• 제목/요약/키워드: ground analysis

검색결과 7,694건 처리시간 0.035초

봉상접지전극의 접지임피던스의 주파수의존성의 분석 (Analysis of the Frequency Dependent Characteristics of Ground Impedance of a Ground Rod)

  • 이복희;엄주홍
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권8호
    • /
    • pp.426-432
    • /
    • 2004
  • This paper presents a systematic approach of measurement, modeling and analysis of grounding system impedance in the field of lightning protection system and intelligent power equipments. The measurement and analysis system of ground impedance is based on a computer aided technique. The magnitude and phase of ground impedance were determined by the novel measurement and analysis using the revised fall-of-potential method. The ground impedances of the ground rod of 50 m long are considerably dependent on the frequency. The ground impedance is mainly resistive in the frequency range of 3-20 kHz. At higher frequencies, the reactive components of the ground impedances are no longer negligible and the inductance of the ground rod was found to be the core factor deciding the ground impedance. Although the steady-state ground resistance of the ground rod of 50 m was less than that of the ground rod of 10 m, the ground impedances of the ground rod of 50 m over the frequency range of more than 60 kHz were much greater than those of the ground rod of 10 m. Furthermore, the equivalent circuit model based on the measured data was proposed. and the calculated results were in approximately agreement with the measured data.

지반변동성을 고려한 액상화 진동전단응력비의 확률론적 해석 (Probabilistic Analysis of Liquefaction Cyclic Stress Ratio Considering Soil Variability)

  • 허준
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.95-101
    • /
    • 2018
  • The objective of this study is to evaluate the liquefaction cyclic shear stress ratio considering the soil uncertainty. In this study, the probabilistic ground response analysis and the cyclic shear stress ratio analysis for the liquefaction potential evaluation are performed considering the soil variability. The statistical properties of input ground parameters were analyzed to investigate the parameters affecting the seismic response analysis. The Probabilistic analysis was carried out by Monte Carlo Simulation method. The ground response analysis was performed considering the soil variability and the probability distribution characteristics of the ground acceleration. The probability distribution of the peak ground acceleration by seismic characteristics was presented. The differences of liquefaction shear stress ratio results according to soil variability were compared and analyzed. The maximum acceleration of the ground by the deterministic method was analyzed to be overestimation of the ground amplification phenomenon. Also, the shear stress ratio was overestimated.

가상고정점기법이 적용된 잔교식 구조물의 응답스펙트 럼해석법 개선사항 도출 연구 (Study on the Improvement of Response Spectrum Analysis of Pile-supported Wharf with Virtual Fixed Point)

  • 윤정원;한진태
    • 한국지진공학회논문집
    • /
    • 제22권6호
    • /
    • pp.311-322
    • /
    • 2018
  • As a method of seismic-design for pile-supported wharves, equivalent static analysis, response spectrum analysis, and time history analysis method are applied. Among them, the response spectrum analysis is widely used to obtain the maximum response of a structure. Because the ground is not modeled in the response spectrum analysis of pile-supported wharves, the amplified input ground acceleration should be calculated by ground classification or seismic response analysis. However, it is difficult to calculate the input ground acceleration through ground classification because the pile-supported wharf is build on inclined ground, the methods to calculate the input ground acceleration proposed in the standards are different. Therefore, in this study, the dynamic centrifuge model tests and the response spectrum analysis were carried out to calculate the appropriate input ground acceleration. The pile moment in response spectrum analysis and the dynamic centrifuge model tests were compared. As a result of comparison, it was shown that the response spectrum analysis results using the amplified acceleration in the ground surface were appropriate.

심층혼합공법의 최저 개량 심도 결정에 관한 해석적 연구 (An Analytical Study on the Determination of the Lowest Improvement Depth of Deep Mixing Method)

  • 박춘식;송지원
    • 한국지반신소재학회논문집
    • /
    • 제19권1호
    • /
    • pp.35-44
    • /
    • 2020
  • 연약지반 개량 공법 중 심층혼합공법에 대한 설계 기법으로는 복합지반으로 해석하는 방법과 말뚝지반으로 해석하는 방법이 있다. 그러나 이러한 해석에 대한 비교 연구는 부족한 실정으로 설계 시 해석 기준을 명확하게 정의 내리는 것에 어려움이 있다. 본 연구에서는 2차원 및 3차원 해석을 통해 성토 높이와 연약지반의 심도, 보강구간의 치환율을 변화시키며 각 조건별로 복합지반과 말뚝지반을 가정하여 해석하였다. 그 결과 최저 개량 심도는 3차원 해석에 비해 2차원 해석 결과가 6.85~9.08% 더 깊은 결과를 도출하였다. 또한 말뚝지반 해석의 경우 복합지반 해석에 비해 개량 심도는 12.22~14.45% 더 깊은 것을 확인하였다. 이 결과를 통하여 보다 정확한 설계를 위해서는 2차원 해석보다는 3차원 해석을 실시해야 하고, 경제적인 설계를 위해서는 복합지반으로 해석해야 하며, 안정적인 설계를 위해서는 말뚝지반 해석을 실시해야 된다고 판단된다.

도심지 지반함몰의 초기발생현상에 대한 흐름해석적 접근 (Flow Analysis Approach to Triggering Phenomenon of Ground Sinking in a Metropolitan Area)

  • 조영석;장연수
    • 토지주택연구
    • /
    • 제8권1호
    • /
    • pp.13-22
    • /
    • 2017
  • In this study, triggering mechanism of ground sinking was analyzed through groundwater flow analysis on the basis of a case of the ground sinking occurred in Yongsan in 2015. The results of geotechnical investigation performed before and after the ground sinking were analyzed for the accurate understanding of geological features in the study area. The numerical groundwater flow analysis was performed to evaluate the influence of the flow behavior from the surrounding area toward the excavated site using software of Visual MODFLOW. As a result, it was found from the geotechnical analysis that the strata of sedimentary layer along the sunken area in the vertical direction was mixed significantly after the ground sinking compared with the status of the soil condition before the ground sinking. Piping was occurred at the toe of cut-off wall in the sandy gravel layer, and this phenomenon was predicted by the numerical flow analysis. Sequential ground displacement scenario of the ground sinking was derived from the geotechnical in situ test and numerical flow analysis performed in this study.

건물의 냉난방 운전을 고려한 3차원 동적 지중 열교환기 열해석 모델 (Three-dimensional Equivalent Transient Ground Heat Exchanger Thermal Analysis Model by Considering Heating and Cooling Operations in Buildings)

  • 백승효
    • 토지주택연구
    • /
    • 제9권4호
    • /
    • pp.25-32
    • /
    • 2018
  • Application of geothermal energy in buildings has been gaining popularity as it provides the benefits of both heating and cooling a building. Among the various types of geothermal energy systems, ground-coupled heat pump system is the most commonly applied one in South Korea. A ground heat exchanger plays an important role as a heat source in winter and a heat sink in summer. For the stable operation of a ground-coupled heat pump system, a ground heat exchanger should be sized so that it provides sufficient heating and cooling energy. Heating and cooling energies generated in ground heat exchangers mainly depend on the temperature difference between the heating medium in ground heat exchangers and the surrounding ground. In addition, the performance of ground heat exchangers influences the change in ground temperature. Therefore, it is necessary to consider this interrelation between the change in the ground temperature and the performance of ground heat exchanger for an accurate estimation of its performance. However, previous thermal analysis models for ground heat exchangers are not competent enough to allow a complete understanding of this interrelation. Therefore, this study proposes a three-dimensional equivalent, transient ground heat exchanger analysis model. First, a previous thermal analysis model for ground heat exchangers, including an analytical model, a g-function, and a numerical model are analyzed. Next, to overcome the limitations of the previous models, a three-dimensional equivalent, transient ground heat exchanger model is proposed. Finally, this study validated the proposed model with the measurement data of the thermal response test, sandbox test, and TRNSYS DST model. All validation results showed a good agreement. These findings helped us to investigate the thermal performance of ground heat exchangers more accurately than the analytical models, and faster than the numerical models. Furthermore, the proposed model contributes to the design of ground heat exchangers by considering the different operation conditions of buildings.

Seismic analysis of shear wall buildings incorporating site specific ground response

  • Jayalekshmi, B.R.;Chinmayi, H.K.
    • Structural Engineering and Mechanics
    • /
    • 제60권3호
    • /
    • pp.433-453
    • /
    • 2016
  • During earthquake, the motion of ground is affected significantly by source characteristics, source-to-site path properties and local site conditions. Due to the influence of local soil conditions different places experience distinctive amplitude of surface ground motion. Ground response analysis of a specific site utilizing the borehole information at different locations is done in present study. The ground motion with the highest peak ground acceleration for this site obtained from the ground response analysis is used in finite element soil-structure interaction analysis of multi-storey shear wall buildings with various positions of shear walls. The variation in seismic response of buildings and advantageous position of shear wall are determined. The study reveals that providing shear wall at the core of buildings at the specific site is advantageous among all shear wall configurations considered.

지반 응답 해석 Round Robin Test의 입력 지반 물성에 따른 지반 응답 특성 영향 고찰 (Effect of Input Soil Properties for Round Robin Test on Ground Response Analysis)

  • 김동수;이세현;추연욱;박성식;김동준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.305-316
    • /
    • 2007
  • Free field ground motion during earthquake is significantly affected by the local soil conditions and it is essential for the seismic design to perform the site specific ground response analysis. So, Round Robin Test (RRT) on ground response analysis was performed for three sites in Korea. A total of 12 teams presented the results of ground response analysis with used input soil properties based on own judgement. In this paper, the results of one dimensional equivalent linear analysis presented by 11 teams were compared to evaluate the effect of input soil properties on ground response analysis. Additionally, 4 influence factors on ground response analysis, that is shear wave velocity of soil layer, nonlinear dynamic deformational characteristics, bedrock depth and bedrock velocity were studied for assumed simple soil conditions.

  • PDF

매립토층에서 CGS에 의한 지반개량특성에 관한 연구 (Characteristics of Ground Improvement by Compaction Grouting System in Filled Ground)

  • 천병식;여유현;정영교;정완균;정의원;김우종
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.425-432
    • /
    • 2001
  • Compaction Grouting System, the method which makes ground compact by injection of low slump mortar, Is widely used for reinforcement of soft ground, restoration of structures happened differential settlement, underpinning and restoration of damaged dam core. The quantitive analysis of ground improvement for this method has not performed yet. So, design parameters about thls method must be studied through performance of CGS in various types of soil to make CGS adaptable widely. In this study PBT, SPT and field density test were performed for analysis of the characteristics of ground improvement and pressuremeter and inclinometer were installed for analysis of the characteristics of compaction in adjacent ground. In this paper, denoted much effects for filled ground that increasing of the bearing capacity, confirming the displacement of adjacent ground and the effective radius of injection.

  • PDF

봉상전극 접지임피던스의 측정과 이론적 분석 (Theoretical analysis and measurement of Ground impedance of Ground rods)

  • 이복희;이태형;이수봉;엄주홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1876-1878
    • /
    • 2004
  • A systematic approach of measurement, modeling and analysis of grounding system impedance is presented. The measurement and analysis system of ground impedance is based on a computer aided technique. The ground impedances of the ground rod are considerably dependent on the frequency. The ground impedance is mainly resistive in the frequency range of 3-20 kHz. At higher frequencies, the reactive components of the ground impedances are no longer negligible and the inductance of the ground rod was found to be the core factor deciding the ground impedance. As a consequence, the equivalent circuit model based on the measured data was proposed, and the calculated results were in approximately agreement with the measured data.

  • PDF