• Title/Summary/Keyword: guiding

Search Result 1,051, Processing Time 0.03 seconds

A NEW AUTO-GUIDING SYSTEM FOR CQUEAN

  • CHOI, NAHYUN;PARK, WON-KEE;LEE, HYE-IN;JI, TAE-GEUN;JEON, YISEUL;IM, MYUNGSHI;PAK, SOOJONG
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.3
    • /
    • pp.177-185
    • /
    • 2015
  • We develop a new auto-guiding system for the Camera for QUasars in the EArly uNiverse (CQUEAN). CQUEAN is an optical CCD camera system attached to the 2.1-m Otto-Struve Telescope (OST) at McDonald Observatory, USA. The new auto-guiding system differs from the original one in the following: instead of the cassegrain focus of the OST, it is attached to the finder scope; it has its own filter system for observation of bright targets; and it is controlled with the CQUEAN Auto-guiding Package, a newly developed auto-guiding program. Finder scope commands a very wide field of view at the expense of poorer light gathering power than that of the OST. Based on the star count data and the limiting magnitude of the system, we estimate there are more than 5.9 observable stars with a single FOV using the new auto-guiding CCD camera. An adapter is made to attach the system to the finder scope. The new auto-guiding system successfully guided the OST to obtain science data with CQUEAN during the test run in 2014 February. The FWHM and ellipticity distributions of stellar profiles on CQUEAN, images guided with the new auto-guiding system, indicate similar guiding capabilities with the original auto-guiding system but with slightly poorer guiding performance at longer exposures, as indicated by the position angle distribution. We conclude that the new auto-guiding system has overall similar guiding performance to the original system. The new auto-guiding system will be used for the second generation CQUEAN, but it can be used for other cassegrain instruments of the OST.

Development of a Guiding System for the High-Speed Self-Align Cable Winding (고속 자동정렬 케이블 와인딩을 위한 가이딩 시스템 개발)

  • 이창우;강현규;신기현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.124-129
    • /
    • 2004
  • Recently, the demand for the optical cable is rapidly growing because the number of internee user increases and high speed internet data transmission is required. But the present optical cable winding systems has some serious problems such as pile-up and collapse of cable usually near the flange of the bobbin in the process of the cable winding. To reduce the pile-up collapse in a cable winding systems, a new guiding system is developed for a high-speed self-align cable winding. First of all, the winding mechanism was analyzed and synchronization logics for the motions of winding, traversing, and the guiding were created. A prototype cable winding systems was manufactured to validate the new guiding system and the suggested logic. Experiment results showed that the winding system with the developed guiding system outperformed the system without the guiding system in reducing pile-up and collapse in the high-speed winding.

Performance of KHU Auto-guiding Package for McDonald 82 inch Telecope (KAP82)

  • Lee, Hye-In;Pak, Soojong;Ji, Tae-Geun;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2015
  • In astronomical observations, stable auto-guiding and accurate target centering capabilities are critical to increase observation efficiency and sensitivity. Recently, Center for the Exploration of the Origin of the Universe (CEOU) has developed SQUEAN (SED camera for QUasars in EArly uNiverse). SQUEAN is installed and had successful observations at the 82 inch Otto Struve Telescope of McDonald Observatory in 2015 February. We have upgraded the existing auto-guiding softwares to KAP82 (KHU Auto-guiding Package for the McDonald 82 inch Telescope). Keeping the original hardware systems and the software algorithms of CAP (CQUEAN Auto-guiding Package), KAP 82 is completely re-written in Visual C++. We developed several center finding algorithms, e.g., 2D-gaussian fitting and weighted mean methods. In this presentation, we compare the auto-guiding performances with these algorithms.

  • PDF

Analysis on Transition between Index- and Bandgap-guided Modes in Photonic Crystal Fiber

  • Hong, Kee Suk;Lim, Sun Do;Park, Hee Su;Kim, Seung Kwan
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.733-738
    • /
    • 2016
  • We calculate optical properties of guided modes of a hybrid-guiding photonic crystal fiber. The design and modeling of such hybrid-guiding PCF is made by replacing air holes with inserts of high refractive index material layer by layer in order. The optical properties such as mode intensity profile, mode dispersion, optical birefringence, confinement loss, and chromatic dispersion during transition of the guiding mechanism are analyzed and discussed. The guided modes in the hybrid-guiding region are also compared with those of reference index-guiding and bandgap-guiding photonic crystal fibers.

The Development of the Shunt Guiding Kit for the Proper Positioning of the Proximal Shunt Catheter to the Lateral Ventricle in the Ventriculo-Peritoneal Shunt Operation (뇌실-복강간 단락술에서 Proximal Catheter의 정확한 측뇌실내로의 위치를 위한 Shunt Guiding Kit의 개발)

  • Shin, Yong Sam;kim, Se-Hyuk;Zhang, Ho Yeol;Bae, Ju Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.981-984
    • /
    • 2001
  • Object : To treat hydrocephalus by ventriculo-peritoneal shunt operation, the correct positioning of the proximal catheter in the ventricle is very important. The purpose of this study was to develop the "shunt guiding kit" for the proper positioning of the proximal shunt catheter to the ventricle in the ventriculo-peritoneal shunt operation. Materials and Methods: The "shunt guiding kit" is made of tungsten alloy and it consists of one frame, two screws and one guider. Through the guider, the proximal shunt catheter operates by mechanically coupling the posterior burr hole to the anterior target point. Results: We have treated three hydrocephalus patients with use of the "shunt guiding kit", and achieved good location of proximal shunt catheters. Conclusion: We developed the "shunt guiding kit" for the proper positioning of the proximal shunt catheter to the ventricle, and this would be very useful for preventing ventriculo-peritoneal shunt malfunction and preventing possible brain injury during the procedures.

  • PDF

A Study on the Design of a New Web Guiding Mechanism Using a Tilting Roller (롤의 웹 표면 수직방향 기울임을 이용한 새로운 웹 가이더 설계에 관한 연구)

  • Shin, Han-Shic;Jee, Hyuk-Jong;Shin, Kee-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.84-89
    • /
    • 2001
  • The alignment of the rollers carrying the web is found to be one of important factors to the lateral behavior of the moving web and to the quality of the final web products. But, the perfect alignment of the rollers is not always possible and the web itself can be cambered. Thus the control of lateral behavior of the moving web is critical in the most of web handling systems. The web guiding system that adjusts the angle of the alignment between two adjacent rollers is commonly used in industry. But, in this paper a new web guiding system is proposed by using the lateral dynamics of the moving web induced by a tilted roller in normal direction of a web. The computer simulation study was carried out to verify the steering performance of the suggested guiding system. Computer simulation study shows that the performance of the new guiding mechanism is better than that of an existing guiding mechanism.

  • PDF

[ ${\ulcorner}$ ]Standard Principles for the Designing of Prescriptions - The Theory for Monarch, Minister, Adjuvant and Dispatcher${\lrcorner}$ ("방제구성의 표준적 규격 - 군신좌사(君臣佐使)")

  • Kim Do-Hoy;Seo Bu-il;Kim Bo-Kyung;Kim Gyeong-Cheol;Shin Soon-Shik
    • Herbal Formula Science
    • /
    • v.11 no.2
    • /
    • pp.1-18
    • /
    • 2003
  • The Theory for Monarch, Minister, Adjuvant and Dispatcher (or the Theory of Principal, Assistant, Adjuvant and Guiding Korean Oriental Herbal Medicines) has served as a standard principle for newly developed prescription formulas as well as established ones. Despite its significance, however, this theory hasn't been thoroughly studied and covered in the academic journals of Korean Oriental Herbal Medicines (KOHM) yet. This paper inquires into the origin of the theory while presenting the definitions and functions of Principal, Assistant, Adjuvant, and Guiding KOHM. In the end, the recommended doses and number of the KOHM comprising each of Principal, Assistant, Adjuvant, and Guiding KOHM are suggested. The compatibility theory of Principal, Assistant, Adjuvant, and Guiding KOHM can be traced back to the Warring States Period during which it was recorded in the treatise of the various schools of thoughts and their exponents. The theory was firmly established as a full system in ${\ulcorner}Shinnong's\;Pharmacopoeia{\lrcorner}\;and\;{\ulcorner}Yellow\;Emperor's\;Cannon\;of\;Internal\;Medicine{\lrcorner}$. While ${\ulcorner}Shinnong's\;Pharmacopoeia{\lrcorner}$ focuses on the classification of the properties of KOHM, ${\ulcorner}Yellow\;Emperor's\;Cannon\;of\;Internal\;Medicine{\lrcorner}$ mainly deals with the principles for writing prescriptions. In this regard, it is ${\ulcorner}Yellow\;Emperor's\;Cannon\;of\;Internal\;Medicine{\lrcorner}$ that systemized the Theory of Principal, Assistant, Adjuvant, and Guiding KOHM in a real sense. Principal KOHM aims at the causes of diseases and treat main symptoms. The doses are greater than Assistant, Adjuvant and Guiding KOHM. With their comprehensive effects, Principal KOHM is a leading ingredient of any prescription formula. Assistant KOHM are similar to Principal KOHM in its natures and flavors. Although its natures, flavors as well as efficacies may slightly differ from those of Principal KOHM, Assistant KOHM strengthens the therapeutic effects, jointly working with Principal KOHM. They mainly treat accompanying diseases and symptoms. Adjuvant KOHM is divided into two types: facilitator and inhibitor. Facilitators with the similar properties to those of Principal and Assistant KOHM help strengthen the therapeutic effects. Since they usually treat accompanying symptoms or secondary accompanying symptoms (minor accompanying symptoms), there are two kinds of facilitators. (1) The first kind of facilitators assists Principal KOHM, targeting accompanying symptoms. (2) The second ones supporting Assistant KOHM are for accompanying or secondary accompanying symptoms (or minor accompanying symptoms). Inhibitors counteract and thereby complement Principal and Assistant KOHM. Some of them inhibit the side effects or toxicity of Principal KOHM for the sake of the safety of the whole prescription formula while the others generate induced interactions. Guiding KOHM can be used for two purposes: guiding and mediating. The Guiding KOHM for the former purpose leads the other KOHM in a prescription formula to the lesion. But, the Guiding KOHM for mediating coodinate and harmonize all the ingredients in a prescription formula. The number of KOHM for those Principal, Assistant, Adjuvant and Guiding KOHM and their doses are different, depending on the types of prescriptions: classical prescriptions, prescriptions after ${\ulcorner}$Treatise of Cold-Induced Diseases${\lrcorner}$ and prescriptions of Sasang Constitutions Medicines. In the case of the prescriptions after ${\ulcorner}$Treatise of Cold-Induced Diseases${\lrcorner}$, it is highly recommended to follow the view of ${\ulcorner}$Thesaurus of Korean Oriental Medicine Doctors in Chosun Dynasty${\lrcorner}$ for the number of KOHM to be used. For the doses, however, ${\ulcorner}$Elementary Course for Medicine${\lrcorner}$, is found to be more accurate. The most appropriate number of KOHM per prescription is 11-13. To be more specific, for one prescription formula, it is recommended to administer one kind of KOHM for Principal KOHM, 2-3 for Assistant KOHM, 3-4 for Adjuvant KOHM and 5 for Guiding KOHM. As for the proportion of the doses, when 10 units are to be administered for Principal KOHM in a formula, the doses for the other three should be 7-8 units for Assistant KOHM, 5-6 for Adjuvant KOHM and 3-4 for Guiding KOHM. The doses of the KOHM added to or taken out of the prescription correspond to those of Adjuvant and Guiding KOHM.

  • PDF

Enhancing Connectivity of Guiding Points at Road Signs (도로표지 안내지명의 연계성 확보 방안)

  • Kim, Eung-Cheol;Lee, Tae-Yoon;Kwon, Young-In
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.37-47
    • /
    • 2006
  • The road sign is one of street furnitures functioning to guide directions for drivers. The road sign should be employed and designed to help drivers find their destinations easily and accurately. It is obvious that the road sign is one of the main components that enhance efficiency and safety of driving environments. The current way of guiding strategy at road signs in Korea is a system for mainly guiding 'points' although a new system guiding 'road names' and 'street numbers' with the introduction of new address system is now being introduced on urban areas. When the regional territory management offices and local governments try to employ current road sign systems, they are supposed to follow the sign regulations which contains standard project processes, selection methods of guiding points, character size and design, and location selection for each road sign. However, the current road sign regulations are very complex to understand and unclear for a person in charge to do tasks described above. Especially, selection process and criteria of guiding points are cumbersome and controversial. Furthermore, non sufficient ways of selecting guiding points considering road functions and geographic characteristics decrease the connectivity of guiding points. This study develops enhanced ways of increasing connectivity of successive guiding points through three case studies. Developed ways will help highway agencies and officials understand how to improve the connectivity of road signs.

  • PDF

A Development of a Guiding System for the High-Speed Self-Align Cable Winding (고속 자동정렬 케이블 와인딩을 위한 가이딩 시스템 개발)

  • 이창우;강현규;지혁종;안영세;신기현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.478-482
    • /
    • 2002
  • Recently, the demand for the optical cable is rapidly glowing because the number of internet user increases and high speed internet data transmission is required. To meet this demand, it is necessary to have a sufficient manufacturing capability for mass and high-quality production. But the present optical cable winding system has some serious problems such that the optical cable of radius (6 mm -40 mm) is often piled up and collapsed usually at the edge of the bobbin in the process of the cable winding. It is often necessary to have an additional operator in order to adjust the cable, which causes the productivity decrease. In order to improve a performance of cable winding system which deals with relatively thick cable( radius : 6 mm -40 mm ), we developed a new guiding system for a high-speed self-align cable winding. First of all, the winding mechanism was analyzed. Synchronization logics for the motions of winding, traversing, and the guiding were created and implemented by using the PLC and guiding system controller in a prototype cable winding system manufactured in the CILS( Computer Integrated Large scale System ) lab. An experimental verification was carried out to validate the logic. Results showed that the winding system with the developed guiding system outperformed in reducing pile-up and collapse in the high-speed winding(up to 300 mm/s) compared with the system without the guiding system.

  • PDF

Effects of Manual Postural Correction on the Trunk and Hip Muscle Activities During Bridging Exercises (도수적 자세교정이 슬링을 이용한 교각운동 시 체간과 하지 근육의 근활성도에 미치는 영향)

  • Kim, So-Young;Kim, Suhn-Yeop;Jang, Hyun-Jeong
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.38-44
    • /
    • 2014
  • The aim of this study was to investigate the effects of different postural correction in the electromyographic (EMG) activity of the trunk and hip muscles during bridging exercises. Twenty-four healthy subjects volunteered for this study. The muscle activity was recorded with surface electrodes over the erector spinae, multifidus, gluteus maximus (GM), and hamstring (Ham) muscles; it was measured by using surface EMG equipment under the following 3 experimental conditions: manual postural correction, verbal correction, and no correction. The maximal voluntary isometric contraction (MVIC) was determined for each muscle group in order to represent each exercise as a percentage of MVIC and allow for standardized comparison between subjects. A one-way analysis of variance was used to determine significant differences in the EMG activities of each muscle between the 3 experimental groups. During bridging exercises, the manual postural correction on normalized EMG activity of the GM muscle during manual guiding was significantly higher than during verbal guiding and without guiding (p<.05). Furthermore, the GM/Ham ratio was significantly higher during manual guiding than during verbal guiding and without guiding (p<.05). These findings suggest that the activities of the hip and trunk muscles may be favorably modified with manual guiding during bridging exercises.