• 제목/요약/키워드: harmonic performance.

검색결과 838건 처리시간 0.031초

A Fast Harmonic Estimation Method for Low Bit Rate Harmonic Speech Coders

  • Park, Yong-Soo;Youn, Dae-Hee;Kang, Tae-lk
    • The Journal of the Acoustical Society of Korea
    • /
    • 제20권4E호
    • /
    • pp.24-30
    • /
    • 2001
  • This paper describes a fast harmonic estimation, referred to as Delta Adjustment (DA), using a low resolution pitch. The presented DA method is based on modification of the Generalized Dual Excitation (GDE) technique[1] which was proposed to improve speech enhancement performance. We introduce the GDE technique and modify it to be suitable for low bit rate harmonic coding that uses only an integer pitch estimate. Unlike the GDE, the DA matches a frequency-warped version of the original spectrum that conforms to a fixed pitch at all harmonic bands. In addition, complexity and performance of the presented method are described in comparison with those of the conventional Fractional Pitch (FP) based harmonic estimation. Experimental results showed that the DA algorithm significantly reduces the complexity of the FP method while maintaining the performance.

  • PDF

비선형 전송선로를 이용한 고조파 발생기 성능 비교 (The Performance Comparison of The Harmonic Generators using Nonlinear Transmission Lines)

  • 박순우;김홍준;유형석
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1212-1216
    • /
    • 2015
  • In this paper, we compared the performance of the Right Handed Nonlinear Transmission Line (RH-NLTL) and Left Handed Nonlinear Transmission Line (LH-NLTL) as a harmonic generator. For a performance comparison, we fabricated both a RH-NLTL and a LH-NLTL harmonic generator whose operational bandwidth is from 0.5 GHz to 1.5 GHz. Under the each condition for the RH-NLTL and the LH-NLTL to maximize second harmonic, the output power of the second harmonic was 9.33 dB lower than the input power for the RH-NLTL and 12.67 dB lower than the input power for the LH-NLTL. Under the each condition for the RH-NLTL and the LH-NLTL to maximize third harmonic, the output power of the third harmonic was 13.33 dB lower than the input power for the RH-NLTL and 14.83dB lower than the input power for the LH-NLTL. Also, we have observed that, generatlly, a RH-NLTL is useful in generating various multiple harmonics and a LH-NLTL is useful in generating a specific order of harmonic by adjusting a proper DC vias, input frequency and input power. These tendencies could be a good guideline to use NLTLs as a frequency multiplier.

배전계통의 고 임피던스 고장 검출 고조파 변수 성능 평가 (Performance Evaluation of the Harmonic Parameters for High Impedance Fault Detection in Distribution System)

  • 오용택;김창종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.883-885
    • /
    • 1997
  • High impedance fault(HIF) is random in its behavior even in a similar environment. The detection of Ire HIF has focused on the development of algorithms based on harmonic, parameters of the arc currents. However, a fact that proper selection of the harmonic parameters, rather than algorithm selection, is more important is shown in this paper by applying three different performance evaluation methods on two HIF detection algorithms using eight harmonic parameters.

  • PDF

단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구 (A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters)

  • 조영식;차한주
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

단상 전원 고조파 제거 시스템을 위한 기준전류 생성회로에 대한 연구 (A Study of the Current Reference Signal Generation Circuit for Single-Phase Harmonic Elimination Systems)

  • 정동열;박종연;김상훈;최원호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권7호
    • /
    • pp.335-342
    • /
    • 2005
  • This paper presents a circuit to generate the current reference signal for single-phase harmonic elemination systems. Some of conventional methods for the current reference signal generation based on neural network algorithms. It requires complex circuitry to implement. the simplest method is to use analog filters. but it is difficult to obtain good current reference signals. So, we propose the harmonic detection circuit using GIC(Generalized Impedance Converter) for the purpose of low cost ,simple circuitry and high performance, Simulation and experimental results verify that the proposed circuit has better harmonic detection performance than conventional circuit.

디지털 록인 앰프를 이용한 비정현 계통 전압 하에서 강인한 단상계통 연계 인 버터용 고조파 보상법 (A Robust Harmonic Compensation Technique using Digital Lock-in Amplifier under the Non-Sinusoidal Grid Voltage Conditions for the Single Phase Grid Connected Inverters)

  • 칸 아마드 레이안;아쉬라프 모하마드 노만;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.95-97
    • /
    • 2018
  • The power quality of Single Phase Grid-Connected Inverters (GCIs) has received much attention with the increasing number of Distributed Generation (DG) systems. However, the performance of single phase GCIs get degraded due to several factors such as the grid voltage harmonics, the dead time effect, and the turn ON/OFF of the switches, which causes the harmonics at the output of GCIs. Therefore, it is not easy to satisfy the harmonic standards such as IEEE 519 and P1547 without the help of harmonic compensator. To meet the harmonic standards a certain kind of harmonic controller needs to be added to the current control loop to effectively mitigate the low order harmonics. In this paper, the harmonic compensation is performed using a novel robust harmonic compensation method based on Digital Lock-in Amplifier (DLA). In the proposed technique, DLAs are used to extract the amplitude and phase information of the harmonics from the output current and compensate it by using a simple PI controller in the feedforward manner. In order to show the superior performance of the proposed harmonic compensation technique, it is compared with those of conventional harmonic compensation methods in terms of the effectiveness of harmonic elimination, complexity, and implementation. The validity of the proposed harmonic compensation techniques for the single phase GCIs is verified through the experimental results with a 5kW single phase GCI. Index Terms -Single Phase Grid Connected Inverter (SPGCI), Harmonic Compensation Method, Total Harmonic Distortion (THD) and Harmonic Standard.

  • PDF

A New Assessment for the Total Harmonic Contributions at the Point of Common Coupling

  • Han, Jong-Hoon;Lee, Kyebyung;Song, Chong Suk;Jang, Gilsoo;Byeon, Gilsung;Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.6-14
    • /
    • 2014
  • A new method to determine the total harmonic contributions of several customers and the utility at the point of common coupling is presented. The proposed method can quantify the individual harmonic impact of each suspicious harmonic source at the point of common coupling. The individual harmonic impact index is then used to assess the total harmonic contribution of each harmonic source. This index can be calculated by the results processed from instantaneous harmonic voltage and current phasor values. The results demonstrate the performance of the proposed method in terms of steady-state accuracy and response to time-varying operating conditions. The proposed index can be used for billing purposes to control harmonic distortion levels in power systems.

사이크로이드 치형을 이용한 하모닉 감속기의 개발 (Development of harmonic drive using cycloide tooth profile)

  • 이종원;오세훈;김준철;전한수
    • 대한기계학회논문집A
    • /
    • 제21권7호
    • /
    • pp.1166-1173
    • /
    • 1997
  • Due to progress in manufacturing techniques, the performance of the harmonic drive has been improved but not sufficiently. One of the important problems which the current harmonic drive has is that while there is the potential for having a wider tooth contact area, the total number of teeth engaged simultaneously is still small. This is mainly due to the involute tooth profile. Hence, in this study, the cycloid-type tooth profile is developed to improve this problem. This paper represents the design methodology and performance evaluation f the cycloid-type harmonic drive. Cycloide tooth profile was derived by analyzing geometry of the tooth engagement and the contact mechanisms of the tooth which were examined and analyzed by load analysis. The stress due to elastic deformation of a flexspline was also obtained by approximate formula and computer analysis. Finally, the cycloid-type harmonic drive with 1:100 speed ratio was manufactured and the performance of the harmonic drive was evaluated.

Controllable Harmonic Generating Method for Harmonic Impedance Measurement of Traction Power Supply Systems Based on Phase Shifted PWM

  • Liu, Qiujiang;Wu, Mingli;Li, Jing;Zhang, Junqi
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1140-1153
    • /
    • 2018
  • The harmonic impedance characteristic of a traction power supply system (TPSS) is necessary for taking actions to suppress the high-order harmonic resonances caused by AC electric locomotives. This paper proposes a controllable harmonic generating method (CHGM) for measuring the TPSS harmonic impedance by injecting harmonic disturbances of different frequencies and amplitudes into the TPSS. This method applies phase shifted pulse-width modulation (PSPWM) and ensures that the undesired sideband harmonics can be negligible while the desired harmonic is both controllable and adjustable. Multiple harmonics can be emitted at the same time. The implementation of the method is also presented. Simulations are carried out to validate the performance of the proposed method. Finally, experimental results on a 5 H-bridge converters platform verified the effectiveness and feasibility of the proposed method.

Studies of Harmonic Performance on PBG Via Structures

  • Tong Ming-Sze;Kim Hyeong-Seok;Lu Yilong
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권2호
    • /
    • pp.81-85
    • /
    • 2005
  • This paper presents some interesting results regarding the harmonic performance on the photonic band-gap (PBG) structures formed by periodic conducting vias. Study on PBG structures has been one of the major topics in electromagnetics, microelectronics, and communications areas. In most of the studies, the band-gap filtering behavior was fulfilled by a periodic pattern of perforations on the ground planes of microstrip lines. Nevertheless, the PBG characteristics can also be realized using a periodic via-pattern along the transmission-line circuits. Hence, some of the via-typed PBG structures are studied and their frequency characteristics in terms of the scattering parameters are presented. It is found that by varying the length of vias with respect to the period pattern, different harmonic performances are observed.