• Title/Summary/Keyword: groundwater inflow

Search Result 156, Processing Time 0.022 seconds

Development of the Compressed Packer Grouting Device for Preventing the Inflow of Polluted Groundwater (오염지하수 유입방지를 위한 압축패커 그라우팅 장치 개발)

  • Cho, Heuy-Nam;Choi, Sang-Il
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.433-439
    • /
    • 2009
  • The compressed packer device is designed to improve the underground contamination prevention facilities of ground water wells. As for the device, the installation is simple because of the safety lock device and the compression of the casing are simple the installation is simple. There is no leakage of ground water because the pressure resistance with $4.5\;kg/cm^2$ makes it equipped with the watertightness The single casing is installed and the reaming for grouting is possible with 300 mm excavation so that installation cost can be saved. Silicon rubber is used for the compressed packer so that the extension rate is 590%. In terms of environmental pollution, it is an environmental friendly product which does not contain harmful ingredients such as Pb, Cd, and phenol. below the standard or undetectable level Furthermore, the installation costs are 35 to 62% or lower than the conventional grouting construction method and are 87% or lower than the expansion packer construction method, the new environmental technology No.47 Also, the device is designed to meet the relevant regulations such as Rules on Preserving the Ground Water Quality, The Standard on Jeju Island Ground Water Development and Facility Installation and Management, and The Plan and Guideline on Operating and Managing the Small-Scale Tap Water Facilities of Ministry of Environment and Ministry of Food, Agriculture, Forestry and Fisheries.

A Study on Corrosion Properties of Reinforced Concrete Structures in Subsurface Environment (지중 환경하에서의 철근콘크리트 구조물의 부식 특성 연구)

  • Kwon, Ki-jung;Jung, Haeryong;Park, Joo-Wan
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.79-85
    • /
    • 2016
  • A concrete silo plays an important role in subsurface low- and intermediate-level waste facilities (LILW) by limiting the release of radionuclides from the silo geosphere. However, due to several physical and chemical processes the performance of the concrete structure decreases over time and consequently the concrete loses its effectiveness as a barrier against groundwater inflow and the release of radionuclides. Although a number of processes are responsible for degradation of the silo concrete, it is determined that the main cause is corrosion of the reinforcing steel. Therefore, the time it takes for the silo concrete to fail is calculated based on two factors: the initiation time of corrosion, defined as the time it takes for chloride ions to penetrate through the concrete cover, and the propagation time of corrosion. This paper aims to estimate the time taken for concrete to fail in a LILW disposal facility. Based on the United States Department of Energy (DOE) approach, which indicates that concrete fails completely once 50% of the volume of the reinforcing steel corrodes, the corrosion propagation time is calculated to be 640 years, which is the time it takes for corrosion to penetrate 0.640 cm into the reinforcing steel. In addition to the corrosion propagation time, a diffusion equation is used to calculate the initiation time of corrosion, yielding a time of 1284 years, which post-dates the closure time of the LILW disposal facility if we also consider the 640 years of corrosion propagation. The electrochemical conditions of the passive rebar surface were modified using an acceleration method. This is a useful approach because it can reduce the test time significantly by accelerating the transport of chlorides. Using instrumental analysis, the physicochemical properties of corrosion products were determined, thereby confirming that corrosion occurred, although we did not observe significant cracks in, or expansion of, the concrete. These results are consistent with those of Smartet al., 2006 who reported that corrosion products are easily compressed, meaning that cracks cannot be discerned by eye. Therefore, it is worth noting that rebar corrosion does not strongly influence the hydraulic conductivity of the concrete.

Column Tests for the Design of PRB System using CFW (음식폐기물 탄화재로 충진된 PRB설계법 제안을 위한 컬럼실험)

  • Han, Jung-Geun;Yoon, Won-Il;Jung, Dong-Ho;Kim, Yong-Soo;Lee, Jong-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.35-43
    • /
    • 2011
  • Permeable Reactive Barriers (PRB) method is an economical method that does not require any other methods to be operated once it is installed as it controls of groundwater flow in the barrier, which is inserted a reactive material on the way of pollutant. The major dominant element of PRB is a reactive material in the reactive wall, and such factors as purification efficiency and used time based on the chemical and physical features in between the reactant and pollutant. High purification efficiency can be expected when a rational design that is synthetically considered in features of packing density, operation period, and adsorption reactant of pollutant. A column test was conducted for an application test using CFW as its adsorption reactant in order to remove copper($Cu^{2+}$) in the PRB system. The CFW was used for the reactant and selected inflow speed, density and thickness of PRB as its necessary factors for design of PRB. As a result of the experiment, the removal efficiency decreased as operating time of PRB increased and the efficiency linearly increased upon the length. Therefore, it is confirmed that the thickness of reactive materials in PRB system can be designed using the proposed formula considering purification time and density of CFW.

Thermal Properties of Buffer Material for a High-Level Waste Repository Considering Temperature Variation (고준위폐기물 처분시설 완충재의 온도변화에 따른 열물성)

  • Yoon, Seok;Kim, Geon-Young;Park, Tae-Jin;Lee, Jae-Kwang
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.10
    • /
    • pp.25-31
    • /
    • 2017
  • The buffer is one of the major components of an engineered barrier system (EBS) for the disposal of high-level radioactive waste (HLW). As the buffer is located between a disposal canister and host rock, it is indispensable to assure the disposal safety of high-level radioactive waste. It can restrain the release of radionuclide and protect the canister from the inflow of groundwater. Since high quantity of heat from a disposal canister is released to the surrounding buffer, thermal properties of the buffer are very important parameters for the analysis of the entire disposal safety. Especially, temperature criteria of the compacted bentonite buffer can affect the design of HLW repository facility. Therefore, this paper investigated thermal properties for the Kyungju compacted bentonite buffer which is the only bentonite produced in South Korea. Hot wire method and dual probe method were used to measure thermal conductivity and specific heat capacity of the compacted bentonite buffer according to the temperature variation. Thermal conductivity and specific heat capacity were decreased dramatically when temperature variation was between $22^{\circ}C{\sim}110^{\circ}C$ as degree of saturation decreased according to the temperature variation. However, there was little variation under the high temperature condition at $110^{\circ}C{\sim}150^{\circ}C$.

A Prediction of Specific Heat Capacity for Compacted Bentonite Buffer (압축 벤토나이트 완충재의 비열 추정)

  • Yoon, Seok;Kim, Geon-Young;Baik, Min-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.199-206
    • /
    • 2017
  • A geological repository for the disposal of high-level radioactive waste is generally constructed in host rock at depths of 500~1,000 meters below the ground surface. A geological repository system consists of a disposal canister with packed spent fuel, buffer material, backfill material, and intact rock. The buffer is indispensable to assure the disposal safety of high-level radioactive waste, and it can restrain the release of radionuclides and protect the canister from the inflow of groundwater. Since high temperature in a disposal canister is released to the surrounding buffer material, the thermal properties of the buffer material are very important in determining the entire disposal safety. Even though there have been many studies on thermal conductivity, there have been only few studies that have investigates the specific heat capacity of the bentonite buffer. Therefore, this paper presents a specific heat capacity prediction model for compacted Gyeongju bentonite buffer material, which is a Ca-bentonite produced in Korea. Specific heat capacity of the compacted bentonite buffer was measured using a dual probe method according to various degrees of saturation and dry density. A regression model to predict the specific heat capacity of the compacted bentonite buffer was suggested and fitted using 33 sets of data obtained by the dual probe method.

Nutrient Balance in the Paddy Fields Watershed with a Source of River Water (하천관개지역 광역논에서의 영양물질의 물질수지)

  • Lee, Jeong Beom;Lee, Jae Yong;Li, Si Hong;Jang, Jeong Ryeol;Jang, Ik Geun;Kim, Jin Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.11-19
    • /
    • 2014
  • The objective of this research was to investigate concentration and load of nutrients such as total nitrogen (TN), nitrate nitrogen ($NO_3$-N) total phosphorous (TP), and phosphate phosphorous ($PO_4$-P) in a 23.4-ha paddy fields watershed with river water source. Water samples for irrigation water, drainage water, ponded water and groundwater were collected, and irrigation and drainage water were measured at 5~10 day intervals during normal days and at 2~6 hours intervals during three storm events. The amount of irrigation water in the study area was over 2,000 mm, which is almost identical to that in the area irrigated from a large reservoir but much more than that in the area irrigated from a pumping station. Mean flow-weighted concentrations of TN and TP in irrigation water were 2.8 and 0.15 mg/L, respectively, higher than those in the area irrigated from a large reservoir or a pumping station. The ratios of irrigation load to total inflow load for TN and TP were 88 %, and the ratios of surface outflow load to total outflow load for TN and TP were over 90 %, indicating that total nutrient load may be greatly affected by water management. The nutrient loads per area in the study area were estimated as TN 21.1 kg/ha and TP 1.1 kg/ha. Especially, the TP load per area in the study area was smaller than that in the area irrigated from a large reservoir or a pumping station. This may be because outflow load is not high likely due to sedimentation of particulate P and irrigation water load is high due to high TP concentration in irrigation water and high amount of irrigation water.

Assessment of Agricultural Water Supply Capacity Using MODSIM-DSS Coupled with SWAT (SWAT과 MODSIM-DSS 모형을 연계한 금강유역의 농업용수 공급능력 평가)

  • Ahn, So Ra;Park, Geun Ae;Kim, Seong Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.507-519
    • /
    • 2013
  • This study is to evaluate agricultural water supply capacity in Geum river basin (9,865 $km^2$), one of the 5 big river basin of South Korea using MODSIM-DSS (MODified SIMyld-Decision Support System) model. The model is a generalized river basin decision support system and network flow model developed at Colorado State University designed specifically to meet the growing demands and pressures on river basin management. The model was established by dividing the basin into 14 subbasins and the irrigation facilities viz. agricultural reservoirs, pumping stations, diversions, culverts and groundwater wells were grouped and networked within each subbasin and networked between subbasins including municipal and industrial water supplies. To prepare the inflows to agricultural reservoirs and multipurpose dams, the Soil and Water Assessment Tool (SWAT) was calibrated using 6 years (2005-2010) observed dam inflow and storage data. By MODSIM run for 8 years from 2004 to 2011, the agricultural water shortage had occurred during the drought years of 2006, 2008, and 2009. The agricultural water shortage could be calculated as 282 $10^6m^3$, 286 $10^6m^3$, and 329 $10^6m^3$ respectively.

A Prediction of Thermal Conductivity for Compacted Bentonite Buffer in the High-level Radioactive Waste Repository (고준위폐기물 처분시설의 압축 벤토나이트 완충재의 열전도도 추정)

  • Yoon, Seok;Lee, Min-Soo;Kim, Geon-Young;Lee, Seung-Rae;Kim, Min-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.7
    • /
    • pp.55-64
    • /
    • 2017
  • A geological repository has been considered one of the most adequate options for the disposal of high-level radioactive waste. A geological repository will be constructed in a host rock at a depth of 500~1,000 meters below the ground surface. The geological repository system consists of a disposal canister with packed spent fuel, buffer material, backfill material, and intact rock. The buffer is very important to assure the disposal safety of high-level radioactive waste. It can restrain the release of radionuclide and protect the canister from the inflow of groundwater. High temperature in a disposal canister is released into the surrounding buffer material, and thus the thermal transfer behavior of the buffer material is very important to analyze the entire disposal safety. Therefore, this paper presents a thermal conductivity prediction model for the Kyungju compacted bentonite buffer material which is the only bentonite produced in Korea. Thermal conductivity of Kyungju bentonite was measured using a hot wire method according to various water contents and dry densities. With 39 data obtained by the hot wire method, a regression model to predict the thermal conductivity of Kyungju bentonite was suggested.

A Study on the Analysis of the Relaxation Area and the Improvement Effect of the Ground by Road Subsidence (지하연속벽 배면 도로의 지반침하에 따른 이완영역분석방법과 지반 보강 효과검증에 관한 연구)

  • Lee, Hyoung Kyu;Lee, Yong-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.1
    • /
    • pp.29-41
    • /
    • 2021
  • Although underground works are essential to use underground spaces in urban areas efficiently, various damages caused by constructions have often occurred, making them major social problems. Since 2018, it is stipulated in the Special Act on Underground Safety Management that appropriate construction methods must be used in the design stage to prevent various damage cases. This Special Act includes establishing an area subject to underground safety impact assessment, analysis of ground and geological status, review of effects caused by changes in groundwater, review of ground safety, and establishment of measures to secure underground safety. This study area consists of various strata in order of landfill, sedimentary silt, sedimentary sand, sedimentary gravel, weathering zone, and foundation rock. Also, the slurry wall, a highly rigid underground continuous wall, was chosen as a construction method to consider high water table distribution and minimize the influence of the surroundings in this area. However, ground subsidence occurred on the road nearby in December 2019 due to the inflow of loosening soil to the construction area. Thus, several types of site investigations were conducted to suggest an appropriate analysis method and to find out loosed ground behavior and its area for the subsided site. As a result, new design soil properties were re-calculated, and the reinforcement measures were proposed through analytical verification.

Evaluation of thermal-hydro-mechanical behavior of bentonite buffer under heating-hydration condition at disposal hole (처분공 가열-수화 조건에서 벤토나이트 완충재의 열-수리-역학적 거동 특성 평가)

  • Yohan Cha;Changsoo Lee;Jin-Seop Kim;Minhyeong Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.175-186
    • /
    • 2023
  • The buffer materials in disposal hole are exposed to the decay heat from spent nuclear fuels and groundwater inflow through adjacent rockmass. Since understanding of thermal-hydro-mechanical-chemical (T-H-M-C) interaction in buffer material is crucial for predicting their long-term performance and safety of disposal repository, it is necessary to investigate the heating-hydration characteristics and consequent T-H-M-C behavior of the buffer materials under disposal conditions considering geochemical factors. In response, the Korea Atomic Energy Research Institute developed a laboratory-scale 'Lab.THMC' experiment system, which characterizes the T-H-M behavior of buffer materials under different geochemical conditions by analyzing heating-hydration process and stress changes. This technical report introduces the detail design of the Lab.THMC system, summarizes preliminary experimental results, and outlines future research plans.