• Title/Summary/Keyword: ground response curve

Search Result 88, Processing Time 0.023 seconds

Assessment of nonlinear static and incremental dynamic analyses for RC structures

  • Oncu, Mehmet Emin;Yon, Merve Sahin
    • Computers and Concrete
    • /
    • v.18 no.6
    • /
    • pp.1195-1211
    • /
    • 2016
  • In this study, seismic behaviour of reinforced concrete buildings using the pushover and incremental dynamic analysis method was investigated. A numerical study was performed for a reinforced concrete frame building. Pushover analysis according to uniform and triangular load shapes and incremental dynamic analyses were performed for selected building. For the nonlinear analysis, three ground motion records were selected to ensure compatibility with the design spectrum defined in the Turkish Seismic Code. The maximum response, dynamic pushover curve, capacity curves, interstorey drifts and moment rotation curves for various element ends of the selected building were obtained. Results were compared each other and good correlation was obtained between the dynamic analyses envelope with static pushover curves for the building.

Improved FOM (Figure of Merit) Performance Characteristics of a Linear Array Underwater Acoustic Transducer with a Gradual Wedge-shaped Tail Mass (완만한 쐐기형 Tail Mass를 갖는 선형배열 수중음향변환기의 FOM (Figure of Merit) 성능특성 개선)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.6
    • /
    • pp.1036-1044
    • /
    • 2021
  • A linear array acoustic transducer with 12 tonpilz elements mounted independently on a gradual wedge-shaped tail mass was fabricated, tested and analyzed. The compensated transducer, which is modified by including a series inductance of 137 µH in the developed linear array transducer, attained improved figure of merit (FOM) performance characteristics compared with the uncompensated transducer. The four resonant frequency bands were identified from the measured FOM curve. The FOM response patterns over the frequency ranges of 31 to 40 kHz and 50 to 60 kHz were relatively uniform, whereas sharp resonance peaks were observed at around 73 kHz and 84 kHz. These results indicate that the developed linear array transducer can be used as an enhanced broadband transducer of echo sounder, and the operating frequency can be selected for more effective echo surveys in the fishing ground.

Determination of an Underground Seawater Flow Using a TEM Decay Curve (TEM감쇠곡선을 이용한 해수의 지하 유동현상 파악)

  • 황학수;문창규;이상규;이태섭
    • Economic and Environmental Geology
    • /
    • v.34 no.5
    • /
    • pp.499-506
    • /
    • 2001
  • The geophysical monitoring technique using the high resolution time-domain electromagnetic (TEM) method with a coincident loop away was applied for determination of an underground seawater flow in the coastal areas. In comparison of the TEM monitoring to direct current (DC) resistivity monitoring, the TEM response to the under ground seawater flow is less sensitive than the DC resistivity response. However, the TEM monitoring is more effective in terms of measuring time, survey expense, and real-time data processing than the DC monitoring thor evaluating the spatial distribution of the fresh water-seawater transition zone in a regional area.

  • PDF

Liquifaction Evaluation of Saemangeum Area and the Considerations of Liquifaction Effect to the Foundations of Structures in Near Future (I) (새만금 지역의 액상화 평가 및 향후 구조물 기초 설계시 액상화 영향의 고려방안 (I))

  • Kim, You-Seong;Ko, Hyoung-Woo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.91-100
    • /
    • 2011
  • This study presents the estimation for the possibility of liquefaction according to the liquefaction evaluation methods in Saemangeum reclamation area for tide embankment, Jeollabuk-do, Korea. Liquefaction estimation is performed by cyclic triaxial tests and seismic response analysis using earthquake records of the long- and short-term. This area appears to have greatly potential of liquefaction from the grain-size distribution curve of the dredged and reclaimed soil in the area. Because the liquefaction can occur in this area if the foundations or buried structures are built at a depth within 10m below ground surface, the meticulous care is required in the design of them in the future.

Seismic Behavior of High-rise Steel Moment-resisting Frames with Vertical Mass Irregularity (수직질량 비정형이 존재하는 고층 강 모멘트-저항골조의 지진 거동)

  • Park, Byong-Jeong;Song, In-Hawn
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-15
    • /
    • 2004
  • Dynamic analyses were carried out to study the seismic response of high-rise steel moment-resisting frames in sixteen story buildings. The frames are intentionally designed by three different design procedures; strength controlled design. strong column-weak beam controlled design. and drift controlled design. The seismic performances of the so-designed frames with vertical mass irregularities were discussed in view of drift ratio. plastic hinge rotation, hysteretic energy input and stress demand. A demand curve of hysteretic energy inputs was also presented with two earthquake levels in peak ground accelerations for a future design application.

Fragility assessment for electric cabinet in nuclear power plant using response surface methodology

  • Tran, Thanh-Tuan;Cao, Anh-Tuan;Nguyen, Thi-Hong-Xuyen;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.894-903
    • /
    • 2019
  • An approach for collapse risk assessment is proposed to evaluate the vulnerability of electric cabinet in nuclear power plants. The lognormal approaches, namely maximum likelihood estimation and linear regression, are introduced to establish the fragility curves. These two fragility analyses are applied for the numerical models of cabinets considering various boundary conditions, which are expressed by representing restrained and anchored models at the base. The models have been built and verified using the system identification (SI) technique. The fundamental frequency of the electric cabinet is sensitive because of many attached devices. To bypass this complex problem, the average spectral acceleration $S_{\bar{a}}$ in the range of period that cover the first mode period is chosen as an intensity measure on the fragility function. The nonlinear time history analyses for cabinet are conducted using a suite of 40 ground motions. The obtained curves with different approaches are compared, and the variability of risk assessment is evaluated for restrained and anchored models. The fragility curves obtained for anchored model are found to be closer each other, compared to the fragility curves for restrained model. It is also found that the support boundary conditions played a significant role in acceleration response of cabinet.

Soil vibration induced by railway traffic around a pile under the inclined bedrock condition

  • Ding, Xuanming;Qu, Liming;Yang, Jinchuan;Wang, Chenglong
    • Geomechanics and Engineering
    • /
    • v.24 no.2
    • /
    • pp.143-156
    • /
    • 2021
  • Rail transit lines usually pass through many complicated topographies in mountain areas. The influence of inclined bedrock on the train-induced soil vibration response was investigated. Model tests were conducted to comparatively analyze the vibration attenuation under inclined bedrock and horizontal bedrock conditions. A three-dimension numerical model was built to make parameter analysis. The results show that under the horizontal bedrock condition, the peak velocity in different directions was almost the same, while it obviously changed under the inclined bedrock condition. Further, the peak velocity under inclined bedrock condition had a larger value. The peak velocity first increased and then decreased with depth, and the trend of the curve of vibration attenuation with depth presented as a quadratic parabola. The terrain conditions had a significant influence on the vibration responses, and the inclined soil surface mainly affected the shallow soil. The influence of the dip angle of bedrock on the peak velocity and vibration attenuation was related to the directions of the ground surface. As the soil thickness increased, the peak velocity decreased, and as it reached 173% of the embedded pile length, the influence of the inclined bedrock could be neglected.

Seismic Performance of Steel Industrial Storage Racks Subjected to Korea Earthquakes (국내 발생지진에 의한 물류창고 강재 적재설비의 내진성능 평가)

  • Jeon, Jong-Su;Choi, Hyoungsuk;Seo, Youngdeuk;Kim, Chunggil;Heo, Gwanghee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.149-160
    • /
    • 2018
  • This study experimentally and analytically examines the seismic vulnerability of steel rack storage frames subjected to Korea earthquakes (2016 Gyeongju earthquake and 2017 Pohang earthquake). To achieve this aim, this study selects a three-story, one-bay steel rack frame with a typical configuration of rack frame in Korea. Firstly, the local behavior for frame components is examined by performing monotonic and/or cyclic load tests and the global response and dynamic characteristics of the subject rack frame are investigated by conducting a shaking table test. The analytical model of the rack frame is then created based on the experimental results and is used to perform nonlinear time history analyses with recorded Korea earthquakes. The seismic demand of the rack frame is considerably affected by the spectral acceleration response, instead of peak ground accelerations (peak floor accelerations). Moreover, the collapse fragility curve of the rack frame is developed using incremental dynamic analyses for the Gyeongju and Pohang earthquakes. Fragility results indicate that the ground motion characteristics of these earthquakes do not significantly affect the frame vulnerability at the collapse state.

Seismic Fragility Evaluation of Cut-and-cover Tunnel (박스형 터널의 지진 취약도 평가)

  • Park, Duhee;Nguyen, Duy-Duan;Lee, Tae-Hyung;Nguyen, Van-Quang
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.11
    • /
    • pp.71-80
    • /
    • 2018
  • In this study, the seismic response of cut-and-cover box tunnels is evaluated from pseudo-static analyses and the fragility curves are derived. A series of site profiles were used to evaluate the effect of soil conditions. A total of 20 ground motions were used. The fragility curves were developed as functions of peak ground acceleration for three damage states, which are minor, moderate, and extensive states. The damage indices, defined as the ratio of the elastic moment to the yield moment, correlated to three damage states, were used. The curves are shown to greatly depend on the site profile. The curves are further compared to those derived in previous studies. The widely used empirically derived curves are shown not to account for the site effects, and therefore underestimate the response for soft sites.

Comparison of Approximate Nonlinear Methods for Incremental Dynamic Analysis of Seismic Performance (내진성능의 증분동적해석을 위한 비선형 약산법의 비교 검토)

  • Bae, Kyeong-Geun;Yu, Myeong-Hwa;Kang, Pyeong-Doo;Kim, Jae-Ung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.79-87
    • /
    • 2008
  • Seismic performance evaluation of structure requires an estimation of the structural performance in terms of displacement demand imposed by earthquakes on the structure. Incremental Dynamic Analysis(IDA) is a analysis method that has recently emerged to estimate structural performance under earthquakes. This method can obtained the entire range of structural performance from the linear elastic stage to yielding and finally collapse by subjecting the structure to increasing levels of ground acceleration. Most structures are expected to deform beyond the limit of linearly elastic behavior when subjected to strong ground motion. The nonlinear response history analysis(NRHA) among various nonlinear analysis methods is the most accurate to compute seismic performance of structures, but it is time-consuming and necessitate more efforts. The nonlinear approximate methods, which is more practical and reliable tools for predicting seismic behavior of structures, are extensively studied. The uncoupled modal response history analysis(UMRHA) is a method which can find the nonlinear reponse of the structures for ESDF from the pushover curve using NRHA or response spectrum. The direct spectrum analysis(DSA) is approximate nonlinear method to evaluate nonlinear response of structures, without iterative computations, given by the structural linear vibration period and yield strength from the pushover analysis. In this study, the practicality and the reliability of seismic performance of approximate nonlinear methods for incremental dynamic analysis of mixed building structures are to be compared.