• Title/Summary/Keyword: greenhouse design

Search Result 463, Processing Time 0.026 seconds

Improving Assessment of External Environment for Green Standard for Energy & Environmental Design Certification according to Climate Change (기후변화에 따른 녹색건축인증제도의 외부환경 평가항목 개선방향 연구)

  • Kim, Ji-Hyeon;Kwon, Hyuck-Sam;Kim, Jung-Gon;Song, Ok-Hee
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.171-180
    • /
    • 2017
  • In 1990s, as the extreme weather events according to the global warming climate change are occurred frequently all around the world and the scale of the damage increases, the developed countries are promoting various policies for reducing greenhouse gas emissions setting the goal of greenhouse gas reduction with the level of State and local government. Especially for the greenhouse gas reduction of buildings and the inducement of eco-friendly design, the green certification system is strengthened with the assessment of energy and greenhouse management, and recently, according to the policy change of climate and energy, the certification system expanded from the buildings to the level of city and district is piloted. So this research is to understand the main contents and the assessment system of domestic green building certification system implemented in March 2013 in response to the policy change of climate and energy and to suggest the basic data for the improvement of present domestic greenhouse certification standard through the analysis of actual certification and the main case analysis of international green certification system. Recently in developed countries, in 1990s, for the reduction of building's greenhouse gas emission and the inducement of eco-friendly design, from the building of LEED, BREEAM, DGNB to the level of city and district such as LEED Neighborhood Development, BREEAM Communities, DGNB Stadtquartiere, the system is expanded and piloted. On the contrary, as for the domestic standard of green building certification system, the distribution ratio according to the assessment items in each category consists of the assessment system based on the buildings, and just the simple adjustment of some items and the improvement of weighted value are performed. Actually, as a result of selecting the 30 districts of apartment housing with the most certification performance by use among the 49 buildings certified by Institute of Land & Housing from December 2014 to July 2016 and analyzing the assessment score, the certification level is determined by the sectors of high distribution like indoor environment and energy not by the ineffective sector of external environment with low distribution so this system has a limitation to perform the practical means for the policy change of climate and energy. Thus for the national green building certification standards, the assessment system in the sector of external environment is to complemented and furthermore, reflecting domestic reality, through the introduction of certification system and the assessment system with the level of city and district, this system should be improved to meet the international certification standard.

Analysis of Light Environments in Reclaimed Land and Estimation of Spatial Light Distributions in Greenhouse by 3-D Model (간척지 광환경 특성 분석 및 3-D 모델을 통한 온실 내 공간적 광분포 예측)

  • Lee, June Woo;Shin, Jong Hwa;Kim, Jee Hoon;Park, Hyun Woo;Yu, In Ho;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.303-308
    • /
    • 2014
  • Reclaimed lands, expected as high-tech export horticultural complex, have unusual light environments due to sea fog. For adequate greenhouse design at reclaimed land, spatial light distributions in greenhouse should be required considering diffusive and direct lights. The objectives of this study were to analyze light environments and estimate spatial light distributions in greenhouse at reclaimed land by 3D greenhouse models. Total and diffusive lights were compared between reclaimed land and inland. For verification of the 3D greenhouse models, spatial light distributions and measured light intensities in greenhouse were compared with the estimated ones. Light environments at reclaimed land showed a higher diffusive irradiation than at inland, especially near sunrise and sunset. The estimated spatial light distributions in greenhouse showed good agreements with the measured ones. By using this method, we could estimate the average light intensity with time and spatial light distributions in greenhouse at specific outside light conditions. This result will be useful for analysis of light environments but also estimation of crop light inception in greenhouse at reclaimed land.

Effect of the Member Joint on Structural Performance of an Arch-type Multi-span Greenhouse: A Full-scale Experimental and Numerical Study (부재 접합부가 아치형 연동온실의 구조 성능에 미치는 영향: 실대형 실험적 및 해석적 연구)

  • Choi, Man-kwon;Ryu, Hee-ryong;Cho, Myeong-whan;Yu, In-ho
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.402-410
    • /
    • 2017
  • The effect of the steel pipe member joint on the design performance of a plastic multi-span greenhouse was analysed through the comparing full-scale experiment and numerical analysis. The design performance of the greenhouse is generally evaluated through numerical analysis, but it is rare to consider the characteristics of the connections or joints of the members. In this study, the effect of the column-gutter beam-rafter-wind break wall joint on the design performance of the whole structure of a plastic multi-span greenhouse was analysed. The numerical results with assuming that the member joint are rigid condition were compared with the full-scale load test results using member joints used in the field. The stiffness of the entire structure was compared using the load-displacement relationship and the change of the load sharing ratio that the main members such as column, rafters, and wind break wall was analysed. The results of the load test were about 40% larger than the numerical result and the member stress was more than twice as large as those of the loaded columns. In order to increase the reliability of the design performance of the greenhouse, it is necessary to develop a numerical analysis model which can consider the characteristics of various joints.

The Experiment for Performance Evaluation of Column-rafter-purlin Connections of an Arch-type Plastic Multi-span Greenhouse (플라스틱 연동온실 기둥-서까래-도리 접합부의 성능 평가 실험)

  • Choi, Man-kwon;Ryu, Hee-ryong;Cho, Myeong-whan;Yu, In-ho;Kim, Seung-yu
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.473-479
    • /
    • 2020
  • In this study, the structural experiment was conducted with two types of specimens to investigate the mechanical behavior of the column-rafter-purlin connection of an arch-type greenhouse under monotonic loading. Based on the experimental results, the flexural performance was analyzed for two types of connections, and connection classification was attempted. Type B showed 77% of flexural performance compared to Type A, and both types showed that the rigidity and flexural strength did not reach the level of the full rigid. The behavior of the column-rafter-purlin connection was dominated by local buckling due to deformation of the weld and fasteners. As a result of connection classification by AISC standard, both Type A and B connections showed a result that did not meet the rigid connection performance assumed during design, and were classified as simple connection. Therefore, the connection performance evaluation and classification results show that the greenhouse design should be made in consideration of connection performance and in order to design a reliable greenhouse structure, a study on establishing clear design standards for the greenhouse connection is necessary.

Empirical Analysis on the Cooling Load and Evaporation Efficiency of Fogging System in Greenhouses (온실의 냉방부하 및 포그시스템의 증발효율 실험분석)

  • Nam, Sang-Woon;Seo, Dong-Uk;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • In order to develop the cooling load estimation method in the greenhouse, the cooling load calculation formula based on the heat balance method was constructed and verified by the actual cooling load measured in the fog cooling greenhouse. To examine the ventilation heat transfer in the cooling load calculation formula, we measured ventilation rates in the experimental greenhouse which a cooling system was not operated. The ventilation heat transfer by a heat balance method showed a relatively good agreement. Evaporation efficiencies of the two-fluid fogging system were a range of 0.3 to 0.94, average 0.67, and it showed that they increased as the ventilation rate increased. We measured thermal environments in a fog cooling greenhouse, and calculated cooling load by heat balance equation. Also we calculated evaporative cooling energy by measuring the sprayed amount in the fogging system. And by comparing those two results, we could verify that the calculated and the measured cooling load showed a relatively similar trend. When the cooling load was low, the measured value was slightly larger than calculated, when the cooling load was high, it has been found to be smaller than calculated. In designing the greenhouse cooling system, the capacity of cooling equipment is determined by the maximum cooling load. We have to consider the safety factor when installed capacity is estimated, so a cooling load calculation method presented in this study could be applied to the greenhouse environmental design.

Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method (CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석)

  • Nam Sang Woon;Giacomelli Gene A.;Kim Kee Sung;Sabeh Nadia
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • Evaporative cooling pad system is one of the main cooling methods in greenhouses and its efficiency is very high. However, it has some disadvantages such as greenhouse temperature distributions are not uniform and installation cost is expensive. In this study, a CFD simulation model f3r predicting the air temperature distribution in the fan and fad cooling greenhouse was developed. The model was calibrated and validated against experimental data and a good fit was obtained. The influence of different outside wind, fan and pad height, ventilation rate, shading, and greenhouse length, were then examined. In order to reduce the internal temperature gradients, it is desired that the prevail wind direction and the fan and pad heights are considered. The simulation indicates that high ventilation rates and shading contribute to reduce the temperature gradients in the fan and pad cooling greenhouse. In order to maintain the desired greenhouse temperature, the pad-to-fan distance should be restricted according to the design climate conditions, shading and ventilation rates. The developed CFD model can be a useful tool to evaluate and design the fan and pad systems in the greenhouses with various configurations.

The Development of Wide-span Plastic Film Greenhouse for Strawberry Seedling Cultivation (딸기 육묘용 광폭 플라스틱 필름 온실 개발)

  • Man Kwon Choi;Myeong Whan Cho;Hyun Ho Shin;Ki Bum Kweon
    • Journal of Bio-Environment Control
    • /
    • v.32 no.4
    • /
    • pp.442-448
    • /
    • 2023
  • This study aimed to develop an optimal greenhouse model for strawberry seedling during the summer high-temperature period based on the results of field surveys. We conducted a survey on the structure types of 46 strawberry seedling farms nationwide, including width, ridge height, eaves height, ventilation method, seedling bed width, and spacing. Based on the survey results, we derived the optimal greenhouse model by considering various factors. The greenhouse width was set at 14 meters to maximize the efficiency of seedling beds and overall space. The height was determined at 2 meters, taking into account ventilation during the summer season. To reduce stress on the supporting structure due to snow loads, we established a reinforcement installation angle of 50 degrees. We analyzed two different models that use support beams with dimensions of φ48.1×2.1t and φ59.9×3.2t, respectively, to ensure structural safety against meteorological disasters, considering regional design wind speeds and snow accumulation. We utilized these developed greenhouse model to conduct strawberry seedling experiments, resulting in a high survival rate of average 93.2%. These findings confirm the usefulness of the strawberry seedling greenhouse in improving the seedling environment and enhancing overall efficiency.

Peak Cooling and Heating Load and Energy Simulation Study for a Special Greenhouse Facility (유리 온실 시설의 연간 냉난방 부하 및 에너지 시뮬레이션에 관한 연구)

  • Jang, Jea-Chul;Kang, Eun-Chul;Lee, Euy-Joon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.72-76
    • /
    • 2009
  • A peak cooling and heating load($kW/m^2$) and annual energy($kWh/m^2{\cdot}yr$) have been simulated for a special greenhouse located near Seoul. The special facility was designed for living plant and butterfly with many visitors. The design conditions for the facility have been discussed with the designer and simulated with the weather and building conditions. The load and energy simulation was done by TRNSYS 15 based on IPMVP 4.4.2.'s simulation requirement. The results have been shown in terms of area($kW/m^2$) and volume load and energy index($kWh/m^2{\cdot}yr$). Considering the higher height of the facility, The results came out reasonably comparing the index of a typical commercial building signed as $462kWh/m^2{\cdot}yr$.

  • PDF

A study on the UI design and program development for integrated management of carbon data in city (도시 탄소데이터 통합관리를 위한 프로그램 설계 방안 및 UI 연구)

  • Park, Jun-Hyoung;Kim, Seong-Sik;Kim, Jong-Woo;Choi, Guei-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.108-117
    • /
    • 2013
  • Studies on the regulation and measurement of greenhouse gases(GHGs) emissions have been carrying out for global wanning. In order to reduce greenhouse gas emissions, many countries have been promoting the Emissions Trading System and projects of the Joint Implementation(JI) and Clean Development Mechanism(CDM). These country's GHG emissions have been measured calculation criteria based on the Intergovernmental Panel on Climate Change(IPCC) Guidelines. In order to respond to GHGs regulation, in each country, it is planing to build a Low-Carbon City. The system has been developed for calculating GHGs emissions from companies and institutions in their respective countries. However, the system can monitor the GHGs per city, has not been developed. In this paper, it is studied to design the User Interface and to develop integrated monitoring program for Low-carbon city. This program will make possible monitoring and management, statistics, and reports written by using each data in units of cities.