• 제목/요약/키워드: handpiece

검색결과 99건 처리시간 0.023초

골 절삭용 초음파 수술기의 실험적 평가에 관한 연구 (A Study about Experimental Evaluation of an Ultrasonic Surgery Unit for Bone-cutting)

  • 사민우;심해리;고태조;이종민;김종영
    • 한국기계가공학회지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2016
  • In the dentistry field, an ultrasonic surgery unit is widely used in bone cutting and scaling to reduce operation time and minimize hemorrhage. The purpose of this study was to evaluate bone cutting and the effect of a specimen's temperature on the two-type ultrasonic surgery unit using a handpiece moving system(HMS). A HMS, which can cut the bone, was developed to perform the experimental procedure with precision of motion control. Bone specimens were prepared from a combination of epoxy-hardener and cortical bone of bovine leg. Through the bone-cutting experiment, the cutting depth was evaluated by not only scanning electron microscopy, but also Vernier calipers. Also, the temperature distribution was measured by a thermo-graphic camera. This study may be applied methodically in various experimental evaluations on a performance test by a HMS.

치과용 초음파 스케일러/수술기 통합 시스템의 스케일링 및 절삭 시 온도 변화에 관한 연구 (A Study on Temperature Changes during Bone Scaling and Cutting of Dental Ultrasonic Scaling/Surgery System)

  • 사민우;고태조;김종영
    • 한국기계가공학회지
    • /
    • 제19권2호
    • /
    • pp.1-8
    • /
    • 2020
  • While dental clinics still use the ultrasonic scaling/surgery tool for teeth scaling and cleaning the tool's use is expanding steadily to include treatment of damaged teeth and bone tissue. In this study, a handpiece moving system (HMS) was developed to evaluate bone scaling and cutting in the field of dentistry. The HMS, through a scaling test of bone using a scaler tip, it was able to identify surface damage. Additionally, a thermos-graphic camera was used to observe the temperature distribution that occurred during the bone scaling and cutting process. Consequently, we found that increasing the working load increased the amount of surface damage. Changes in temperature distribution occurred slowly and were maintained within safety bounds for 10 minutes. Going forward, we will compare the HMS performance on scaling and cutting with other devices.

핸드피스용 BLDC 모터 속도 제어시스템의 설계 (Design of Brushless DC Motor Speed Control System for Handpieces)

  • 곽성우;양정민
    • 한국전자통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.597-604
    • /
    • 2016
  • 본 논문에서는 미용 목적의 핸드피스에 사용가능한 BLDC 모터의 속도 제어 시스템을 구현한다. 저비용 개발을 위해 모터 내부의 홀 센서 값을 속도 제어에 이용하였다. 모터 전원 회로와 드라이버 회로는 가정용 220V 전원을 입력으로 사용하도록 설계하였으며 별도의 다른 전원은 필요로 하지 않는다. 핸드피스 작업 시 발생하는 부하 변동에 따른 급속한 속도 증가를 방지하기 위해 별도의 과속 방지 제어기를 탑재하였다. 개발된 제어 시스템은 5,000~30,000 RPM 구간에서 운용 가능하다. 본 연구에서 개발된 핸드피스 모듈에서 부하 변동이 있음에도 불구하고 모터의 속도가 일정하게 유지됨을 실험으로 입증한다.

Effects of auditory feedback and task difficulty on the cognitive load and virtual presence in a virtual reality dental simulation

  • Kim, Byunggee;Yang, Eunbyul;Choi, Namki;Kim, Seonmi;Ryu, Jeeheon
    • 대한치과의사협회지
    • /
    • 제58권11호
    • /
    • pp.670-682
    • /
    • 2020
  • This research examined the difference in cognitive load and the virtual presence depending on auditory feedback and task difficulty in haptic-based dental simulation. In the field of dental education, practice-centered training using handpiece has been crucial because a practitioner's psychomotor experience has a significant impact on the mastery of treatment skills. For the novice, it is necessary to reduce errors in dental treatment to enhancing skill acquisition in the haptic practice. In the training process, the force-feedback is crucial to elaborate subtle movement to guide what to do and how it should be hard or soft. However, It is not easy to add force-feedback to generate kinetic experience training. As an alternative method, we examined that auditory feedback can help learners' skill training. In this study, we analyzed how the presence/absence of auditory feedback at the different levels of task difficulty impacts learners' psychological demand and virtual presence in the virtual reality simulation. For this study, 29 dental college students participated in a dental simulation. The participants were grouped into two conditions that are with and without auditory feedback. Additionally, two consecutive tooth preparation tasks with different levels of difficulty were used in the simulation. The auditory feedback condition gives alarms to a learner when he treats a non-targeted tooth with a virtual handpiece. The user's cognitive load and virtual presence were measured to examine the effects of auditory feedback. The results revealed that the main effect was found in cognitive loads. Also, a significant interaction effect was shown in the virtual presence. We discussed the effective design methods for the virtual reality-based dental simulation through the result of this study.

  • PDF

초음파 수술기의 수술 효율성 향상을 위한 진동자 임피던스 측정에 따른 조직 분류 연구 (Classification of Organs Using Impedance of Ultrasonic Surgical Knife to improve Surgical Efficiency)

  • 김홍래;김성천;김광기;김영우
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.141-147
    • /
    • 2013
  • Ultrasonic shears is currently in wide use as an energy device for minimal invasive surgery. There is an advantage of minimizing the carbonization behavior of the tissue due to the vibrational energy transfer system of the transducer by applying a piezoelectric ceramic. However, the vibrational energy transfer system has a pitfall in energy consumption. When the movement of the forceps is interrupted by the tissue, the horn which transfers the vibrational energy of the transducer will be affected. A study was performed to recognize different tissues by measuring the impedance of the transducer of the ultrasonic shears in order to find the factor of energy consumption according to the tissue. In the first stage of the study, the voltage and current of the transducer connecting portion were measured, along with the phase changes. Subsequently, in the second stage, the impedance of the transducer was directly measured. In the final stage, using the handpiece, we grasped the tissue and observed the impedance differences appeared in the transducer To verify the proposed tissue distinguishing method, we used the handpiece to apply a force between 5N and 10N to pork while increasing the value of the impedance of the transducer from 400 ${\Omega}$.. It was found that fat and skin tissue, tendon, liver and protein all have different impedance values of 420 ${\Omega}$, 490 ${\Omega}$, 530 ${\Omega}$, and 580 ${\Omega}$, respectively. Thus, the impedance value can be used to distinguish the type of tissues grasped by the forceps. In the future study, this relationship will be used to improve the energy efficiency of ultrasonic shears.

치아인접면 삭제 및 연마에 따른 법랑질 표면의 변화에 관한 주사전자현미경적 연구 (A SCANNING ELECTRON MICROSCOPIC STUDY ON CHANGES OF ENAMEL SURFACE BY INTERPROXIMAL STRIPPING AND POLISHING)

  • 김영순;김광원
    • 대한치과교정학회지
    • /
    • 제22권1호
    • /
    • pp.123-131
    • /
    • 1992
  • This study was done to evaluate the changes of enamel surface by interproximal stripping and recovery of it by polishing. The number of 34 1st premolars which had extracted for orthodontic treatment were selected as samples. Interproximal stripping was performed by hand with metal strip and strip placer (Dentaurum Co., Germany) and low speed handpiece with diamond disk (Superdiaflex, Germany). Polishing was performed by hand with plastic strip (3M Col) and low speed handpiece with whip-mix, DCPA (Dicalcium Phosphate, Anhydrous, $CaHPO_4$) powder and Sof-lex (3M Co. U.S.A.) polishing kit. Each groups were examined under the scanning electron microscope (JEOL Co., JSM-840A, Japan) and the following results were obtained: 1. The stripped group performed by metal strip and diamond disk altogether showed deep furrow on the enamel surface as wide as about $10{{\mu}m}$. 2. There could be seen more irregular scratched line in the group stripped by metal strip than that by diamond disk. 3. The polished group performed by plastic strip and DCPA powder showed slight smoothening of the edge of stripped furrow on the enamel surface without relation to the stripping method. 4. The polished group performed by Sof-lex progressive polishing kit could not avoid the formation of the furrows on the enamel surface according to the particle size without relation to the stripping method. 5. The polished group performed by the superfine polishing wheel, the final stage of Sof-lex polishing method showed shallow scratched line as wide as within about $2{{\mu}m}$ on the enamel surface without relation to the stripping method. 6. The interproximal stripped enamel surface could not recover its original surface texture by any kind of polishing methods.

  • PDF

Glass ionomer cement를 이장한 Composite resin의 변연 적합성에 관한 연구 (MARGINAL ADAPTATION OF COMPOSITE RESIN USING GLASS IONOMER CEMENT BASES)

  • 한승원
    • Restorative Dentistry and Endodontics
    • /
    • 제14권2호
    • /
    • pp.5-19
    • /
    • 1989
  • The purpose of this study was to observe the microleakage of composite resin filling using several glass ionomer cements. The Class V cavities of eighty noncarious human molars were prepared at the cementoenamel juction on the facial and lingual surfaces of each tooth with a No.330 carbide bur in a high speed handpiece. The cavity dimensions were $3.0{\pm}0.5mm$ wide, $2.0{\pm}0.5mm$ high, and $1.5{\pm}0.5mm$ deep and all enamel cavosurface margins were beveled with a No.558 carbide bur in low speed handpiece. The bevel was approximately $45^{\circ}$ and 0.5-1.0mm in width. A total of the 160 cavities was divided into four groups, and then 144 cavities among them were three experimental groups and remaining sixteen cavities were control group. All of the prepared cavities were restored as follows: group 1 : Preparations were restored with there three glass ionomer cements. group 2 : Preparations were restored with a composite resin with three glass ionomer cement bases placed $0.2{\pm}0.1mm$ short of the cavosurface margin. group 3 : Preparations were restored with a composite resin with three glass ionomer cement bases extened to the cavosurface margin. group 4 : As control group, preparations were restored with a composite resin, PALFIQUE. The specimens were then thermocycled in a range of $6^{\circ}C-60^{\circ}C$ and immersed in a bath of 2.0% aqueous basic fuchsin solution for 24 hours. Dye penetration was read on a scale of 0 to 4 by Tani and Buonocore's method. The following conclusions were derived from the results obtained; 1. All groups showed significantly more leakage at the gingival margins than at the occlusal margins(p<0.0005). 2. At the gingival margins, group 1 showed less leakage than group 3(p<0.01) and group 4(p<0.0005), while group 3 exhibited less leakage than group 2(p<0.01) and group 4(p<0.0005). 3. At the occlusal margins, group 4 showed less leakage than group 3(p<0.1) and group 1(p<0.005), while group 3 exhibited less leakage than group 2(p>0.1) and group 1(p<0.025).

  • PDF

지르코니아의 소결 후 특성 (Surface Characteristics of Ground and Post-Sintered Zirconia)

  • 김민정;김임선;최병환;김원기
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.157-163
    • /
    • 2016
  • Purpose: It is to compare and evaluate the change of the wear rate and phase variation of the Zirconia before and after the sintering after the grinding by a high speed equipment manufactured for the Zirconia. Methods: The specimen of the sintered Zirconia was manufactured as size of $15mm{\times}15mm{\times}2mm$. The grinding has been applied to each of all pieces of each test groups for a minute fit for each condition at same speed of 50,000 rpm by a diamond bur at high speed handpiece with injection of the air and water. For the observation of the surface before and after the sintering of the each test piece, the cross section of it was observed as 100 magnification by a scanning electron microscope after it was coated by PT, and the diffraction analysis was performed by XDR to compare the crystal phase of the Zirconia. The average surface roughness value of all specimens were evaluated. The wear test was performed at room temperature by applying a load of 1kg for 120,000 cycles for the chewing period 6 months. Wear was analyzed for the enamel cusps by measurement of the vertical substance loss with a laser scanner. Conclusion: The phase variation from the tetragonal phase to the monoclinic phase was confirmed in the test group of the pre-sintered Zirconia after the grinding, and the value of the surface roughness and the wear rate was increased in experimental group.

수종수복용 Pin의 유지력에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON RETENTIVE PROPERTIES OF VARIOUS PINS IN DENTIM)

  • 이명종
    • 대한치과의사협회지
    • /
    • 제15권11호
    • /
    • pp.763-766
    • /
    • 1977
  • The Purpose of this study was to observe force required to remove some kinds of pin from dentin. The teeth were embedded within a resin cylinder and the occlusal surface was sectioned at a right angle to the axis of the cylinder to expose dentin surface. Thread mate system pin (minim and regular), friction Iocked pin and cemented pin were tested Pin holes were drilled by handpiece and depths of pin holes were tested 1,2 and 3mm. After insertion of the pins into pinhole, tensile loading was performed on the Instron testing machine at the speed of 0.5 inch/min. Results were follewed: 1. In retention, the cemented pins are the least, the friction locked pins intermediate and the self threading pins the greatest in all pins. In self threading pins, regalar pin has greater retention than minim pin 2. The deeper the depth of the pin hole is, the more the retention of the pin increases.

  • PDF

Subcutaneous emphysema during removal of suture after intraoral surgery

  • Park, Jong-Chan;Shin, Hyeon-Seo;Son, Jeong-Wan;Lee, Jun;Kim, Bong-Chul;Lim, Hun-Jun
    • 대한치과의사협회지
    • /
    • 제56권8호
    • /
    • pp.418-422
    • /
    • 2018
  • Subcutaneous emphysema is relatively rare postoperative complication in the oral and maxillofacial region. Most cases reported in maxillofacial area relate to the use of high-speed handpiece. However, in this case, subcutaneous emphysema was caused by compressed air blow performed during suture removal. Cone-Beam Computed Tomography was conducted to evaluate the extent of diffusion bubbles.. In this report, we describe etiology, diagnosis, prevention and management of subcutaneous emphysema in the maxillofacial area.

  • PDF