• Title/Summary/Keyword: group detection

Search Result 1,677, Processing Time 0.505 seconds

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

The Clinical Characteristics of Lung Cancer in Patients with Idiopathic Pulmonary Fibrosis (특발성 폐섬유화증에 동반된 폐암 환자의 임상적 특정)

  • Park, Joo-Hun;Lee, Jin-Seong;Song, Koun-Sik;Shim, Tae-Sun;Lim, Chae-Man;Koh, Youn-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Won-Dong;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.674-684
    • /
    • 1999
  • Background : It has been generally known that the incidence of lung cancer is higher in the patients with idopathic pumonary fibrosis (IPF) than those in general population. The reported incidence was variable from 4.8 to 43.2%. There were controversies on the most frequent cell type (squamous cell carcinoma vs. adenocarcinoma) and no study was done about the real concordance of cancer and the fibrotic lesion. And the pulmonary fibrosis may influence not only the development of cancer but also the treatment and prognosis of the cancer, but there was no report on that point. Method : Total 63 patients ($66.8{\pm}7.8$ year, M : F=61 : 2) were diagnosed as IPF combined with lung cancer (IFF-CA) at Asan Medical Center. A retrospective analysis was done about the risk factors of the lung cancer, pulmonary function test, the site of cancer(especially the relationship of the cancer with the fibrotic lesion), the histologic types, and the stage of cancer. The histologic types were compared with those of 2,660 patients with lung cancer who were diagnosed at the same institute for the same period. The effect of IPF on the treatment of the cancer was evaluated with the survival time after the detection of lung cancer. Results : The lung cancer was found in 63(22.9%) out of 281 patients with IPF. But in most of them(45 patients), lung cancer was detected at the same time with IPF and only in 18 patients, the cancer was diagnosed during the follow-up($25.2{\pm}17.7$ months) of IPF. So in our study, 6.7% of patients with IPF developed lung cancer during the course of the disease. The age ($66.8{\pm}7.84$ vs. $63.4{\pm}11.1$ years), percentage of smoker (88.9 vs. 67.2%), and the male gender (96.8 vs. 67.6%) were significantly higher in IPF-CA compared with lone IPF (p<0.05). The odds ratio of smoking was 4.7 compared with non smoking IPF controls. The lung cancer was located more frequently in the upper lobe and 55.5% was in the periphery of lung. The cancer was developed in the fibrotic lesion in 23 patients (35.9%), and in the majority of the patients, the cancer was separated from the fibrosis. The cell type of the lung cancer in IPF-CA was squamous cell carcinoma 34.9%, adenocarcinoma 30.2%, small cell carcinoma 19.0%, large cell undifferenciated carcinoma 6.3%, and others 9.5%. No significant difference in the distribution of histologic type of the lung cancer was found between IPF-CA and lone lung cancer. There was no significant difference in demographic features, cell types, location and the stage of the cancer between the group with concurrent IPF-CA and the group with cancer diagnosed during the follow up of IPF. There was a tendency (but statistically not significant : p=0.081) of higher incidence of adenocarcinoma among the cancers developed in the fibrotic area(43.5%) (F-CA) than in the cancers in non-fibrotic area (22.5%) (NF-CA). The prognosis of the patients with F-CA was poor (median survival : 4 months) compared with the patients with NF-CA (7 months, p=0.013), partly because the prevalence of severe IPF (the extent of fibrosis in HRCT 50%) was higher in F-CA group. Conclusion : These data suggest that the lung cancer in the patients with IPF has similar features to the ordinary lung cancer.

  • PDF

Development of Detection Method for Oilfish (Ruvettus pretiosus and Lepidocybirium flavobrunneum) as a Food Materials not Usable in Foods (식품원료로 사용금지 대상인 기름치 (기름갈치꼬치 및 흑갈치꼬치) 판별법 개발)

  • Park, Yong-Chjun;Kim, Mi-Ra;Jung, Yong-Hyun;Shin, Joon-Ho;Kim, Kyu-Heon;Lee, Jae-Hwang;Cho, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.50-55
    • /
    • 2013
  • Since 1 June 2012, it is prohibited to sell oilfish as a food material but there are still many illegal cases of selling oilfish as if it is tuna or grilled Patagonian toothfish. So it is absolutely crucial to construct the system to distinguish the real food material from oilfish. There are two sorts of oil fish called Ruvettus pretiosus and Lepidocybirium flavobrunneum involved in Percifomes order and Gempylidae class. 16S DNA gene region in mitochondria was selected to design the specific primers. For design species-specific primer, the theoretical experiment were performed for the sequences of R. pretiosus, L. flavobrunneum, Thunnus thynnus, Thunnus albacores, Makaira mitsukurii and Xiphias gladius, registered at the Gene bank from the National Centre for Biotechnology Information, using BioEdit 7.0.9.0. program. Through the analysis of the result from experiments, it was possible to design the 4 kinds of primers to distinguish R. pretiosus and L. flavobrunneum. As a comparison group, 3 kinds of tuna and 4 kinds of billfishes were selected and experimental verification was performed. As a result, for R. pretiosus and L. flavobrunneum, R.P-16S-006-F/R.P-16S-008-R and L.F-16S-004-F/L.F-16S-006-R primers were selected eventually and PCR condition was established. In addition, 178bp and 238bp of PCR products were confirmed from the established condition and non-specific band was not amplified among similar species. Therefore, the species-specific primers developed in this study would be very useful and used in various ways such as internet shopping mall and illegal distributions with fast and scientific results.

Comparison of Association Rule Learning and Subgroup Discovery for Mining Traffic Accident Data (교통사고 데이터의 마이닝을 위한 연관규칙 학습기법과 서브그룹 발견기법의 비교)

  • Kim, Jeongmin;Ryu, Kwang Ryel
    • Journal of Intelligence and Information Systems
    • /
    • v.21 no.4
    • /
    • pp.1-16
    • /
    • 2015
  • Traffic accident is one of the major cause of death worldwide for the last several decades. According to the statistics of world health organization, approximately 1.24 million deaths occurred on the world's roads in 2010. In order to reduce future traffic accident, multipronged approaches have been adopted including traffic regulations, injury-reducing technologies, driving training program and so on. Records on traffic accidents are generated and maintained for this purpose. To make these records meaningful and effective, it is necessary to analyze relationship between traffic accident and related factors including vehicle design, road design, weather, driver behavior etc. Insight derived from these analysis can be used for accident prevention approaches. Traffic accident data mining is an activity to find useful knowledges about such relationship that is not well-known and user may interested in it. Many studies about mining accident data have been reported over the past two decades. Most of studies mainly focused on predict risk of accident using accident related factors. Supervised learning methods like decision tree, logistic regression, k-nearest neighbor, neural network are used for these prediction. However, derived prediction model from these algorithms are too complex to understand for human itself because the main purpose of these algorithms are prediction, not explanation of the data. Some of studies use unsupervised clustering algorithm to dividing the data into several groups, but derived group itself is still not easy to understand for human, so it is necessary to do some additional analytic works. Rule based learning methods are adequate when we want to derive comprehensive form of knowledge about the target domain. It derives a set of if-then rules that represent relationship between the target feature with other features. Rules are fairly easy for human to understand its meaning therefore it can help provide insight and comprehensible results for human. Association rule learning methods and subgroup discovery methods are representing rule based learning methods for descriptive task. These two algorithms have been used in a wide range of area from transaction analysis, accident data analysis, detection of statistically significant patient risk groups, discovering key person in social communities and so on. We use both the association rule learning method and the subgroup discovery method to discover useful patterns from a traffic accident dataset consisting of many features including profile of driver, location of accident, types of accident, information of vehicle, violation of regulation and so on. The association rule learning method, which is one of the unsupervised learning methods, searches for frequent item sets from the data and translates them into rules. In contrast, the subgroup discovery method is a kind of supervised learning method that discovers rules of user specified concepts satisfying certain degree of generality and unusualness. Depending on what aspect of the data we are focusing our attention to, we may combine different multiple relevant features of interest to make a synthetic target feature, and give it to the rule learning algorithms. After a set of rules is derived, some postprocessing steps are taken to make the ruleset more compact and easier to understand by removing some uninteresting or redundant rules. We conducted a set of experiments of mining our traffic accident data in both unsupervised mode and supervised mode for comparison of these rule based learning algorithms. Experiments with the traffic accident data reveals that the association rule learning, in its pure unsupervised mode, can discover some hidden relationship among the features. Under supervised learning setting with combinatorial target feature, however, the subgroup discovery method finds good rules much more easily than the association rule learning method that requires a lot of efforts to tune the parameters.

Cortical Dysplasia: Tc-99m ECD SPECT Findings and Comparative Study with MRI according to Pathologic Grading (뇌피질 이형성증: Tc-99m ECD SPECT 소견과 병리적 등급에 따른 MRI와 비교 연구)

  • Park, Soon-Ah;Lim, Seok-Tae;Sohn, Myung-Hee;Chung, Gyung-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.23-32
    • /
    • 2001
  • Purpose: Cortical dysplasia (CD) designates a diverse group of malformations resulting from one or more abnormalities in the development of the cerebral cortex. We investigated the findings of interictal SPECT and the diagnostic usefulness of interical and ictal SFECT according to pathological grading (PG) in comparison with MRI. Materials and Methods: This study included 16 patients (M:F=9:7, age: $19.9{\pm}11.8$ yrs) with pathologically proven CD. Tc-99m ECD SPECT was performed in all patients: interictal 11, interictal and ictal 3, ictal 2. MRI were obtained in all patients and image analysis was done blindly as to the result of SPECT. Pathologic findings of CD were classified into grade 1 G1, dyslamination), grade 2 (G2, dysplastic neurons) and grade 3 (G3, balloon cells). We compared SFECT with MRI in lesions-to-lesions and analyzed the result according to PG. Results: In SFECT and MRI. 38 and 27 lesions were visually recognized. In 14 interictal SPECT, variable findings in 35 lesions were demonstrated: 25 were hypoperfusion, 7 hyperperfusion, 2 heterotopic perfusion in the white matter. By comparison between two studios, missed lesions were founded: SPECT were 1 lesion, MRI 12. Review of missed 12 lesions of MRI were followed according to PG: G1 patients were 16.7% (4/19), G2 40.0% (6/15), and G3 50% (2/4). Conclusion: Interictal SFECT in CD showed variable findings such as hypoperfusion, hyperperfusion or heterotopic perfusion. However, for detection of missed CD on MRI, SFECT may help to detect a functional abnormality of the lesion with high PG.

  • PDF

Nutritional and Microbiol Quality Assessment of Chungmukimbab (충무김밥의 영양적 및 미생물적 품질 평가)

  • Choi Jong-Duck;Hwang Young-Suk;Jeoung In-Geon;Lee Da-Jeong;Park Phil-Sook;Park Mi-Yeon
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.3
    • /
    • pp.189-195
    • /
    • 2006
  • This research was designed to evaluate the nutritional an microbiol quality assessment of Chungmukimbab purchased from market in Tongyeoung area. Contents of calories, calcium, iron, thiamin and riboflavin in ordinary kimbab and Chungmukimbab were lower than the recommended levels of Korean adult men. So, We suggested that a fruit, beverage and ffod stuff were supplemented to maintain nutritional balance. Total aerobic bacteria and coliform group of just prepared ordinary kimbab and Chungmukimbab samples from market were not significantly different, showing approximately $5.50{\pm}0.38 log_{10} CFU/g,\;2.10{\pm}0.47log_{10}MPN/100g$ in ordinary kimbab, $5.61{\pm}0.42log_{10}CFU/g,\;1.75{\pm}0.34 log_{10} MPN/100g$ in Chungmukimbab, respectively. Total aerobic bacteria of law ingredients of chungmukimbab sample were 3 to $4 log_{10}CFU/g$ in kimbab, seasoning squid and radish roots kimchi, 4 to $5 log_{10}CFU/g$ in boiled fish paste. The coliform groups were 1 to $2 log_{10}$ MPN/100 g in kimbab, seasoning squid and radish roots kimchi, 2 to $3 log_{10}$ MPN/100g in boiled fish paste. Detection rate of E. coli and Staphylococcus aureus counts were 10.0, 12.5% in Chungmu-kimbab, 15.0, 10.0% in seasoning squid, 0, 10.0% in radish roots kimchi respectively, not detected in boiled fish paste samples. During storage at $15^{\circ}C$ for 24 hours, total aerobic counts and coliform groups in ordinary kimbab and Chungmukimbab were increased by the 1.94, $0.97log_{10}CFU/g$, 0.60, 0.72 log10 MPN/100g respectively. Total aerobic counts of Chungmukimbab ingredients increased $0.83{\sim}l.33 log_{10}CFU/g$ at different time

Evaluation of Efficacy and Development of Predictive Model of Sanitizers and Disinfectants on Reduction of Microorganisms on Food Contact Surfaces (스테인리스 스틸 식품기구 표면에 사용되는 주요 살균소독제의 살균력 평가 및 살균예측모델 개발)

  • Lee, Yu-Si;Ha, Sang-Do;Kim, Dong-Ho;Park, Joon-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.3
    • /
    • pp.203-208
    • /
    • 2011
  • This study was to evaluate the efficacy of sanitizer concentrations and treatment time against two major toad-borne pathogenic microorganisms such as Escherichia coli and Staphylococcus aureus on a stainless steel surface. As a result, stainless steel, treated with 100 ppm of chlorine showed reduction of E. coli(1.56, 1.49, 1.95 log cfu/25 $cm^2$) and S. aureus(0.49, 0.88, 1.27 log cfu/25 $cm^2$) after 0, 5 and 10 min, but none was not detected in treatment with 200 ppm. The population of E. coli(0.73, 0.90, 1.55 log cfu/25 $cm^2$) and S. aureus(0.37, 1.00, 1.45 log cfu/25 $cm^2$) reduced in 35.5% ethanol treated group, but none was not detected in treatment with 70%. The population was reduced E coli(0.28, 0.64, 1.07 cfu/25 $cm^2$) and S. aureus(0.53, 0.87, 0.99 log cfu/25 $cm^2$) by treatment with 45.5 ppm of hydrogen peroxide, but none was not detected in treatment with 91 ppm. Quarternary ammonium compound with 100 ppm was reduced E. coli(0.82, 1.62, 1.71 log cfu/25 $cm^2$) and S. aureus(0.46, 0.93, 1.38 log cfu/25 $cm^2$), but none was not detected in treatment with 200 ppm. Predictive models of sterilization for all 4 disinfectants were suitable to use with $r^2$ value of higher than 0.94. These models may be of use to food services and manufacture of safe products by controlling E. coli and S. aureus without the need for further detection of the organisms.

Evaluation of an Automated Liquid-Handling System with Fixed Pipetting Tips in Radioimmunoassay (고정용 팁을 사용하는 Automated Liquid-Handling System의 RIA적용의 평가)

  • Shin, Sun-Young;Kim, Hee-Sun;Lee, Hyun-Ju;Jang, Hyun-Young;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.190-196
    • /
    • 2010
  • Purpose: This study was undertaken to investigate the feasibility of using automated liquid-handling systems equipped with reusable fixed tips in Radioimmunoassays and to demonstrate that the use of an automated pipetting instrument can decrease in the typical daily workload. Materials and Methods: The precisions of the automated pipettor and the manual pipettor were determined gravimetrically (n=30). A total of 30 specimens for HBs Ag were repeatedly pipetted (three replicates) with the automated pipettor and then retested. PSA samples were simultaneously pipetted with either the automated pipettor or the manual pipettor and then analyzed (n=40). Sample carryover test assessed for CA19-9, AFP and HCG when the automated pipettor was used. Pipetting speed of the automated pipettor and the manual pipettor were compared by evaluation of each workload. Results: The precisions coefficients of variation (CV) were 2.1% for the automated pipettor and 1.6% for manual pipettor. The mean cpm and CV for each group of replicates were 41,203 cpm and 3.7% for HBs Ag positive specimens, and 99 cpm and 7.9% for HBs Ag negative specimens, respectively. PSA results showed no significant differences between automated pipettor and manual pipettor (p=0.15, r=0.999). Carryover for CA19-9, AFP and HCG analytes was <0.1 ppm or below the assay limit of detection. Pipetting speed was significantly improved by using the automated instrument. Conclusion: There was no evidence that the use of an automated pipettor adversely affected any of the performance characteristics of the assay. Indeed, routine use of the Tecan automated pipettor has resulted in a decrease in the typical daily workload.

  • PDF

Effect of Bovine Somatotropin (bST) Treatment on Embryo Recovery and Pregnancy Rate in Hanwoo (한우에서 bST 처리가 수정란 회수 및 수태율에 미치는 영향)

  • Jung, S. H.;Lee, J. W.;Son, B. H.;Go, J. S.;Mun, M.;Cho, S. S.;Choi, S. B.;Son, S. G.;Jeong, G. I.;Bae, I. H.;Cho, S. G.;Kong, I. K.
    • Journal of Embryo Transfer
    • /
    • v.17 no.1
    • /
    • pp.79-85
    • /
    • 2002
  • The purpose of this study was to determine the effect of bST treatment on embryo recovery and pregnancy rate following embryo transfer. Donor cows were superovulated with Folltropin-V and PGF$_2$$\alpha$ combination method and then inseminated with frozen semen 3 times 12 hrs interval. Donor and recipient cows were assigned to control and bST group, of which was given a single injection of bST (500 mg, im) at insemination or estrus detection. Embryo collection of superovulated cows were flushed nonsurgical method at 7 to 8 days after artificial insemination. The percentare and Mean$\pm$S.E. of transferable embryo was not significantly different between control and bST treatment (72.8%/5.9$\pm$4.5 vs. 83.7%15.1 $\pm$ 1.6). The percentage and Mean$\pm$S.E. of transferable embryo in non-summer season was significantly higher than in summer (81.8%/5.4$\pm$2.1 vs. 68.7%14.774.6; P<0.05). The pregnancy rate after embryo transfer in bST treatment was significantly higher than in control (64.0 vs. 47.1%; P<0.05). There was no significant difference in pregnancy rate between summer and non-summer (51.6 vs. 61.5%; P>0.05). The results indicated that InST treatment in recipient cows could improve the efficiency of transferable embryo production and pregnancy rate after embryo transfer, and non-summer season may be better far superovulation treatment and embryo transfer.

Thallium-201 SPECT in the Evaluation of Postoperative Tumor Recurrence on the Chest Wall in Lung Cancer (폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성)

  • Ryu, Young-Hoon;Kim, Hyung-Jung;Ahn, Chul-Min;Kim, Se-Kyu;Paik, Hyo-Chae;Lee, Doo-Yun;Chung, Kyung-Young;Yune, Min-Jin;Park, Sang-Jung;Moon, Sung-Wook;Kim, Sang-Jin;Lee, Jong-Doo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.542-549
    • /
    • 2002
  • Purpose : The purpose of our study was to assess the usefulness of the Tl-201 SPECT for the detection of the postoperative tumor recurrence on chest wall. Methods: 28 patients including 14 with suspected recurrence of tumor in the chest wall on postoperative chest cr scan, 10 with postoperative pleural effusion which proved benign on radiologic, cytologic and laboratory findings, and 4 with chronic tuberculous empyema as control group were included. All patients underwent SPECT 30 minutes and 4 hours after intravenous injection of 111MBq of Tl-201. Tumor uptake was visually graded by two interpreters and scored as follows : no uptake:0, similar to contralateral lung: 1, higher than contralateral lung but less than heart:2 and similar to heart:3. Results : Markedly increased (grade 3 or 2) Tl-201 uptake was noted in patients with suspected recurrence of tumor in the chest wall (13/14) whereas no (8/10) or minimal (2/10) uptake along the collapsed lung in patients with postoperative benign pleural effusion. In two patients, Tl-201 SPECT revealed additional recurrent tumor mass lesions that were barely perceptible on chest cr scan. Patients with chronic tuberculous empyema showed relatively smoothly marginated increased uptake along the chest wall 4/4), but lesser in degree (grade 1 or 2), when compared to recurrent tumor uptake. Conclusion : Tl-201 lung SPECT seems to be useful to detect postoperative tumor recurrence on chest wall and to differentiate malignant from benign pleural effusion and may provide additional information to the morphologic data obtained by CT.