 왜곡 척도)

  • Lee, Ki-Seung;Lee, Seok-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.85-95
    • /
    • 2009
  • In the binaural synthesis environments, wide varieties of the head-related transfer functions (HRTFs) that have measured with a various direction would be desirable to obtain the accurate and various spatial sound images. To reduce the size' of HRTFs, interpolation has been often employed, where the HRTF for any direction is obtained by a limited number of the representative HRTFs. In this paper, we study on the distortion measures for interpolation, which has an important role in interpolation. With lhe various objective distortion metrics, the differences between the interpolated and the measured HRTFs were computed. These were then compared and analyzed with the results from the listening tests. From the results, the objective distortion measures were selected, that reflected the perceptual differences in spatial sound image. This measure was employed in a practical interpolation technique. We applied the proposed method to four kinds of an HRTF set, measured from three human heads and one mannequin. As a result, the Mel-frequency cepstral distortion was shown to be a good predictor for the differences in spatial sound location, when three HRTF measured from human, and the time-domain signal to distortion ratio revealed good prediction results for the entire four HRTF sets.

RADIOGRAPHIC STUDY ON THE INTERRELATION BETWEEN BONE DEF ORMANS AND CONDYLAR HEAD POSITION IN THE TMJ ARTHROSIS (악관절증에서의 골형태이상과 과두위변화와의 상호관계에 관한 방사선학적 연구)

  • You Dong Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.79-87
    • /
    • 1981
  • The author analysed the interrelation between the morphologic changes of bone Structures and the position of condylar head from the routine radiographs of 134 cases of the temporomandibular joint arthrosis. The frequencies of coincidence between the site of bone defrmity and condylar head positional change were examined. Also, the positional changes of condylar head and the direction of condylar movement in relation to the kind of bone deformities were observed. The results obtained were as follows; 1. In 52.65 per cent of total cases, the site, of positional change of condylar head was coincided with the site of bone deformans. The frequencies of the coincidence between these in the five items among seven items examined were above 53 per cent. From the results, it seems that the positional changes of condylar head were related with the morphological change of bone structure. 2. Eburnation and erosion. revealed frequently positional changes in the opening and closing position of the mouth, although in the early stages of the TMJ arthrosis. 3. In the bone deformans, during opene position of the mough 44.81 per cent of total cases revealed backword movement and 37.74 per cent showed forward movement. In closed position of the mouth, downward movement was revealed in 35.23 per cent of total cases and upward movement 28.41 per ,cent of total cases. 4. In the cases showing eburnation, the frequencies of coincidence between the site of positional change and bone deformans were 58.57 per cent of the total cases. that means it was high in the early stages of the TMJ arthrosis.

  • PDF

A Study to Acquire Sharp Images in the Haas(Skull PA Axial Projection) (Haas 촬영법에서 선예한 영상 획득을 위한 연구)

  • Ahn, Jun-Ho;Han, Jae-Bok;Song, Jong-Nam;Kim, In-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.319-325
    • /
    • 2022
  • The Study In order to obtain a sharpness Image from Skull PA axial projection (Haas) in a head axial X-ray Examination, this study changed the posture angle using Skull Phantom and evaluated the image subjectively to 5 radiologists who worked in the Department of Imaging at University Hospital. In the prone position, the head was lowered 4 cm from the back of the head, entered 25° toward the head, and the image evaluation score was high with 20 points, such as the back bone, dorsum sellae projected in the large hole, and posterior clinoid process. In addition, the score significance was verified, and the Cronbach Alpha value was evaluated to have good reliability of 0.789. As a result of calculating the signal-to-noise ratio (SNR) by setting the region of interest (ROI) of the image, it was the highest at 5.957 for 25° incident at the back of the head and 6.430 for 30° incident at the back of the head. As a result of the study, in order to obtain a sharp image of the back of the head bone, dorsum sellae, and posterior clinoid process when shooting in the axial direction after the head, it is filmed by tilting 25° toward the head from 4 cm below the back of the head. In order to obtain a sharp image of rock pyramid symmetry, petrous ridge, sagittal suture, and lambdoid suture, it is thought that it will be helpful for clinical use if you shoot it 8cm down from the back of the head and tilt it 30° toward the head.

A Study of the High Touch in Contemporary Fashion (현대 패션에 나타난 하이터치(High Touch)에 관한 연구)

  • Kim, Bo-Young;Geum, Key-Sook
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.4
    • /
    • pp.72-85
    • /
    • 2008
  • With the new millennium setting in, our society is plowing its way through more drastically changing currents than ever. Nowadays, many people believe that high tech such as the Internet, digital civilization, the IT revolution, bio-industry, and the genome project, that has brought humans material prosperity, is the right change in direction. However, the more we adopt high tech into our lives, the more we desire high touch in order to achieve a balance. In other words, we need something to act as a ballast to stabilize our minds. As such, the more high tech develops, the more individuals miss and search for tools that appeal to their emotions. Because of this, although high touch is an opposite concept to high tech, it coexists with high tech, and it is defined as "human contact of high sensitivity that stimulates the emotion of humans". High Touch, a term which originated from "High Tech, High Touch", a book written by American futurist John Naisbitt, refers to human contact that makes human life richer, forminga deep impression on individuals and providing comfort. As such, high touch, which is gaining significant attention in modern society, is a phenomenon occurring throughout politics, society, culture, art, and religion, together with high tech. Through high touch, modern people must realize how to understand and accept a modern society that is dominated by the age of technology and in which direction they should head. Under this background, this study has the following objectives: to interpret the concept of high touch in the age of high tech in association with formative art and fashion, and through various media examine the desire for expression that may stimulate emotion in modern people, which is required by the high tech-prevalent modern society. It further analyzes how high touch is reflected in modern fashion and presents the direction future fashion should head in.

Human Spatial Cognition Using Visual and Auditory Stimulation

  • Yu, Mi;Piao, Yong-Jun;Kim, Yong-Yook;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.2
    • /
    • pp.41-45
    • /
    • 2006
  • This paper deals with human spatial cognition using visual and auditory stimulation. More specially, this investigation is to observe the relationship between the head and the eye motor system for the localization of visual target direction in space and to try to describe what is the role of right-side versus left-side pinna. In the experiment of visual stimulation, nineteen red LEDs (Luminescent Diodes, Brightness: $210\;cd/^2$) arrayed in the horizontal plane of the surrounding panel are used. Here the LEDs are located 10 degrees apart from each other. Physiological parameters such as EOG (Electro-Oculography), head movement, and their synergic control are measured by BIOPAC system and 3SPACE FASTRAK. In the experiment of auditory stimulation, one side of the pinna function was distorted intentionally by inserting a short tube in the ear canal. The localization error caused by right and left side pinna distortion was investigated as well. Since a laser pointer showed much less error (0.5%) in localizing target position than FASTRAK (30%) that has been generally used, a laser pointer was used for the pointing task. It was found that harmonic components were not essential for auditory target localization. However, non-harmonic nearby frequency components was found to be more important in localizing the target direction of sound. We have found that the right pinna carries out one of the most important functions in localizing target direction and pure tone with only one frequency component is confusing to be localized. It was also found that the latency time is shorter in self moved tracking (SMT) than eye alone tracking (EAT) and eye hand tracking (EHT). These results can be used in further study on the characterization of human spatial cognition.

Experimental Study on Ground Subsidence and Underground Cavity Expansion under Various Conditions (다양한 조건에 따른 지반함몰과 지중공동 확장에 대한 실험적 연구)

  • Jeong, SeongYun;Karoui, Tarek;Jeong, YeongHoon;Kim, DongSoo
    • The Journal of Engineering Geology
    • /
    • v.27 no.2
    • /
    • pp.143-152
    • /
    • 2017
  • Recently frequent occurrence of ground subsidence cases has become social issue, and people's concern on this problem has been growing accordingly. Meanwhile, understanding on the mechanism of ground subsidence formation is not enough. Therefore, this study aims for evaluating formation mechanism of ground subsidence under various groundwater conditions through model test when groundwater and soil are leaked together. Major factors found through model tests are direction of groundwater flow, head difference around the leakage point, and strehgth of the ground to support the underground cavity. Firstly, direction of groundwater flow has an influence on the direction of cavity expansion and ground collapse. Secondly, it is observed that the speed of ground subsidence formation increases as the head difference increases. Lastly, the expansion of the cavity can eventually lead to a sudden collapse.

The Kinematical Analysis of the Over Head Kick in Soccer (축구 오버헤드 킥 동작의 운동학적 분석)

  • Kim, Eui-Hwan;Lee, Yo-Yeoul;Kim, Sung-Sup;Kwon, Mook-Seok;Kim, Sung-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.155-171
    • /
    • 2003
  • The purpose of this study was to analyze the kinematic variables of over head kick(OHK) in soccer with three dimensional analysis technique and show the kinematic characteristics of it. The 7 subjects were university football player who have been playing football more than 7 years. The OHK was filmed on 16mm video camera(30frame/sec.) kinematic variables were temporal, postures, and COG(center of gravity). The mean values and the standard deviation for each variables were obtained and used as basic factors for examining characteristics of OHK. The results of this analysis were as follows : Temporal variables : The total time elapsed(TE) of OHK was $0.95{\sim}1.14sec$, the 1st phase was 0.35sec., 2nd phase was 0.46sec., and 3rd phase was 0.22sec.. Posture variables : When subjects performed OHK at the impact event, the ankle and knee angle of kicking foot were more extend than supporting foot. but the hip angle of supporting foot were more extend than kirking foot. Moving distance of the center of mass of the both foot. When subject performed OHK at the impact event, the range of distance on mediolateral direction aspect into right left shoulder line, anteroposterior direction aspect was $20.9{\pm}10.5cm$, vertical direction aspect was $92.3{\pm}19.9cm$. Angular velocity : the faster angular velocity of knee ankle on the kicking foot pew form jump position to landing position, the faster velocity of ball became. C. O. G. variables. When subject performed OHK at the impact event, upper part of the body was getting lower, lower part of the body was getting higher.

Bone Density Spatial Distribution of Radiation Dose Measurement (양방사선 골밀도 측정 장치의 공간산란선량분포측정)

  • Kim, Seon-Chil;Won, Do-Yeon;Park, Chang-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2011
  • In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation $0^{\circ}$ head end was higher in the direction of the highest dose rate, $0^{\circ}$ $180^{\circ}$ direction from the direction towards the higher dose rate reduced to some extent in the direction of all the $120^{\circ}$ were able to identify.

  • PDF

Reconstruction of the Shoulder using Rotational Latissimus Dorsi Flap in the Malignant Fibrous Histiocytoma (악성 섬유성 조직구종에서 광배근피판을 이용한 견관절 재건술)

  • Han, Chung-Soo;Chung, Duke-Whan;Lee, Young-Ho;Im, Yang-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.111-117
    • /
    • 2001
  • Introduction : The Functional muscle transfer is used to reconstruct the injuried muscle and paralysis of the shoulder. Especially transfer of the trapezius has been the treatment of choice but it has disadvantages of inadequate function and deformed contour, and instability of humeral head in case of acromion resection. We report an operation for shoulder reconstruction after wide resection of malignant fibrous histiocytoma, using rotational latissimus dorsi flap and review the operation method and clinical outcome. Materials and Methods : A patient, 53 year old, with malignant fibrous histiocytoma in the acromioclavicular joint area had been underwent wide excision, including the deltoid, clavicular head of pectoralis major, part of trapezius, lateral 1/3 of clavicle and acromion including scapular spine. The rotational latissimus dorsi flap with its neurovascular pedicle was dissected and then placed over the resected area and transfer of muscle attached at coracoid process was done to achieve stability of the humeral head. The range of motion of the shoulder and test of muscle power were evaluated for functional outcome. Total follow-up period is 2 years 11 months. Results : At last follow-up, the range of motion of the shoulder is abduction $90^{\circ}$, flexion $90^{\circ}$, internal rotation $40^{\circ}$, external rotation $50^{\circ}$ and the muscle power is 4 grade in all direction and then we obtained good functional results. There are no complications such as instability or subluxation of the humeral head and deformed contour and he is a disease-free survival state. Conclusions : The transfered latissimus dorsi flap provides adequate lever arm and stabilization and covering of the humeral head by sufficient muscle volume and width. This procedure can be useful not only for the paralysed deltoid reconstruction but also for use in reconstructive surgery after wide resection of the shoulder for malignant tumor.

  • PDF

Study on Optimal Working Conditions for Picking Head of Self-Propelled Pepper Harvester by Factorial Test

  • Kang, Kyung-Sik;Park, Hoon-Sang;Park, Seung-Je;Kang, Young-Sun;Kim, Dae-Cheol
    • Journal of Biosystems Engineering
    • /
    • v.41 no.1
    • /
    • pp.12-20
    • /
    • 2016
  • Purpose: Pepper prices have risen continuously because of a decrease in cultivation area; therefore, mechanical harvesting systems for peppers should be developed to reduce cost, time, and labor during harvest. In this study, a screw type picking head for a self-propelled pepper harvester was developed, and the optimal working conditions were evaluated considering helix types, winding directions of helix, and rotational speeds of the helix. Methods: The screw type was selected for the picking head after analyzing previous studies, and the device consisted of helices and a feed chain mechanism for conveying pepper branches. A double helix and a triple helix were manufactured, and rotational speeds of 200, 300, and 400 rpm were tested. The device was controlled by a variable speed (VS) motor and an inverter. Both the forward and reverse directions were tested for the winding and rotating directions of the helix. An experiment crop (cultivar: Longgreenmat) was cultivated in a plastic greenhouse. The test results were analyzed using the SAS program with ANOVA to examine the relationship between each factor and the performance of the picking head. Results: The results of the double and triple helix tests in the reverse direction showed gross harvest efficiency levels of 60-95%, mechanical damage rates of 8-20%, and net marketable portion rates of 50-80%. The dividing ratio was highest at a rotational speed of 400 rpm. Gross harvest efficiency was influenced by the types of helix and rotational speed. Net marketable portion was influenced by rotational speed but not influenced by the type of helix. Mechanical damage was not influenced by the type of helix or rotational speed. Conclusions: Best gross harvest efficiency was obtained at a rotational speed of 400 rpm; however, operating the device at that speed resulted in vibration, which should be reduced.