• Title/Summary/Keyword: hand strength

Search Result 1,509, Processing Time 0.027 seconds

Graft Considerations for Successful Anterior Cruciate Ligament Reconstruction (성공적인 전방십자인대 재건술을 위한 적절한 이식건의 선택)

  • Kyung, Hee-Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.14-25
    • /
    • 2021
  • Several factors need to be considered for a successful anterior cruciate ligament (ACL) reconstruction, such as preoperative planning, operation technique, and postoperative rehabilitation. Graft choice, fixation, preparation method, maturation, incorporation to host bone, and graft tension should also be considered to achieve a good outcome after an ACL reconstruction. Factors to consider when selecting a graft are the graft strength, graft fixation, fixation site healing, and donor site morbidity, as well as the effects of initial strength, size, surface area, and origin of the graft on its potential for weakening during healing. There are two types of graft for an ACL reconstruction, autograft or allograft. Several autografts have been introduced, including the bone-patellar tendon-bone, hamstring tendon, and quadriceps tendon-bone. On the other hand, each has its advantages and disadvantages. The recent increased use of allografts for an ACL reconstruction is the lack of donor site morbidity, decreased surgical time, diminished postoperative pain, and good availability of source. Despite this, there are no reports suggesting that an allograft may have a better long-term outcome than an autograft. Allografts have inherent disadvantages, including a longer and less complete course of incorporation, remodeling, biomechanically inferiority to autograft, the potential risk of an immunogenic reaction and disease transmission. Higher long-term failure rates and poorer graft maturation scores were reported for allografts compared to autografts. An autograft in an ACL reconstruction should remain the gold standard, although the allograft is a reasonable alternative. If adequate length and diameter of autograft can be obtained for an ACL reconstruction, an autograft with adequate graft fixation and postoperative rehabilitation should be chosen instead of an allograft to achieve better results.

Literature review on the experimental method and interpretation of the edge chipping test (ECT) (Edge chipping test (ECT)의 실험방법과 해석에 관한 문헌고찰)

  • Song, Min-Gyu;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.9-18
    • /
    • 2022
  • In vitro studies are essential to predict the clinical performance of ceramic widely used as restorative materials. Traditional experiments such as fracture toughness and flexural strength have been used to evaluate the properties of brittle ceramics. However, these experiments have a limitation that the load conditions, failure patterns, and load values at which failure occurs are not similar to human occlusal force ranges or clinical failures. On the other hand, the edge chipping test (ECT), which was recently introduced to study chipping fracture of ceramics, has similar failure patterns to clinical trials. In addition, the failure loads from ECT were similar to human occlusal force. ECT can be usefully used in the study of ceramic properties. In this literature review, a more clinically meaningful experimental study of ceramics by examining the meaning and limitations of traditional ceramic failure tests and comparing them with ECT.

The effect of oral glucose tolerance testing on changes in arterial stiffness and blood pressure in elderly women with hypertension and relationships between the stage of diabetes and physical fitness levels

  • Lee, Jaesong;Park, Wonil;Sung, Eunsook;Kim, Bokbeom;Kim, Nahyun;Park, Saejong;Shin, Chulho;Park, Jonghoon
    • Korean Journal of Exercise Nutrition
    • /
    • v.24 no.4
    • /
    • pp.34-43
    • /
    • 2020
  • [Purpose] The purpose of this study was to assess changes in blood glucose level, blood pressure, and arterial stiffness after a 75 g oral glucose tolerance test (OGTT) in elderly women aged over 65 years with hypertension and either normal glycemic control, impaired fasting glucose tolerance, or diabetes mellitus. We also wished to investigate the relationship between stages of diabetes and physical fitness. [Methods] A total of 24 elderly women with hypertension were assigned to a control group (CON; n=7), impaired fasting glucose group (IFG; n=9), and diabetes mellitus group (DM; n=8). In each group, blood glucose level, brachial ankle pulse wave velocity (PWV), and blood pressure were measured at baseline as well as 60 and 120 minutes after a 75 g OGTT. Physical fitness factors such as hand grip strength, balance test, 4 m gait speed test, chair stand test, short physical performance battery, and 6-minute walking test were subsequently assessed. [Results] In all three groups, blood glucose levels were significantly increased at 60 and 120 minutes after a 75 g OGTT. In the DM group, blood glucose levels were significantly higher before and after a 75 g OGTT than in the CON group. In the CON group, PWV was significantly increased at 60 minutes after a 75 g OGTT; however, there were no changes in other groups after glucose ingestion. In the CON group, systolic and diastolic blood pressures were significantly decreased at 60 and 120 minutes after a 75 g OGTT compared to baseline. However, there was no change in blood pressure after ingestion in the DM group. The IFG group had greater grip strength than the CON group; however, there were no differences in other variables between the groups. [Conclusion] After a 75 g OGTT, elderly women with hypertension and diabetes maintain higher blood glucose levels compared to those with hypertension alone. Unlike elderly women with hypertension alone, those with hypertension and diabetes did not show changes in arterial stiffness and blood pressure after a 75 g OGTT. Therefore, elderly women with hypertension and diabetes may not be able to control their blood vessels following a 75 g OGTT due to impaired vascular endothelial function. Moreover, there was no association between diabetes stage and physical fitness in elderly women with hypertension.

Erosion Characteristics of TGase-added Biopolymers (TGase 첨가 바이오폴리머의 침식특성 연구)

  • Kanghyun Kim;Seunghyun Kim;Dohee Kim;Jongho Shin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.9
    • /
    • pp.5-13
    • /
    • 2023
  • Cement-based reinforcement materials, which are representative slope reinforcement materials, can cause contamination of ground and groundwater when ground injection or surface application is applied. Accordingly, slope reinforcement materials using eco-friendly biopolymers are attracting attention as a means of replacing existing materials, but the biopolymers currently used are easily dissolved when exposed to groundwater or rainfall environments, reducing strength. In order to solve this problem, the cross-linking of protein between sodium casein and Transglutaminase (TGase, C20H16N4O2S2) was used to increase the water resistance of biopolymers, and a rainfall slope test was conducted to evaluate their usability and applicability as a slope reinforcing material. In the case of reinforcement with only sodium casein, the precipitation dissolved sodium casein, and the slope was completely destroyed in 1 hour. On the other hand, it was observed that the slope reinforced by adding a small amount of TGase (0.5%) do not collapse even after 80 hours of rainfall duration due to increased water resistance. Strength and water resistance increases due to the addition of a small amount of TGase, and its applicability as an eco-friendly reinforcement is confirmed.

Interfacial and Durability Evaluation of Jute and Hemp Fiber/Polypropylene Composites Using Micromechanical Test and Acoustic Emission (미세역학적시험법과 음향방출을 이용한 Jute 및 Hemp 섬유/폴리프로필렌 복합재료의 내구성 및 계면 평가)

  • Kim, Pyung-Gee;Jang, Jung-Hoon;Kim, Sung-Ju;Hwang, Byung-Sun;Park, Joung-Man
    • Composites Research
    • /
    • v.20 no.3
    • /
    • pp.55-62
    • /
    • 2007
  • Interfacial evaluation and durability of Jute and Hemp fibers/polypropylene (PP) composites were investigated. Moisture content of various treated conditions were measured by thermogravimetic analyzer (TGA). After boiling water test, mechanical properties and IFSS between Jute, Hemp fibers and PP matrix decreased. On the other hand, work of adhesion increased due to swelled fibril by water. Surface energies of Jute and Hemp fibers before and after boiling water test were obtained using dynamic contact angle measurement. IFSS was not always consistent with thermodynamic work of adhesion. In boiling water case, since Jute and Hemp fibers could be swelled by water, surface area and moisture infiltration space increased. Environmental effect on microfailure modes of Jute or Hemp fibers and Jute or Hemp fibers/PP composites were obtained by observing via optical microscope and by monitoring acoustic emission (AE) events and their AE parameters. After boiling water test, unlike Hemp fiber, microfailure process of Jute fiber could occur due to low tensile strength by swelled fibril. In addition, AE events occurred more and AE amplitude and energy became lower than those of before boiling water test.

A Study on the Flame Retardant Properties of EPDM Rubber Mixed with Phosphorus and Halogen Compound (인 및 할로겐 함유 EPDM 고무 혼합물의 난연 특성에 관한 연구)

  • Choi, Seong Su;Im, Wan-Bin;Kim, Jin Hong;Park, Young-ae W.;Woo, Je-Wan
    • Elastomers and Composites
    • /
    • v.37 no.4
    • /
    • pp.224-233
    • /
    • 2002
  • This study has investigated the flame retardant properties of EPDM rubber with the addition of various flame retardants. Carbon black, stearic acid, zinc oxide cross-linking agent were mixed with EPDM rubber to produce the base rubber E0 without the addition of flame retardants. Phosphorus flame retardant Tricrecyl phosphate(TCP) was added to E0 in 0.5, 1, 1.5, 2 phr to make E1~E4 samples and red phosphorus was added in 3, 6, 9, 12 phr to make E5~E8 samples. A flame retardant of the bromine family Decabromodiphenyloxide(DBDPO), and a chlorinated paraffin retardant of the chlorine family was added to E0 in 3, 6, 9, 12 phr to make E9~E12 and E13~E16 samples, repectively. Basic physical properties such as tensile strength, tear strength and hardness were measured for all the rubber samples with various flame retardant additions. There was no substantial differences. On the other hand, Oxygen index and UL94 were measured to study flame retardant properties. From oxygen index measurements E0 sample showed a value of 23.5%, indicating the improvement of flame retardant properties. Also from UL94 measurements, it was found that addition of red phosphorus resulted in maximum flame retardant effect. It was found that increasing the amount of addition resulted in decreasing combustion rate and improving flame retardant effect regardless of the kind of flame retardant.

An Evaluation of Crack Resistance for Slag Asphalt Concrete Mixture Using Steel Slag Aggregates (제강슬래그 골재를 사용한 슬래그 아스팔트 혼합물의 균열저항성 평가)

  • Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • With the continuous industrial development, not only natural resource depletion, waste generation, but also various weather conditions are becoming more frequent. Efforts are continuing to recycle industrial by-products to overcome the climate crisis and save resources. Slag is a representative by-product generated in the steel industry, and it is characterized by improving rutting resistance and moisture sensitivity by increasing strength and reducing deformation when used as a material for asphalt concrete. On the other hand, slag has expansion properties so it is used as a relatively low-value-added material such as embankment and refilling materials. In order to expand the application of slag, an experiment was conducted to evaluate the crack resistance of slag asphalt concrete pavement. As a result of the indirect tensile strength test, it was found that the asphalt mixture using slag aggregate showed a value 1.13 times higher than that of the general HMA with the same particle size, and the toughness was 1.17 units, improving crack resistance. In addition, it was found that the failure number of the 4-point beam fatigue experiment and the slag asphalt mixture was 20,409, which was more than doubled compared to the general HMA. Furthermore, Overlay Test showed a tensile load residual rate of 4 times or more, improving crack resistance to repeated fatigue. Accordingly, the use of slag aggregate will likely have various advantages in improving the performance of asphalt concrete pavement.

Effect of modifying the thickness of the plate at the level of the overlap length in the presence of bonding defects on the strength of an adhesive joint

  • Attout Boualem;Sidi Mohamed Medjdoub;Madani Kouider;Kaddouri Nadia;Elajrami Mohamed;Belhouari Mohamed;Amin Houari;Salah Amroune;R.D.S.G. Campilho
    • Advances in aircraft and spacecraft science
    • /
    • v.11 no.1
    • /
    • pp.83-103
    • /
    • 2024
  • Adhesive bonding is currently widely used in many industrial fields, particularly in the aeronautics sector. Despite its advantages over mechanical joints such as riveting and welding, adhesive bonding is mostly used for secondary structures due to its low peel strength; especially if it is simultaneously exposed to temperature and humidity; and often presence of bonding defects. In fact, during joint preparation, several types of defects can be introduced into the adhesive layer such as air bubbles, cavities, or cracks, which induce stress concentrations potentially leading to premature failure. Indeed, the presence of defects in the adhesive joint has a significant effect on adhesive stresses, which emphasizes the need for a good surface treatment. The research in this field is aimed at minimizing the stresses in the adhesive joint at its free edges by geometric modifications of the ovelapping part and/or by changing the nature of the substrates. In this study, the finite element method is used to describe the mechanical behavior of bonded joints. Thus, a three-dimensional model is made to analyze the effect of defects in the adhesive joint at areas of high stress concentrations. The analysis consists of estimating the different stresses in an adhesive joint between two 2024-T3 aluminum plates. Two types of single lap joints(SLJ) were analyzed: a standard SLJ and another modified by removing 0.2 mm of material from the thickness of one plate along the overlap length, taking into account several factors such as the applied load, shape, size and position of the defect. The obtained results clearly show that the presence of a bonding defect significantly affects stresses in the adhesive joint, which become important if the joint is subjected to a higher applied load. On the other hand, the geometric modification made to the plate considerably reduces the various stresses in the adhesive joint even in the presence of a bonding defect.

Early Changes after Death of Plaice, Paralichthys olivaceus Muscle -5. Effect of Storage Temperature on Morphological Changes of Myofibrils and Histological Changes of Muscle- (넙치(Paralichthys olivaceus)육의 사후 조기 변화 -5. 저장 온도가 근원섬유의 형태학적 및 육의 조직학적인 변화에 미치는 영향-)

  • CHO Young-Je;LEE Keun-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.2
    • /
    • pp.114-120
    • /
    • 1994
  • To clarify the effect of storage temperature on the morphological and histological changes of plaice, Paralichthys olivaceus muscle at early stages after killing, the changes in breaking strength of muscle, morphological observation of myofibrils and histological observation of extracellular spaces during storage at $0^{\circ}C\;and\;10^{\circ}C$ were studied. The maximum breaking strength of samples stored at $0^{\circ}C$ was reached within 10hrs and then it dropped significantly (p<0.05) from 10hrs to 25hrs of storage. However, breaking strength was not increased in fresh muscle stored at $10^{\circ}C$ and gradually decreased after 10hrs storage. In myofibrils prepared from dorsal muscle immediately after death, A-band, I-band, H-band and Z-line in sarcomere were clearly distinguishable from each other. Due to muscle contraction, it was not easy to distinguish H-band from I-band observed in sarcomere stored at $0^{\circ}C$ after 10hrs storage. But, in the case of samples stored at $10^{\circ}C$, H-band could be observed dimly until 15hrs of storage. The changes in morphological myofibrils were closely related to increase of breaking strength. No extracellular space was observed among muscle cells immediately after killing. Stored samples at $0^{\circ}C$ showed extracellular spaces after 15hrs storage. On the other hand, samples stored at $10^{\circ}C$ didn't show any extracellular spaces until 15hrs storage and showed extracellular spaces after 24hrs storage. It was thought that the post-mortem tenderization of plaice muscle was closely related to the gradually disintegration of the extracellular matrix structure after killing.

  • PDF

A Study on the Establishment and Operation of a Regulatory Response Framework in connection with the Regulatory Strength of the Licensing Policy for New Medical Devices -Focusing on the Application of FMEA- (의료기기 신제품의 인허가정책 규제강도에 연계한 규제대응 프레임워크 수립 및 운영에 관한 연구 - FMEA 적용을 중심으로 -)

  • Kim, Gyosu;Ru, Gyuha;Kim, Yeonhee
    • Journal of Technology Innovation
    • /
    • v.28 no.4
    • /
    • pp.1-26
    • /
    • 2020
  • Due to the spread of Corona 19 around the world, Infectious Disease Medicine and New Medical Devices such as Diagnostic Agent are being rapidly developed and launched, and for the fast supply and demand of these, each country has eased import regulations or has implemented policies for fast approval(NIDS, 2020). On the other hand, New Developed Medical Devices that are not related to New Infectious Diseases, they are still entering the market through strict licensing and licensing regulations, such as delay and cancellation in the test inspection process, etc. Therefore, This Study specialized in the government-managed laws encountered when New Medical Devices enter the market, derive Factors influencing the Strength of Regulations, analyzes the Strength of Regulations, and proposes a Regulatory Response Framework. The Research Method was conducted by Literature Research, was applied by Failure Mode and Effects Analysis(FMEA) Method, Expert Interview(1st): Idea Collection, Expert Interview(2nd): Validation, and Priority through the Application Process of FMEA Method. A Method of Quantifying the Intensity of Regulation was proposed by multiplying the Impact of the Influencing Factors for each stage of regulation and the Burden Impact for each type of Regulatory Affairs to find the Importance of the Regulatory Factors and multiplying the Severity of the Regulatory Impact. The Implications are that major overseas countries and the Korean government are actively responding with Special Regulatory Policies and Mitigation Policies for fast licensing of New Developed Medical Devices in accordance with Corona 19. It is expected that the direction for improvement of regulations and measures to respond to regulations will be implemented so that a more proactive and preemptive response to the regulatory process of the licensing policy for New Devices can be achieved.