• Title/Summary/Keyword: handheld Probe

Search Result 8, Processing Time 0.025 seconds

Development of a Handheld Sheet Resistance Meter with the Dual-configuration Four-point Probe Method

  • Kang, Jeon-Hong;Lee, Sang-Hwa;Yu, Kwang-Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1314-1319
    • /
    • 2017
  • A handheld sheet resistance meter that can easily and quickly measure the sheet resistance of indium tin oxide films was developed. The dual-configuration four-point probe method was adopted for this instrument, which measured sheet resistance in the range from $0.26{\Omega}/sq$. to $2.6k{\Omega}/sq$. with 0.3 % ~ 0.5 % uncertainty. The screen of the instrument displayed the sheet resistance when the probe was in contact with the sample surface and the value continued to be displayed during the probe contact. Even after separating the probe from the surface, the value was still displayed on the screen and could be read easily. A feature of the instrument was the use of the dual-configuration technique to reduce edge effects markedly compared with the single-configuration technique and its ease of operation without applying correction factors for sample size and thickness.

Handheld OCT probe for Evaluation of Tympanic Membrane Status (OCT용 손잡이 형 프로브를 이용한 고막 상태 평가)

  • Kwon, Hyeong-Il;Kim, Yee-Hyuk;Cho, Nam-Hyun;Jeong, Hyo-Sang;Kim, Jee-Hyun;Lee, Sang-Heun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.4
    • /
    • pp.285-288
    • /
    • 2011
  • In this study, we developed an optical coherence tomography(OCT) using a sweep-source laser whose center wavelength is 1310 nm and a probe of hand-held type. The developed hand-held probe targets to diagnose the middle ear, so it is miniaturized for ease and convenience of control. For the first time, we performed in-vivo clinical experiments on tympanic membrane(TM) perforation patients not reported from previous studies about OCT. The high-resolution sectional images of tympanic membrane perforation can be obtained. There aren't many studies about diagnostic instrument of the middle ear and diagnosis with sectional image of the middle ear, so the developed OCT system and hand-held probe are applicable to tympanic membrane perforation and other pathologic diagnosis in the middle ear.

Development of SD-OCT for Imaging the in vivo Human Tympanic Membrane

  • Cho, Nam-Hyun;Jung, Un-Sang;Kwon, Hyeong-Il;Jeong, Hyo-Sang;Kim, Jee-Hyun
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.74-77
    • /
    • 2011
  • We report a novel extension of 840 nm wavelength- based spectral domain optical tomography to in vivo/real-time human middle ear diagnosis. The system was designed to access the middle ear region with a specifically dedicated handheld probe. The real-time displaying feature was mandatory for in vivo imaging human subject with the handheld probe, and the system could provide about 20 frames per second for 2048 pixels by 1000 A-scans without using any graphics process units under the Labview platform. The inner ear structure of a healthy male volunteer was imaged with the developed system with the axial and lateral resolutions of $15\;{\mu}m$ and $30\;{\mu}m$, respectively. The application of the OCT technology to early diagnose otitis media(OM) is very promising and could be another extensive branch in the OCT field because it provides the depth resolved image including tympanic membrane (TM) and structures below TM whereas the conventional otoscope technique only gives asurface image of the TM.

RELIABILITY and VALIDITY of DUAL PROBE-FIXING FRAME for REHABILITATIVE ULTRASOUND IMAGING for EXERCISES with VISUAL FEEDBACK

  • Na-eun Byeon;Jang-hoon Shin;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.259-267
    • /
    • 2023
  • Objective: Rehabilitative ultrasound imaging is a safe and noninvasive technique for evaluating muscle thickness. A dual probe-fixing frame (DPF) can provide visual feedback during exercises targeting specific muscles. The purpose of this research was to verify the reliability and validity of the DPF for dual-probe ultrasound (DPU)-based visual feedback exercises, allowing users to use both hands freely. Design: This cross-sectional study used repeated measures to compare muscle thickness measurements obtained using the handheld device and DPF with DPU. Methods: Twenty healthy adults participated in the study. Measurements were taken over two sessions, with a two-day interval between the sessions. The thicknesses of the rectus abdominis (RA) and transverse abdominis (TrA) muscles were measured using DPU. The DPF with DPU developed by the research team, was used along with a laptop-based muscle viewer. Bland-Altman analysis and intraclass correlation coefficients (ICCs) calculations were used in statistical analyses to evaluate agreement and reliability, respectively. Results: The results of the Bland-Altman analysis showed small average differences between the handheld and DPF methods for both RA and TrA muscle thicknesses. Inter-rater reliability analysis showed high ICC values for DPF measurements of both RA (0.908-0.912) and TrA (0.892-741) muscle thicknesses. Intra-rater reliability analysis also showed good ICC values for measurements taken by a single examiner over two days. Conclusion: The findings of this study demonstrate that the DPF provides reliable and valid measurements of muscle thickness during visual feedback exercises using the DPU.

A Handheld Probe Based Optical Coherence Tomography System for Diagnosis of Dental Calculus (치석 진단용 소형 프로브 기반 광간섭단층촬영 시스템)

  • Lee, Chang-Ho;Woo, Chai-Kyoung;Jung, Woong-Gyu;Kang, Hyun-Wook;Oh, Jung-Hwan;Kim, Jee-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.217-222
    • /
    • 2012
  • Optical coherence tomography(OCT) is a noninvasive optical imaging tool for biomedical applications. OCT can provide depth resolved two/three dimensional morphological images on biological samples. In this paper, we integrated an OCT system that was composed of an SLED(Superluminescent Light Emitting Diode, ${\lambda}_0$=1305 nm bandwith= 141 nm), a reference arm adopting a rapid scanning optical delay line(RSOD) to get high speed imaging, and a sample arm that used a micro electro mechanical systems(MEMS) scanning mirror. The sample arm contained a compact probe for imaging dental structures. The performance of the system was evaluated by imaging in-vivo human teeth with dental calculus, and the results indicated distinct appearance of dental calculus from enamel, gum or decayed teeth. The developed probe and system could successfully confirm the presence of dental calculus with a very high spatial resolution($6{\mu}m$).

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.

Toxicological Investigation of Radioactive Uranium in Seawater

  • Ly, Suw-Young;Bae, Jeong-Mi;Kim, Jin
    • Toxicological Research
    • /
    • v.28 no.1
    • /
    • pp.67-71
    • /
    • 2012
  • Trace uranium detection measurement was performed using DNA immobilized on a graphite pencil electrode(DGE). The developed probe was connected to the portable handheld voltammetric systems used for seawater analysis. The sensitive voltammogram was obtained within only 30 s accumulation time, and the anodic stripping working range was attained at 100~800 ${\mu}g/l$ U and 10~50 ${\mu}g/l$. The statistic relative standard deviation of 30.0 mg/l with the $15^{th}$ stripping was 0.2115. Here, toxicological and analytical application was performed in the seawater survey in a contaminated power plant controlling water. The results were found to be applicable for real-time toxicological assay for trace control.

Sentinel Lymph Node Identification Using $^{99m}Tc$-Neomannosyl Human Serum Albumin in Esophageal Cancer; Comparison with $^{99m}Tc$-Phytate (식도암 환자에서 $^{99m}Tc$-Neomannosyl Human Serum Albumin과 $^{99m}Tc$-Phytate를 이용한 감시림프절 탐색의 비교)

  • Kim, Hyun-Koo;Kang, Du-Young;Kim, Seung-Eun;Park, Jong-Jae;Jeong, Jae-Min;Mok, Young-Jae;Choi, Young-Ho
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.2
    • /
    • pp.109-114
    • /
    • 2010
  • Background: The aim of this study was to compare a novel mannose receptor-binding agent(Technetium-99m human serum albumin, $^{99m}Tc$-MSA) with $^{99m}Tc$-phytate for sentinel node mapping in patients with esophageal cancer. Material and Method: Twenty patients with clinical stage T1N0m0 or T2N0M0 esophageal cancer that were candidates for esophagectomy were enrolled. Endoscopic injection of $^{99m}Tc$-MSA or $^{99m}Tc$-phytate was administered at the peri-tumor region before surgery in 10 patients. The radioactive lymph nodes were identified with a handheld gamma probe after lymph node dissection. Results: The patient's age and the sex ratio of both groups were similar. The clinical stage, tumor location, and operative technique did not differ. The total number of dissected lymph nodes did not differ ($28.5{\pm}9.12$ in MSA group, $32.2{\pm}11.24$ in phytate group, p=0.430). The sentinel node was identified in all cases in both groups. The number of sentinel nodes per patient was $2.7{\pm}1.57$ in the MSA group, which was significantly greater than the $1.7{\pm}0.88$ in the phytate group (p=0.036). Five out of 20 patients whose sentinel nodes could be identified had metastases; however, neither group had any false-negative results for sentinel node identification. Conclusion: Sentinel nodes were detected more frequently with MSA than with phytate.

  • PDF