• 제목/요약/키워드: handpiece

검색결과 99건 처리시간 0.036초

터빈 로터 반사각에 따른 의료용 에어터빈 핸드피스의 성능에 관한 수치 해석 (Numerical Analysis on Performance of Dental Air Turbine Handpiece for Various Reflection Angles of Turbine Rotor)

  • 이정호;이상도;김귀순
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.29-32
    • /
    • 2008
  • Dental high-speed air turbine handpieces have been used as a dental cutting tool in clinical dentistry for over 50 years, yet little study has been reported on their flow and performance analysis. Therefore it is necessary to investigate turbine for the performance improvements of an air turbine handpiece. This paper presents pressure on turbine rotor and flow analysis in air turbine handpiece using CFD (computational fluid dynamics). Characteristics on each flow and pressure for four various reflection angles of turbine rotor are presented, and then performance change is analyzed about air turbine handpieces by CFD results.

  • PDF

Design of Air Turbine and Air Bearing for Dental Handpiece

  • Hwang, Pyung;Park, Sang-Shin;Sohn, Jeong-L.;Kwon, Seong-In;Kim, Do-Hyung;Kim, Woo-Seok
    • Tribology and Lubricants
    • /
    • 제23권5호
    • /
    • pp.240-247
    • /
    • 2007
  • The design process of the dental handpiece is described. The parameters of the high speed air turbine are estimated. The effect of supply hole on the stiffuess and damping of the air bearing for handpiece is studied numerically. The Reynolds equation is solved by using the divergence formulation and the perturbation method. The test rig is built and the test procedure is developed for the turbine rotational speed measurement by using Fourier transform of noise generated by the turbine during steady operation.

치과용 초음파 수술기의 절삭성능 평가를 위한 핸드피스 이송 시스템 구축 (Development of Handpiece Moving System (HMS) for Cutting Performance Evaluation of Dental Ultrasonic Surgery Unit)

  • 사민우;심해리;고태조;이종민;김종영
    • 한국정밀공학회지
    • /
    • 제33권5호
    • /
    • pp.377-383
    • /
    • 2016
  • Recently, research on bone fracture and osteoplasty using ultrasonic bone surgery unit has been ongoing in the fields of dentistry, plastic surgery, and otorhinolaryngology. However, detailed data evaluation with ultrasonic bone surgery unit has not been conducted to date. In this study, we developed handpiece moving system (HMS) for cutting performance evaluation. In the experimental setup of HMS, a handpiece was immobilized, and bone samples from cortical bone of bovine leg were prepared. Also, the experimental process was described in detail, and a basic experiment was carried out to evaluate the cutting performance. Future study is required on all experimental process conditions by HMS.

핸드피스 분무조건에 따른 부유세균 기균(氣菌) 의 분포 (DISTRIBUTION OF AIRBORNE BACTERIA BY HANDPIECE AEROSOL CONDITIO)

  • 고영한;백병주;김재곤;양연미;신정근
    • 대한소아치과학회지
    • /
    • 제35권4호
    • /
    • pp.628-634
    • /
    • 2008
  • 최근 치과계에는 교차감염의 문제가 점차 대두되고 있으며, 그 감염경로에는 혈액이나 구강 분비물을 통한 직접접촉과 진료실 장비 등에 의한 간접접촉이 있다. 또한 병원 등 한정된 공간 내에 많은 인원이 수용된 환경에서는 공기 중을 떠다니는 오염물질에 의한 공기 감염에 보다 많은 관심이 모아지고 있으며, 치과 진료실에서는 고속회전 핸드피스에서 발생하는 분무에 의한 감염이 가장 우려되고 있는 상황이다.따라서 본 실험에서는 치과 진료실 내 핸드피스 분무에 의한 공기 중 세균 감염 위험성을 파악하고 실제 진료 시, 감염 방지에 도움을 주는데 그 목적을 두었으며, 다음과 같은 결론을 얻었다. 1. 핸드피스를 사용해 진료한 군 97.4 cfu, 핸드피스를 사용하지 않고 진료한 군 5.6 cfu로 핸드피스를 사용해서 진료한 군에서 박테리아 군집의 수가 높게 나타났으며 통계학적으로 유의한 차이를 보였다(P<0.01). 2. 핸드피스 사용 시 러버댐을 같이 사용한 진료는 22.4 cfu로 러버댐을 사용하지 않고 진료하는 경우보다 박테리아 군집의 수가 낮게 나타났으며,통계학적으로 유의한 차이를 보였다(P<0.01).3. 핸드피스 물 공급원으로 관주용액을 사용한 경우와 증류수를 사용한 경우를 비교 시 관주용액을 사용한 경우 cfu는 22.4 cfu, 증류수의 경우 17.0 cfu로 측정되었으나, 통계학적으로 유의한 차이를 보이지 않았다. (P>0.05). 4. 핸드피스를 사용해 진료하는 경우, 0.5m와 1.5m 거리에서 측정 시 97.4cfu와 22.0 cfu로 0.5m 거리에서 박테리아 군집의 수가 높게 나타났으며 통계학적으로 유의한 차이를 보였다(P<0.01). 또한 원거리에서도 핸드피스 분무에 의해 박테리아가 검출되었다. 5. 박테리아균을 분류한 결과 그램양성 구균의 수가 73.9%로 가장 많은 비중을 보였고, 그램음성 구균, 그램음성 간균, 그램양성 간균의 순이었다.

  • PDF

터빈 블레이드 형상에 따른 의료용 에어터빈 핸드피스의 성능 특성에 관한 수치적 연구 (Numerical Study on the Effect of Turbine Blade Shape on Performance Characteristics of a Dental Air Turbine Handpiece)

  • 이정호;김귀순
    • 한국추진공학회지
    • /
    • 제13권1호
    • /
    • pp.34-42
    • /
    • 2009
  • 의료용 고속 에어터빈 핸드피스는 치아 절삭 도구로써 지난 50년 동안 치의학분야에서 사용되어왔으나, 그것에 대한 성능 연구가 많이 없었다. 그래서 수치해석을 이용하여 핸드피스 터빈 형상의 성능 특성을 본 논문에서 연구하였다. 정상상태 방법 중 하나인 프로즌 로터 방식을 이용하여 터빈 블레이드의 위치에 따라 5가지의 경우에서 계산하였다. 형상과 반사각에 따른 터빈 블레이드의 특성을 분석하였다. 계산 결과에 따르면, 터빈 블레이드의 반사각이 증가할 때 토크가 증가하였다.

하악 제3대구치 발치 후 병발된 피하기종과 종격동 기종: 증례보고 (Subcutaneous Emphysema and Pneumomediastinum After Mandibular Third Molar Extraction: a Case Report)

  • 김덕실;김성완;변경환;김현수
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권6호
    • /
    • pp.597-599
    • /
    • 2010
  • Subcutaneous emphysema and pneumomediastium is a relatively uncommon phenomenon. Most case of pneumomediastium are caused by iatrogenic injury on the cervical region and chest during tracheostomy. It is also well known that emphysema may occur secondary to dental treatment using high-speed air turbine handpiece, but there have been few cases of emphysema extended to involving the mediastinum. These complications are reported to occur mainly in patients after dental procedures, in particular during mandibular third molar extraction. Early recognition and conservative treatment of these problems is essential in preventing life-threatening complications such as airway obstruction, mediastinitis, pneumothorax and cardiac failure. As we report a case of 25-year-old woman with subcutaneous emphysema and pneumomediastium after mandibular third molar extraction using high-speed air turbine handpiece.

터빈 형상에 따른 의료용 에어터빈 핸드피스의 유동분석 및 성능에 관한 수치적 연구 (Numerical Study on the Effect of Turbine Shape on the Flow Characteristics and Performance of Dental Air Turbine Handpiece)

  • 이정호;이상도;김귀순
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.5-8
    • /
    • 2008
  • 본 연구는 지난 연구에 이어서 핸드피스 터빈 형상에 따른 유동특성 및 성능을 수치해석을 이용하여 연구하였다. 정상상태 방법 중 하나인 프로즌 로터 방식을 이용하여 노즐 중심선과 터빈 로터사이의 여러 각도에 따라 계산하였다. 평평한 모양, 오목한 형상, 갈매기 모양 등 3가지 터빈 로터 형상의 특성을 분석하였다. 추가적으로, 가장 성능이 좋은 로터 모양에 있어서 다른 반사각으로 계산을 하였다.

  • PDF

Extensive Bilateral Subcutaneous Emphysema after Dental Treatment: Two Case Reports

  • Gyu-Beom Kwon;Chul-Hwan Kim ;Hae-Seo Park
    • Journal of Korean Dental Science
    • /
    • 제16권1호
    • /
    • pp.80-86
    • /
    • 2023
  • We report two rare cases of extensive bilateral subcutaneous emphysema that occurred during ordinary dental procedures. An air-driven high-speed handpiece, routinely used in dental procedures may cause subcutaneous emphysema when high pressure air is introduced into the loose connective tissues below the dermal layer. The first case occurred with surgical extraction of the lower third molar. The air introduced into the fascial spaces near the surgical field spread to the contralateral spaces, as well as the neck and chest areas. The second case also showed extensive bilateral subcutaneous emphysema caused by the introduction of compressed air from the handpiece during crown preparation without any invasive procedure. Cases where the emphysema extends beyond the treatment site to involve the contralateral cervicofacial areas have been rarely reported. Predicting the occurrence of subcutaneous emphysema is difficult, so it is important to exercise caution during routine dental treatment. If significant bilateral cervicofacial swelling is suspected to be due to subcutaneous emphysema, prompt diagnosis with securing the patient's airway will be necessary.

Pin장착시(裝着時)에 치질귀열(齒質龜裂)에 미치는 영향(影響)에 관(關)한 연구(硏究) (A STUDY OF THE CRAZING OF TOOTH STRUCTURE ASSOCIATED WITH PLACEMENT OF PINS)

  • 나영민;최호영;민병순;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제11권1호
    • /
    • pp.33-41
    • /
    • 1985
  • The purpose of this study was to determine the extent of tooth structure crazing when pinhole were drilled in dentin at various distances from the dentionenamel junction, and when pins were inserted by hand wrench and Auto-klutch handpiece. Sixty freshly extracted teeth were embedded in blocks of cold-curing acrylic resin to a level 1mm apical to the cementoenamel junction, the crown of the teeth were removed to a level 1.5mm coronal to the cementoenamel junction. After being sectioned, the cut surface of the teeth were smoothed, and they were divided into 4 groups. Group I : 4 pinholes were drilled with self-threading Minim spiral drill and pins were inserted with hand wrench in fifteen teeth. Group II : 4 pinholes were drilled with self-threading Minim spiral drill and pins were inserted with Auto-klutch handpiece in fifteen teeth. Group III : 4 pinholes were drilled with self-threading Regular spiral drill and pins were inserted with hand wrench in fifteen teeth. Group IV : 4 pinholes were drilled with self-threading Regular spiral drill and pins were inserted with Auto-klutch handpiece in fifteen teeth. The cut surface were then examined microscopically for the presence or absence of craze line. The results were as follows: 1. The self-threading Minim pin groups (Group I & II) produced less craze lines than did the self-threading Regular pin groups (Group III & IV). 2. In the self-threading Minim pin groups, there was more craze lines with hand wrench (Group I) than with Auto-klutch handpiece (Group 11). 3. In the self-threading Regular pin groups, there was more craze lines with hand wrench (Group III) than with Auto-klutch handpiece (Group IV). 4. Placement of the pinhole at 0.0mm from the dentionenamel junction produced more craze lines than placed at 0.5mm, 1.0mm (p<0.05), however there was no statistically significant between the 0.5mm and 1.0mm distance.

  • PDF