• 제목/요약/키워드: greenhouse environment

검색결과 1,675건 처리시간 0.027초

바이오에너지 (바이오가스, 바이오매스) 기술의 온실가스 감축산정: 국내를 대상으로 (Estimation of Greenhouse Gas (GHG) Reductions from Bioenergy (Biogas, Biomass): A Case Study of South Korea)

  • 정재형;김기만
    • 한국대기환경학회지
    • /
    • 제33권4호
    • /
    • pp.393-402
    • /
    • 2017
  • In this study, greenhouse gas (GHG) reductions from bioenergy (biogas, biomass) have been estimated in Korea, 2015. This study for construction of reduction inventories as direct and indirect reduction sources was derived from IPCC 2006 guidelines for national greenhouse gas inventories, guidelines for local government greenhouse inventories published in 2016, also purchased electricity and steam indirect emission factors obtained from KPX, GIR respectively. As a result, the annual GHG reductions were estimated as $1,860,000tonCO_{2eq}$ accounting for 76.8% of direct reduction (scope 1) and 23.2% of indirect reduction (scope 2). Estimation of individual greenhouse gases (GHGs) from biogas appeared that $CO_2$, $CH_4$, $N_2O$ were $90,000tonCO_2$ (5.5%), $55,000tonCH_4$ (94.5%), $0.3tonN_2O$ (0.004%), respectively. In addition, biomass was $250,000tonCO_2$ (107%), $-300tonCH_4$ (-3.2%), $-33tonN_2O$ (-3.9%). For understanding the values of estimation method levels, field data (this study) appeared to be approximately 85.47% compared to installed capacity. In details, biogas and biomass resulting from field data showed to be 76%, 74% compared to installed capacity, respectively. In the comparison of this study and CDM project with GHG reduction unit per year installed capacity, this study showed as 42% level versus CDM project. Scenario analysis of GHG reductions potential from bioenergy was analyzed that generation efficiency, availability and cumulative distribution were significantly effective on reducing GHG.

열펌프-잠열축열 시스템 온실에서 토양의 열저장 및 방열 특성 (Thermal Energy Storage and Release Characteristics of the Soil in the Greenhouse Equipped with Heat Pump and Latent Heat Storage System)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제27권1호
    • /
    • pp.39-44
    • /
    • 2002
  • In order to obtain the information of bio-environment control, the thermal characteristics of soil in the greenhouse heated by the heat pump and latent heat storage system were experimentally analyzed. The experimental systems were composed of the greenhouse with a heat pump and a latent heat storage system (system I), the greenhouse with a heat pump (system II), the greenhouse with a latent heat storage system (system III), and the greenhouse without auxiliary heating system (system IV). The thermal characteristics experimentally analyzed in each system were temperature of soil layers, soil heat storage and release, soil heat capacity and soil heat storage ratio. The results could be summarized as follows. 1. Time to reach the highest temperature at 20cm deep in soil layers of the crop routs in case of system I was shown to be delayed by 6 hours in comparison to the time of the highest temperature at the soil surface. 2. In the clear winter days, the stored heat capacity values fur the system I and the system II were shown to be 22.3% and 11.0% higher than the released heat capacity respectively, and the stored heat capacity values for the system III and the system IV were shown to be 6.2% and 29.6% lower than the released heat capacity respectively This confirms that the system I provided the best heat storage effect. j. The heat quantity values stored or released were shown to be highest at 5 cm depth of soil layers. And it was reduced with increasing of depth of soil layers until 20 cm and was not changed under the soil layer of 20 cm depth. 4. The heat absorption rates of soil, the ratio between supplied and stored heat energy, fur both the system I and system II were lower than 23%.

퇴비발효온실의 환경조건이 토마토의 생육에 미치는 영향 (Environmental Effects on the Growth and Development of Tomato in Composting Greenhouse)

  • 양원모;홍지형;박금주;손보균
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.202-209
    • /
    • 1996
  • 본 연구는 온실내에서 퇴비발효 과정중에 발생하는 암모니아가스의 동태와 퇴비발효에 수반되는 환경의 변화가 토마토의 생육에 어떠한 영향을 미치는지 구명하고자 관행온실과 퇴비발효온실의 환경변화를 추적하면서 토마토의 생장과 수량 및 과일의 품질을 비교하였다. 1. 온도는 난방기에 의해 일정온도로 유지되도록 설정하였고 주간에는 $25^{\circ}C$이상에서 환기를 하였기 때문에 두 온실간의 차이가 없었다. 2. 퇴비발효온실 지중 l0cm 깊이의 지온은 관행온실보다 주간 약 7$^{\circ}C$, 야간 약 1$0^{\circ}C$ 높았으며, 지중 30cm 깊이의 퇴비발효온실의 지온은 관행온실의 지온보다 약 10-15$^{\circ}C$ 높았다. 3. 발효시작후 2, 3, 4, 5, 및 6일째의 암모니아가스 휘산농도는 각각 5.4, 13.3, 114, 114.7 및 117.3ppm으로 상승하였다. 발효후 7, 8, 9, 10, 11, 12, 13 및 14일 째에는 각각 79.3, 41, 41, 54.7 10.7, 20, 82 및 27ppm으로 발효 7일째부터 낮아져서 8일 이후에 현저히 감소하였다. 발효 16일째에는 15.7ppm으로 낮아졌으나 작물에 따라서는 8ppm에서도 암모니아가스 장해를 받을 수 있으므로 본 실험과 같은 조건으로 발효를 시키는 퇴비발효온실에서의 작물 정식은 발효시작 후 약 3주 이후가 되어야 할 것으로 판단되었다. 4. 관행온실내의 탄산가스 농도는 450ppm 내외인데 비해 퇴비발효온실내의 농도는 발효 후 1개월까지는 약 2500ppm 이상까지 높아졌으며 발효가 시작된 2개월까지는 무환기시 약 1000-1500ppm을 유지하였으며 2개월 이후부터 4개월까지는 약 700-1000ppm이 유지되었다. 5. 주근장을 제외하고는 전체적으로 관행온실보다 퇴비발효온실에서의 토마토 생육이 양호하였다. 특히 경경의 경우 정식 1개월 후부터 그 차이가 뚜렷하게 나타났으며 2개월 후에는 직경 약 1cm의 차이가 나타났다. 엽, 경, 근의 생체중 및 건물중도 생육이 진전됨에 따라 퇴비발효온실에서 현저히 증가하였다. 방울토마토의 경우 개화수와 착과수는 퇴비발효온실에서 높았으며 과중은 거의 비슷하거나 낮았다. 그러나 일반토마토의 경우는 모든 항목이 퇴비발효온실에서 높게 나타나 그 효과가 현저하였다. 퇴비발효온실 방울토마토의 총수확과수와 수확총중량은 생육이 진전됨에 따라 관행온실보다 많아졌으며 일반토마토에서는 그 경향이 현저하였다. 6. 퇴비발효온실에서 재배된 방울토마토의 평균당도는 8.5-9.2인 반면 관행온실에서 재배된 방울토마토의 당도는 7.0-9.0으로 나타났으며 일반토마토의 경우 퇴비발효온실에서의 당도가 6.5-7.5인 반면 관행온실에서는 5.9로 나타나 퇴비발효온실 토마토의 당도가 약 1도 정도 높아졌다.

  • PDF

플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가 (Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses)

  • 이현우;김영식;심상연;이종원;소레이멘디옵
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.270-278
    • /
    • 2013
  • 본 연구는 우리나라 상업용 온실의 보온성능 및 광투과 성능을 개선할 수 있는 피복방식을 결정하는데 필요한 자료를 제공하기 위하여 토마토 재배용 실험온실의 세 가지 피복방식에 대한 보온효과 및 광투과 특성을 평가하였으며 결과를 요약하면 다음과 같다. 공기주입 이중피복온실과 관행 이중피복온실의 관류열손실량이 거의 비슷한 것으로 나타났으나 외부기온이 비슷할 때 피복재와 보온커튼 사이의 온도가 공기주입 이중피복온실이 더 낮게 나타난 것은 공기주입 이중피복온실의 경우 나비식 천창의 틈새로 인한 환기전열손실이 크기 때문인 것으로 판단된다. 따라서 공기주입 이중피복온실에서 나비식 천창을 사용할 경우 틈새 환기전열손실을 줄일 수 있는 대책이 수립되어야 할 것으로 판단된다. 일중피복 온실과 관행이중피복온실의 관류열전달계수에 대한 온실 실험결과와 모형실험결과를 비교한 결과 모두 비슷한 값을 나타내었다. 이러한 결과는 측정된 관류열전달계수가 타당성 있는 값임을 보여주는 것이며 향후 온실의 난방설계시 직접 활용할 수 있을 것으로 기대된다. 공기주입 이중피복온실이 비록 일중피복온실보다는 광투과율이 낮으나 동일한 이중피복온실인 관행이중피복온실보다 광투과율이 높기 때문에 보온을 위해서 이중피복을 설치할 경우에 광투과율을 확보하기 위해서는 공기주입 이중피복방식을 채택하는 것이 바람직할 것으로 판단된다. 공기주입 이중피복온실에 비해 일중피복온실의 피복재 내부표면에서 발생하는 결로량이 큰 이유는 일중피복온실의 피복재 내부표면온도가 훨씬 낮기 때문에 피복재에서의 포화습도가 작아져 내부공기의 절대습도와의 차이가 증가하기 때문인 것으로 판단된다.

시설내 온도분포 균일화를 위한 온풍난방기용 2중 덕트개발 (Improving the Distribution of Temperature by a Double Air Duct in the Air-Heated Plastic Greenhouse)

  • 김태영;김기덕;조일환;남은영;남윤일;우영회;문보흠
    • 생물환경조절학회지
    • /
    • 제13권3호
    • /
    • pp.162-166
    • /
    • 2004
  • 동절기 시설내 온도분포를 균일하게 하기 위하여 온풍난방기용 이중덕트를 개발하고자 본 연구를 수행한 결과 관행 온풍덕트의 각 지점간 토출구 송풍온도 차이가 13 ~ $14^{\circ}C$인데 비하여 개선형 덕트인 이중덕트의 토출구 송풍온도 차이가 3 ~ $4^{\circ}C$로 나타나 각 지점간의 온도 불균형이 크게 개선되었으며 이중덕트의 각지점간의 생육정도도 관행덕트에 비해 크게 향상 된 것으로 나타났다. 수량에 있어서도 관행덕트를 사용한 재배시설에서 10a당 3,924kg에 비하여 이중덕트를 사용한 재배가 4,616kg으로 약 17%가 증수되었다. 그리고 반촉성 재배기간 동안 난방에 소요된 연료소모량은 관행덕트가 3,724ι/10a인데 비하여 이중덕트가 3,233ι 13%의 연료절감효과가 있다.

인터넷 온실경영관리시스템 개발에 관한 연구 (A Study on the Development of Greenhouse Management System Based on Internet)

  • 심근섭;강정옥;이희주
    • 농촌지도와개발
    • /
    • 제11권1호
    • /
    • pp.191-207
    • /
    • 2004
  • This study was focused on the development of greenhouse management and environmental control system using internet. The essence of this system were remote automatic control unit connected with greenhouse environmental control according to the growth stages of crops, The specific objectives of the study were; 1) to analyze need of greenhouse environmental remote control system, 2) to investigate the important functions related to greenhouse management program, 3) to explore the possibility of diffusing the system using internet.The study was carried out through review of related literature and need assessment from the research and extension workers in charge of greenhouse management using questionnaire survey, interview and field study. The results of the study were summarized as fallows: 1) About 89% of respondents responded positively on the need to establish automatic control system using internet. 2) The greenhouse management and environmental control system using internet was possible to control the greenhouse in remote, automatic, and simultaneous manner, and additionally by cellular phone in emergent situation. 3) The system was possible to precisely control the greenhouse environment, and it was able to connect the environmental control data with information on growth of crops. 4) By networking the farmer, extension educator of agricultural technology center and researcher, web based farm consulting was possible through the system. Based on the results of the study recommendations were suggested as follows: 1) Thorough spot inspections and field trials should be performed before the diffusion of this system. 2) The costs of the system installation and maintenance should be moderate. 3) The operation of the system should be simple and easy for tamers to adopt. 4) National support should be made to build better internet infrastructure in rural areas.

  • PDF

하절기 온실의 활용실태 및 몇 가지 고온극복 방법별 열환경 분석 (Actual Utilization and Thermal Environment of Greenhouses According to Several Cooling Methods during Summer Season)

  • 남상운
    • 생물환경조절학회지
    • /
    • 제9권1호
    • /
    • pp.1-10
    • /
    • 2000
  • 온실의 경제적 고온극복 방안의 방향 설정을 위한 기초 자료를 얻기 위하여 비닐하우스 96농가, 유리온실 75농가를 대상으로 하절기 온실의 활용실태를 조사한 결과 유리온실 18.7%, 비닐하우스 24.0%, 전체 21.6%의 시설재배 농가가 휴경하고 있었으며, 나머지 경우도 매우 열악한 환경 하에서 재배가 이루어지고 있었고, 고온 극복을 위한 저비용 기술의 개발에 관한 요구가 매우 높았다. 냉방 및 보조냉방 처리별 온실의 열환경을 비교 측정한 결과 자연환기만으로는 74.8%, 지붕살수시 58.2%가 35$^{\circ}C$를 초과하여 작물재배가 곤란한 것으로 나타났다 환기와 차광을 병행할 경우에는 26.9%만 35$^{\circ}C$를 초과하는 것으로 나타나 약간만 개선하면 어느 정도의 고온극복은 가능할 것으로 판단되었다. 차광과 증발냉각의 일종인 에어쿨팬의 가동으로 자연환기 온실에 비하여 3.8~4.2$^{\circ}C$의 냉방효과를 보였으며, 온실내의 기온을 대부분 35$^{\circ}C$ 이내로 유지하는 것이 가능한 것으로 나타났다. 증발냉각시스템의 도입으로 고온극복이 가능하지만 확대보급을 위해서는 비용절감 및 체계화기술 개발이 과제로 남아 있다. 한편, 차광과 고효율의 환기로 어느 정도의 고온극복이 가능하므로 비교적 시설비 투자가 적은 온실에 대하여는 환기시스템 및 차광방법 개선 등의 연구를 통한 경제적인 고온극복 방안 설정이 필요할 것으로 판단되었다.

  • PDF

기후변화와 대기환경의 통합적 관리에 대한 고찰 (A Review of the Integrated Strategy for Climate Change and Air Pollution Management)

  • 송창근;이석조;윤종수
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.805-818
    • /
    • 2011
  • The unequivocal risk of climate change, the weakness of energy security, and the problem of air quality will be possibly accelerated by the same reason, the enhanced fossil fuel dependancy in the future. It is obvious that greenhouse gases and air pollutants are mainly emitted from same sources. Moreover, greenhouse gases and air pollutants have their adversed impacts on same socio-economical, and environmental sectors. With these regards, several but limited studies have emphasized on the importance of the integrated management of climate change and air quality problem. In this study, we address the current trend of energy consumption and the change of air quality condition. Also the related policies are checked out in order to reduce emissions of greenhouse gases and air pollutants in Korea. By surveying previous studies, it is shown that the cost of climate change actions can be reduced by air quality co-benefits and vis-a-versa. Also the integrated strategy for climate change and air quality is introduced in term of cost-effectiveness and co-benefit.

An Analysis on the Ancillary Benefit of Greenhouse Gases Reduction in Korea

  • Yanghoon Song;Han, Wha-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E1호
    • /
    • pp.41-50
    • /
    • 2003
  • Greenhouse gases (GHG) could lead to global warming, which may bring about various disturbances to global ecosystem. Other than primary benefits that are too extensive, the ancillary benefit from GHG reduction has been estimated to provide justification for national actions. Five scenarios for 5 to 40% reduction of GHG were evaluated for the benefit/cost efficiency, using the cost estimates from a previous study. Their benefits were also estimated using a European model. As a result of this study, it can be concluded that lower reduction scenarios (5∼10%) seem to be more efficient than higher reduction scenarios (30∼40%).

Variation of CO2 Concentration in Greenhouses and Effects on Growth and Yield in Alstroemeria with CO2 Supplementation

  • Seonjin Lee;WonSuk Sung;Donguk Park;Pilsoo Jeong
    • 한국환경농학회지
    • /
    • 제42권3호
    • /
    • pp.231-238
    • /
    • 2023
  • We analyzed the variations in the CO2 concentration and temperature between a CO2-enriched and control greenhouse. We cultivated Alstroemeria 'Hanhera' in the two greenhouses and assessed the growth parameters (stem length, stem thickness, and the number of flowers) and yield. The CO2-enriched greenhouse had a CO2 generator that produced CO2 at rate of 0.36 kg/h and its windows were programmed to open when the temperature exceeded 20℃ and close when it dropped below 15℃. The control greenhouse had no additional CO2 supplementation, and its windows were programmed to open when the temperature exceeded 20℃ and close at approximately 17:00. In the morning, CO2 concentration remained above 500 ppm in the CO2-enriched greenhouse, which was higher than that in the control greenhouse (approximately 370 ppm). The ventilation effect only through the side windows to reduce the temperature in both greenhouses did not appear dynamically. CO2 supplementation promoted plant growth, resulting in a significant increase in plant yield of over 60% compared to that of the control greenhouse. Our findings suggest that elevated CO2 concentration in the morning can significantly promote the growth and development of Alstroemeria during the winter.