• Title/Summary/Keyword: head control

Search Result 1,771, Processing Time 0.04 seconds

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

A Numerical Study on the Effect of Volute Geometry on the Performance of Centrifugal Pump (볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구)

  • Kim, Deok-Su;Jeon, Sang-Gyu;Yoon, Joon-Yong;Choi, Young-Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.2 s.35
    • /
    • pp.44-49
    • /
    • 2006
  • In this study, the effects of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate, the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

Study of Human Perceptual Characteristics of Body Inclination Using a Tilt Bed

  • Inooka, Hikaru;Kim, HiSik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.94.2-94
    • /
    • 2001
  • This paper investigates human discomfort response to the foot-to-head acceleration. During ambulance transport, a patient suffers from the foot-to-head acceleration, which might deteriorate his illness. To investigate the relationship between the ride discomfort and the foot-to-head acceleration, experiments were performed using a van type automobile similar to an ambulance. The experimental results show that head-ward acceleration is more uncomfortable than the foot-ward acceleration. For further investigation of the difference of ride discomfort caused by the direction of acceleration, two experiments were peformed using a tilt bed. In these experiments, foot-to-head acceleration is applied to the subjects by tilting the bed. Using a tilt bed, we investigated two things; relationship between discomfort and inclination of the bed ...

  • PDF

A Numerical Study on the effect of Volute Geometry on the Performance of Centrifugal Pump (볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구)

  • Kim, Deok-Su;Choi, Young-Seok;Jeon, Sang-Gyu;Yoon, Joon-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.497-502
    • /
    • 2005
  • In this study. the effect of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate. the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry. The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

  • PDF

Effect of Volute Area Distributions on the Performance Characteristic Curve of a Centrifugal Pump (볼류트 단면적 변화가 원심펌프의 성능곡선에 미치는 영향)

  • Kim, Deok-Su;Lee, Kyoung-Young;Yoon, Joon-Yong;Choi, Young-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.558-563
    • /
    • 2005
  • In this paper, the effect of volute area distribution on the performance characteristic curve of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate, the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequency required. In order to control the shutoff head of a pump, several volute area distributions were proposed as a main parameter with the same impeller geometry. The calculation results show that the characteristic curve of a centrifugal pump can be controlled by modifying the area distribution with the same volute outlet area.

  • PDF

Effect of Head of the Line Blocking on Session Initiation Protocol Session Establishment Delays

  • Camarillo, Gonzalo;Schulzrinne, Henning;Loreto, Salvatore;Hautakorpi, Jani
    • Journal of Communications and Networks
    • /
    • v.11 no.1
    • /
    • pp.72-83
    • /
    • 2009
  • We have studied the effect of head of the line blocking (HOLB) on session initiation protocol (SIP) session establishment delays. Our results are based on experiments performed in a test bed and on the public Internet. We used the stream control transmission protocol (SCTP) as a transport for SIP because SCTP can be configured to suffer or to avoid HOLB. Our experiments show that the effect of HOLB on session establishment delays generally starts to be significant starting at fairly low packet loss rates. However, there are scenarios where network conditions are good enough to make the effect of HOLB insignificant.

Development of Bridge Circuit for Measuring Pressure Wave in Inkjet Head (잉크젯 압력파 측정을 위한 브리지 회로 개발)

  • Kwon, Kye-Si;Myung, Jae-Hwan;Joo, Young-Cheol;Lee, Sang-Wook;Kim, Kug-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.4
    • /
    • pp.342-347
    • /
    • 2008
  • Bridge circuit was developed such that the pressure wave in the inkjet can be measured. In order to test the circuit, the microfab single ejector was used. For the experiment, the head was filled with nano silver ink (20wt%). In order to generate waveform voltage for jetting signal, the Agilent 33120 was used in order to generate arbitrary waveform. For the driver, PZD 350 from TREK was used in order to amplify the waveform. Experimental results show that the designed circuit can effectively detect the pressure wave in the inkjet head.

Head louse infestation in vagrants and children admitted to public welfare facilities, Republic of Korea (사회복지 시설에 수용된 부랑인과 아동에 대한 머릿니 조사)

  • Sun HUH;Ki-Soo PAI
    • Parasites, Hosts and Diseases
    • /
    • v.33 no.1
    • /
    • pp.69-71
    • /
    • 1995
  • From December 1992 to February 1993, all vagrants and children admitted to public welfare facilities supported by the Government of Republic of Korea were examined for the presence of nit, nymph or adult of head louse. Of 36,055 persons examined, the number of positive was 7,393 (20.5%). Intensive control measures are needed to control this ectoparasitic infestation.

  • PDF

Design and Fabrication of a Conductively Cooled Cryostat by Cryocooler (냉동기 부착형 전도냉각식 Cryostat의 설계 및 제작)

  • Bae, Joon-Han;Sim, Ki-Deck
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1921-1924
    • /
    • 2007
  • In order to measure the superconducting transition temperature, the critical current and the alternating current(AC) loss on short samples of high temperature superconductor, a cryocooler cooled cryostat has been designed and built. Two closed-cycle coolers provide cooling with an ultimate sample temperature below 16K. Temperature regulation is provided by 50W of electrical heater that opposes the cooling power from the cold heads. Temperature control feedback is by means of a cernox temperature sensor co-located with the heaters on the second stage of the cold head. Additional temperature sensors are located on the sample mount(B1), on the CVI cold head(B2) and on the Dakin cold head(B3). AC losses on the sample high temperature superconductor were measured at 30K so that the developed device performance was evaluated. In this paper, the design, fabrication and test results on the cryocooler cooled cryostat are presented.