• Title/Summary/Keyword: growth simulation

Search Result 1,090, Processing Time 0.032 seconds

Analysis of the Bottom Groove in L-shaped Profile Ring Rolling (L형상 프로파일 링롤링 공정의 하부면 그루브 결함 분석)

  • Oh, I.Y.;Hwang, T.W.;Kang, P.G.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.27 no.5
    • /
    • pp.289-295
    • /
    • 2018
  • The profile ring rolling process can realize various ring shapes unlike conventional rectangular cross-sectional ring products. In this paper, the defective groove in the bottom surface of L-shaped ring products was analyzed. Grooves are generated by non-uniform external forces due to profile main roll and initial blank shape. Process parameters such as the motion of dies and working temperature were determined. Mechanism of groove formation was analyzed by FE simulation on the basis of local external forces acting on the blank. Analysis results were similar to the groove actually occurring in the production line. Based on results of the analysis, two solutions were proposed for the groove. The position of the base plate supporting the blank was adjusted and edge length of the main roll was extended to suppress growth of grooves. It has been verified that groove was improved by applying two proposed methods in the shop-floor.

Comparison of Hygrothermal Performance between Wood and Concrete Wall Structures using Simulation Program

  • Yu, Seulgi;Chang, Seong Jin;Kang, Yujin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.283-293
    • /
    • 2016
  • Owing to an increase in the air tightness of recent buildings, the natural ventilation rate was significantly lowered and the removal of accumulated moisture became difficult in these buildings. The hygrothermal performance of these buildings should be carefully considered to provide comfortable indoor environment by removing the moisture condensation risk and the mold growth potential. In this study, hygrothermal performance of two selected wall structures was investigated based on WUFI simulation program. The results displayed that the indoor temperature had impact on the moisture accumulation in the insulation layer for both modeled walls, showing that lower indoor temperature resulted in higher moisture accumulation, especially in the wood frame structure. Also, the yearly moisture accumulation profile exhibited a downward shift throughout the year by adding a vapour retarder with a lower sd-value. In addition, both of the two walls have condensation risk in winter, due to low temperature level. The wood frame structure has a bigger fluctuation and higher condensation risk than the concrete structure.

Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings (노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교)

  • Lhee, Sang-Choon;Choi, Young-Joon;Kim, Hyun-Ki;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.

Evaluating Performance of Energy Conservation Measures on Energy-Efficient Remodeling at Deteriorated High School Buildings (노후 고등학교 건물의 에너지효율화 리모델링을 위한 요소기술의 성능 평가)

  • Lhee, Sang Choon;Choi, Young Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.97-102
    • /
    • 2013
  • Many countries over the world have acknowledged the global warming problem by greenhouse gas emission and tried to solve the problem. The Korean government has also taken many actions such as The Act on Low Carbon, Green Growth and on Promoting Green Building in that architectural building section takes 1/4 of national greenhouse gas emission. Under the situation that buildings constructed 15 years ago when insulation standards were reinforced take about 74%, The Plan on Vitalizing Green Remodeling, finally established on July 2013, will induce energy-efficient remodeling of deteriorated buildings. Using the energy simulation by the Visual DOE 4.0 program, this paper proposed the ways of energy-efficient remodeling of deteriorated high school buildings by measuring energy saving performance of factors that were drawn from the previous study. The factors considered are insulation, window's SHGC, south louver, system efficiency, and indoor setting temperature. Among them, all factors except SHGC proved contribution to reducing energy use at deteriorated high school buildings, compared with the baseline energy consumption.

Drift Velocities for Electrons in $SF_6$-Ar Mixtures Gas ($SF_6-Ar$-혼합기체(混合氣體)의 전자(電子) 이동속도(移動速度))

  • Kim, Sang-Nam;Ha, Sung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1102-1105
    • /
    • 2003
  • Energy distribution function for electrons in $SF_6$-Ar mixtures gas used by MCS-BEq algorithm has been analysed over the E/N range $30{\sim}300[Td]$ by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2(%) and 0.5(%) $SF_6$-Ar mixtures were measured by time-of-flight(TOF) method, The results show that the deduced electron drift velocities, Electrons Drift Velocities for a rang of E/N values. As a consequence, it was known that the spatial growth rates and the dielectric behaviors in $SF_6$-Ar mixtures are strongly dependent on the addition rate of $SF_6$ gas but the transport coefficients of electrons are insensitive to the addition rate of $SF_6$ gas. The results obtained from Boltzmann equation method and Monte Carlo simulation have been compared with present and previously obtained data and respective set of electron collision cross sections of the molecules.

  • PDF

A Study on the Evaluation Method for the Degree of Integration towards Office Towers in Different Climate Zones

  • Han, Seung-Hoon;Moon, Jin Woo;Kim, Kyoung-Hee
    • Architectural research
    • /
    • v.14 no.4
    • /
    • pp.117-124
    • /
    • 2012
  • High rise office buildings represent one of the most energy-intensive architectural typologies. The growth of urban population necessitates sustainable high rise towers that lessen environmental impacts and energy consumption. Among various sustainable strategies, the integrated design is long known to be an important process that has great impact on building's sustainability. The framework for this paper is based on the case study of integrated towers that are located in different climate zones. The paper specifically addresses to what extent climate conditions influence the design of a high rise building and what kinds of the climate integrated design has been implemented. Qualitative case studies were carried out using published data and architectural drawing set. The technical work presented in the paper is based on computer simulation that examines the insolation analysis using hourly recorded weather data. The analysis results revealed that the site and building envelope integration and the site and building service systems have shown the most frequently employed in the integrated towers through the implementation of renewable resource integration, high performance envelopes and sustainable building service systems. Internal comfort and further energy saving in the integrated towers are offered through an automatic building management system. Due to the dynamic climate conditions, integration of building systems requires a sophisticated approach to building sustainability.

Numerical study on heterogeneous behavior of fine particle growth

  • FAN, Fengxian;YANG, Linjun;Yuan, Zhulin;Yan, Jinpei;Jo, Young Min
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.171-178
    • /
    • 2009
  • $PM_{2.5}$ is one of critical air pollutants due to its high absorbability of heavy metallic fumes, PAH and bacillary micro organisms. Such a fine particulate matter is often formed through various nucleation processes including condensation. This study attempts to find the nucleation behaviors of $PM_{2.5}$ arisen from coal power stations using a classical heterogeneous Fletcher's theory. The numerical simulation by C-language could approximate the nucleation process of $PM_{2.5}$ from water vapor, of which approach revealed the required energy for embryo formation and embryo size and nucleation rate. As a result of the calculation, it was found that wetting agents could affect the particle nucleation in vapor condensation. In particular, critical contact angle relates closely with the vapor saturation. Particle condensation could be reduced by lowering the angles. The wetting agents aid to decrease the contact angle and surface tensions, thereby may contribute to save the formation energy.

  • PDF

Investigation of the effects of free-stream turbulence on wind-induced responses of tall building by Large Eddy Simulation

  • Li, Q.S.;Hu, G.;Yan, Bo-Wen
    • Wind and Structures
    • /
    • v.18 no.6
    • /
    • pp.599-618
    • /
    • 2014
  • In this study, a square rectangular tall building is considered to investigate the effects of turbulence integral length scale and turbulence intensity on the along-wind responses, across-wind responses and torsional responses of the tall building by Large Eddy Simulation (LES). A recently proposed inflow turbulence generator called the discretizing and synthesizing random flow generation (DSRFG) approach is applied to simulate turbulent flow fields. It has been proved that the approach is able to generate a fluctuating turbulent flow field satisfying any given spectrum, desired turbulence intensity and wind speed profiles. Five profiles of turbulence integral length scale and turbulence intensity are respectively generated for the inflow fields by the DSRFG approach for investigating the effects of turbulence integral length scale and turbulence intensity on the wind-induced responses of the tall building. The computational results indicate that turbulence integral length scale does not have significant effect on the along-wind (displacement, velocity and acceleration) responses, across-wind displacement and velocity responses, while the across-wind acceleration and torsional responses vary without a clear rule with the parameter. On the other hand, the along-wind, across-wind and torsional responses increase with the growth of turbulence intensity.

Estimate for Ensuring sight Distance of Curve Section from Consideration of the Environmental Impact Assessment based on the 3D GIS (3차원 GIS기법으로 환경영향을 고려한 곡선부 시거 안정성 분석)

  • Choi Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.4
    • /
    • pp.700-705
    • /
    • 2006
  • The latest system of GIS has been changing from 2 dimension to 3 dimension. According to the rapid growth of the fields linked to 3D GIS, 3D GIS has variously affected the public field, the national defense field. and the industrial field. This study estimated sight distance safety of curve section considering the environmental impact based on 3D GIS. Sight distance is calculated from the relation between road which keeps the three-dimension character and driver gaze, so it needs to consider both plane and vertical for the accurate measuring. This study made analysis of the sight distance through considering the environmental impact with driving simulation of design speed 80km/h and running speed 60-120km/h.

Simulation-based Yield-per-recruit Analysis of Pacific cod Gadus macrocephalus in Southeastern Korean Coastal Waters (모의실험을 통한 동남해안 대구(Gadus macrocephalus)의 가입당 생산 분석)

  • Cha, Hyung Kee;Jung, Sukgeun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.5
    • /
    • pp.493-498
    • /
    • 2012
  • We derived biological reference points for Pacific cod Gadus macrocephalus in southeastern Korean waters by applying a yield-per-recruit analysis based on a daily simulation that adopted size-dependent fecundity, growth, and natural mortality functions. This showed that the yield per recruit of Pacific cod can be maximized at an instantaneous rate of fishing mortality (F)=0.37 $yr^{-1}$ under the current regulations, where the minimum catch size ($L_c$)=30 cm in total length (TL). The maximum economic yield was estimated to be attained at $L_c$=35-45 cm TL, if F>1 $yr^{-1}$ but at $L_c$=35-40 cm TL, if F<1 $yr^{-1}$. Despite great uncertainty in the stock assessment, to develop fisheries management plans for the sustainable exploitation of Pacific cod in southeastern Korean waters, it is necessary to estimate F using capture-recapture or other expedient methods.