주파수 영역에서 봉상전극의 접지임피던스 특성 (Ground ing Impedance Characteristics of Ground Rods in frequency Domain)

  • 이형수;심건보;김경철;최종기;박상만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.248-253
    • /
    • 2005
  • Although DC ground resistance is a good index of grounding performance for grounding electrodes, it does not reflect the grounding performance during transient state. Besides, impulse ground impedance, which is defined by a ratio of the peak value of transient ground potential rise to the peak value of impulse current, cannot be an absolute index due to its dependence on impulse current shape. In this paper, ground impedance of various rod-type ground electrodes has been measured in frequency domain ranging from 1 Hz to hundreds of kHz. Equivalent circuit models of the ground rod have been identified from the measured values of ground impedance in frequency domain.

  • PDF

변전소 옥내화에 따른 접지설계 (Grounding System Design According to Indoor Substation)

  • 최종기;주병수;김문덕;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.905-907
    • /
    • 1996
  • Current design standard of substation grounding systems is primarily concerned with conventional outdoor substations. But in case of 154kV substations in the nation, almost all are indoor-type GIS substations. So there became to be something not proper for application of present design standard to indoor-type substations. In this paper, as a preliminary stage of drawing-up of the grounding system design standard which concerned with in-door-type substions, issues of current design standard are mentioned and directions of improvement are also presented.

  • PDF

전력설비용 접지시스템에 공결점에 따른 과도응답특성 (Transient Response characteristics Associated with the Common Connection Points in Grounding Systems for Electric Power Utilitires)

  • 이복희;이승칠;엄주홍;심판섭
    • 조명전기설비학회논문지
    • /
    • 제13권3호
    • /
    • pp.101-108
    • /
    • 1999
  • 본 논문은 임펄스전류에 대한 전력설비용 접지시스템의 과도응답특성에 대하여 기술하엿으며, 피뢰기 접지도선을 통하여 임펄스전류가 유입될 때, 공결점과 다른 접지도선에 유도되는 전위상승을 측정·분석하였다. 낙뢰서지에 의한 피뢰기의 동작을 모의하기 위하여 뇌임펄스전류를 인가하였으며, 본 실험에서 얻은 임펄스 응답특성의 실험결과는 다음과 같다. 접지전극에 유도되는 전위상승은 접지도선에 유도된 것과는 상당히 달았으며, 다른 독립접지전극에도 높은 전위유도가 발생하였다. 또한 임펄스전류에 의한 접지전극과 접지도선의 전위상승은 공결점의 위치에 따라 현저하게 변하였다. 근방공결한 경우 임펄스전류에 의한 공결점의 전위상승은 원방공결한 경우보다 낮게 나타났다. 피뢰기 접지도선의 전위상승은 근방공결한 경우가 원방공결항 것보다 높게 나타났다. 따라서 전위상승의 측면을 고려하면 근방공결하는 경우가 원방공결하는 것보다 효과적이고, 전력기기의 절연보호 측면에서는 원방공결하는 것이 보다 효과적임을 알았다.

  • PDF

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전시 적정 피뢰기 위치에 관한 연구 (A Study on the Optimal Position of Lightning Arrester on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;장화윤;안천용;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.535-536
    • /
    • 2011
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems and analyzes the optimal position of lightning arrester on joint operation of neutral wire and overhead grounding wire. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as location and current types of lightning stroke. Over voltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

  • PDF

접지그리드의 접지임피던스 측정 기법 (Measurement method of ground impedance for the grounding grid)

  • 이복희;최종혁;최영철;유재덕;백영환;김동성;신희경;유양우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1487_1488
    • /
    • 2009
  • In these days, the common grounding systems are adapted in most large structures. In order to evaluate the performance of grounding system, it is needed to measure ground impedance. Measuring methods of ground impedance for a large scale grounding systems have not been yet presented in detail. In this paper, we analyze earth mutual resistance and mutual coupling of $15{\times}15m$ grounding grid in different arrangements of auxiliary electrode. As a results, the auxiliary electrodes are installed where the error rate due to earth mutual resistance is less than 5%. Also, the potential lead is installed at obtuse angle from the current lead and the overlapped length between potential lead and grounding grid are minimized.

  • PDF

지역필터를 이용한 수변전실 접지저항의 새로운 측정방법 (A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations)

  • 이복희;엄주홍;이승칠;김성원;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

접지그리드의 접지임피던스 측정의 정확도 평가 (Evaluation of the Accuracy of Grounding Impedance Measurement of Grounding Grid)

  • 최종혁;최영철;정동철;김동성;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.146-153
    • /
    • 2009
  • 최근 대형 건축물들은 접지그리드를 기반으로 한 공통접지방식을 채택하고 있다. 이러한 접지시스템의 성능평가는 접지저항만으로 불충분하므로 접지임피던스의 측정이 요구된다. 대형 접지시스템의 접지임피던스에 대한 측정 방법은 IEEE standard 81.2에 기술되었으나 세부적인 평가방법들은 제시되지 못한 상태이다. 본 논문은 15[m]$\times$15[m] 접지그리드에 대하여 수정된 전위강하법에 기반한 접지임피던스의 정확한 측정방법과 보조전극의 위치에 따른 도전유도 및 전자유도에 의한 측정오차를 기술한다. 그 결과 도전유도에 의한 오차는 보조전극의 거리가 늘어날수록 감소하였다. 전자유도에 의한 오차를 배제하기 위해서 전위측정선은 전류측정선과 90도를 이루어야 한다. 전위측정선과 전류측정선이 예각 또는 둔각을 이루었을 때 전자유도전압은 각각 + 또는 -를 나타내었다. 일반적으로 전자유도에 의한 오차는 예각에 비해서 둔각의 경로가 작게 나타났다.

간이 저압 전력계통에서의 계통 접지대책에 관한 연구 (A Study on the Portable and Vehicle-Mounted Generators Grounding of Low-Voltage Systems)

  • 위원석;김정훈;조규덕;류보혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.43-45
    • /
    • 2000
  • In this paper, portable and vehicle-mounted generators grounding methods of low-voltage systems is compared to each other. Ungrouded system is better for the safety operation than solidly grounding system. This paper also determined the magnitude and duration of the permissible body current limit and step voltage for the solidly-grounding and ungrounded system.

  • PDF

전력용변압기 단선 보호용 NGR 성능 개선 (The Improvement of NGR for Power Transformer Open Circuit Protection)

  • Kang, Y.W.;Shim, E.B.;Kwak, J.S.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.83-88
    • /
    • 2004
  • As the electric system is getting larger to meet the increasing demand for electric power, the rating of power apparatus is becoming inevitably higher in its working voltage and larger in its capacity. According to KEPCO reports, power transformers in the KEPCO system have undergone troubles such as winding short insulation breakdowns every year since 1981. the cause of this troubles were high one line grounding fault currents in KEPCO systems that had direct grounding systems. KEPCO has installed the NGR(neutral grounding reactor) to lower this fault current and reduced winding short insulation breakdowns in power transformers. But when a circuit breaker opened a no load bus, some trips of circuit breakers for protecting transformer have occurred by mal-operation of 59GT(overvoltage ground relay) that detect disconnection of NGR. Therefore, in this paper, we analyzed the cause and examined the effect of time delav circuit to prevent wrong operation of 59GT.

  • PDF

Characteristic Mode Analysis and New Ground Approach At a Heat-sink for Reducing EM Radiation

  • Son, Seung-Han;Ahn, Chang-Hoi
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.379-386
    • /
    • 2018
  • A heat-sink has been widely used to cool down the heat generated from an electronic device, but it can bring unwanted electromagnetic radiation which may cause EMI problems. We propose a systematic method to reduce the electromagnetic radiation by using the multiple grounding technique based on the grounding criteria and the theory of characteristic mode analysis. Our proposed method provides the insight to find the specific grounding positions which can be effectively reduced the radiation from the heat-sink. Numerical experiments are accomplished to validate this approach.