• Title/Summary/Keyword: ground loads

Search Result 494, Processing Time 0.032 seconds

Computational evaluation of wind loads on buildings: a review

  • Dagnew, Agerneh K.;Bitsuamlak, Girma T.
    • Wind and Structures
    • /
    • v.16 no.6
    • /
    • pp.629-660
    • /
    • 2013
  • This paper reviews the current state-of-the-art in the numerical evaluation of wind loads on buildings. Important aspects of numerical modeling including (i) turbulence modeling, (ii) inflow boundary conditions, (iii) ground surface roughness, (iv) near wall treatments, and (vi) quantification of wind loads using the techniques of computational fluid dynamics (CFD) are summarized. Relative advantages of Large Eddy Simulation (LES) over Reynolds Averaged Navier-Stokes (RANS) and hybrid RANS-LES over LES are discussed based on physical realism and ease of application for wind load evaluation. Overall LES based simulations seem suitable for wind load evaluation. A need for computational wind load validations in comparison with experimental or field data is emphasized. A comparative study among numerical and experimental wind load evaluation on buildings demonstrated generally good agreements on the mean values, but more work is imperative for accurate peak design wind load evaluations. Particularly more research is needed on transient inlet boundaries and near wall modeling related issues.

A Study on the Equivalent Circuit Modeling for Harmonics Analysis by Field Tests (현장시험에 의한 고조파 해석용 등가회로 모델링에 관한 연구)

  • 김경철;최종기;백승현;김종욱
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed It has been also known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages, and the soil resistivity and ground resistance under case study system were made and the corresponding equivalent circuit for the harmonics analysis was developed This equivalent circuit model was simulated numerically and graphically through the use of MATLAB and CDEGS software packages, and adequate results were obtained.

Development and Application of Polymer-based Flexible Force Sensor Array (폴리머 재료를 이용한 유연 수직/수평 힘 센서 어레이 개발 및 응용)

  • Hwang, Eun-Soo;Yoon, Young-Ro;Yoon, Hyoung-Ro;Shin, Tae-Min;Kim, Yong-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.142-149
    • /
    • 2009
  • This paper proposes and demonstrates novel flexible contact force sensing devices for 3-dimensional force measurement. To realize the sensor, polyimide and polydimethylsiloxane are used as a substrate, which makes it flexible. Thin-film metal strain gauges, which are incorporated into the polymer, are used for measuring the three-dimensional contact forces. The force sensor characteristics are evaluated against normal and shear load. The fabricated force sensor can measure normal loads up to 4N. The sensor output signals are saturated against load over 4N. Shear loads can be detected by different voltage drops in strain gauges. The device has no fragile structures; therefore, it can be used as a ground reaction force sensor for balance control in humanoid robots. Four force sensors are assembled and placed in the four corners of the robot's sole. By increasing bump dimensions, the force sensor can measure load up to 20N. When loads are exerted on the sole, the ground reaction force can be measured by these four sensors. The measured forces can be used in the balance control of biped locomotion system.

Comparison of Aerodynamic Loads for Horizontal Axis Wind Turbine (II): with and without Vertical Wind Shear Effect (수평축 풍력터빈의 공력 하중 비교 (II): 수직 전단흐름 효과의 유·무)

  • Kim, Jin;Kang, Seung-Hee;Ryu, Ki-Wahn
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.5
    • /
    • pp.399-406
    • /
    • 2016
  • The large scale wind turbine blades usually experience periodic change of inflow speed due to blade rotation inside the ground shear flow region. Because of the vertical wind shear, the inflow velocity in the boundary layer region is maximum at uppermost position and minimum at lowermost position. These spatial distribution of wind speeds can lead to the periodic oscillation of the 6-component loads at hub and low speed shaft of the wind turbine rotor. In this study we compare the aerodynamic loads between two inflow conditions, i.e, uniform flow (no vertical wind shear effect) and normal wind profile. From the computed results all of the relative errors for oscillating amplitudes increased due to the ground shear flow effect. Especially bending moment and thrust at hub, and bending moments at LSS increased enormously. It turns out that the aerodynamic analysis including the ground shear flow effect must be considered for fatigue analysis.

Quasi-Static Analysis of Block Impact Against the Ground Due to Sling Failure During Block Lifting (권상 작업 중 슬링 파손으로 인한 블록 지상 낙하 충격에 대한 준정적 해석)

  • Kim, Seon-Yeob;Lee, Tak-Kee;Yoon, Jung-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.2
    • /
    • pp.84-89
    • /
    • 2021
  • Recently, shipyards are making many efforts to reduce the number of the mounted blocks by increasing the block size. This is to improve productivity and reduce related costs by minimizing block movement and shortening the building period. However, as the blocks become larger, the weight increases considerably. If the target block has a damage due to an unexpected accident during block lifting, it may seriously cause a problem of the reusability of the block. In this study, a large-sized block of the offshore structure weighing 480 tons was lifting with a total of seven sling belts, and one sling belt was broken while it was moving, resulting in a situation in which a part of the edge of the block collided with the ground. The aim of this paper is to verify the structural integrity of the block that directly collides with the ground in the form of free fall due to the sling breakage. Considering that the hook loads acting on several sling belts holding the block are redistributed when a sling belt is broken, the hook loads were recalculated at the angle just before the sling breakage. These loads were used to check the safety of the sling belts. In addition, FE analysis was performed by calculating the amount of impact from the free fall condition, obtaining the impact area by using Hertz's contact theory, and then applying the impact load to the area.

A Case Study on Elephant Foot Method for Tunnelling in the Soft Ground (토사터널에서의 각부보강공법 적용성 연구)

  • Park, Chi-Myeon;Lee, Ho;Park, Jae-Hoon;Yoon, Chang-Ki;Hwang, Je-Don
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.863-874
    • /
    • 2009
  • The engineering characteristics and the reinforcement effect of the elephant foot method were discussed with parametric study. The elephant foot method is adopted to support the loads transferred from tunnel crown and improve bearing capacity of elephant foot in poor ground condition. The evaluation of reinforcement effect, which has the mechanical relationship between ground condition, footing size and reinforcement system, was carried out through the previous research and numerical analysis. In addition, the simple design chart was proposed to estimate the applicability of the elephant foot reinforcement method. It will be practical for the engineer to determine the optimum reinforcement method for safe tunnelling in soft ground condition.

  • PDF

The Ground Impedance Modeling for Neutral Harmonic Analysis by Field Tests (현장시험에 의한 중성선 고조파 해석용 접지 임피던스 모델링)

  • Kim Kyung Chul;Park Seung Hyun;Choi Jong Ki;Lee Il Moo;Kim Jong Uk
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.369-371
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed. It has been. known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages according to the fell-of-potential method under case study system were made and the ground impedance modeling using the pattern search method for the harmonic analysis was developed. The ground impedance model obtained by the proposed method was compared with the frequency characteristics by field tests and has shown appropriate results, and would be applicable to evaluate the harmonic and transient response characteristics of the ground system.

  • PDF

Working Principle of a Novel Three-directional Dumping Vehicle and Its Dumping Stability Analysis Under Ground-slope Conditions

  • Kong, Min-kyu;Park, Tusan;Shim, Sung-Bo;Jang, Ik Joo
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.235-241
    • /
    • 2017
  • Purpose: It is to develop an agricultural three-directional dumping vehicle that can help farmers reduce intensive labor when carrying heavy loads and for easy dumping. In addition, a novel mechanism was applied for controlling the direction of the tilting cargo box by using a single hydraulic cylinder and simple apparatus. The overturning safety was analyzed to provide safe-use ground slope region of the vehicle to be used at upland fields and orchards. Methods: The developed three-directional dumping vehicle was constructed using a cargo box, vehicle frame, driving components, lifting components, and controller. The novel mechanism of controlling the dumping direction involves the operation of two latching bars, which selectively release or collapse the connecting edge between the vehicle frame and cargo box. A multibody dynamics analysis software (RecurDynV8R5) was used to determine the safe-use ground slope area when tilting the cargo box at slopes. A computer analysis was conducted by increasing the ground slope while rotating the vehicle when the cargo box comprised loads of 300 and 500 kg and stacking heights of 40 and 80 cm, respectively. Results: The three-directional dumping vehicle was successfully manufactured, and the cargo box was tilted at $37^{\circ}$ and $35^{\circ}$ for dumping forward and sideways. The latching bars were manually and selectively collapsed with the vehicle frame to control the dumping direction. When forward dumping, the safe-use ground slope was over $20^{\circ}$ in all vehicle directions and loaded conditions. Conclusions: A three-directional dumping vehicle was developed to reduce labor-intensive work in the farming environment. The user can easily control the dumping direction by using the control panel. The vehicle was safe to be used in most of the Korean upland fields and orchards (area over 96%) for the forward dumping.

Cooling and Heating Performance Evaluation of a GSHP System (지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가)

  • Sohn Byong Hu;Cho Chung-Sik;Shin Hyun-Jun;An Hyung-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.

A Study on Behavior of 2-Arch Tunnel by Numerical Approach (수치해석적 접근을 통한 2Arch 터널의 거동양상 고찰)

  • 김상균;박동욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.225-232
    • /
    • 2003
  • The behaviour of ground induced by tunneling of 2arch tunnels may differ from the one caused by usual type tunnels. This paper describe the behaviour created by the size of pilot tunnel and the condition on the construction method of center piller Also, loads acting on the supports of the first tunnel and the center pillar during the excavation of second tunnel is investigated by numerical analyses. The results of numerical analyses are compared to the data records of measurement results, i.e. force on the support system and ground displacement.

  • PDF