• 제목/요약/키워드: ground borehole

검색결과 207건 처리시간 0.05초

Application of integrated geophysical methods to investigate the cause of ground subsidence of the highly civilized area

  • Kim Jung-Ho;Yi Myeong-Jong;Hwang Se-Ho;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.410-415
    • /
    • 2003
  • Ground subsidence has occurred in the downtown of Muan-eup in Korea. Integrated geophysical survey, including two-dimensional resistivity, CSMT(Controlled source magnetotelluric), magnetic, borehole logging, GPR and resistivity tomography, has been conducted to investigate the cause of subsidence and ground conditions. Since the target area is in the city downtown, there were no spaces for surface geophysical methods. To get regional geology and to facilitate the detailed geophysical interpretation in the survey area, two-dimensional resistivity, CSMT and magnetic surveys have been applied in the outer region of the downtown. From these results, we could accurately define the Gwangju fault system and estimate the geologic conditions in the downtown. For the detailed survey of the downtown area, resistivity tomography and borehole logging data have been acquired using a few tens of densely located boreholes. Among these survey results, borehole logging data provided the guide to classification of the rock type and we could define the geologic boundary of granite and limestone formations. From the resistivity tomograms of 42 sections, which are densely located enough to be interpreted in a three-dimensional manner, we could delineate the possible weak zones or cavities in the limestone formations. In particular, resistivity tomograms in the subsided area showed the real image of ground subsidence. The map of hazardous zone has been derived from the joint interpretation of these survey results and we could provide the possible reinforcement strategy in this area.

  • PDF

Mapping Submarine Bathymetry and Geological Structure Using the Lineament Analysis Method

  • Kwon, O-Il;Baek, Yong;Kim, Jinhwan
    • 지질공학
    • /
    • 제24권4호
    • /
    • pp.455-461
    • /
    • 2014
  • The Honam-Jeju, Korea-Japan, and Korea-China subsea tunnel construction projects have drawn significant attention since the early 2000s. These subsea tunnels are much deeper than most existing natural shallow sea tunnels linking coastal areas. Thus, the need for developing new technologies for the site selection and construction of deep subsea tunnels has recently emerged, with the launch of a research project titled "Development of Key Subsea Tunnelling Technology" in 2013. A component of this research, an analysis of deep subsea geological structure, is currently underway. A ground investigation, such as a borehole or geophysical investigation, is generally carried out for tunnel design. However, when investigating a potential site for a deep subsea tunnel, borehole drilling requires equipment at the scale of offshore oil drilling. The huge cost of such an undertaking has raised the urgent need for methods to indirectly assess the local geological structure as much as possible to limit the need for repeated borehole investigations. This study introduces an indirect approach for assessing the geological structure of the seafloor through a submarine bathymetry analysis. The ultimate goal here is to develop an automated approach to the analysis of submarine geological structures, which may prove useful in the selection of future deep subsea tunnel sites.

경계 조건에 따른 지열 응답 함수의 차이가 수직형 지열 교환기 길이 산정에 미치는 영향 (Impact of Different Boundary Conditions in Generating g-function on the Sizing of Ground Heat Exchangers)

  • 김의종
    • 설비공학논문집
    • /
    • 제26권6호
    • /
    • pp.263-268
    • /
    • 2014
  • Eskilson's g-function, a well-known geothermal heat response factor, is widely used for sizing of the ground heat exchangers. Unlike the Eskilson's original model that uses common temperature boundaries for all boreholes and along the borehole height, an analytical-solution-based g-function uses a uniform heat transfer rate over the height with variable heat transfer rates for respective boreholes. To evaluate the impact of such a boundary difference on g-function and the design length, a simple case study was carried out on the cooling-dominant commercial buildings. The results show that the design lengths given by the boundary of uniform heat transfer rates are longer than those given by Eskilson's boundary for all cases tested. The difference in length is more important when the bore field is composed of more boreholes with shorter length of each borehole.

지중열원 열펌프시스템의 성능해석 (A Study on the Performance of Ground Source Heat Pump System)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.69-76
    • /
    • 2005
  • The performance of water-to-water heat pump system coupled with the ground source vertical heat exchanger is presented in this paper. The CAP program of Florida Heat Pump Co. is used to predict the heat pump performances while the EED program calculates the borehole fluid temperature. It is shown that COPH increases with decreasing the temperature of output water for the operation of heating mode and COPR increases with increasing temperature of output water for the operation of cooling mode. The value of specific heat extraction rate must be moderate to insure the reasonable installation cost of borehole system. With $1^{\circ}C$decrease of $T_{wo}$ the average COPH increase is estimated as about $0.06/^{\circ}C$(for $T_{wo}\;=\;45{\sim}60^{\circ}C$ range) while with $1^{\circ}C$ increase of $T_{wo}$ the estimation of COPR increase is about $0.13/^{\circ}C$(for $T_{wo}\;= \;5{\sim}11^{\circ}C$ range) at the specific heat extraction rate of 30W/m.

스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구 (An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger)

  • 이상훈;최용석;안근묵
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF

히트펌프용 수직형 지중열교환기의 성능에 관한 연구 (A Study on Performance of Vertical Ground Heat Exchanger for Heat Pump)

  • 장기창;정민호;윤형기;나호상;유성연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.466-469
    • /
    • 2007
  • Heat pumps are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. And a vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double n-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

시추공 온도자료를 이용한 고기후 연구에 대한 개관 (A Review on the Paleoclimate Change Inferred from Borehole Temperatures)

  • 이영민;김형찬;송윤호
    • 자원환경지질
    • /
    • 제39권1호
    • /
    • pp.95-102
    • /
    • 2006
  • 19세기말부터 진행된 지구온난화를 규정하기 위해서는 기상관측목적의 지표대기온도(Surface air temperature; SAT) 측정이 시작된 19세기말 이전의 온도 자료가 필요하다. 다행히 과거의 지표온도(Ground surface temperature; GST)가 지중으로 전파되어 기록된 시추공 온도자료로 일반적으로 과거 약 1,000년 전까지의 기온변화에 대한 정보를 얻을 수 있다. 시추공 온도자료로부터 복원된 과거의 기온변화의 정보는 19세기말부터 시작된 지구온난화를 규정하고 또한 그 이전에 있었던 소빙하기(Little Ice Age)와 중세온난기(Medieval Warm Period) 같은 기후변화를 알아내는데 유용하게 사용될 수 있다.

TRNOPT를 이용한 수직 지중열교환기 길이 산정 방법에 관한 연구 (Sizing of Vertical Borehole Heat Exchangers using TRNOPT)

  • 박승훈;이현수;장용성;김의종
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.402-407
    • /
    • 2016
  • Ground-coupled heat pump systems have been widely used, as they are regarded as a renewable energy source and ensure a high annual efficiency. Among the system components, borehole heat exchangers (BHE) play an important role in decreasing the entering water temperature (EWT) to heat pumps in the cooling season, and consequently improve the COP. The optimal sizing of the BHEs is crucial for a successful project. Other than the existing sizing methods, a simulation-based design tool is more applicable for modern complex geothermal systems, and it may also be useful since design and engineering works operate on the same platform. A simulation-based sizing method is proposed in this study using the well-known Duct STorage (DST) model in Trnsys. TRNOPT, the Trnsys optimization tool, is used to search for an optimal value of the length of BHEs under given ground loads and ground properties. The result shows that a maximum EWT of BHEs during a design period (10 years) successfully approaches the design EWT while providing an optimal BHE length. Compared to the existing design tool, very similar lengths are calculated by both methods with a small error of 1.07%.

터널 갱구 2 Arch 굴착에 따른 안정성 해석 (Stability Analysis for Two Arch Excavation of a Tunnel Portal)

  • 이길재;유광호;박연준;채영수
    • 터널과지하공간
    • /
    • 제12권3호
    • /
    • pp.179-188
    • /
    • 2002
  • 본 연구는 한 경부 고속철도 터널의 NATM 굴착에 의한 2 arch 확공 굴착 시 발생되는 진동 및 응력의 변화가 터널 및 인근 사면에 미치는 영향을 사전에 파악하여 안정성을 검토하는 데에 그 목적이 있다. 지반물성치를 산정하기 위해 시추공 조사, TV검층 및 속도검층을 실시하였다. 2차원 해석을 통해 불확실한 지반의 물성을 변수로 간주하고 가능한 범위 내에서 해석을 수행함으로서 특정한 지반 물성이 입력 정수로서 결정되었다. 정적 및 발파 진동에 의한 준-정적(pseudo-static)안전율을 계산하였으며, 3차원 해석을 통해 터널굴착으로 인한 터널 및 터널 주변의 거동과 터널 지보재의 적정성 여부를 조사하였다.

Seismic analysis of shear wall buildings incorporating site specific ground response

  • Jayalekshmi, B.R.;Chinmayi, H.K.
    • Structural Engineering and Mechanics
    • /
    • 제60권3호
    • /
    • pp.433-453
    • /
    • 2016
  • During earthquake, the motion of ground is affected significantly by source characteristics, source-to-site path properties and local site conditions. Due to the influence of local soil conditions different places experience distinctive amplitude of surface ground motion. Ground response analysis of a specific site utilizing the borehole information at different locations is done in present study. The ground motion with the highest peak ground acceleration for this site obtained from the ground response analysis is used in finite element soil-structure interaction analysis of multi-storey shear wall buildings with various positions of shear walls. The variation in seismic response of buildings and advantageous position of shear wall are determined. The study reveals that providing shear wall at the core of buildings at the specific site is advantageous among all shear wall configurations considered.