• 제목/요약/키워드: h-system

검색결과 20,597건 처리시간 0.044초

An ESR Study of Amino Acid and Protein Free Radicals in Solution Part VI. Enzymatic Inactivation of Lysozyme in Aqueous Solution Resulting from Exposure to $Ti-H_2O_2$ System and Gamma-Irradiation

  • Hong, Sun-Joo;Piette, L.H.
    • 대한화학회지
    • /
    • 제16권2호
    • /
    • pp.80-83
    • /
    • 1972
  • The activity change of lysozyme resulted from its exposure to $Ti-H_2O_2$system in aqueous liquid at room temperature and to ${\gamma}$-irradiation in ice at $195^{\circ}K$ has been measured at room temperature with a Cary-14 spectrophotometer. The enzymatic activity of lysozyme which had been added to a previously flow-mixed solution of $TiCl_3$ and $H_2O_2$ (System I) was compared with the activity of a lysozyme-$H_2O_2$ solution after flow-mixing with $TiCl_3$ (System II), considering the differences between these two activity changes as the extent of the enzymatic inactivation by the involvement of OH radical reaction. The fraction of lysozyme inactivated by OH radical in the system containing 0.0025 M $TiCl_3-0.1M$ $H_2O_2$ (ph 3.5) was 13%, When the $TiCl_3$ concentration is double (pH 3.0), the fraction of enzyme inactivated increases to 36%. The activity of the system containing 0.025 M $TiCl_3-0.1$ M $H_2O_2$ (pH 1.5) was essentially zero. The results seem to support the previos view that the production of OH radical should be proportional to $TiCl_3$ concentration when $H_2O_2$ is present in excess. Increase in the extent of inactivation found in system I with increasing $TiCl_3$ concentration may be due to a pH effect. $H_2O_2$ seems to be less effective than $TiCl_3$ in the inactivation. 1% lysozyme solution, when ${\gamma}$-irradiated with a total dose of 3M rads, loses about 20% of its activity. Lowering of temperature also was found to yield a reduction in enzymatic activity.

  • PDF

디스크립터 시스템을 위한 혼합 $H_{2}/H_{\infty}$제어기의 설계 (Mixed $H_{2}/H_{\infty}$ Controller Design for Descriptor Systems)

  • Choe, Yeon-Wook
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권7호
    • /
    • pp.483-490
    • /
    • 2004
  • The descriptor system model has a high ability in representing dynamical systems. It can preserve physical parameters in the coefficient matrices, and describe the dynamic part, static part, and even the improper part of the system in the same form. The design of mixed $H_{2}/H_{\infty}$ controllers for linear time-invariant descriptor systems is considered in this paper. Firstly, an $H_2$ and $H_{\infty}$ synthesis problems fur a descriptor system are presented separately in terms of linear matrix inequalities (LMIs) based on the bounded real lemma. Then, we show that the existence of a mixed $H_2/H_{\infty}$ controller by which the $H_2$ norm of the second channel is minimized while keeping the $H_2$ norm bound of the first channel less than ${\gamma}$, is reduced to the linear objective minimization problem. The class of desired controllers that are assumed to have the same structure as the plant is parameterized by using the linearizing change of variables.

자기부상 시스템의 $H_{\infty}$ 제어 ($H_{\infty}$ control of magnetic suspension system)

  • 김종문;김춘경;박민국;김국헌
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.322-322
    • /
    • 2000
  • This paper shows an application of H$_{\infty}$ control design for a magnetic suspension system which has strongly nonlinearity and parameter perturbation. The control design is evaluated by numerical simulations and experiments.

  • PDF

DEVELOPMENT OF AN OPERATION STRATEGY FOR A HYBRID SAFETY INJECTION TANK WITH AN ACTIVE SYSTEM

  • JEON, IN SEOP;KANG, HYUN GOOK
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.443-453
    • /
    • 2015
  • A hybrid safety injection tank (H-SIT) can enhance the capability of an advanced power reactor plus (APR+) during a station black out (SBO) that is accompanied by a severe accident. It may a useful alternative to an electric motor. The operations strategy of the H-SIT has to be investigated to achieve maximum utilization of its function. In this study, the master logic diagram (i.e., an analysis for identifying the differences between an H-SIT and a safety injection pump) and an accident case classification were used to determine the parameters of the H-SIT operation. The conditions that require the use of an H-SIT were determined using a decision-making process. The proper timing for using an H-SIT was also analyzed by using the Multi-dimensional Analysis of Reactor Safety (MARS) 1.3 code (Korea Atomic Energy Research Institute, Daejeon, South Korea). The operation strategy analysis indicates that a H-SIT can mitigate five types of failure: (1) failure of the safety injection pump, (2) failure of the passive auxiliary feedwater system, (3) failure of the depressurization system, (4) failure of the shutdown cooling pump (SCP), and (5) failure of the recirculation system. The results of the MARS code demonstrate that the time allowed for recovery can be extended when using an H-SIT, compared with the same situation in which an H-SIT is not used. Based on the results, the use of an H-SIT is recommended, especially after the pilot-operated safety relief valve (POSRV) is opened.

스프링 연결 병렬형 탄성 역진자의 비선형 $H_2/H_\infty/LTR$ 제어 (Nonlinear $H_2/H_\infty/LTR$ Control of the Parallel Flexible Inverted Pendulum Connected by a Spring)

  • 한성익
    • 제어로봇시스템학회논문지
    • /
    • 제6권5호
    • /
    • pp.356-366
    • /
    • 2000
  • In this paper, a nonlinear $H_2/H_\infty/LTR$ control for the flexible inverted pendulum of a parallel type with Coulomb friction is presented. The dynamic equation for this system is derived by the Hamilton's principle and assumed-mode method. This hard nonlinear system can be modeled by a the quasi-linear state space model using the REF method. It is shown that the $H_2/H_\infty$ control can be applied to the nonlinear controller design of the system having Coulomb frictions if the proper LTR conditions are satisfied. In order to present the usefulness of the suggested control method, the nonlinear $H_2/H_\infty/LTR$ controller is designed to control the Position of the end point of the flexible inverted pendulum that has Coulomb frictions present in actuator parts. The results are given via computer simulations.

  • PDF

액제 정밀계량장치를 이용한 액제 자동조제 시스템개발 (Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device)

  • 류관희;홍순호;이규철;이정훈;황호준
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1997년도 하계 학술대회 논문집
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

강인한 성능을 가지는 모델추종형 $H_{\infty}$ 제어 시스템의 설계 (A Design on Model-Following $H_{\infty}$ Control System Having Robust Performance)

  • 황현준
    • 한국정보통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.913-921
    • /
    • 2009
  • 본 연구에서는 강인한 성능을 가지는 해집단내에서 기준모델의 출력을 최적으로 추종하도록 유전 알고리즘을 사용하여 가중치 함수와 설계 파라메타 ${\gamma}$를 동시에 최적화함으로써, 강인한 성능에 관한 필요충분조건식을 만족함은 물론 설계사양에 따른 만족스러운 응답특성을 보이는 강인한 성능을 가지는 모델추종형 $H_{\infty}$ 제어기의 설계법을 제시하고 시뮬레이션을 통하여 그 유용성을 확인한다.