• Title/Summary/Keyword: ground test

Search Result 4,189, Processing Time 0.028 seconds

A Case Study on the Plan for Settlement Restraint by CGS (CGS 공법에 의한 지반침하억제 사례연구)

  • 천병식;여유현;김우종;황성식;김우철
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.611-618
    • /
    • 2002
  • In this study the CGS as an injection method by low slump mortar was performed the pilot test to confirm the applicability of this method and the effectiveness of settlement restraint. From the results, there has been concluded the construction control standard such as an institutional diameter, space, depth, injection materials, Infection pressure etc. Also, there has been estimated the ground improvement effectiveness which has resulted from the field investigation and consolidation test etc. From the results, in the adjacent ground the CGS, generally, has been confirmed to in-crease ground strength to improve the consolidation characteristic obtained from the field investigation and consolidation test. Especially, the CGS which performed the larger stiffness to the ground has been concluded that the settlement restraint to the ground complicates the ground effect which Increases the bearing capacity and stress assignment. So, the CGS can be considered as an effective method to increase the bearing capacity as well as the settlement restraint of soft ground.

  • PDF

Evaluation of Ground Improvement on Sands at Yongjong Island Geotechnical Experimental Site (영종도 지반공학 야외시험장에서의 사질토지반 개량효과 평가)

  • 김동수;박형춘;김영웅;김수일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.439-446
    • /
    • 1999
  • In situ experimental studies were Performed at Yongjong Island Geotechnical Experimental Site to evaluate the ground densification on sand deposited. Standard penetration test, cone penetration test, and SASW test were performed and soil profiles and quality of ground improvements were evaluated. The feasibility of applying SASW method were verified by comparing test results. The evaluation technique of in-situ density using SASW and resonant column tests was proposed, and the reliability of proposed method was verified by performing case studies.

  • PDF

Analysis of the Ground Impedance of Ground Grids Combined with the Carbon Ground Electrodes (탄소접지극이 병설된 접지그리드의 접지임피던스의 해석)

  • Lee, Bok-Hee;Um, Sang-Hyun;Kim, You-Ha;Lee, Kang-Soo;Jeon, Byung-Wook;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.36-42
    • /
    • 2013
  • This paper deals with the frequency-dependent ground impedance of ground grids combined with the carbon ground electrodes. Ground grids are generally valid for multipurpose grounding systems as well as lightning protection systems. The carbon ground electrodes may be supplementarily used to reduce the high frequency ground impedance and to improve the transient response to surge currents. The frequency-dependent ground impedances of ground grids combined with or without the carbon ground electrodes were measured and their simulations with due regard to frequency-dependent soil resistivity were implemented by using EMTP program and Matlab modeling. As a consequence, the ground impedance of ground grids combined with the carbon ground electrodes is significantly reduced when the test current is injected at the terminal of the carbon ground electrode. The measured and simulated data for the test ground grids fairly agree with each other. It was found that the proposed method of simulating the frequency-dependent ground impedance is distinguished. The simulation techniques of predicting accurately the ground impedances without actual measurements can be used in the design of grounding systems based on ground grids and the carbon ground electrodes.

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

Effect of Input Soil Properties for Round Robin Test on Ground Response Analysis (지반 응답 해석 Round Robin Test의 입력 지반 물성에 따른 지반 응답 특성 영향 고찰)

  • Kim, Bong-Soo;Lee, Sei-Hyun;Choo, Yun-Wook;Park, Sung-Sik;Kim, Dong-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.305-316
    • /
    • 2007
  • Free field ground motion during earthquake is significantly affected by the local soil conditions and it is essential for the seismic design to perform the site specific ground response analysis. So, Round Robin Test (RRT) on ground response analysis was performed for three sites in Korea. A total of 12 teams presented the results of ground response analysis with used input soil properties based on own judgement. In this paper, the results of one dimensional equivalent linear analysis presented by 11 teams were compared to evaluate the effect of input soil properties on ground response analysis. Additionally, 4 influence factors on ground response analysis, that is shear wave velocity of soil layer, nonlinear dynamic deformational characteristics, bedrock depth and bedrock velocity were studied for assumed simple soil conditions.

  • PDF

A Comparative Study of Various Approaches of Seismic Ground Response Analyses by Using a Round Robin Test Methodology (Round Robin Test 기법을 통한 다양한 지반응답해석 접근법 비교 연구)

  • Kim, Jin-Man;Park, Yo-Hwan;Kim, Ki-Seog;Park, Du-Hee;Sun, Chang-Guk;Kim, Sung-Ryul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.259-265
    • /
    • 2007
  • The technical committee of Soil Dynamics and Geotechnical Earthquake Engineering of Korean Geotechnical Socity has conducted Round Robin Test(RRT) on seismic ground response analyses in 2007. Total 14 participating teams were given exact same soil information of three sites and three input ground motions including two recorded ground motions and one synthetic ground motion. Each team selected its own analysis method and approaches to perform ground response analyses. There were equivalent linear, nonlinear total stress, and nonlinear effective stress approaches, which could be selected. The results from RRT were systematically analyzed and dispersion and variation due to analysis methods, input ground motions, shear velocity profiles, shear modulus reduction curves, damping curves, and other input data are reported by the companion papers.

  • PDF

Evaluation of Ground Response Dispersion Caused by the Difference of Input Ground Motions (입력지진파 차이로 인한 지반응답 분산도 평가 연구)

  • Kim, Jin-Man;Ryu, Jeong-Ho;Kweon, Gi-Chul;Sim, Jae-Ho;Kim, Jae-Kyoung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.293-304
    • /
    • 2007
  • In 2007, Round Robin Test (RRT) on ground response analyses has been conducted by the technical committee of Soil Dynamics and Geotechnical Earthquake Engineering of Korean Geotechnical Society. Total 14 teams have reported 16 different results. This paper discusses the evaluation of ground response dispersion caused by the difference of input ground motions. In order to determine the characteristics of ground response, this study analysed the peak ground acceleration, predominant period, and response spectrum of reported ground surface motions. The results suggest that ground response dispersion due to the difference of input ground motions can be significant.

  • PDF

A Study on Shear Strength of Composite Ground with Triaxial Test (삼축압축시험을 통한 복합지반의 전단강도에 관한 연구)

  • 신희범;이상익;박용원;김병일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.569-576
    • /
    • 2000
  • This study performs a series of Triaxial Compression Test for clay-sand composite specimens changing area replacement ratio. Purpose of the test is to conform the propriety of weighted average method in estimating shear strength of the composite ground. The test results show that measured values of shear strength of composite specimens are larger by 20∼30% than those from estimation using the current weighted average method. It is thought that the differences are from pseudo-overconsolidation behavior of composite specimens.

  • PDF

Imprementation of Real Time HILS System for Ground Test of Underwater Vehicle (수중 운동체의 육상 모의시험을 위한 실시간 HILS 시스템 구현)

  • Park, Yeong-Il;Choi, Young-Chul;Cho, Kyu-Kab;Lee, Man-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.2
    • /
    • pp.282-289
    • /
    • 1999
  • To minimize a real world test of underwater guided vehicle, it is necessary to perform a test on ground by using closed loop test techniques. This paper describes implementation of HILS(Hardware In the Loop Simulation) system for ground test and test methodologies for performance evaluation of a guided weapon. HILS system uses a real time distributed computer and a real time processing technique. Ground test results of underwater vehicle are presented for moving and stationary targets by using HILS system.

  • PDF

A Study on Benefits of Ground Operational Test using ADS-B in Tae-An Airport (지상운영시험을 통한 ADS-B 효과에 관한 연구)

  • Hong, G.Y.;Oh, K.R.;Kim, D.H.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.2
    • /
    • pp.25-31
    • /
    • 2007
  • The ADS-B test is a program that is examining the use of ADS-B, especially CDTI for aircraft surveillance in Korea. The ADS-B project is to provide operational benefits to Air Traffic Controllers in the selected area and provide first operational experience of ADS-B in ATCS environment of South Korea. For these objectives, the ground station has installed in Tae-An airport, Participation in the Ground Test has been limited to 4 Aircraft of Hanseo University which are installed ADS-B equipment. Ground test is a test that is examining on the movement area of Tae-An Airport on the assumption that the visibility is below weather minia of the airport. This test have been experimented as pre-arranged scenarios. In view of the results achieved, it has shown that the volume of voice communication between controller and pilot are remarkably reduced. Additionally, as both pilots and air traffic controllers are able to see the positions of traffic in the vicinity of the aircraft, the test has demonstrated that it is possible for ADS-B not only to decline the controller's workload, but also to enhance pilot situational awareness in the near future.

  • PDF