• 제목/요약/키워드: greenhouse test

검색결과 434건 처리시간 0.027초

지열을 이용한 온실용 냉난방시스템 개발 (Development of a Cooling and Heating System for Greenhouse using Geothermal Energy)

  • 이용범;조성인;이재한;김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.688-692
    • /
    • 2005
  • Importance of substitute energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to $40\%$ of the total production cost in Korean protected cultivation needs to be reduced for profitability and global competition. But, studying on substitute energy to solve these problems has not been activated for Korean protected cultivation. Therefore, this study was conducted to develop a geothermal heat pump system for cool ing and heat ing of greenhouses at a lower cost than conventional hot air heater and air conditioner. Fundamental test of heat transfer characteristics in soil was conducted by computer simulation and controlled tests for its verification. Based on the results of the theoretical and empirical investigations, an optimum heat pump system was developed and the performance was evaluated for practical use in a greenhouse at the Pusan Horticultural Experiment Station. The system was compared with a conventional hot air heating system through a cucumber growing test and economic feasibility analysis. Results of the application test of the geothermal heat pump showed that with an initial setting of $15^{\circ}C$ the inside temperature of the greenhouse could be maintained between 15 and $17^{\circ}C$. Results of the cucumber growing test showed that there were no significant differences in average height, leaf length, leaf width, number of nods, leaf area, dry weight and yield between the plots wi th the geothermal heat pump system and a conventional hot air heater. Economic feasibility analysis indicated that the variable cost of the hot air heater could be saved $81.2\%$ using the geothermal heat pump system. It was concluded that the geothermal heat pump system might be a pertinent heating and cooling system for greenhouses because of the low operating cost and the use of environment-friendly geothermal energy.

  • PDF

시설원예용 제습기 개발 (Development of Dehumidifier for Protected Horticulture)

  • 연광석;강금춘;강연구;유영선;김영중;백이
    • Journal of Biosystems Engineering
    • /
    • 제30권2호
    • /
    • pp.110-113
    • /
    • 2005
  • Relative humidity of air In the greenhouse has to be maintained at 70 to 80 percents to provide a better growth condition of crops. To control relative humidity of air in the greenhouse, a dehumidifier functioning by refrigeration cycle was designed and manufactured in this study. And, results of its performance test in the greenhouse site were reported. The developed dehumidifier has separated condenser and evaporator in the heat exchanger part in order to increase dehumidifying capacity at a low temperature condition. When the conditions of incoming air into the dehumidifier were temperature of $15\~25^{\circ}C$ and relative humidity of $0\~95\%$, quantity of condensed water per hour, ie, dehumidification rate was $4.7\~7.0\;kg/hr$. Relative humidity difference was not greater than 5 percents at various locations in the greenhouse due to proper distributing of dehumidified air through vinyl duct. Thermal energy output from the developed dehumidifier was about 8,5000 kcal/hr that was 7 percents of maximum greenhouse heating load of 10 a.

De-NOx 저감장치가 온실가스 배출량에 미치는 영향 연구 (A Study on the Effect of De-NOx Device on GHG Emissions)

  • 김성우;김정환;김기호;오상기
    • 한국분무공학회지
    • /
    • 제23권4호
    • /
    • pp.212-220
    • /
    • 2018
  • As increase the number of vehicles, the issue of greenhouse gas that was emitted by them became important. As a result, greenhouse gas (GHG) regulations are being strengthened and efforts are being actively made to reduce greenhouse gas emissions in the automotive industry. In the other hand, regulations for harmful emission of vehicles have been reinforced by step. Especially, the lastly applied step, so called Euro 6, not only decreased NOx limit down to half of Euro 5 but also introduced real driving emission limit for NOx and PN. It is a challenge for manufacturers to meet the recent GHG regulation as well as the latest emission regulation. To overcome these regulations a De-NOx after-treatment system is being applied to diesel vehicles that are known emitting the lowest GHG among conventional internal combustion engines. At the time of the introduction of Euro 6 emission standard in Korea, in the domestic fuel economy certification test, some diesel vehicles emitted more $CH_4$ than Euro 5 vehicles. As a result, it was confirmed that LNT-equipped vehicles emitted a high level $CH_4$ and the level exceeded the US emission standard. In order to determine the reason, various prior literature was investigated. However, it was difficult to find a detailed study on the methane increase with LNT. In this paper, to determine whether the characteristics of vehicles equipped with LNT the affects the above issue and other greenhouse gases, 6 passenger cars were tested on several emission test modes and ambient temperatures with a environment chamber chassis dynamometer. 2 cars of these were equipped with LNT only, other 2 cars had SCR only, and LNT + SCR were applied to remaining 2 cars. The test result shown that the vehicles equipped with LNT emitted more $CH_4$ than the vehicles with SCR only. Also, $CH_4$ tended to increase as the higher acceleration of the test mode. However, as the test temperature decreases, $CH_4$ tended to decreased. $CO_2$ was not affected by kinds of De-NOx device but characteristic of the test modes.

고압고온 재생조건에서의 암모니아수-CO2 반응특성 (Characteristics of Aqueous Ammonia-CO2 reaction at Regeneration Condition of High Temperature and Pressure)

  • 김윤희;이광복;박성열;고창현;박종호;범희태;한명완;김종남
    • Korean Chemical Engineering Research
    • /
    • 제48권2호
    • /
    • pp.253-258
    • /
    • 2010
  • 암모니아수를 이용한 이산화탄소 흡수분리공정에서 흡수액의 재생조건(온도, 압력)이 이산화탄소 흡수성능에 미치는 영향을 조사하였다. 실험에 사용된 흡수액은 탄산암모늄($(NH_4)_2CO_3$)을 물에 용해시키어 $CO_2$ 로딩($mol\;CO_2/mol\;NH_3$)이 0.5, 용액 내의 암모니아수 농도가 14, 20, 26 및 32 wt%로 되도록 제조하였고, 이산화탄소의 흡수에 앞서 재생압력(6~18 bar)을 조절하면서 $120{\sim}160^{\circ}C$의 온도범위로 제조된 흡수액을 가열하여 재생하였다. 재생된 흡수액을 기포 반응기에 넣고 12 vol%의 $CO_2$를 함유한 기체를 주입하여 흡수반응을 수행하였다. 실험결과 26 wt%의 암모니아수가 대체적으로 $CO_2$ 흡수량이 높았으며, 특히 재생온도가 $150^{\circ}C$, 재생압력이 14 bar일 때의 $CO_2$ 흡수량은 본 연구의 실험조건에서 $45ml\;CO_2/g$ solution으로 가장 높은 값을 보였다. 적정을 통해 재생된 용액을 분석한 결과 재생압력이 높아질수록 암모니아 손실량은 감소하고, 재생온도가 높아질수록 암모니아 손실량이 증가하였다. 또한 암모니아 농도증가에 따라 암모니아 손실량이 비례적으로 증가하였다. Electrolyte NRTL 모델을 사용하여 Aspen Plus에 적용한 결과 실험 데이터와 거의 일치함을 보였다.

시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 - (Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System -)

  • 이광야;최경숙
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.

연동온실 곡부 제설장치의 설계인자 도출을 위한 실험적 연구 (An Experimental Study for Deriving Design Factors of Snow Removal Machines for Multi-span Greenhouse)

  • 송호성;김유용;윤남규;임성윤
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.131-140
    • /
    • 2015
  • This paper presents overall procedure by experimental study in order to deriving design factors of snow removal machine on roof of multi-span greenhouse. For the purpose of the testing, the scale model of the machine was made in the form to drive above the monorail. The test was performed in order to calculating friction coefficient of the machine and shear coefficient between sliced horizontal section of snow at constant temperature and humidity room in National Academic of Agricultural Science. As a result of the laboratory test, shear coefficient between sliced horizontal section of snow were calculated 1.60~2.37. Further investigation, we will study to derive the relationship between the real and scaled model through the field test.

사이드스커트와 보트테일을 이용한 대형화물차량의 연비개선 효과 및 온실가스 감축량 추정 (Estimation of GHG Emissions Reduction and Fuel Economy Improvement of Heavy-Duty Trucks by Using Side Skirt and Boat Tail)

  • 허철행;윤병규;김대욱
    • 한국기후변화학회지
    • /
    • 제7권2호
    • /
    • pp.177-184
    • /
    • 2016
  • Recently, the need for technology development of commercial vehicle fuel consumption has emerged. Fuel economy improvement of transport equipment and transportation efficiency, and increasing attention to the logistics cost reduction measures. Increasing attention to the logistics cost reduction measures by fuel economy improvement of transport equipment and transportation efficiency. In this study, we have installed aerodynamic reduction device (side skirt, boat tail) to 14.5 ton cargo trucks and 45 ft tractor-trailers. And the fuel consumption was compared installed before and after. Fuel economy assessment for the aerodynamic reduction value device was tested by modifying the SAE J1321 Joint TMC/SAE Fuel Consumption Test Procedure - Type II test in according domestic situation. Greenhouse gas reductions were calculated in accordance with the scenario, including fuel consumption test results. When the 14.5 ton cargo trucks has been equipped with side skirts and boat tail, it confirmed the improvement in fuel efficiency of 4.72%. One Heavy-duty truck's the annual greenhouse gas reductions value are $6.86ton\;CO_2\;eq$. And if applying the technology to more than 50% of registered 15 ton trucks, greenhouse gas reductions are calculated as $686,826ton\;CO_2\;eq./yr$.

Greenhouse Bulk 건조기에 의한 태양열이용에 관한 연구 (제2보) (Solar Energy Utilization in a Greenhouse Bulk Curing and Drying System. (II))

  • 이철환;변주섭
    • 한국연초학회지
    • /
    • 제5권1호
    • /
    • pp.79-85
    • /
    • 1983
  • The greenhouse bulk curing and drying system utilization of the direct solar energy was tested to evaluate that how much fuel could be saved for curing flue-cured tobacco at the Dae Gu Experiment Station (North latitude : $35^{\circ}$49'), in 1979-1982. The air temperature and total radiation were 19.0 to 38.5$^{\circ}C$ and 1311.0 to 1412.7 cal/$\textrm{cm}^2$/day during the 4 replicated curing test, respectively. The greenhouse bulk curing and drying system was able to cut fuel consumption by 32% compared with the conventional bulk curing barn. We could obtain almost same utilization efficiency of solar energy in 1982 compare with normal year, mainly increasing the heat receiving area.

  • PDF

시설농업의 용수 이용실태 조사분석 (A Study on tHe Utilization of Irrigation Water for Greenhouse Farming)

  • 이남호;황한철
    • 농촌계획
    • /
    • 제4권2호
    • /
    • pp.96-102
    • /
    • 1998
  • A field survey with interview was conducted to get information on the irrigation water usage for greenhouse farming. Three study regions were selected which represent geographical characteristics such as ,neighboring urban area, flat-field area, and mountainous area. Several items were investigated and analysed such as location of greenhouse, type of irrigation water resources, type of irrigation method used, way to decide intake facility size, farmers'satisfaction on intake facilities performance and water quality, and needs for water quality test. It was found that greenhouse farmers did not take an advantage of technical assistances. Proper criteria or guidelines for selection and operation of water intake facilities were not available.

  • PDF

적설하중 재하실험과 구조해석을 통한 단동 비닐하우스의 거동 연구 (An Experimental and Numerical Study on the Behavior Characteristics of Single-span Plastic Greenhouse under Snow Load)

  • 송호성;김유용;유석철;임성윤
    • 한국농공학회논문집
    • /
    • 제64권4호
    • /
    • pp.45-53
    • /
    • 2022
  • In this study, the loading test and structural analysis were performed on the snow load and the results were compared. The load plates were loaded on the roof surface of the model, and structural analysis was performed under the same conditions. The result of loading test, the maximum displacement was observed in the center of the top, and the maximum stress was observed near the bottom point. Displacement and stress were found to have a high linear relationship with the load. Comparing the structural analysis results with the loading test results, the maximum displacement difference is 4.5% and the maximum stress difference is 10.2%. It is expected that closer results can be derived if the boundary conditions for the longitudinal direction of the model are clarified during experiments and analysis.