• Title/Summary/Keyword: hard phase

Search Result 438, Processing Time 0.027 seconds

The Effects of Co-substitution on the Magnetic Properties of Nanocrystalline Nd-Fe-B based Alloy Containing α-Fe as Main Phase (Co 치환이 α-Fe기 초미세결정립 Nd-Fe-B계 합금의 자기특성에 미치는 영향)

  • Cho, D.H.;Cho, Y.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.1
    • /
    • pp.30-33
    • /
    • 2002
  • The Effects of Co-substitution in the nanocrystalline Nd-Fe-B-Mo-Cu alloys were investigated. $\alpha$-Fe based nanocrystalline Nd-Fe-B-Mo-Cu alloys were prepared by crystallization process of amorphous Nd-Fe-B-Mo-Cu alloy produced by rapid solidification process. The substitution of Co resulted in the decrease of grain size and improves the hard magnetic properties. The remanence, coercivity, and Curie temperature of nanocrystalline N $d_4$(F $e_{0.85}$ $Co_{0.15}$)$_{82}$ $B_{10}$M $o_3$Cu alloy showed more improved magnetic properties than those of Co-free alloy. The grain size was measured to be about 15 nm. The coercivity, remanence and maximum energy product were 239 kA/m, 1.41, and 103.5 kJ/ $m^3$, respectively, for the nanocrystalline N $d_4$(F $e_{0.85}$ $Co_{0.15}$)$_{82}$ $B_{10}$M $o_3$Cu alloy annealed for 0.6 ks at 640 $^{\circ}C$.

Wear Behaviors of WC-CoCr and WC-CrC-Ni Coatings Sprayed by HVOF (고속화염 용사법으로 제조된 WC-CoCr 코팅과 WC-CrC-Ni 코팅의 내마모 거동)

  • Lee, Seoung Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.204-211
    • /
    • 2020
  • The high-velocity oxy-fuel (HVOF) thermal spraying coating technique has been considered a promising replacement for traditional electrolytic hard chrome plating (EHC), which caused environmental pollution and lung cancer due to toxic Cr6+. In this paper, two types of cermet coatings were prepared by HVOF spraying: WC-CoCr and WC-CrC-Ni coatings. The produced coatings were analyzed extensively in terms of the micro-hardness, porosity, crystalline phase and microstructure using a hardness tester, optical microscopy, X-ray diffraction, and scanning electron microscopy (including energy dispersed spectroscopy (EDS)), respectively. The wear and friction behaviors of the coatings were evaluated comparatively by reciprocating sliding wear tests at 25 ℃, 250 ℃, and 450 ℃. The results revealed correlations among the microstructures, metallic binder matrixes, porosities, and wear performance of the coatings. For example, WC-CoCr coatings showed better sliding wear resistance than WC-CrC-Ni coatings, regardless of the test temperature due to the more homogeneous microstructure, Co-rich, Cr-rich metallic binder matrix, and lower porosity.

Random Access Phase Optimal Allocation Method Through Pattern Correction in WBAN (WBAN 환경에서 패턴 보정을 통한 임의접근구간 최적 할당 방법)

  • Lee, ChangHo;Kim, Kanghee;Kim, JiWon;Choi, SangBang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.92-105
    • /
    • 2015
  • WBAN (Wireless Body Area Network) is a network which is to consistently monitor body signals with implanted or attached sensor nodes. Especially, nodes that are used in medical services have to operate with low power consumption since they are hard to replace, and have to guarantee high data rate and low transmission delay for consistent signal monitor. In this paper, we propose an algorithm that aims to reduce transmission delay and power consumption, and guarantees stable throughput, by assuming the number of active nodes, and followed by dynamically adjusting the random access period and transmission possibilities in a superframe. The assumed number of active nodes may be incorrect since it only relies on the channel status of a previous superframe. Therefore, we assume the number of active nodes and define a pattern. And revise the number of the active nodes with the defined pattern. To evaluate the performance of the proposed algorithm, we have implemented a WBAN environment with the MATLAB. The simulation results show that the proposed algorithm provides better throughput, low power consumption, and low transmission delay when compared to the slotted ALOHA of the IEEE 802.15.6.

Dry etch of Ta thin film on MTJ stack in inductively coupled plasma (ICP를 이용한 MTJ stack 위의 Ta 박막의 식각 특성 연구)

  • Kim, Dong-Pyo;Woo, Jong-Chang;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.29-29
    • /
    • 2009
  • 현재 고집적 비휘발성 메모리 소자로는 MRAM (Magnetic Random Access Memory)과 PRAM (Phase Magnetic Random Access Memory)이 활발하게 미국과 일본, 한국 등에서 다양한 연구가 진행되어 오고 있다. 이 중에서 MRAM은 DRAM과 비슷한 10 ns의 빠른 읽기/쓰기 속도와 비휘발성 특성을 가지고 있으며, 전하를 저장할 커패시터가 필요 없고, 두 개의 자성충에 약 10 mA 정도의 전류를 가하면 그때 발생하는 약 10 Oe의 자장을 개개의 비트를 write하고, read 시에는 각 비트의 자기저항을 측정함으로써 데이터를 저장하고 읽을 있으므로, 고집적화가 가능성하다 [1]. 현재 우수한 박막 재료가 개발 되었으나, 고집적 MRAM 소자의 양산에는 해결 하여야 하는 문제점이 있다. 특히 다층 박막으로 구성되어 있으므로 식각 공정의 개발이 필수적이다. 지금까지 MRAM 재료의 식각은 주로 Ion milling, ICP, ECR등의 플라즈마 장치를 되었고, 식각 가스로는 할로겐 기체와 금속카보닐 형성을 위한 Co/$NH_3$$Ch_3OH$ 기체가 이용되고 있다. 그러나 할로겐 계열의 기체를 사용할 경우, 식각 부산물들의 높은 끓는점 때문에 식각 부산물이 박막의 표면에서 열적 탈착에 의하여 제거되지 않기 때문에 높은 에너지를 가지는 이온의 도움에 의한 식각이 필요하다. 또한 Cl 계열의 기체를 사용할 경우, 식각 공정 후, 시료가 대기에 노출되면 대기 중의 수분과 식각 부산물이 결합하여 부식 현상이 발생하게 된다. 그러므로 이를 방지하기 위한 추가 공정이 요구된다. 최근에는 부식 현상이 없고, MTJ 상부에 사용되는 Ta 또는 Ti Hard mask와의 높은 선택비를 가지는 $CH_3OH$ 또는 CO/$NH_3$가 사용되고 있다. 하부 박막에 따른 식각 특성에 연구와 다층의 박막의 식각 공정에 발생에 관한 발표는 거의 없다. MRAM을 양산에 적용하기 위하여서는 Main etch 공정에서 빠른 식각 공정이 필요하고, Over etch 공정에서 하부박막에 대한 높은 선택비가 요구된다. 그러므로 본 논문에서는 식각 변수에 따른 플라즈마 측정과 표면 반응을 비교하여 각 공정의 식각 메커니즘을 규명하고, Main Etch 공정에서는 $Cl_2$/Ar 또는 $BCl_3$/Ar 가스를 이용하여 식각 실험을 수행하고, Over etch 공정에는 낮은 Ta 박막 식각 속도를 가지는 $Ch_4/O_2$/Ar 또는 $Ch_3OH$/Ar 가스를 이용하고자 한다. 플라즈마 내의 식각종과 Ta 박막과의 반응을 XPS와 AES를 이용하여 분석하고, 식각 공정 변수에 따른 식각 속도, 식각 선택비와 식각 프로파일 변화를 SEM을 이용하여 관찰한다.

  • PDF

Study on the Soil Improvement in the Grassland II. Effects of the dolomite particles and the shell powder application on soil characteristics, dry matter yield and nutritive value of forages in sandy loam soil (초지에서 토양 개량에서 관한 연구 II. 사양토에서 도로마이트 입자도와 패각분 시용이 토양 특성과 목초의 수량 및 사료가치에 미치는 영향)

  • Lee, J.K.;Choi, S.S.;Kim, M.J.;Yoon, S.H.;Park, G.J.;Choi, K.C.;Lee, S.C.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.19 no.4
    • /
    • pp.373-378
    • /
    • 1999
  • This study was conducted to investigate the effects of application of the dolomite particles and the shell powder on soil characteristics, dry matter yield and nutritive value of forage in sandy loam soil at the Experimental Field of National Livestock Research Institute, Suweon, from 1994 to 1996. This was compared with control, lime, dolomite 0.5mm, 2.0mm, 4.0mm, and shell powder in mixed pasture. Although there was no significant difference, average dry matter yield for 3 years was increased with the application of lime, dolomite 2.0mm, 0.5mm, control, 4.0mm and shell powder in order. Average crude protein yield of forages was increased with the application of dolomite 2.0mm, 0.5mm, control, lime, shell powder and 4.0mm in order. Lime requirement was slightly increased from 2,410 to 4,853kg per ha with the lapse of time. Although soil hardness was optimum level by second year, it was apt to become hard little by little. Solid phase of soil was lowered with dolomite 0.5mm treatment. The results demonstrated that dolomite and shell powder could be settled a dust problem in farms and a coast pollution as lime substitutes for soil improvement. Therefore, it is desirable for dry matter yield and crude protein yield to applicate the dolomite 2.0mm every 3 years and the shell powder more frequently in sandy loam soil.

  • PDF

A Study of the Temperature Dependency for Photocatalytic VOC Degradation Chamber Test Under UVLED Irradiations (UVLED 광원을 이용한 광촉매 VOC 제거 특성 평가시 온도에 따른 농도 변화에 관한 연구)

  • Moon, Jiyeon;Lee, Kyusang;Kim, Seonmin
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.755-761
    • /
    • 2015
  • Photocatalytic VOCs removal test in gas phase is generally performed by placing the light source on the outside due to maintaining a constant temperature inside the test chamber. The distance between light source and photocatalysts is importantin the VOC degradation test since the intensity of light is rapidly decreased as the distance farther. Especially, for the choice of light source as UVLED, this issue is more critical because UVLED light source emits lots of heat and it is hard to measure the exact concentration of VOCs due to changed temperature in the test chamber. In this study, we modified VOC removal test chamber base on the protocol of air cleaner test and evaluated the efficiency of photocatalystunder UVLED irradiation. Photocatalystsof two different samples (commercial $TiO_2$ and the synthesized vanadium doped $TiO_2$) weretested for the p-xylene degradation in the closed chamber system and compared with each other in order to exclude any experimental uncertainties. During the VOC removal test, VOC concentrations were monitored and corrected at regular time intervals because the temperature in the chamber increases ${\sim}20^{\circ}C$ due tothe heat of UVLED. The results showed that theconversion ratio of p-xylene has 40~43% difference before and after the temperature correction. Based on those results, we conclude that the VOC concentration correction must be required for the VOC removal test in a closed chamber system under UVLED light source and obtained the corrected efficiencies of various photocatlysts.

A Method to Manage Faults in SOA using Autonomic Computing (자율 컴퓨팅을 적용한 SOA 서비스 결함 관리 기법)

  • Cheun, Du-Wan;Lee, Jae-Yoo;La, Hyun-Jung;Kim, Soo-Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.12
    • /
    • pp.716-730
    • /
    • 2008
  • In Service-Oriented Architecture (SOA), service providers develop and deploy reusable services on the repositories, and service consumers utilize blackbox form of services through their interfaces. Services are also highly evolvable and often heterogeneous. Due to these characteristics of the service, it is hard to manage the faults if faults occur on the services. Autonomic Computing (AC) is a way of designing systems which can manage themselves without direct human intervention. Applying the key disciplines of AC to service management is appealing since key technical issues for service management can be effectively resolved by AC. In this paper, we present a theoretical model, Symptom-Cause-Actuator (SCA), to enable autonomous service fault management in SOA. We derive SCA model from our rigorous observation on how physicians treat patients. In this paper, we first define a five-phase computing model and meta-model of SCA. And, we define a schema of SCA profile, which contains instances of symptoms, causes, actuators and their dependency values in a machine readable form. Then, we present detailed algorithms for the five phases that are used to manage faults the services. To show the applicability of our approach, we demonstrate the result of our case study for the domain of 'Flight Ticket Management Services'.

The Effect of Ionic Group and MMA Contents on the Physical Properties of PU/PMMA Hybrids (PU/PMMA Hybrids의 물성에 대한 이온성기와 MMA함량의 영향)

  • Jeong, Chang Nam;Cho, Hang Kyu;Noh, Si Tae
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.575-581
    • /
    • 1997
  • UDs were synthesized from two different polyols(PTMG, PBEAG), ionic chain extender(DMPA), EDA with $H_{12}-MDI$. PU/PMMA hybrids were prepared with free radical polymerization of MMA monomer in MMA-swelled PUD. PUD particle size and film properties were investigated ionic content and polyol type. Mechanical and thermal properties of PU/PMMA hybrid film were studied in terms of PU's ionic content and the venation of PU/PMMA compositions. As DMPA content increased from 2wt% to 10wt% in PUD, particle size of PUD decreased. PUD's particle size with ester type polyol was found to be smaller then ether type polyol used. Phase separation between hard segment(HS) and soft segment(SS) with ionic contents in PU was shown by the thermal, mechanical property measurement. Although the composition of MMA was changed from 0 to 40 wt% in PU/PMMA hybrid, the particle size of the hybrid did not increase. Using the ester type polyol, tensile strength of hybrid was found to increase by 2wt% - 6wt% DPMA content, but as higher content the strength of hybrid decreased. Moreover with the ether type polyol, tensile strength of hybrid was observed to increase by 2wt% - 4wt% DMPA content, while decreasing at higher content. PU and PMMA polymer molecule being mixed in molecular level was confirmed from the pattern of $T_g$ in DSC thermogram.

  • PDF

Learning Needs in Patients undergoing Bone Marrow Transplantation (골수이식환자의 교육요구도)

  • 최소은
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.2
    • /
    • pp.514-526
    • /
    • 2000
  • The active treatment phase in preparation for bone marrow transplantation(BMT) of che- motherapy regimen and total body irradiation (TBI) containing regimen requires considerable teaching. There have been researches that are related to treatment onto BMT patients and to psychological change during BMT process. However, it was hard to find researches focused on learning needs of patients undergoing BMT. The purpose of this study was to provide the basic data for effective educational program about BMT by investigating the learning needs in patients undergoing BMT. The subjects consisted of 90 BMT patients have been admitted to the department of BMT at three university hospitals. Data were obtained from October 1998 to March 1999 and analyzed by SAS program for unpaired t-test, ANOVA, Duncan test. The results were as follows : 1. Learning needs related to demographic characteristics was identified as below. That of male was higher than that of female. That of under age 29, unmarried, religious and university graduated group was higher than that of opposite group but it didn't show significant difference. Learning needs of group of patients who were employed was significantly higher then that of unemployed patients. 2. According to types of diagnosis, learning needs of myelodysplastic syndrome(MDS) patients was the higher than that of others, but admission frequency was the least. Learning needs of unrelated matched BMT(UBMT) patients was higher than that of autologous BMT patients. However, it didn't show significant difference. With regard to learning needs according to process of BMT, learning needs of Pre- BMT period or Post-BMT period was significantly higher than that of BMT day. 3. Learning needs related to BMT was relatively high (total mean: 3.11 of 4.0). The order of the mean score of leaning needs was shown as follows : Restricted activities after discharge, Relapse symptom, Complications of BMT, Kinds of available drugs at home. Therefore the learning needs that is related to life after discharge and to relapse and complications after BMT was high. 4. Learning needs related to radiation therapy was high (total mean: 3.35 of 4.0). The learning needs in radiation therapy items was the Skin care of radiation therapy and Purpose of radiation therapy. 5. Learning needs related to graft versus host disease(GVHD) therapy was high (total mean: 3.55 of 4.0). The highest learning needs in GVHD therapy items was the Preventive method GVHD. less admission frequency and UBMT patients. It is necessary that education for BMT patients should be focused on life after discharge and on relapse and complications after BMT. Especially education for allogeneic BMT patients should be emphasized on GVHD. For all of these, it is necessary to develop systematic and concrete educational program.

  • PDF

CLINICAL CONSIDERATION ON USING THE ELASTIC 'TIE BACKS' DURING SPACE CLOSURE ('Elastic tie back'을 이용한 발치공간 폐쇄에 관한 임상적 고려)

  • Cho, Ki-Soo;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.217-227
    • /
    • 1993
  • Preadjusted appliance, following the original concept of the Andrews Straight-Wire appliance, became increasingly common in the 1980s. In six phases of treatment, anchorage control, leveling and aligning, overbite control, overjet reduction, space closure, and finishing are very effective with using the preadjusted appliances. Space closure is the phase of treatment in which the difference between standard edgewise and preadjusted mechanics is most noticeable. Orthodontists have been able to reduce the use of closing loops and, because of the level slot lineup, enjoy the advantages of sliding mechanics. In 1990, Dr. John C. Bennett and Richard P. McLaughlin introduced the new space closure system, namely, elastic 'tiebacks'. They found an $.019'\times.025'$ working archwire most effective in an .022'-slot system. Hooks of .024' stainless steel or .028' brass wire are soldered to the upper and lower archwires. The force required for space closure is delivered by elastic 'tiebacks'. An elastic modulo stretched by 2-3mm(to twice its normal length) usually delivers 0.5-1.5mm of space closure per month. Group movement and sliding mechanics are combined for gentle, controlled space closure, so that about 0.5mm of incisor retraction and 0.5mm of mesial molar movement can be seen each month. The tiebacks are replaced every four to six weeks. By using the elastic 'tiebacks', the next two cases were treated during space closure. Even though we found some clinical problems of this mechanics, long treatment time, hard to control of vertical dimension and anchorage, the application method of this system is so simple that orthodontists can manage many patients during short chair time. But we must apply this mechanics after perfect understanding of the biomechanics in tooth movement.

  • PDF