• Title/Summary/Keyword: groundwater pumping

Search Result 322, Processing Time 0.037 seconds

Groundwater Recharge and Discharge in the Urban-rural Composite Area (도농복합지역 지하수 함양과 배출에 대한 연구)

  • Lee, Byung-Sun;Hong, Sung-Woo;Kang, Hee-Jun;Lee, Ji-Seong;Yun, Seong-Taek;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.37-46
    • /
    • 2012
  • This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subsequently, the recharge amounts were determined to be $13,253{\times}10^3m^3/yr$. Leakage amounts from water-supply and sewage system were estimated to be $3,218{\times}10^3$ and $5,696{\times}10^3m^3/yr$, respectively. On the whole, a total of the recharge amounts was $22,167{\times}10^3m^3/yr$, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be $382{\times}10^3$ and $1,323{\times}10^3m^3/yr$, respectively. Occurrence of groundwater infiltration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as $714{\times}10^3m^3/yr$. Overall, a total of the discharge amounts was determined to be $2,419{\times}10^3m^3/yr$, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.

Quantitative Assessment of Coastal Groundwater Vulnerability to Seawater Intrusion using Density-dependent Groundwater Flow Model (분산형 해수침투 모델을 이용한 양적 지표 기반의 해안지하수 취약성 평가연구)

  • Chang, Sun Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.95-105
    • /
    • 2021
  • Extensive groundwater abstraction has been recognized as one of the major challenges in management of coastal groundwater. The purpose of this study was to assess potential changes of groundwater distribution of northeastern Jeju Island over 10-year duration, where brackish water have been actively developed. To quantitatively estimate the coastal groundwater resources, numerical simulations using three-dimensional finite-difference density-dependent flow models were performed to describe spatial distribution of the groundwater in the aquifer under various pumping and recharge scenarios. The simulation results showed different spatial distribution of freshwater, brackish, and saline groundwater at varying seawater concentration from 10 to 90%. Volumetric analysis was also performed using three-dimensional concentration distribution of groundwater to calculate the volume of fresh, brackish, and saline groundwater below sea level. Based on the volumetric analysis, a quantitative analysis of future seawater intrusion vulnerability was performed using the volume-based vulnerability index adopted from the existing analytical approaches. The result showed that decrease in recharge can exacerbate vulnerability of coastal groundwater resources by inducing broader saline area as well as increasing brackish water volume of unconfined aquifers.

FEFLOW를 이용한 천부지열 활용 예측 모델링

  • 심병완;송윤호;김형찬
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.399-402
    • /
    • 2004
  • An aquifer thermal energy storage (ATES) model is simulated by FEFLOW according to the scenario of heat pump operation in two layered confining aquifer. The scenario is consisted of 4 steps: 90 days pumping (west well) and waste water injection (east well: 35 $^{\circ}C$), 90 day s stop, 90days pumping (east well) and waste water injection (west well: 5 $^{\circ}C$), and 95 days stop. The injection of the waste water is limited in the second layer and the first layer is aquitard. The temperature distribution at the surface shows low difference with reference temperature and opposit aspect with that of the second layer because the thermal transition through the first layer is very slow. Even though the simulated thermal transition in the aquifer system have a difference with real ATES system, optimal design and operate system can be developed with field tests and operational experience.

  • PDF

창원시 대산면 강변충적층의 지하수위, 하천수위, 강수량의 관련성 연구

  • 정재열;함세영;김형수;차용훈;장성
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.447-450
    • /
    • 2004
  • This study was conducted to characterize groundwater and river-water fluctuations at a riverbank filtration site in Daesan-myeon adjacent to the Nakdong River, using time series analysis. Water levels from six observation wells from January 2003 to October 2003 were measured. The autocorrelation analysis indicates that the wells are divided into three groups: group 1 represents strong linearity and memory, group 2 intermediate linearity and memory, and group 3 weak linearity and memory. The analysis indicates that groundwater levels in different monitoring wells vary in response to river-water levels, groundwater withdrawal and seasonal rainfall. Cross-correlation was also divided into three groups. Group 1 shows the highest cross-correlation function (0.49 - 0.54) for a lag time of 0 hours, group 2 intermediate cross-correlation function (0.34 - 0.45), and group 3 the lowest cross-correlation function (0.23 - 0.25). Different cross-correlation functions among the 3 groups are interpreted as an effect of tile distance from the river to the pumping wells.

  • PDF

Environmental Change of Groundwater due to Urbanization (도시화(都市化)에 의한 지하수환경(地下水環境)의 변화(變化))

  • KIM, Su Won;BAE, Sang Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.1
    • /
    • pp.69-77
    • /
    • 1996
  • To evaluate the change of the groundwater flow and the water table response resulting from urbanization, two cases of the transient three-dimensional numerical simulations were performed. Variations of the groundwater flow system caused by withdrawals were analyzed. Two cases of infiltration rates were applied in this study to verify the water table changes. One is the rate under the circumstance during 1994 and the other is the revised rate. The numerical results from this study indicated that groundwater flow was influenced by human impacts. Groundwater flow has been concentrated to Taegu Textile Complex area where had large amount of pumping. Water table so far decreased -2.76m a year due to withdrawals. Water tables of many points were increased more than 30cm when the surface was reformed by infiltrating the rainfall. It was appeared that the improvement of surface to recharge the precipitation was very important to preserve and manage for the groundwater.

  • PDF

The Effect of Soil Permeability and Pumping Rate on Performance of Two-well Geothermal Heat Pump System (지반 투수계수와 양수량 조건이 복수정 지열 히트펌프 시스템의 성능에 미치는 영향)

  • Cho, Jeong-Heum;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.28-34
    • /
    • 2015
  • The groundwater heat pump (GWHP) systems have great potential for heating-cooling system which use annual constant groundwater temperature for heat source. Generally, the performance of GWHP system significantly depends on the geological and hydraulic properties such as hydraulic conductivity, thermal conductivity, soil condition so on. Therefore, in order to use GWHP systems efficiently, it is necessary to analyze the effect of design factors on the system performance. However, there are a few researches on the optimum design method for the open-loop geothermal system. In this research, the design factor in the open-loop geothermal system was analyzed quantitatively for the optimal design method by using numerical simulation. As a result, it was found that the temperature change of heat source depends on the design factor.

Research for a cases of overseas constructions and domestic tentative execution about high vacuum dewatering and consolidation/dehydration by Super Well point method (슈퍼웰포인트공법에 의한 고진공배수 압밀탈수에 대한 시공사례)

  • Shin, Chang-Beom;Kim, Dae-Hwal;Takahashi, Shigeyoshi;Lee, Kwang-Yeol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.581-590
    • /
    • 2008
  • A SWP method is a revolutionary dewatering method. The conventional dewatering method, deep-well method, had ever occurred a civil appeal caused by the well depletion in compliance with the reduction of the groundwater level over a wider area considerably by the deep-well pumping from homogeneous sand-layer ground for a dry-work, while pump groung excavation working in Sendai city, Japan 10 years ago. it'd developed with the problematic proposal to find the new method which can lower the groundwater level only within the sheet pile without any reduction of groundwater outside of the sheet pile and until currently steady improvement came. It's been confirmed with plenty of executional results that there was almost no decreasing of water-level from surroundings, over so many construction-sites including vertical shafts which completely does not enter into non-water permeable layer and pumping ground etc. The SWP method in this time has been introducing initially and carried into a the execution tentatively at a construction-site and made a various result get through the execution.

  • PDF

Sustainability of freshwater lens in small islands under climate change and increasing population

  • Babu, Roshina;Park, Namsik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.145-145
    • /
    • 2019
  • Groundwater and rainwater are the only sources of freshwater in small islands as many islands lack surface water sources. Groundwater occurring in the form of freshwater lens floating on denser seawater is highly dependent on natural recharge from rainfall. A sharp interface numerical model for regional and well scale modeling is selected to assess the sustainability of freshwater lens in the island of Tongatapu. In this study, 29 downscaled General Circulation Model(GCM) predictions are input to the recharge model based on water balance modelling. Three GCM predictions which represent wet, dry and medium conditions are selected for use in the groundwater flow model. Total freshwater volume and number of saltwater intruded wells are simulated under various climate scenarios with GCM predicted rainfall pattern, sea level rise and pumping. Simulations indicate that the sustainability of the freshwater lens is threatened by the frequent droughts which are predicted under all scenarios of recharge. The natural depletion of the lens during droughts and increase in water demands, leads to saltwater upconing under the pumping wells. Implementation of drought management measures is of utmost importance to ensure sustainability of freshwater lens in future.

  • PDF

Groundwater Movement Analysis Using the WINFLOW Model (WINFLOW 모델을 이용한 지하수 유동해석)

  • 최윤영;안승섭;김재광
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.3
    • /
    • pp.103-115
    • /
    • 2003
  • This study examines groundwater movement system analysis and movement forecast algorithm using finite element method. The target is Cheongha-myeon area, Bukgu, Pohang-city which has many difficulties in water supply during drought period. From the comparison of the differences between obtained values by WINFlOW model and observed values, it is thought that groundwater head distribution under steady flow is reflected well at the level of reliability Groundwater movement of study area shows stable pattern from western watershed to eastern coastal area while flow path is dense and steep in the center of the coastal area. The results of particle tracing for each well show a comparatively straight line from the western boundary side to the observation position at the upper area of the well, and are analyzed as it diffuses according to getting closer to the coast at the lower area of the well. The result of effect circle examination attendant on pumping amount in study area shows variation tendency that groundwater head decreases at the side and the lower area more than at the upper area of the well when groundwater flows from west to east(coast). As mentioned above, satisfactory results of groundwater movement analysis using WINFlOW model, two dimensional groundwater movement analysis model, are obtained through the great decrease of physical uncertainty of groundwater movement system.

Application of Groundwater Software for Windows(GWW): An Overview (GWW를 이용한 지하수 자료 관리)

  • 김윤영;이강근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.9-14
    • /
    • 1996
  • GWW was developed by UN(United Nations) in order to manage groundwater data systematically on PC windows. Temporal and spatial data from lab and field tests are stored in a data base. The data base can be displayed graphically by using the GIS (Geographic Information System) technique. Raw data from pumping tests, step-drawdown tests, and chemical analyses can be analysed to characterize the hydrogeologic system. This article demonstrates a GWW application using default database and groundwater data obtained at the Nanjido Landfill site.

  • PDF