• 제목/요약/키워드: half value layer

검색결과 138건 처리시간 0.024초

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

Calculation of X-ray spectra characteristics and kerma to personal dose equivalent Hp(10) conversion coefficients: Experimental approach and Monte Carlo modeling

  • Arectout, A.;Zidouh, I.;Sadeq, Y.;Azougagh, M.;Maroufi, B.;Chakir, E.;Boukhal, H.
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.301-309
    • /
    • 2022
  • This work aims to establish some X-ray qualities recommended by the International Standard Organization (ISO) using the half-value layer (HVL) and Hp(10) dosimetry approaches. The HVL values of the following qualities N-60, N-80, N-100, N-150 and N-250 were determined using various attenuation layers. The obtained results were compared to those of reference X-ray beam qualities and a good agreement was found (difference less than 5% for all qualities). The GAMOS (Geant4-based Architecture for Medicine-Oriented Simulations) radiation transport Monte Carlo toolkit was employed to simulate the production of X-ray spectra. The characteristics HVLs, mean energy and the spectral resolution of simulated spectra have been calculated and turned out to be conform to the ISO reference ones (difference less than the limit allowed by ISO). Furthermore, the conversion coefficients from air kerma to personal dose equivalent for simulated and measured spectra were fairly similar (the maximum difference less than 4.2%).

Gamma ray exposure buildup factor and shielding features for some binary alloys using MCNP-5 simulation code

  • Rammah, Y.S.;Mahmoud, K.A.;Mohammed, Faras Q.;Sayyed, M.I.;Tashlykov, O.L.;El-Mallawany, R.
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2661-2668
    • /
    • 2021
  • Gamma radiation shielding features for three series of binary alloys identified as (Pb-Sn), (Pb-Zn), and (Zn-Sn) have been investigated. The mass attenuation coefficients (µ/ρ) for the selected alloys were simulated using the MCNP-5 code in the energy range between 0.01 and 15 MeV. Moreover, the (µ/ρ) values were computed using WinXCOM database in the same energy range to validate the simulation results. Results reveal a good agreement between the simulated and computed values. The half value layer (HVL), mean free path (MFP), effective atomic number (Zeff) and exposure buildup factor (EBF) were evaluated for the selected binary alloys. Results showed that the PS1, PZ1, and ZS2 alloys have the best shielding parameters and better than the commercially standard and available radiation shielding materials. Therefore, the investigated alloys can be used as effective radiation shielding materials against gamma ray with energies between 0.01 and 15 MeV.

Implementation of waste silicate glass into composition of ordinary cement for radiation shielding applications

  • Eid, Mohanad S.;Bondouk, I.I.;Saleh, Hosam M.;Omar, Khaled M.;Sayyed, M.I.;El-Khatib, Ahmed M.;Elsafi, Mohamed
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1456-1463
    • /
    • 2022
  • The aim of this work is to study the radiation shielding properties of cement samples with waste glass incortated into its composition. The mass attenuation coefficient (MAC) of the samples were experimentally determined to evaluate their radiation shielding ability. The experimental coefficient was evaluated using NaI detector for gamma energies between 59.53 keV and 1408.01 keV using different radioactive point sources Am-241, Eu-152, Co-60, and Cs-137, and the gamma transmission parameters half-value layer, mean free path, and transmission factor were calculated. The theoretical coefficient of the composites was determined using Geant4 and XCOM software. The results were also compared against Geant4 and XCOM simulations by calculating the relative deviation between the values to determine the accuracy of the results. In addition the mechanical properties (including Compressive and porosity) as well as the thermogravimetric analysis were tested for the present samples. Overall, it was concluded that the cement sample with 50% waste glass has the greatest shielding potential for radiation shielding applications and is a useful way to reuse waste glass.

스트랜드/파티클 복합체의 기계적 성질에 관한 연구(I) - 단면구성이 기초물성에 미치는 영향 - (A Study on Mechanical Properties of Strand/Particle Composites(I) - Effect of Layer Constructions -)

  • 김유정;시부사와 타츠야
    • Journal of the Korean Wood Science and Technology
    • /
    • 제28권3호
    • /
    • pp.1-8
    • /
    • 2000
  • 본 연구는 미이용 자원인 소경목(小經木) 조생수(早生樹) 등의 저질원료로부터 고성능을 지니는 구조용 보드를 제조하는 기술을 개발하는 것을 목적으로 하여 할렬 스트랜드 (S)/파티클(P) 복합체의 층구조와 S와 P의 혼합비율을 바꾼 단면구성에 따른 기초적 물성을 검토했다. 그 결과 스트랜드층을 포함하고 있는 SP 복합체의 경우, 전체적으로 휨성능(MOR, MOE)이 매우 높았다. 또 S단층 보드는 현저한 이방성을 나타내었지만 층구조가 PB에 가까워질수록 이방성은 감소하여, 7층 구조의 복합체는 이방성이 적었으며 특히 SP7은 직교방향도 휨강도가 높았다. 습윤시 휨강도 성능도 같은 경향을 나타내었다. 박리강도(IB)는 PB가 가장 높았고, 스트랜드층을 가진 복합체는 거의 같은 값을 나타내었다. 두께팽창율(TS) 은 PB가 가장 적은 값을 나타내었으며, 표층이 P층인 구조가 S표층구조보다 적은 경향을 나타내었다. 복합체의 표면특성은 표층 엘리먼트의 영향을 받아, 적고 미세한 엘리먼트인 P표층의 복합체가 크고 두꺼운 S표층 복합체보다 양호하였다. S와 P의 혼합비율의 영향은, SP비(比)를 증가시켜도 강도물성(MOR, MOE, IB)은 향상되지 않으며, 오히려 저하되는 것도 있었다. 두께팽창율(TS)은 SP 비(比) 1:1 이상의 복합체에서는 S만으로 제조한 보드와 같은 정도의 값을 나타내었다.

  • PDF

Non-Gaussian time-dependent statistics of wind pressure processes on a roof structure

  • Huang, M.F.;Huang, Song;Feng, He;Lou, Wenjuan
    • Wind and Structures
    • /
    • 제23권4호
    • /
    • pp.275-300
    • /
    • 2016
  • Synchronous multi-pressure measurements were carried out with relatively long time duration for a double-layer reticulated shell roof model in the atmospheric boundary layer wind tunnel. Since the long roof is open at two ends for the storage of coal piles, three different testing cases were considered as the empty roof without coal piles (Case A), half coal piles inside (Case B) and full coal piles inside (Case C). Based on the wind tunnel test results, non-Gaussian time-dependent statistics of net wind pressure on the shell roof were quantified in terms of skewness and kurtosis. It was found that the direct statistical estimation of high-order moments and peak factors is quite sensitive to the duration of wind pressure time-history data. The maximum value of COVs (Coefficients of variations) of high-order moments is up to 1.05 for several measured pressure processes. The Mixture distribution models are proposed for better modeling the distribution of a parent pressure process. With the aid of mixture parent distribution models, the existing translated-peak-process (TPP) method has been revised and improved in the estimation of non-Gaussian peak factors. Finally, non-Gaussian peak factors of wind pressure, particularly for those observed hardening pressure process, were calculated by employing various state-of-the-art methods and compared to the direct statistical analysis of the measured long-duration wind pressure data. The estimated non-Gaussian peak factors for a hardening pressure process at the leading edge of the roof were varying from 3.6229, 3.3693 to 3.3416 corresponding to three different cases of A, B and C.

Highly transparent Pt ohmic contact to InGaN/GaN blue light-emitting diodes

  • Chul Huh;Kim, Hyun-Soo;Kim, Sang-Woo;Lee, Ji-Myon;Kim, Dong-Joon;Kim, Hyun-Min;Park, Seon-Ju
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제4권2호
    • /
    • pp.47-49
    • /
    • 2000
  • We report on the fabrication and characterization of InGaN/GaN multiple quantum well light emitting diode (LED) with a highly transparent Pt ohmic contact as a current spreading layer. The value of light transmittance of a Pt thin film with a thickness of 8 m on p-GaN was measured to be 85% at 450nm. The peak wavelength and the full-width at half-maximum (FWHM) of the emission spectrum of the LED at 20 mA were 453 m and 23 m, respectively. Pt-contacted LEDs show good electrical properties and high light-output efficiency compared to Ni/Au-contacted ones. These results suggest that a Pt thin film can be used as an effective current spreading layer with high light-transparency.

  • PDF

Electronic Structure of the SrTiO3(001) Surfaces: Effects of the Oxygen Vacancy and Hydrogen Adsorption

  • Takeyasua, K.;Fukadaa, K.;Oguraa, S.;Matsumotob, M.;Fukutania, K.
    • Applied Science and Convergence Technology
    • /
    • 제23권5호
    • /
    • pp.201-210
    • /
    • 2014
  • The influence of electron irradiation and hydrogen adsorption on the electronic structure of the $SrTiO_3$ (001) surface was investigated by ultraviolet photoemission spectroscopy (UPS). Upon electron irradiation of the surface, UPS revealed an electronic state within the band gap (in-gap state: IGS) with the surface kept at $1{\times}1$. This is considered to originate from oxygen vacancies at the topmost surface formed by electron-stimulated desorption of oxygen. Electron irradiation also caused a downward shift of the valence band maximum indicating downward band-bending and formation of a conductive layer on the surface. With oxygen dosage on the electron-irradiated surface, on the other hand, the IGS intensity was decreased along with upward band-bending, which points to disappearance of the conductive layer. The results indicate that electron irradiation and oxygen dosage allow us to control the surface electronic structure between semiconducting (nearly-vacancy free: NVF) and metallic (oxygen de cient: OD) regimes by changing the density of the oxygen vacancy. When the NVF surface was exposed to atomic hydrogen, in-gap states were induced along with downward band bending. The hydrogen saturation coverage was evaluated to be $3.1{\pm}0.8{\times}10^{14}cm^{-2}$ with nuclear reaction analysis. From the IGS intensity and H coverage, we argue that H is positively charged as $H^{{\sim}0:3+}$ on the NVF surface. On the OD surface, on the other hand, the IGS intensity due to oxygen vacancies was found to decrease to half the initial value with molecular hydrogen dosage. H is expected to be negatively charged as $H^-$ on the OD surface by occupying the oxygen vacancy site.

Highly transparent Pt ohmic contact to InGaN / GaN blue light - emitting diodes

  • Huh, Chul;Kim, Hyun-Soo;Kim, Sang-Woo;Lee, Ji-Myon;Kim, Dong-Joon;Kim, Hyun-Min;Park, Seong-Ju
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제4권3호
    • /
    • pp.78-80
    • /
    • 2000
  • We reprot on the fabrication and characterization of InGaN/GaN multiple quantum well light-emitting diode (LED) with a highly transparent Pt ohmic contact as a current spreading layer. The value of light transmittance of a Pt thin film with a thickness of 8 nm on-GaN was measured to be 85% at 450 nm. The peak wavelength and the full-width at half-maximum (FWHM) of the emission spectrum of the LED at 20 mA were 453 nm and 23 nm, respectively. Pt-contacted LEDs show good electrical properties and high light-output efficiency compared to Ni/Au-contacted ones. These results suggest that a Pt thin film can be used as an effective current spreading layer with high light-transparency.

  • PDF

치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구 (THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY)

  • 박태원
    • 치과방사선
    • /
    • 제9권1호
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF