• 제목/요약/키워드: greenhouse gases$SF_6$

검색결과 21건 처리시간 0.026초

$SF_6$ 하이드레이트 결정 성장의 특성 (Morphological study of $SF_6$ clathrate hydrate crystal)

  • 이윤석;이현주;이은경;김수민;이주동;김양도
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.711-711
    • /
    • 2009
  • Global warming has been widely recognized as a serious problem threatening the future of human beings. It is caused by the buildup in the atmosphere of greenhouse gases, such as carbon dioxide, methane, hydrofluorocarbons (HFCs), and sulfur hexafluoride (SF6). Particularly, SF6 has extremely high global warming potential compare to those of other global warming gases. One option for mitigating this greenhouse gas is the development of an effective process for capturing and separating these gases from anthropogenic sources. In general, gas hydrates can be formed under high pressure and low temperature. However, SF6 gas is known to form hydrate under relatively milder conditions. Therefore, technological and economical effects could be expected for the separation of SF6 gas from waste gas mixtures. In this study, we carried out morphological study for the SF6 hydrate crystals to understand its formation and growth mechanisms. The observations were made in high-pressure optical cell charged with liquid water and SF6 gas at constant pressure and temperature. Initially SF6 hydrate formed at the surface between gas and liquid regions, and then subsequent dendrite crystals grew at the wall above the gas/water interface. The visual observations of crystal nucleation, migration, growth and interference were reported. The detailed growth characteristics of SF6 hydrate crystals were discussed in this study.

  • PDF

폴리이서설폰 중공사 막을 이용한 $N_2/SF_6$ 투과거동에 관한 연구 (Studies on the $N_2/SF_6$ Permeation Behaviors Using the Polyethersulfone Hollow Fiber Membranes)

  • 이형근;김대훈;안영모;조항대;박종수
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.244-251
    • /
    • 2009
  • 본 연구에서는 폴리이서설폰(polyethersulfone, PES) 중공사 막을 이용하여 6대 온실가스에 속하는 육불화황($SF_6$)을 질소 중에서 분리하고자 하였다. 제막 조건에 따른 막의 구조와 성능변화를 관찰하기 위하여 다른 비용매(아세톤, 에탄올)와 에어갭(air-gap) 그리고 실리콘 코팅을 통하여 성능변화를 관찰하였으며, 전자주사현미경(scanning electron microscope)을 통하여 구조 변화를 관찰하였다. $N_2$, $SF_6$ 단일기체 투과실험에서 제조된 막의 표면 실리콘 코팅을 통하여 최고 7.64의 선택도를 나타내어 3.4배 향상된 결과를 나타내었다.

국내 마그네슘 생산공정의 온실가스 배출량 산정 및 감축방안 연구 (A Study on the Greenhouse Gas Emission and Reduction Measures of Domestic Magnesium Production Process)

  • 김경남;임진아;유경선
    • 한국기후변화학회지
    • /
    • 제5권3호
    • /
    • pp.219-230
    • /
    • 2014
  • In this study, greenhouse gas emission of magnesium industry was estimated and the reduction potential of the greenhouse gas emission was evaluated with reduction technologies. Default value of IPCC guideline was used to calculate the greenhouse gas emission and $SF_6$ alternatives were considered in reduction potential. Import of magnesium ingot was 22,806 ton in 2013, which will be expected to increase to 81,700 ton with 20% rate in 2020. Magnesium ingot was consumed to produce magnesium alloy in diecasting process. Recently, commercial production of crown magnesium and magensium plate began. Based on ingot consumption, $CO_2$ emission of domestic magnesium industry was estimated to 504,000 ton, which is about 0.79% of domestic industrial emissions. Reduction potential of diecasting process was estimated to 489,320 ton by changing SF6 to alternative gases such as HFC-134a, Novec-612. Emission factor of Tier 3 level should be developed to enhance the accuracy of greeenhouse gas emission of magnesium industry.

Research on Liquefaction Characteristics of SF6 Substitute Gases

  • Yuan, Zhikang;Tu, Youping;Wang, Cong;Qin, Sichen;Chen, Geng
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2545-2552
    • /
    • 2018
  • $SF_6$ has been widely used in high voltage power equipment, such as gas insulated switchgear (GIS) and gas insulated transmission line (GIL), because of its excellent insulation and arc extinguishing performance. However, $SF_6$ faces two environmental problems: greenhouse effect and high liquefaction temperature. Therefore, to find the $SF_6$ substitute gases has become a research hotspot in recent years. In this paper, the liquefaction characteristics of $SF_6$ substitute gases were studied. Peng-Robinson equation of state with the van der Waals mixing rule (PR-vdW model) was used to calculate the dew point temperature of the binary gas mixtures, with $SF_6$, $C_3F_8$, $c-C_4F_8$, $CF_3I$ or $C_4F_7N$ as the insulating gas and $N_2$ or $CO_2$ as the buffer gas. The sequence of the dew point temperatures of the binary gas mixtures under the same pressure and composition ratio was obtained. $SF_6/N_2$ < $SF_6/CO_2$ < $C_3F_8/N_2$ < $C_3F_8/CO_2$ < $CF_3I/N_2$ < $CF_3I/CO_2$ < $c-C_4F_8/N_2$ < $C_4F_7N/N_2$ < $c-C_4F_8/CO_2$ < $C_4F_7N/CO_2$. $SF_6/N_2$ gas mixture showed the best temperature adaptability and $C_4F_7N/CO_2$ gas mixture showed the worst temperature adaptability. Furthermore, the dew point temperatures of the $SF_6$ substitute gases at different pressures and the upper limits of the insulating gas mole fraction at $-30^{\circ}C$, $-20^{\circ}C$ and $-10^{\circ}C$ were obtained. The results would supply sufficient data support for GIS/GIL operators and researchers.

sII $SF_6+H_2$ 하이드레이트의 분자 거동 (Molecular Behavior of $SF_6+H_2$ Structure II Hydrates)

  • 박다혜;이보람;사정훈;;이건홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.122.2-122.2
    • /
    • 2011
  • Sulfur hexafluoride ($SF_6$), one of the most potent greenhouse gases, is known as a hydrate former and has been studied at the high pressure up to 1.3 GPa with gas mixtures and with aqueous surfactant. Since we regard $SF_6$ as a potential promoter molecule that can stabilize hydrate structure more effectively compare to the other promoters, further investigation is required to verify the stabilizing ability of $SF_6$ in the hydrate structure. However, the insoluble nature of $SF_6$ in water or gases hinders fine scale analyses. This work discusses the data obtained by using molecular dynamics simulations of structure II (sII) clathrate hydrates containing $SF_6$ and $H_2$. The simulations were performed using the TIP4P/Ice model for water molecule and a previously reported $SF_6$ molecular model (optimized at the pure $SF_6$ single phase system (Olivet and Vega, 2007)), and a $H_2$ molecular model (adapted from the THF+$H_2$ hydrate system (Alavi et al., 2006)). The simulations are performed to observe the stability of $SF_6$ and $H_2$ in the sII clathrate hydrate system with varying temperature and pressure conditions and occupancies of $SF_6$ and $H_2$, which cannot be easily tuned experimentally. We observe that stability of H2 enclathrated in the hydrate structure more affected by the occupancy of $SF_6$ molecules and temperature than pressure, which ranges from 1 to 100 bar.

  • PDF

혼합가스의 이물 존재시 절연 특성 연구 (A study of dielectric strength and insulating property for particle contamination Under SF6/N2 Mixture)

  • 정동훈;우수열;서경보;김진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1262-1263
    • /
    • 2011
  • Sulfur hexafluoride is the most commly used insulation gas in electrical systems. Gas insulated systems are widely used in the electric power industry for transmission and distribution of electrical energy. When $SF_6$ was first discovered, the potential application was only considered for insulation because of good dielectric properties. But the widespread use of $SF_6$ gas by electric power and other industries has led to increase concentrations of $SF_6$ gas in the atmosphere. This concern as to possible effects on global warming because $SF_6$ is a potent greenhouse gas. That's why firstly we studied uniform and nonuniform field property by mixing $SF_6$ and N2 gas. This paper presents the dielectric strength and insulating property for particle contamination under $SF_6/N_2$ mixtures. Two types of mixed gases(50% $SF_6$_50%$N_2$, 20% $SF_6$_80%$N_2$) were applied. We performed tests for the length and shape of particle. Test gas pressure is from 0.3 to 0.7 Mpa. The study was conducted to develop environment-friendly insulating material for GIS that can reduce $SF_6$ gas and make a design criteria for mixtures.

  • PDF

극저온 정제시스템의 품질관리를 위한 SF6 가스 분석방법 개선 (Improved sulfur hexafluoride(SF6) gas analysis method for quality management of cryogenic refinement system)

  • 이정은;조민;이원석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.37-41
    • /
    • 2022
  • Because sulfur hexafluoride(SF6) is classified as one of the six major greenhouse gases, SF6 handling in power plant such as recovery, purification, and reuse is considered to be important. KEPCO has focused to develop the advanced recovery and purification technology of SF6 reuse. SF6 analysis includes the on-site analyses and on-line analyzer; i.e., (1) on-site analysis has an error rate of ±0.5% and (2) on-line analysis has an error rate of ±0.1%, which is possible to adjust operating conditions and to make the work more conveniently by analyzing SF6 concentration before and after purification step. This paper presents an online analysis method in the SF6 purification and reuse system. In addition, the analysis results and quality guarantees for each section of the analysis system were presented.

An Integrated Emission Model of Greenhouse Gases to Assess Regional Climate Change

  • Moon, Yun-Seob;Oh, Sung-Nam;Hyun, Myung-Suk
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.421-422
    • /
    • 2003
  • Greenhouse gases (GHGs) such as carbon dioxide ($CO_2$), methane (CH$_4$), nitrous oxide ($N_2$O), chlorofluorocarbons (CFCs), sulphur hexafluoride (SF$_{6}$), together with water vapour ($H_2O$) and ozone play an important role in determining the earth's climate. The primary cause of the enhancement of GHGs is the global use of fossil fuels to generate heat, power, and electricity for a growing world population, as well as the changes in the land use, especially for agriculture. In addition, biomass buring and biofuel emissions play major roles in the GHG emissions in the Asian region because they produce large amounts of carbon monoxide (CO), nonmethane volatile organic compounds(NMVOC), black carbon(BC) and other gases. (omitted)d)

  • PDF

폴리이미드 중공사 막을 이용한 N2/SF6 혼합기체 분리에 관한 연구 (Study on the Separation of N2/SF6 Mixture Gas Using Polyimide Hollow Fiber Membrane)

  • 김대훈;김광림;조항대;박종수;이형근
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.660-667
    • /
    • 2010
  • 본 연구에서는 고분자 막을 이용하여 6대 온실가스 중 가장 높은 지구온난화지수를 갖는 육불화황(sulfur hexafluoride, $SF_6$)의 회수에 관한 연구를 실시하였다. 막 소재로 이미드 계열의 Matrimid 5218 소재를 건/습식 상전이 법을 이용하여 중공사 형태로 제조하고, 표면 실리콘 코팅 후 모듈을 제조하였다. 제조된 중공사 막은 전자주사현미경 관찰을 통하여 외부 표면에 치밀한 선택층과 망상구조의 하부로 이루어진 비대칭 구조를 확인하였다. 막의 기체투과 특성 확인을 위하여 온도와 압력 변화에 따른 $N_2$, $SF_6$ 단일 기체투과를 실시하였으며, 운전 조건에 따라서 0.78~1.36 GPU의 $N_2$ 투과도와 2.44-5.08의 $N_2/SF_6$ 선택도를 나타냈었다. 제조된 모듈의 혼합기체 분리거동 관찰을 위하여 10 vol.% $SF_6$ 농도를 갖는 $N_2/SF_6$ 혼합기체를 이용하여 온도, 압력, retentate 유량을 달리하여 실시하였으며, 실험을 통하여 압력과 온도 증가 및 retentate 유량 감소에 따라서 회수된 가스 중에 $SF_6$의 농도는 증가되어 최고 37.5 vol.%를 나타낸 반면 회수율은 감소되는 경향을 나타내었으며, 동일한 온도와 압력에서 retentate 유량 증가에 따라서 $SF_6$ 농도는 감소되는 반면 회수율이 증가하여 최고 89%의 회수율을 나타내었다.

Evaluation of a Prototype SF6 Purification System for Commercialization

  • Seo, Hai-Kyung;Lee, Jeong Eun;Kim, Kwang Sin;Kim, Kyeongsook
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권1호
    • /
    • pp.53-58
    • /
    • 2020
  • Korea Electric Power Corporation (KEPCO) uses large amount of SF6, one of the potent greenhouse gases, in electric equipment for electrical insulation. KEPCO is developing SF6 recovery and purification technology to minimize the release of SF6 into the environment, to secure certified emission reduction, and to save purchase cost of new SF6 by reusing the refined SF6. A prototype SF6 purification system using cryogenic solidification technology has been built in demonstration scale. To evaluate the feasibility of the commercialization, the system has been operated to purify large amount of used SF6 in a long-term operation and the performance has been economically evaluated. The system was stable enough for commercial operation such that it was able to purify 5.4 tons of used SF6 from power transmission equipment in 2-month operation. Over 99% of the SF6 was recovered from the used gas and the purity of the purified gas was over 99.7 vol%. The operation cost, which is the cost of refrigerant (liquid nitrogen), electricity and labor, per kilogram of purified SF6 was 6,526 KRW. Considering the price of new SF6 in Korea is about 15,000 KRW per kilogram this year, about 56% of the purchase cost can be saved.