• 제목/요약/키워드: guided surgery

검색결과 573건 처리시간 0.024초

광범위 당뇨병성 족부 및 하퇴부 궤양의 피부이식술에 사용된 초음파 유도 신경 차단: 술기 보고 (Ultrasound-guided Nerve Block for Skin Grafting on Large Diabetic Ulcer of Foot and Leg: A Technical Report)

  • 송재황;강찬;황득수;황정모
    • 대한족부족관절학회지
    • /
    • 제18권3호
    • /
    • pp.133-136
    • /
    • 2014
  • Skin grafting is often required for diabetic ulcerative foot lesions. In skin grafting, effective regional or local anesthesia into the donor and recipient areas plays a significant role in continuous control of pain. We report on a technique of ultrasound-guided nerve block on the femoral, sciatic, and lateral femoral cutaneous nerves in large split-thickness skin grafting for ulcer of the foot and leg.

요추 및 천추부에 대한 초음파 유도하 중재 시술 (Ultrasound-Guided Injections in the Lumbar and Sacral Spine)

  • 고광표;송재황;김환정;김상범;민영기
    • 대한척추외과학회지
    • /
    • 제25권4호
    • /
    • pp.185-195
    • /
    • 2018
  • 연구 계획: 문헌 조사 목적: 초음파를 이용한 중재 시술은 임상적으로 흔하게 경험할 수 있는 하요추부 통증이 보존적 치료에 실패한 경우 수술적 치료 이전에 흔하게 시행하게 되는 치료이다. 이 연구의 목적은 요추 및 천추부에 대한 초음파 유도하 중재 시술에 대해 고찰해 보고자 함에 있다. 선행 연구문헌의 요약: 초음파를 이용한 중재 요법은 근육, 인대, 건, 혈관, 신경 등의 연부조직을 직접 관찰할 수 있으며, 환자나 시술자에게 방사선 노출이 없고, 컴퓨터 단층 촬영이나 C형 투시검사 장비처럼 넓은 장소를 필요로 하지 않는 장점들을 가지고 있기 때문에 점차 그 사용이 늘고 있다. 대상 및 방법: 요추부의 정상, 비정상 초음파 소견과 요추 및 천추부에서 시행할 수 있는 초음파 유도하 중재 요법에 대하여 문헌 고찰과 함께 기술을 하였다. 결과: 요천추부의 정확한 초음파 중재 시술을 위해서는 검사 시 환자의 자세 및 해부학과 정상, 비정상 초음파 소견 등에 대한 숙지가 필요하다. 초음파를 이용하면 후방 관절 내 주사 및 내측 분지 차단술, 경막외 차단술, 선택적 신경근 차단술, 천장관절 주사를 효과적으로 시행할 수 있다. 결론: 요추 및 천추부에서 초음파 유도하 중재 요법은 요천추부 통증의 치료에서 효과적으로 사용할 수 있는 술기이다.

비촉지성 갑상선 결절의 진단에서 초음파 유도하 세침검사법의 임상적 가치 (A Clinical Significance of Ultrasound Guided Aspiration Cytology in Diagnosis of Impalpable Thyroid Nodule)

  • 최낙선;윤정한;제갈영종
    • 대한두경부종양학회지
    • /
    • 제15권2호
    • /
    • pp.189-193
    • /
    • 1999
  • Objectives: Fine needle aspiration cytology(FNAC) is a well established preoperative diagnostic procedure in the thyroid nodules. However, diagnostic accuracy of FNAC varies according to the size and the structural characteristics of thyroid nodule. We performed the ultrasound guided FNAC(US-guided FNAC) for impalpable thyroid nodule, and estimated the sampling accuracy rate through a comparison study between the cytologic diagnosis and the final histologic diagnosis of the postoperative specimens in order to determine clinical efficacy of the US-guided FNAC. Materials and Methods: We evaluated 117 patients underwent US-guided FNAC from January 1997 to December 1998. These patients had 129 thyroid nodules to need cytologic examination. Whereas the nodules were so no graphically classified into cystic, solid, and mixed type according to echo pattern, the aspirated thyroid specimens were classified into benign, malignant, suspicious, and insufficient. Results: Positive sampling for diagnositc examination was achieved in 75 nodules(58.1%), and US-guided FNAC in our study showed the accuracy rate of 95.2%, false positivity rate of 0%, and false negativity rate of 5.5%. Conclusions: US-guided FNAC is a powerful techniques for evaluating cytologic characterics and allowing a reliable diagnositc result in the impalpable thyroid nodule. However, the experienced technique is recommanded in order to obtain the sufficient samples for reliable results.

  • PDF

A Randomized Comparative Study of Blind versus Ultrasound Guided Glenohumeral Joint Injection of Corticosteroids for Treatment of Shoulder Stiffness

  • Lee, Hyo-Jin;Ok, Ji-Hoon;Park, In;Bae, Sung-Ho;Kim, Sung-Eun;Shin, Dong-Jin;Kim, Yang-Soo
    • Clinics in Shoulder and Elbow
    • /
    • 제18권3호
    • /
    • pp.120-127
    • /
    • 2015
  • Background: We prospectively compared the response to blind and ultrasound-guided glenohumeral injection of corticosteroids for treatment of shoulder stiffness. Methods: A total of 77 patients with shoulder stiffness between April 2008 and March 2012 were recruited. Patients were randomized to receive either a blind (group 1, n=39) or ultrasound-guided (group 2, n=38) glenohumeral injection of 40 mg triamcinolone. The clinical outcomes and shoulder range of motion (ROM) before injection, at 3, 6, and 12 months after injection and at the last follow-up were assessed. The same rehabilitation program was applied in both groups during the follow-up period. Results: There was no significant difference in demographic data on age, sex, ROM, and symptom duration before injection between groups (p>0.05). There were no significant differences in ROM including forward flexion, external rotation at the side, external rotation at $90^{\circ}$ abduction, and internal rotation, visual analogue scale for pain and functional outcomes including American Shoulder and Elbow Surgeons score, Simple Shoulder test between the two groups at any time point (p>0.05). Conclusions: Based on the current data, the result of ultrasound-guided glenohumeral injection was not superior to that of blind injection in the treatment of shoulder stiffness. We suggest that ultrasound-guided glenohumeral injection could be performed according to the patient's compliance and the surgeon's preference. Once familiar with the non-imaging-guided glenohumeral injection, it is an efficient and reliable method for the experienced surgeon. Ultrasound could be performed according to the surgeon's preference.

임플란트 식립시 동종뼈 막의 임상적 활용 (CLINICAL USES OF HOMOLOGOUS GELATINIZED BONE MATRIX(GBM) IN DENTAL IMPLANT SURGERY)

  • 이은영;김경원;엄인웅
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권3호
    • /
    • pp.229-236
    • /
    • 2006
  • The biologic principle of guided bone regeneration(GBR) has been studied extensively in hopes of regenerating alveolar bone. Various materials have been utilized as regenerative membranes and grafting materials in implant surgery. To improve the ability of membranes, several types of membrane have been developed. Various materials have been utilized as regenerative membranes; however, all materials have disadvantages, and the ideal membrane material is yet to be identified. In these cases, a homologous gelatinized bone matrix(GBM) were used as a regenerative material in conjunction with the placement of endosseous root implants. 22 patients participated in this study, and 42 implants were inserted. The result of 1st operative surgery was uneventful, inflammatory reaction and dehiscences were not observed except for only one case. After the final protheses, all implants were functioning successfully. The major advantages in the use of GBMs for guided bone regeneration are of very wide application such as membrane and graft material, and that a second procedure to remove the material is not necessary, and the GBMs are accepted by the surrounding tissues without complications. The purpose of this study was to observe the usefulness of GBMs in dental implant surgery.

Risk Factors for Wound Dehiscence after Guided Bone Regeneration in Dental Implant Surgery

  • Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권3호
    • /
    • pp.116-123
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate risks for wound dehiscence after guided bone regeneration (GBR) in dental implant surgery. Methods: Patients who received dental implant therapy with GBR procedure at Seoul National University Bundang Hospital (Seongnam, Korea) from June 2004 to May 2007 were included. The clinical outcome of interest was complications related to dental implant surgery. The factors influencing wound dehiscence, classified into patient-related factors, surgery-related factors and material-related factors, were evaluated. Results: One hundred and fifteen cases (202 implants) were included in this study. Wound dehiscence (19.1%) was considered a major complication. The risk of wound dehiscence was higher in males than in females (odds ratio=4.279, P =0.014). In the main graft, the allogenic group had the lowest risk of wound dehiscence (odds ratio=0.106, P =0.006). Though the external connection group had a higher risk of wound dehiscence than the internal connection group (odds ratio=2.381), the difference was not significant (P =0.100). Conclusion: In this study, male gender and main graft have the highest risk of wound dehiscence. To reduce wound dehiscence after GBR, instructions on postoperative care with supplementary procedure for the protection of the wound dehiscence is recommended, especially to male patients. A main graft with a gel base can reduce the risk of wound dehiscence.

Minimally Invasive Approach to Esophageal Perforation after Endoscopic Ultrasound-Guided Fine-Needle Aspiration: A Report of 2 Cases

  • Geraedts, Anna C.M.;Broos, Pieter P.H.L.;Gronenschild, Michiel H.M.;Custers, Frank L.J.;Hulsewe, Karel W.E.;Vissers, Yvonne L.J.;de Loos, Erik R.
    • Journal of Chest Surgery
    • /
    • 제53권5호
    • /
    • pp.313-316
    • /
    • 2020
  • Esophageal perforation after endoscopic ultrasound-guided fine-needle aspiration for mediastinal staging is a rare but severe complication. We report 2 cases of patients with esophageal perforation who were treated using video-assisted thoracoscopic surgery in combination with esophageal stenting. Through these cases, the feasibility of minimally invasive thoracic surgery was evaluated.

Computer-Assisted Mandibular Reconstruction with Monocortical DCIA Flap; A Case Report

  • Moon, Seong-Yong
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권2호
    • /
    • pp.83-86
    • /
    • 2015
  • Recently, computer-assisted surgery is popular for performing well-planned operations. Computer-aided navigation system is helpful in maxillofacial surgery with real time instrument positioning and clear anatomic identification. Generally, segmental mandibulectomy and reconstruction flap surgery have done by extra-oral approach such as, submandibular approach. This case report describes performing intra-oral segmental mandibulectomy and reconstruction with monocortical deep circumflex iliac artery (DCIA) flap and CT guided implant surgery by using computer-aided surgical guide and navigation for managing ameloblastoma in a 31 years old female patient.

Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례 (Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis)

  • 김성모;박진홍;류재준;신상완;이정열
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.126-133
    • /
    • 2018
  • Cone beam computerized tomography (CBCT)의 발전은 환자의 해부학적 구조를 3차원적으로 분석할 수 있게 하였다. Surgical guide는 CBCT와 CAD/CAM, 임플란트 진단 소프트웨어의 접목을 통해 미래의 보철물을 계획하고 적합한 위치에 임플란트를 식립할 수 있게 한다. Guided surgery를 통해 해부학적 구조물에 대한 침범을 최소한으로 줄일 수 있고 보다 재현성 있는 치료계획의 설정이 가능하다. 본 증례는 전악 무치악 환자에게 surgical guide를 이용하여 다수의 임플란트를 식립한 증례로 수술시간을 단축시킬 수 있었으며 임시 보철물을 미리 제작함으로써 보다 쉽게 immediate loading을 시행할 수 있었다. 환자는 개선된 안모와 저작기능에 만족하였다.

Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm$^{(R)}$ Guided Methods

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권3호
    • /
    • pp.204-209
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm$^{(R)}$ system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. Methods : Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws from T5 to S1 in 45 patients. The position of screws within the pedicle was classified into four groups, from grade 0 (no violation cortex) to 3 (more than 4 mm violation). The location of violated pedicle cortex was also assessed. Intra-operative parameters including time required for preparation of screwing procedure, times for screwing and the number of X-ray shot were assessed in each group. Results : Grade 0 was observed in 186 (91.2%) screws of the fluoroscopy-guided group, and 99 (93.4%) of the navigation-guided group. Mean time required for inserting a screw was 3.8 minutes in the fluoroscopy-guided group, and 4.5 minutes in the navigation-guided group. Mean time required for preparation of screw placement was 4 minutes in the fluoroscopy-guided group, and 19 minutes in the navigation-guided group. The fluoroscopy-guided group required mean 8.9 times of X-ray shot for each screw placement. Conclusion : The screw placement under the navigation-guidance coupled with O-arm$^{(R)}$ system appears to be more accurate and safer than that under the fluoroscopy guidance, although the preparation and screwing time for the navigation-guided surgery is longer than that for the fluoroscopy-guided surgery.