• 제목/요약/키워드: half-dose

검색결과 536건 처리시간 0.02초

수면과 알코올 (Alcohol and Sleep)

  • 박두흠;유재학;유승호
    • 수면정신생리
    • /
    • 제13권1호
    • /
    • pp.5-10
    • /
    • 2006
  • Alcohol has extensive effects on sleep and daytime sleepiness. Alcohol has a sleep inducing effect and the effect of increased non-REM sleep and suppressed REM sleep during the first half portion of night sleep, but alcohol induces the effect of decreased non-REM sleep and increased light sleep and frequent awakenings and REM rebound during the second half portion of night sleep. Alcohol provokes chronobiological change such as the changes of amplitude or the phase shifts of hormones or core body temperature. The sleep disruption resulting from alcohol drinking may lead to daytime fatigue and sleepiness. The elderly are at particular in the increased risk of alcohol-related sleep disorders because they achieve higher levels of alcohol in the blood and brain than do younger adults after consuming an equivalent dose. Bedtime alcohol consumption among older adults may lead to unsteadiness if walking is attempted during the night, with increased risk of falls and injuries. Continued alcohol use for sleep induction often induces aggravation of insomnia, alcoholism or sleep related breathing disorders such as obstructive sleep apnea. Alcohol should not be used as substitution of sleep pill because of the dependence and tolerance for sleep inducing effect, and the sleep disruption produced by alcohol withdrawal.

  • PDF

U-937 세포에 있어서 세라마이드에 의한 c-jun 유전자 발현의 조절 (Ceramide-Mediated c-jun Gene Expression in U-937 Cells)

  • 김원호;김미영;최경희
    • 약학회지
    • /
    • 제41권1호
    • /
    • pp.81-85
    • /
    • 1997
  • Ceramide has been suggested as an important mediator of the effects of extracellular agonists on cell growth inhibition, differentiation, apoptosis. However the biochemical sign aling mechanism involved in transducing the effects of ceramide on leukemia cell differentiation is still unclear. In these respects, we examined the regulatory effects of ceramide on c-jun gene expression during differentiation. In U-937 cells. ceramide increased c-jun mRNA levels in a time-dependent manner. The half life, of c-jun mRNA was 30 min. In contrast, inhibition of protein synthesis with cycloheximide in the absence, of transcription with actinomycin D increased the half-life of c-jun mRNA in ceramide-treated U-937 cells to more than 90 min. In order to examine whether ceramide-inhibited c-jun gene expression is regulated through ceramide-activated protein phosphatase (CAPP), a direct target for the action of ceramide, okadaic acid were treated to the cells. Okadaic acid inhibited enhancement of c-jun mRNA induced by C2-ceramide in a dose-dependent manner. These results suggested that ceramide increases c-jun mRNA level during differentiation in U-937 cells and regulates the gene expression on posttranscriptional level. In addition, we provide the evidence that CAPP is involved in ceramide-induced c-jun gene expression in U-937 cells.

  • PDF

Bag-Valve-Mask의 사용방법에 따른 일회호흡량과 평균기도압의 변화 연구 (Differentiation of tidal volume & mean airway pressure with different Bag-Valve-Mask compression depth and compression rate)

  • 조승묵;정형근
    • 한국응급구조학회지
    • /
    • 제16권2호
    • /
    • pp.67-74
    • /
    • 2012
  • Purpose : The purpose of this study is to get basal user guidelines of safer bag-valve-mask application on patient with normal pulmonary patho-physiologic condition. Methods : This study was accomplished by pre-qualified 25 EMS junior grade students. Participants were instructed randomly compress bag to one-third, half and total and also with differesnt compression speed. Resultant tidal volumes and mean airway pressures obtained in RespiTrainer were analysed in relation to the each compression depth and rate. Results : Demographic difference does not affect tidal volume with any compression depth and rate change. Increasing compression depth is correlated with tidal volume increasement at any compression rate and also with mean airway pressure. If the compression depth is same, compression rate change did not affect significantly the resultant tidal volume or mean airway pressure. Conclusion : Hand size, Experience, BMI dose not affect tidal volume. Compress the 1600 ml bag half to total amount is safe way to offer sufficient tidal volume without risky high airway pressure delivery to patient airway who with normal lung patho-physiologic condition.

A preliminary study on real-time Rn/Tn discriminative detection using air-flow delay in two ion chambers in series

  • Sopan Das ;Junhyeok Kim ;Jaehyun Park ;Hojong Chang;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4644-4651
    • /
    • 2022
  • Due to its short half-life, thoron gas has been assumed to have negligible health hazards on humans compared to radon. But, one of the decay products with a long half-life can make it to be transported to a long distance and to cause a severe internal dose through respiration. Since most commercial radon detectors can not discriminate thoron signals from radon signals, it is very common to overestimate radon doses which in turn result in biased estimation of lung cancer risk in epidemiological studies. Though some methods had been suggested to measure thoron and radon separately, they could not be used for real-time measurement because of CR-39 or LR-115. In this study, an effective method was suggested to measure radon and thoron separately from the free air. It was observed that the activity of thoron decreases exponentially due to delay time caused by a long pipe between two chambers. Therefore from two ion chambers apart in time, it was demonstrated that thoron and radon could be measured separately and simultaneously. We also developed a collimated alpha source and with this source and an SBD, we could convert the ion chamber reading to count rate in cps.

폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가 (The Evaluation of Hybrid-Volumetric Modulated Arc Therapy for Lung Cancer Radiation Therapy)

  • 이건호;강효석;최병준;박상준;정다이;이두상;안민우;전명수
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.19-26
    • /
    • 2017
  • 목 적: 폐에서 VMAT치료는 연속적으로 회전을 하면서 방사선을 조사하므로 정상적인 폐에 저 선량을 증가시킨다. 이로 인해 방사선 부작용 중 방사선 폐렴의 발생률이 증가 할 수 있다. 본 연구에서는 방사선 폐렴의 발생 확률 증가 원인이 되는 폐의 저 선량 영역의 방사선을 줄일 수 있는 H-VMAT 방법을 적용하여 치료를 받은 환자를 대상으로 치료계획별 폐의 저 선량 영역과 주변 정상장기들에 전달되는 방사선량을 비교 분석하여 H-VMAT의 유용성을 평가하고자 하였다. 대상 및 방법: 폐암방사선 치료 환자 중 H-VMAT 방법을 적용한 환자 25명을 대상으로 하였으며, 치료 계획용 용적의 처방선량은 총 선량 44 Gy를 22회 분할 조사로 적용하였다. 각 환자마다 Conventional RT, VMAT, H-VMAT 방법으로 계획을 진행하였다. Conventional RT는 치료계획용적의 크기, 위치, 모양 및 주변장기들의 위치를 고려하여 4~5개 조사야로 치료계획을 진행하였고, VMAT 치료계획의 경우는 $360^{\circ}$를 2번 회전하는 방법과 $180^{\circ}$를 2~3회 회전하는 방법으로 계획하였다. H-VMAT은 폐의 선량 및 주변 장기의 허용선량을 고려하여 VMAT 치료계획에서 2개의 고정조사야를 추가 하여 계획하였다. 결 과: 폐선량은 비소세포성폐암에서 치료계획용적을 제외한 폐의 $V_5$, $V_{10}$은 H-VMAT이 $55.40{\pm}13.39%$, $32.05{\pm}11.37%$로 가장 낮았고, 소세포성폐암에서도 $V_5$, $V_{10}$의 값은 $64.32{\pm}16.15%$, $35.50{\pm}9.91%$로 가장 낮았다. 비소세포성폐암에서 VMAT의 척수 선량은 $21.15{\pm}4.02Gy$로 다른 치료방법과 비교하여 최대 7.94 Gy 차이만큼 낮은 선량이 전달되었고, 소세포성폐암에서는 $19.72{\pm}1.82Gy$로 가장 낮은 선량을 보였다. 심장의 $V_{20}$은 H-VMAT와 VMAT의 비교 결과 VMAT이 최대 16.2 % 더 낮은 값을 보이기도 하였다. 식도에 전달되는 평균선량 역시 소세포성폐암과 비소세포성폐암에서 $17.44{\pm}2.04Gy$, $17.84{\pm}9.20Gy$로 VMAT이 가장 낮았다. 결 론: 주변 정상 장기 선량의 값을 비교해 보았을 때, VMAT에서는 심장, 식도, 척수 등에서 나머지 치료계획보다 더 적은 선량이 전달되는 것을 알 수 있었다. 하지만 척수를 제외한 나머지 장기에서는 H-VMAT과 큰 차이를 보이지 않았다. H-VMAT은 일부 정상 장기의 선량이 증가하였지만 허용선량을 초과하지 않았다. 그리고 폐의 $V_5$, $V_{10}$에서 낮은 값을 보였다. Conventional RT, VMAT, H-VMAT을 비교하였을 때 심장, 식도, 척수 등에 전달되는 선량이 부작용을 발생시킬 수 있는 선량보다 적다면 폐의 저 선량 영역의 장점을 보이는 H-VMAT 방법을 적용함으로써 방사선폐렴의 발생률을 낮출 수 있을 것이라고 사료된다.

  • PDF

Evaluation of Cumulative and Conditional Antibiotic Release from Vancomycin-Embedded Fibrin Sealant and Its Antibacterial Activity : An In Vitro Study

  • Shin, Dong-Won;Sohn, Moon-Jun;Cho, Chong-Rae;Koo, Hae-won;Yoon, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권1호
    • /
    • pp.45-55
    • /
    • 2020
  • Objective : Fibrin sealants have been used for hemostasis, sealant for cerebrospinal fluid leakage, and adhesive barrier in neurosurgery. Further, as its clinical use and role of an effective drug delivery vehicle have been proposed. This study was performed to measure antibacterial activity and continuous local antibiotic release from different concentrations of vancomycin-impregnated fibrin sealant in vitro. Methods : Antibacterial activity was investigated by disk diffusion test by measuring the diameter of the growth inhibition zone of bacteria (methicillin-resistant Staphylococcus aureus, ATCC29213) from vancomycin-embedded fibrin sealant disc diluted at five different concentrations (C1-C5; 8.33, 4.167, 0.83, 0.083, and 0.0083 mg/disc, respectively). Continuous and conditioned release of vancomycin concentration (for 2 weeks and for 5 days, respectively) were also measured using high-performance liquid chromatography (HPLC) method. To mimic the physiologic wound conditions with in vitro, conditioned vancomycin release in phosphate buffer solution (PBS) was measured and replaced PBS for five consecutive days, half a day or completely daily. Results : In the disk diffusion test, the mean diameters of bacterial inhibition zone were 2.54±0.07 cm, 2.61±0.12 cm, and 2.13±0.15 cm (C1, C2, and C3 respectively) but 1.67±0.06 cm and 1.23±0.15 cm in C4 and C5, respectively. Continuous elution test elicited the peak release of vancomycin from the fibrin sealant at 48 hours, with continued release until 2 weeks. However, conditioned vancomycin release decreased to half or more on day 2, however, the sustainable release was measured over the therapeutic dose (10-20 ㎍/mL) for 5 days and 4 days in assays of half and total exchange of PBS. Conclusion : This study suggests that fibrin sealant can provide an efficient vehicle for antibiotic drug release in a wide range of neurosurgical procedures and the safe and effective therapeutic dose will be at the concentration embedded of 4.167 mg/disc or more of vancomycin.

Off-line PET-CT를 이용한 양성자치료에서의 Range 검증 (Analysis of the Range Verification of Proton using PET-CT)

  • 장준영;홍건철;박세준;박용철;최병기
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.101-108
    • /
    • 2017
  • 목 적: 양성자치료에 이용되는 양성자선은 종양 부위 앞에 있는 정상 조직에는 적은 선량을 주는 반면 암 조직 부위에서는 브래그 피크(Bragg peak)를 형성하며 최대 선량을 주고 바로 소멸하는 특징을 가지고 있으며 양성자치료의 장점을 극대화하기 위해서는 양성자의 도달 위치 검증이 매우 중요하다. 본 연구에서는 Off-line PET CT 방법을 이용하여 양성자 조사 후 양성자 궤적을 따라 생성된 11 C(반감기=20분), 150(반감기=2분), 13N (반감기=10분) 등의 핵자에서 방출되는 양전자의 분포를 측정하여 양성자의 Range와 Distal falloff 지점을 검증하게 되었다. 대상 및 방법: IEC 2001 Body 팬텀안에는 37 mm, 28 mm, 22 mm 구체를 삽입할 수 있게 구성되어 있으며 팬텀안에 물을 가득 채워 각 구체크기별로 CT image를 획득하였고 양성자의 Range와 Distal falloff 지점을 검증하기 위하여 양성자치료계획시스템으로 각 구체 크기 별로 37 mm 구체에서 46 mm, 28 mm에서 37 mm, 22 mm 구체에서 33 mm의 SOBP를 설정하였고, Scanning 방법으로 Gantry 0도의 Single beam으로 동일한 센터에서 양성자를 조사하였다. 조사된 팬텀은 PET-CT 장비를 이용하여 스캔하였고, PET-CT 영상획득방법은 1분씩 50개의 영상을 획득하여 팬톰 내의 구체를 포함하여 4개의 ROI를 설정한 후 10개씩 영상을 합산하여 재구성 하였다. 치료계획 시 수립한 구체크기에 따른 Dose profile과 비교하기 위하여 Depth에 따른 Activity profile로 나타냈다 결 과: 37 mm, 28 mm, 22 mm 구체에서 모두 Distal falloff position 에서 Dose profile과 같이 PET-CT의 Activity profile 역시 급격히 감소하는 양상을 나타냈다. 하지만 Range를 평가하는 구간인 SOBP구간에서는 Activity profile의 경우 Proximal 부분에서의 측정치가 Dose profile 양상과 다른 결과가 나왔으며, Distal falloff position을 구체 크기별로 양성자 치료계획과 PET-CT 측정치와의 차이를 비교해 본 결과 37 mm 구체에서는 Max dose의 50 % 지점에서 최대 1.4 mm, 28 mm 구체에서는 45 % 지점에서 최대 1.1 mm, 22 mm 구체에서의 차이는 40 % 지점에서 최대 1.2 mm로 모두 1.5 mm 미만의 차이를 보였다. 결 론: 양성자치료의 장점을 최대한 활용하기 위해서는 양성자빔의 Range를 검증하는 것이 매우 중요하다. 본 연구에서는 PET-CT 장비를 이용하여 양성자빔의 SOBP 와 Distal falloff 위치를 통해 양성자 Range를 확인하였고 그 결과 PET-CT 장비를 이용해 측정한 Activity 분포와 양성자 치료계획과의 Distal falloff position의 차이는 1.4 mm 내에서 일치함을 확인하였다. 이는 본원에서 양성자치료계획 시 적용하는 선량마진에 참고자료로 활용될 수 있을 것으로 사료된다.

  • PDF

Phase II Study on Breast Conservative Surgery Plus Chemo- and Radiotherapy in Treating Chinese Patients with Early Staged Breast Cancer

  • Liu, Yang-Chen;Zhou, Shao-Bing;Gao, Fei;Yin, Xiao-Xiang;Zhao, Ying;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권6호
    • /
    • pp.3747-3750
    • /
    • 2013
  • Purpose: To evaluate the efficacy of conservative surgery plus chemo-, radio-therapy in treating patients with early stage breast cancer. Patients and Methods: Eligible patients were treated by postoperative chemotherapy as well as whole-breast irradiation with tumor bed boost. Postoperative radiotherapy consisted of 6 MV whole breast linear accelerator irradiation with two tangential half fields to a total dose of 45~50 Gy, followed by $10{\sim}15MeV{\beta}$ boost irradiation to tumor bed for 10~20Gy, total dose 56~66Gy. Results: Fifty-two patients were enrolled. Overall 1-, 2- and 3 year survival rates were 98.1%, 92.3%, and 90.4%, respectively, with a local recurrence rate of 5.77%. Cosmetic results were evaluated as good by doctors in 90.4% of patients. Conclusions: Breast conservative surgery combined with chemo- radio-therapy could be a treatment option for Chinese patients with early stage breast cancer.

Intracavitary Ultrasound Hyperthermia Applicators for Gynecological Cancer

  • Lee, Rena J. .;Suh, Hyun-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.53-53
    • /
    • 2003
  • For evaluating the feasibility of treating recurrent lesions in the vaginal cuff and cervix by hyperthermia, ultrasound applicators were designed, constructed, and characterized. For the treatment A half-cylindrical transducer Cd=1cm, length=lcm) and cylindrical transducer (d=2.5cm, length= 1.5cm) were used to construct ovoid type and cylindrical applicators. For the ovoid type applicator, each element was operated at 1.5MHz and characterized by measuring transducer efficiency and acoustic power distribution. Thermocouple probes were used to measure the temperature rise in phantom. The element sizes used in this study were selected to be comparable for high dose rate brachytherapy colpostat applicator. Each element was powered separately to achieve a desired temperature pattern in a target. The acoustic output power as a function of applied electric power of the element 1 and 2 was linear over this 1 to 40 W range and efficiencies were 32.2${\pm}$3.4% and 46.2${\pm}$0.8%, respectively. The temperature measurements in phantom showed that 6$^{\circ}C$ temperature rise was achieved at 2 cm from the applicator surface. As a conclusion, the ability of the ultrasound colpostat applicator to be used for hyperthermia was demonstrated by measuring acoustic output power, ultrasound field distribution, and temperature rise in phantom. Based on the characteristics of this applicator, it has the potential to be useful for inducing hyperthermnia to the vaginal cuff in clinic.

  • PDF

Simplified HPLC Method for the Determination of Prazosin in Human Plasma and Its Application to Single-dose Pharmacokinetics

  • Gwak, Hye-Sun;Chun, In-Koo
    • Biomolecules & Therapeutics
    • /
    • 제13권2호
    • /
    • pp.90-94
    • /
    • 2005
  • Prazosin hydrochloride is an antihypertensive drug with selective ${\alpha}_1$-adrenoreceptor blocking effects. A simple high performance liquid chromatographic method has been developed and validated for the quantitative determination of prazosin in human plasma. A reversed-phase C18 column was used for the separation of prazosin and terazosin (internal standard) with a mobile phase composed of water, acetonitrile and triethylamine(75:25:0.1, V/V;pH5.0) at a flow rate of 1.5 ml/min. the fluorescence detector was set at excitation and emissionwavelengths of 250 and 370 nm, respectively. Intra-and inter-day precision and accuracy were acceptable for all quality control samples including the lower limit of quantification of 0.5 ng/ml. Good recovery (>80%) was seen in plasma. Prazosin was stable in human plasma under various storage conditions. This method was used successfully for a pharmacokinetic study in plasma after oral administration of a single 2-mg dose as prazosin base to 16 healthy volunteers. The maximum plasma concentration of prazosin was 23.1 ${\pm}$ 16.5 ng/ml at 2.1 h, and the mean area under the curve and elimination half-life were calculated to be 108.4 ${\pm}$ 74.2 ng ${\cdot}$hr/ml and 2.5 ${\pm}$ 0.6 h, respectively.