• Title/Summary/Keyword: ground loop

Search Result 258, Processing Time 0.031 seconds

A Digital Carrier Recovery Scheme for Satellite Transponder (디지털방식의 위성 트랜스폰더 반송파 복원 방안 연구)

  • Lee, Yoon-Jong;Choi, Seung-Woon;Kim, Chong-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10A
    • /
    • pp.807-813
    • /
    • 2009
  • A Satellite transponder is the Communication system to process signal with up-link signal recovery, and transmit to ground station through down-link. The orbit flight in the deep space causes high doppler shift in the received signals from the ground station so that the Carrier recovery and fast synchronization system are essential for the transponder system. The conventional analog transponder is employing the system's carrier recovery along with the PLL (Phase Locked Loop) designed for satellite's operation. This paper presents a digital carrier recovery scheme which can provide more reliable and software reconfigurable implementation technique for satellite transponder system without verifying scheme along with transponder designed for short distance or deep space satellite.

Flight Control System Design and Verification Process (비행제어시스템 설계 및 검증 절차)

  • Kim, Chong-Sup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.8
    • /
    • pp.824-836
    • /
    • 2008
  • Relaxed static stability(RSS) concept has been applied to improve aerodynamic performance of modern version supersonic jet fighter aircraft. Therefore, flight control systems are necessary to stabilize an unstable aircraft, and provides adequate handling qualities and achieve performance enhancements. Standard FCSDVP (Flight Control System Design and Verification Process) is provided to reduce development period of the flight control system. In addition, if this process is employed in developing flight control system, it reduces the trial and error for development and verification of flight control system. This paper addresses the flight control system design and verification process for the RSS aircraft utilizing design goal based on military specifications, linear and nonlinear system design and verification based on universal software, handling quality test based on HILS(Hardware In-the-Loop Simulator) environment, and ground and flight test results to verify aircraft dynamic flight responses.

Novel Shorted Meander-Line USB Dongle Antenna with a Compact Ground Plane

  • Jeong, Seong-Jae;Hwang, Keum-Cheol
    • ETRI Journal
    • /
    • v.32 no.4
    • /
    • pp.610-613
    • /
    • 2010
  • This letter presents the design of a novel multiband USB dongle antenna with a compact ground plane. The radiating patch is composed of a modified meander-line monopole and a shorted loop to generate a dual-broadband resonance. The proposed antenna supports WiBro, Bluetooth, WLAN, WiMAX, and S-DMB services. The total dimensions of the fabricated antenna are 10 mm ${\times}$ 45 mm ${\times}$ 1 mm, the most compact size among multiband USB dongle antennas reported to date. The measured 10 dB reflection loss bandwidths are 20.8% (2.24 GHz to 2.76 GHz) and 20.2% (4.86 GHz to 5.95 GHz). The measured peak gain is 2.97 dBi, and efficiency is higher than 58%. In addition, the radiation pattern approximates an omnidirectional pattern.

Regional Distribution of Ground Thermal Conductivity for Vertical Closed Type Ground Heat Exchanger Design (수직 밀폐형 지중열교환기 설계를 위한 지중 열전도도의 지역별 분포)

  • Jung, Kye-Hoon;Sohn, Byong-Hu;Lim, Hyo-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.423-428
    • /
    • 2007
  • This study was performed to construct a geothermal data base about thermal conductivity of ground heat exchanger and thermal properties of grouting material which used to refill the borehole. We have acquired geothermal data sets from 39 sites over wide area of South Korea except to Jeju island. From data analysis, the range of thermal conductivity is 1.5$\sim$4.0 W/mK. It means that thermal conductivity varies with grouting material as well as regional geology and ground water system.

  • PDF

RF Compatibility Test using RF Suitcase (이동형 RF 시험장비를 이용한 RF 호환성 시험)

  • Kim, Eung-Hyeon;Jeong, Dae-Won;Kim, Hui-Seop;Im, Jeong-Heum;Lee, Sang-Jeong
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.2
    • /
    • pp.45-50
    • /
    • 2006
  • A satellite and ground stations which are developed in a program are tested whether the interface between the satellite and ground is well established before satellite operations. These compatibility tests are performed when the satellite is connected with the ground stations after all satellite and ground stations requirements are verified. The content of the RF compatibility test is to check whether the interface requirements which are described on the Interface Control Document are well developed. During the early operation phase and tentative contingency operations of the satellite, KARI ground station uses other oversea ground stations which are located worldwide according to contract between the KARI and the contractor. Since oversea ground stations were not developed for the designated space program, system integrator should check whether the oversea ground stations are satisfied with interface requirements. Using the RF suitcase, RF interface and the content of RF communication can directly be verified during RF compatibility test on oversea ground station without KARI ground station's support. The RF compatibility test using RF suitcase was performed oversea ground stations as well as KARI ground station located on Korea. The content of RF compatibility test was standardized in order to be used at any oversea ground stations, especially fitted for the operations concept of launch and early operations phase. The test content would be RF characteristics, protocol, command loop test, telemetry loop test, and ground station interface test.

  • PDF

A Study of the Influence of Groundwater Level on the System Performance of Open Loop Geothermal System (지하수 수위가 개방형 지열시스템 성능에 미치는 영향에 관한 연구)

  • Kim, Jinsang;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.1-10
    • /
    • 2013
  • Open loop geothermal heat pumps have great potential where the groundwater resources are sufficient. Performance of open loop geothermal heat pump systems is considered higher than that of ground source heat pumps. Head and power calculation of submersible pumps, heat pump units, and piping are numerically based on regression data. Results shows that the system performance drops as the water level drops, and the lowest flow rates generally achieve the highest system COPs. The highest achievable cooling system COPs become 6.34, 6.12, and 5.95 as the groundwater levels are 5m, 15m, and 25m. The highest heating system COPs also become 4.59, 4.37, and 4.20. Groundwater level and submersible pump selection greatly influence the system performance of open loop geothermal heat pumps. It needs to be analysed during the design process of open loop geothermal heat pump system, possibly with analysis tools that include wide range of pump product data.

Development of the Water-leakage Detection Method Through the Geophysical Test on the Artificial Ground (모의지반 실험을 통한 누수영역 탐지기술 개발)

  • Kwon, Hyoung-Seok;Mitsuhata, Yuji;Uchida, Toshihiro
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.3
    • /
    • pp.39-46
    • /
    • 2009
  • A small loop-loop multi-frequency electromagnetic(EM) induction method is a useful technique to map a resistivity distribution efficiently and non-destructively. However, for quantitative interpretation and depth sounding, the quality of measured data is crucial. In this paper, we propose a bias correction of measured data by using background noise measurements to obtain reliable data, and propose an evaluation technique of apparent that can provide a resistivity image easily. We have performed small loop-loop EM measurements to detect water saturation in a man-made test site. The application of our proposed techniques to the measured data was successful.

  • PDF

Flexible camera series network for deformation measurement of large scale structures

  • Yu, Qifeng;Guan, Banglei;Shang, Yang;Liu, Xiaolin;Li, Zhang
    • Smart Structures and Systems
    • /
    • v.24 no.5
    • /
    • pp.587-595
    • /
    • 2019
  • Deformation measurement of large scale structures, such as the ground beds of high-rise buildings, tunnels, bridge, and railways, are important for insuring service quality and safety. The pose-relay videometrics method and displacement-relay videometrics method have already presented to measure the pose of non-intervisible objects and vertical subsidence of unstable areas, respectively. Both methods combine the cameras and cooperative markers to form the camera series networks. Based on these two networks, we propose two novel videometrics methods with closed-loop camera series network for deformation measurement of large scale structures. The closed-loop camera series network offers "closed-loop constraints" for the camera series network: the deformation of the reference points observed by different measurement stations is identical. The closed-loop constraints improve the measurement accuracy using camera series network. Furthermore, multiple closed-loops and the flexible combination of camera series network are introduced to facilitate more complex deformation measurement tasks. Simulated results show that the closed-loop constraints can enhance the measurement accuracy of camera series network effectively.

Study on physical characteristics of Graphite-added bentonite grout for backfilling closed-loop groud heat exchanger (수직 밀폐형 지중 열교환기용 뒤채움재로서 흑연(Graphite)을 첨가한 벤토나이트 그라우트재의 물리적 특성연구)

  • Lee, Kang-Ja;Gil, Hu-Jeong;Lee, Chul-Ho;Choi, Hang-Seok;Choi, Hyo-Pum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.179-187
    • /
    • 2009
  • Bentonite-based grouting has been popularly used to seal a borehole installed for a closed-loop vertical ground heat exchanger in a geothermal heat pump system (GHP) because of its high swelling potential and low hydraulic conductivity. The bentonite-based grout, however, has relatively lower thermal conductivity than that of ground formation. Accordingly, it is common to add some additives such as silica sand to the bentonite-based grout for enhancing thermal performance. In this study, graphite is adapted to substitute silica sand as an addictive because graphite has very high thermal conductivity. The effect of graphite on the thermal conductivity of bentonite-based grouts has been quantitatively evaluated for seven bentonite grouts from different product sources. In addition, comparisons of viscosity between applications of graphite and silica sand as additives has been carried out. In conclusion, using graphite has thermal conductivity about three times higher than that of silica sand.

  • PDF

Development of an Electric Circuit Transient Analogy Model in a Vertical Closed Loop Ground Heat Exchanger (수직밀폐형 지중열교환기의 회로 과도해석 상사모델 개발)

  • Kim, Won-Uk;Park, Hong-Hee;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.306-314
    • /
    • 2012
  • Several numerical or analytical models have been proposed to analyze the thermal response of vertical ground heat exchangers (GHEX). However, most models are valid only after several hours of operation since they neglect the heat capacity of the borehole. Recently, the short time response of the GHEX became important in system simulation to improve efficiency. In this paper, a simple new method to evaluate the short time response of the GHEX by using an analogy model of electric circuit transient analysis was presented. The new transient heat exchanger model adopting the concept of thermal capacitance of the borehole as well as the steady-state thermal resistance showed the transient thermal resistance of the borehole. The model was validated by in-situ thermal response test and then compared with the DST model of the TRNSYS program.