• Title/Summary/Keyword: hand circumference

Search Result 111, Processing Time 0.027 seconds

The Analysis of Relationship between Abdominal Adipose Tissue Distribution and Health Risk Factors in Adolescent Obese Man (청소년기 비만 남성의 복부지방조직 분포와 건강관련 위험지표의 관련성 분석)

  • Cho, Chang-Mo
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.239-245
    • /
    • 2017
  • In the current study, the relationships between abdominal adipose tissue depots and skinfold thickness, body circumference and composition, and blood lipids and pressure were investigated in adolescent obese man. Total abdominal adipose tissue (TAT) and subcutaneous adipose tissue (SAT) were correlated with skinfold thickness. Especially subscapular skinfold was highly correlated with TAT and SAT, and it was found that chest skinfold was the only predictor for estimating visceral adipose tissue (VAT). Body circumference and body composition were associated with TAT and SAT, not VAT, and correlation coefficient of waist circumference was highest. On the other hand, body fat mass was highly correlated with TAT and SAT than %body fat and fat free mass. It was also shown that blood triglyceride concentration and systolic blood pressure were the only predictor for estimating VAT and SAT respectively.

Effects of Seogeum Therapy on Obesity for Middle Aged Abdominal Obese Women (서금요법이 복부비만 중년여성의 비만정도에 미치는 효과)

  • Chae, Eun-Joo;Kim, Chun-Gill
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.3
    • /
    • pp.418-430
    • /
    • 2008
  • Purpose: This study was to examine the effects of Seogeum therapy for middle-aged abdominal obese women. Methods: Seogeum therapy combined cupping, stepping on ion aluminum board, adhering to Seoam moxibustion and Seoam pellet. The subjects consisted of 30 middle-aged abdominal obese women between 40 and 59 years of age: fifteen were assigned to experimental group, fifteen to control group. The data collection and treatments were performed from June to October, 2007. The subjects of experimental group participated in Seogeum therapy for 5 times per week during 8 weeks. The data were analyzed with Chi-square test, Wilcoxon signed rank test and Wilcoxon rank-sum test with SPSS/Window 12.0 program. Results: Seogeum therapy experimental group showed significant difference in change of general obesity indexes(body weight, body fat amount, body fat ratio, BMI) than control group supporting hypothesis 1. Experimental group showed significant difference in change of abdominal obesity indexes(abdominal fat ratio, waist circumference, hip circumference) than control group supporting hypothesis 2. Conclusion: Obesity management of Seogeum therapy had a positive effect for middle-aged obese women. Therefore, it is concluded that the obesity management of Seogeum therapy can be applied as a nursing intervention to decrease the obesity for middle-aged women.

  • PDF

A Study on the adaptedness of brassiere underbust length (브래지어 총(總) 길이 적합성(適合性)에 관(關)한 연구(硏究)(II))

  • Park, You-Shin;Choi, Young-Soon
    • Journal of Fashion Business
    • /
    • v.10 no.1
    • /
    • pp.31-40
    • /
    • 2006
  • We studied relation between the clothing pressure applied by types of brassiere, postures, feeling of tightness. The main results were summerized as follows; 1. The research subjects of this study were 9 who rate of body fat was borderline and degree of fatness was normal. As a result of clothing pressure, the most prefered value was $36.86g/cm^2$ on sensor 2 in standing position and the next was $34.76g/cm^2$ on sitting position. Furthermore, The maximum value of sensor 2 was $59.08g/cm^2$ (in standing), $57.93g/cm^2$ (in sitting). On the other hand, The average clothing pressure of bra C type was $23.67g/cm^2$ 2. The study of feeling of tightness applied by bra type was high in order of C

A Study on the Appropriateness of the Current Sizing System of Infant Coveralls (시판 유아용 커버롤의 치수적합성에 관한 연구)

  • 도월희;최혜선;김은경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.2
    • /
    • pp.277-288
    • /
    • 2003
  • The purpose of this study was to provide information on how to improve the current sizing system of infant coveralls through analysis of the present system. In order to compile the information about dissatisfaction with the appropriateness of the fit of infant coveralls, a questionnaire was administered to mothers of 241 infants (aged under 36 months) living in Seoul, and analyzed using the SPSS WIN.10.0 program. Also, the manufacturers'basic body sizes were investigated. The results of this study were as follows : 1. The results of the comparison between the manufacturers'basic body sizes and the body measurement values obtained as the physical standard of the nation(1997) show that in terms of length and hip circumference, the manufacturers'body sizes were larger. On the other hand, in the waist circumference, the manufacturers'body sizes were smaller than the national average. 2. Research on the production sizing system of domestic and international brands, showed that the sizing interval of domestic brands were 6 months, whereas the international brands were 3 months f3r infants under 12 months. 3. Concerning fit, the areas causing most dissatisfaction were: the trunk length, sleeve length, inside leg length, and neck depth. The results showed that dissatisfaction with the suitability of the sizing of current infant coveralls according to the body part differed among the groups according to the month of age.

Manufacture of High Quality Musical Steel Drums in Trinidad and Tobago

  • Lewis Winston G.;Ameerali Aaron O.;Pun Kit-Fai
    • International Journal of Quality Innovation
    • /
    • v.6 no.3
    • /
    • pp.204-215
    • /
    • 2005
  • This paper explores innovative manufacturing processes, which can be used to manufacture the national musical instrument of Trinidad and Tobago, the Musical Steel Drum or Steel Pan. The main manufacturing process used today is the manual hand-forming technique. In order to achieve more consistent and deeper formed components while maintaining the high quality of the instrument, it is proposed that the Marforming process and the Flow-forming process, an adaptation of the Spinforming process, be used more frequently in the future to replace the traditional Hand-forming method. In the traditional Spinforming technique material is pushed from the outer circumference of the metal disc to the center in progressive passes of the former. This results in a thinning of the outer region of the formed component with thickening of the center, however the opposite is required for the musical steel drum and by adapting the process the required strain distributions were achieved. Evaluation took the form of strain analyses of pre-formed steel drums and visual inspection of the quality of the surface finish. It was found that the Marformed components had the smallest range of strain values while the Spinformed components had the largest range.

A Comparative Study of the Effect of Resisted Exercise Using Thera-bands according to Grip Type: Pain and Range of Motion of the Shoulder in a Patient with Lymphedema after Mastectomy (그립 유형에 따른 탄력밴드 저항운동 효과의 비교 연구 ; 유방절제술로 발생한 팔 림프부종 환자에 대한 통증 및 어깨관절가동범위에 대하여)

  • Jo, Yejin;Lee, Sangryul
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.47-56
    • /
    • 2020
  • Purpose : The purpose of this study was to determine the effects of upper extremity volume, pain, and range of motion after participation in thera-band exercises according to the hand grip type in patients with breast cancer with upper extremity edema. We also aimed to determine the most efficient type of grip. Methods : The subjects were 10 female patients diagnosed with stage 2 breast cancer who had stage 2 lymphedema. Randomly, 5 patients each were allocated to the experimental and control groups. For six weeks, the patients in both the experimental and control groups exercised daily. In both groups, manual lymph drainage was applied for 1 hour. Afterward, patients in the experimental group placed their hands in the thera-band ring and exercised with their fingers outstretched. Patients in the control group exercised while holding the thera-band ring with a finger. Both the experimental group and the control group underwent measurements of the circumference of the upper extremity, pain, and range of motion of the shoulder joint at weeks 1, 2, 4, and 6 before and after exercise. Results : The upper arm circumference decreased by more in the experimental group in all weeks than before than that in the control group, and there was a statistically significant difference at 6 weeks. Compared with the difference between pre-exercise and 6 weeks post-exercise, the change in pain significantly decreased in the experimental group and showed a statistically significant difference. The shoulder range of motion increased in extension, external rotation, and internal rotation compared with that in the control group, and there was a statistically significant difference. Although the operating range increased in flexion and abduction, there were no statistically significant differences. Conclusion : In this study, we found that thera-band exercises with an open-hand grip are more efficient than thera-band exercises with a closed-hand grip in edema reduction, pain, and range of motion. In addition, it was found that it was more effective to continue the thera-band exercises with open-hand grip extended for at least 6 weeks rather than for a short time.

Accuracy of Electronic Pedometers to Assess Body Fatness in Obese Children and Youth (비만 어린이와 청소년들의 체지방 평가를 위한 electronic pedometer 의 정확성 분석)

  • Kim, Do-Yeon
    • Journal of Life Science
    • /
    • v.19 no.10
    • /
    • pp.1368-1373
    • /
    • 2009
  • The purpose of this study was to assess the influence of waist size on the reliability and validity of pedometers to count steps in children and youth. The participants for this study were 20 children and youth, composed of 14 Hispanic and 6 Caucasian children. Ten children and youth had waist circumferences greater than the $85^{th}$ percentile (Body Mass Index (BMI)=$28.91\pm3.07$), and 10 children and youth had waist circumferences smaller than the $50^{th}$ percentile (BMI=$18.05\pm1.55$). To examine pedometer reliability, each child completed 3 ascent and descent trials up a set of 15 stairs while wearing a Yamax SW-701 pedometer. The main effect of trials was not statistically significant for the stair ascent trials F (2, 36)=2.575 or for the descent trials F (2, 36)=0.235. The trial by group interaction was also not statistically significant. To examine the influence of waist circumference on the validity of the pedometer in counting walking steps at a self-selected walking pace, the children and youth in the two groups completed a 400-m course. The main effect on the groups was statistically significant, F (1, 18)=7.489. The main effect of counting techniques was not statistically significant, F (1, 18)=2.983 (hand-counted vs. pedometer counted). Overall, the trial and trial by group interaction comparisons for the 400-m walk were not statistically significant, suggesting that the pedometer was equally valid as a tool for assessing walking steps in high waist circumference (HWC) and low waist circumference (LWC) in children and youth.

The Change of The Effect on The Subcutaneous Fat Area and Visceral Fat Area by The Functional Electrical Stimulation and Aerobic Exercise (기능적 전기 자극과 유산소 운동이 복부비만의 피하지방과 내장지방에 미치는 효과)

  • Oh Sung-tae;Lee Mun-hwan;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.85-123
    • /
    • 2004
  • Back ground : Subcutaneous fat area is the main factor involved in replacement disease and arteriosclerosis. Simple weight control is the appropriate medical treatment. It's understood that weight reduction does not only reduce the fat concentrations in blood but also reduces blood pressure, improves glucose levels in diabetes patients and reduces incidents of heart disease. there are several methods for reducing fat in the abdominal region but their effectiveness is not folly understood. one method is electrical stimulation of the problem areas. Method : From May 1st 2002 to October 31st. The 15 subjects who received medical examination were aged between 25 and 53 and were of mixed gender. The subjects were divided into two groups one to received functional electrical stimulation and the other a control group. Using Broca's criterion for judging fat grades. I analysed the differences between the two groups before and after the treatment. Subjects received functional electrical stimulation on the abdominal muscle intensity 50Hz. They received this treatment 4 days a week for 40 minutes a day. In the case of aerobic exercise, at the Treadmill, we used it with the intensity of $75\%$ maximum heart rate (220-age). Result 1)After functional electrical stimulation in the case of male subjects, the weight was reduced 1.93kg, obesity $2.60\%$, fat mass 2.73kg, Percent body fat $4.40\%$, waist circumference 6.53cm, circumference of hips 5.53cm. On the other side, the quality of muscle was increased at the rate of 1.03kg, but it's not attentional level. The subcutaneous fat area was reduced by $26.63cm^2$, the visceral fat area was reduced by $43.00cm^2$, In the female subjects, we can see the reduction of fat grade by $26.63cm^2$, the quantity of body fat by 1.5kg, percent body fat by $1.77\%$, circumference of waist by 4.02cm, circumference of hips by 3.67cm, weight by 1.40kg but was increased 0.72kg at the quantity of muscles. We can see the reduction also in the subcutaneous fat area $24.03cm^2$, the visceral fat area by $25.36cm^2$. 2)After aerobic exercise, on the male subjects, we can see reduction of weight by 3.36kg, obesity by $4.00\%$, fat mass by 2.83kg and we can see increase at the soft lean mass by 2.96kg, but we can see reduction, the percent body fat by $3.03\%$, fat distribution by $0.023\%$, circumference of waist by 3.10cm, circumference of hips by 2.23cm. The female subjects show a reduction in the weight by 2.48kg, percent body fat by $2.20\%$, show an increase in the soft lean mass by 1.54kg. We can see a reduction in the quantity of fat mass by 2.32kg, the percent body fat by $2.80\%$, the circumference of waist by 2.16cm, the circumference of hips by 2.68cm, the fat distribution by $0.016\%$, the subcutaneous fat area by $15.25cm^2$ the visceral fat area by $11.52cm^2$. After aerobic exercise, we can't see the attentional change at the total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. 3)After the application of functional electrical stimulation and aerobic exercise, in result of measurement on the body ingredient, we could see the weight reduction and increase the quantity of muscle with the male group who exercised aerobic. We can see the attentional rate on the electrical stimulation about abdominal fat rate, circumference of waist, circumference of hips. The other hand, I couldn't see the attentional differences between the two groups in the rate of fatness and quantity of body fat and the rate of body fat. There isn't any attentional difference in the area of fat under skin, on the contrary, There is attentional difference in the fat in the internal organs area at the electrical stimulation site. We can't see the attentional change of total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol between electrical stimulation and aerobic exercise. 4)After execution of functional electrical stimulation and aerobic exercise, in result of measurement on change of body ingredient among female objects, We could see weight reduction, increase at muscle quantity in the aerobic exercise group. We could see the attentional differences in the rate of fatness, the rate of abdominal region, the circumference which received electrical stimulation. But, we couldn't see the attentional differences between two groups in the quantity of body fatness, the circumference of hips. The subcutaneous fat area doesn't show the attentional differences. On the Contrary, we could see lots of differences in the visceral fat area of the electrical stimulation group. Conclusion The results show that functional electrical stimulation and aerobic exercise have insignificant differences when if comes to total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. Though there is affirmative change in body ingredient after both electrical stimulation and aerobic exercise. Functional electrical stimulation is more effective on the subcutaneous fat area and in changing visceral fat area. There fore. It is concluded that the physical therapy is more effective in the treatment of abdominal fatness.

  • PDF

A Study on Establishment of Glove Size System and Hand Shape (손 형태의 특징 및 장갑의 치수 설정에 관한 연구)

  • Kwon Myoungsook;Choi Insoon;Chung Gisoo;Yang Minjae
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.6 s.96
    • /
    • pp.24-37
    • /
    • 2005
  • This study was performed to get basic data for gloves size system and pattern planning suitable Korean hand shape. Data was collected through measuring hand size of man and woman from age 18 to 30 as subjects living in metropolitan area. by analysing the measured data, the difference in man and woman and the gloves size system was established. The results of study are as follows: 1. The Deviation of hand girths and hand lengths was larger than that of hand width in both man group and woman group. In all items. deviation in man was larger than woman. 2. In sex difference, there was difference between mall group and woman group in all items. In age difference, there was difference between mall group and woman group in mainly girth and the difference was bigger in group under 24 years old than in group over 24 years old. 3. The weight showed the highest $correlation(r{\geqq}0.8)$ with girths and high correlation with widths $(r{\geqq}0.7).$ The height showed the highest positive $correlation(r{\geqq}0.8)$ with and elbow length and high correlations with width and girths item. There were high positive correlation between vertical lengths in hand and between horizontal lengths but low correlation between vertical lengths and horizontal lengths. 4. The basic parts for gloves size system, hand lengths and hand girths were divided into 1cm interval. The results shouted that $91.0\%$ of man group were ranged from 18cm to 20cm section and $92.4\%$, of woman group were ranged from 16cm to 18cm section. 5. The interval which has the highest covet· rate was hand length 19cm and hand girth 20cm interval which covered $18.65\%$ of man group. The intervals which showed cover rate more than $5\%$ was total 7 and they covered $73.1\%$ of man group. The interval which has which has the highest cover rate was hand length 17cm and hand girth 17cm interval which covered $21.37\%$ of woman group. The intervals which showed cover rate more than $5\%$ was total 6 and they covered $72.5\%$ of total woman group.

Correlation of Forearm Circumference; With Hand Grip Strength (전완 원주와 악력과의 상관관계)

  • Cynn, Heon-Seock
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.1047-1050
    • /
    • 2001
  • 이 연구의 목적은 전완 원주와 악력과의 상관관계를 알아보는 것이다. 오른손잡이 여성 30명이 이 연구에 참여하였으며, 연구의 대상자의 평균 연령은 31.0세였다. 전완 원주는 척골의 주두와 경상돌기의 1/2 지점과 근위 3/4 지점에서 줄자를 이용하여 측정하였다. 악력은 미국 수부 치료사 협회의 기준에 의하여 Jarmar dynamometer를 사용하여 측정하였다. 통계학적 분석은 피어슨 상관 관계 계수를 이용하여 상관관계를 조사하였다. 전완 두 지점에서 측정된 원주와 악력간에는 낮은 상관관계를 나타내었다(r=.02. p=.921; r=.02, p=.928). 연구 대상자 30명 중 정기적으로 상체 운동을 하는 18명의 연구 대상자들의 전완 두 지점에서도 낮은 상관 관계를 나타내었다(r=.16, p=.521: r=.18, p=.468). 본 연구의 결과는 선행된 다른 연구 결과와는 상이하게 높은 상관관계를 나타내지 않았다. 그 이유로는 본 연구에서 악력에 영향을 주는 여러 가지 요소들(신체 유형, 운동 습관. 직업 피하 지방성분, 유전적 요소 등)의 측정이 고려되지 않았고. 연구 대상자의 수(n=30)가 적었다는 점을 들 수 있다.

  • PDF