• Title/Summary/Keyword: green laboratories

Search Result 64, Processing Time 0.027 seconds

Case Studies on Space Zoning and Passive Façade Strategies for Green Laboratories

  • Kim, Jinho
    • Architectural research
    • /
    • v.22 no.2
    • /
    • pp.41-52
    • /
    • 2020
  • Laboratory buildings with specialized equipment and ventilation systems pose challenges in terms of efficient energy use and initial construction costs. Additionally, lab spaces should have flexible and efficient layouts and provide a comfortable indoor research environment. Therefore, this study aims to identify the correlation between the facade of a building and its interior layout from case studies of energy-efficient research labs and to propose passive energy design strategies for the establishment of an optimal research environment. The case studies in this paper were selected from the American Institute of Architects Committee on the Environment Top Ten Projects and Leadership in Energy and Environmental Design (LEED) certified research lab projects. In this paper, the passive design strategies of space zoning, façade design devices to control heating and cooling loads were analyzed. Additionally, the relationships between these strategies and the interior lab layouts, lab support spaces, offices, and circulation areas were examined. The following four conclusions were drawn from the analysis of various cases: 1) space zoning for grouping areas with similar energy requirements is performed to concentrate similar heating and cooling demands to simplify the HVAC loads. 2) Public areas such as corridor, atrium, or courtyard can serve as buffer zones that employ passive solar design to minimize the mechanical energy load. 3) A balanced window-to-wall ratio (WWR), exterior shading devices, and natural ventilation systems are applied according to the space programming energy requirements to minimize the dependence on mechanical service. 4) Lastly, typical laboratory space zoning categories can be revised, reversed, and even reconfigured to minimize the energy load and adjust to the site context. This study can provide deep insights into various design strategies employed for construction of green laboratories along with intuitive arrangement of various building components such as laboratory spaces, lab support spaces, office spaces, and common public areas. The key findings of this study can contribute towards creating improved designs of laboratory facilities with reduced carbon footprint and greenhouse emissions.

Performance evaluation of Surface Temperature Reduction by using Green infrastructure Surface Temperature Measurement for Urban Heat Island Mitigation (도시열섬완화를 위한 그린인프라시설의 표면온도 저감 성능평가)

  • Ko, Jong Hwan;Bae, Woo Bin;Park, Dae Geun;Jung, Won Kyong;Park, Yun mi;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.4
    • /
    • pp.257-263
    • /
    • 2018
  • This study is to develop a GSTM (Green infrastructure Surface Temperature Measurment) equipment for reducing the surface temperature of GI by using LID Method. The tests were conducted including GI products such as Greening block, Pervious Block, Soil Block and so on. The GSTM equipment developed by considering the literature surveys are characterized as follows. The non-contact infrared temperature sensor was used to measure the surface temperature, and it was improved to measure the overall average temperature including the center and the corner temperature of the specimen. The developed GSTM equipment was used to compare performance of asphalt and GI products. As a result, the Greening Block show a high difference of $18.4^{\circ}C$ and it contributes to the decrease of surface temperature.

A Study of Carry Over Contamination in Chematology (이월오염에 대한 연구)

  • Chang, Sang-Wu;Kim, Nam-Yong;Lyu, Jae-Gi;Jung, Dong-Jin;Kim, Gi-You;Park, Yong-Won;Chu, Kyung-Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.178-184
    • /
    • 2005
  • Carry over contamination has been reduced in some systems by flushing the internal and external surfaces of the sample probe with copious amount of diluent. It between specimens should be kept as small as possible. A built-in, continuous-flow wash reservoir, which allows the simultaneous washing of the interior and exterior of the syringe needles, addresses this issue. In addition, residual contamination can further be prevented through the use of efficient needle rinsing procedures. In discrete systems with disposable reaction vessels and measuring cuvets, any carry over is entirely caused by the pipetting system. In analyzers with reuseable cuvets or flow cells, carry over may arise at every point through which high samples pass sequentially. Therefore, disposable sample probe tips can eliminate both the contamination of one sample by another inside the probe and the carry over of in specimen into the specimen in the cup. The results of the applicative carry over experiment studied on 21 items for total protein (TP), albumin (ALB), total bilirubin (TB), alkaline phosphatase (ALP), aspratate aminotranferase (AST), alanine aminotranferase (ALT), gamma glutamyl transferase (GGT), creatinine kinase (CK), lactic dehydrogenase (LD), creatnine (CRE), blood urea nitrogen (BUN), uric acid (UA), total cholesterol (TC), triglyceride (TG), glucose (GLU), amylase (AMY), calcium (CA), inorganic phosphorus (IP), sodium (Na), potassium (K), chloride (CL) tests in chematology were as follows. Evaluation of process performance less than 1% in all tests was very good, but a percentage of ALB, TP, TB, ALP, CRE, UA, TC, GLU, AMY, IP, K, Na, and CL was 0%, implying no carry over. Other tests were ALT(-0.08%), GGT(-0.09%), CK(0.08%), LD(0.06%), BUN(0.12%), TG (-0.06%), and CA(0.89%).

  • PDF

A Study of Reportable Range Setting through Concentrated Control Sample (약물검사에서 관리시료의 농축을 이용한 보고 가능 범위의 설정에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Choi, Ho Sung;Park, Yong Won;Yun, Keun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • This study was designed to establish working range for reoportable range in own laboratory in order to cover the upper and lower limits of the range in test method. We experimented ten times during 10 days for setting of reportable range with between run for method evaluation. It is generally assumed that the analytical method produces a linear response and that the test results between those upper and lower limits are then reportable. CLIA recommends that laboratories verify the reportable range of all moderate and high complexity tests. The Clinical Laboratory Improvement Amendments(CLIA) and Laboratory Accreditation Program of the Korean Society for Laboratory Medicine states reportable range is only required for "modified" moderately complex tests. Linearity requirements have been eliminated from the CLIA regulations and from others accreditation agencies, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. It is important to assess the useful reportable range of a laboratory method, i.e., the lowest and highest test results that are reliable and can be reported. Manufacturers make claims for the reportable range of their methods by stating the upper and lower limits of the range. Instrument manufacturers state an operating range and a reportable range. The commercial linearity material can be used to verify this range, if it adequately covers the stated linear interval. CLIA requirements for quality control, must demonstrate that, prior to reporting patient test results, it can obtain the performance specifications for accuracy, precision, and reportable range of patient test results, comparable to those established by the manufacturer. If applicable, the laboratory must also verify the reportable range of patient test results. The reportable range of patient test results is the range of test result values over which the laboratory can establish or verify the accuracy of the instrument, kit or test system measurement response. We need to define the usable reportable range of the method so that the experiments can be properly planned and valid data can be collected. The reportable range is usually defined as the range where the analytical response of the method is linear with respect to the concentration of the analyte being measured. In conclusion, experimental results on reportable range using concentrated control sample and zero calibrators covering from highest to lowest range were salicylate $8.8{\mu}g/dL$, phenytoin $0.67{\mu}g/dL$, phenobarbital $1.53{\mu}g/dL$, primidone $0.16{\mu}g/dL$, theophylline $0.2{\mu}g/dL$, vancomycine $1.3{\mu}g/dL$, valproic acid $3.2{\mu}g/dL$, digitoxin 0.17ng/dL, carbamazepine $0.36{\mu}g/dL$ and acetaminophen $0.7{\mu}g/dL$ at minimum level and salicylate $969.9{\mu}g/dL$, phenytoin $38.1{\mu}g/dL$, phenobarbital $60.4{\mu}g/dL$, primidone $24.57{\mu}g/dL$, theophylline $39.2{\mu}g/dL$, vancomycine $83.65{\mu}g/dL$, valproic acid $147.96{\mu}g/dL$, digitoxin 5.04ng/dL, carbamazepine $19.76{\mu}g/dL$, acetaminophen $300.92{\mu}g/dL$ at maximum level.

  • PDF

Novel Average Value Model for Faulty Three-Phase Diode Rectifier Bridges

  • Rahnama, Mehdi;Vahedi, Abolfazl;Alikhani, Arta Mohammad;Nahid-Mobarakeh, Babak;Takorabet, Noureddine
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.288-295
    • /
    • 2019
  • Rectifiers are widely used in industrial applications. Although detailed models of rectifiers are usually used to evaluate their performance, they are complex and time-consuming. Therefore, the Average Value Model (AVM) has been introduced to meet the demand for a simple and accurate model. This type of rectifier modeling can be used to simplify the simulations of large systems. The AVM of diode rectifiers has been an area of interest for many electrical engineers. However, healthy diode rectifiers are only considered for average value modeling. By contrast, faults occur frequently on diodes, which eventually cause the diodes to open-circuit. Therefore, it is essential to model bridge rectifiers under this faulty condition. Indeed, conventional AVMs are not appropriate or accurate for faulty rectifiers. In addition, they are significantly different in modeling. In this paper, a novel application of the parametric average value of a three-phase line-commutated rectifier is proposed in which one diode of the rectifier is considered open-circuited. In order to evaluate the proposed AVM, it is compared with experimental and simulation results for the application of a brushless synchronous generator field. The results clearly demonstrate the accuracy of the proposed model.

Present Status of Green Solvents (녹색용매 기술동향)

  • Lee, Jun-Wung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.475-491
    • /
    • 2012
  • Green Chemistry emerged at the end of 20th century, which aims the development of the technologies for the sustainable society at the molecular level. Most products we consume in everyday life are produced through chemical processes, and we often oversee the fact that huge amount of solvents are used and disposed. At the present time most solvents used in laboratories as well as industries are volatile organic compounds(VOC), which gives health and environmental problems. Therefore scientists are seeking new materials which have equivalent properties of VOCs as solvent, and at the same time gives no health and environmental problems. In this brief review, the author describes the present status of research and development activities of green solvent materials throughout research societies worldwide. At present the most attractive green solvent candidates are water, glycerol, supercritical carbon dioxide and ionic liquids. In order to give the pictures of these materials, the author tried to introduce the overall aspects of green solvents in various chemical reaction as well as catalytic roles.

Hardware Digital Color Enhancement for Color Vision Deficiencies

  • Chen, Yu-Chieh;Liao, Tai-Shan
    • ETRI Journal
    • /
    • v.33 no.1
    • /
    • pp.71-77
    • /
    • 2011
  • Up to 10% of the global population suffers from color vision deficiency (CVD) [1], especially deuteranomaly and protanomaly, the conditions in which it is difficult to discriminate between red and green hues. For those who suffer from CVD, their career fields are restricted, and their childhood education is frustrating. There are many optical eye glasses on the market to compensate for this disability. However, although they are attractive due to their light weight, wearing these glasses will decrease visual brightness and cause problems at night. Therefore, this paper presents a supplementary device that comprises a head-mounted display and an image sensor. With the aid of the image processing technique of digital color space adjustment implemented in a high-speed field-programmable gate array device, the users can enjoy enhanced vision through the display without any decrease in brightness.

Biological green synthesis of gold and silver nanoparticles

  • Sur, Ujjal Kumar
    • Advances in nano research
    • /
    • v.2 no.3
    • /
    • pp.135-145
    • /
    • 2014
  • Nanomaterials synthesized by natural bioresources such as microorganisms, animals and plants in nature can also be synthesized in laboratories even on large scale. This is considered as an attractive prospect for eco-friendly or so-called green synthesis. Development of eco-friendly synthesis of biocompatible nanoparticles and their potential biomedical applications introduces the concept of nanobiotechnology. The lower cost and lesser side effects as compare to chemical methods of synthesis are the main advantages of biosynthesis. This review article demonstrates the role of various biological resources e.g. bacteria, fungi, actinomycetes, plant leaves, fruits and honey as well as animal tissues for the synthesis of nanoparticles mainly gold and silver with an overview of their potential applications.

Effects of the Combination Herbal Extract on Working Memory and White Matter Integrity in Healthy Individuals with Subjective Memory Complaints : A Randomized, Double-Blind, Placebo-Controlled Clinical Trial

  • Kwon, Oran;Lee, Sunho;Ban, Soonhyun;Im, Jooyeon J.;Lee, Doo Suk;Lee, Eun Hee;Kim, Joohee;Lim, Soo Mee;Lee, Sang Gon;Kang, Ilhyang;Kim, Kyung-Hee;Yoon, Sujung;Lee, Sun Hea
    • Korean Journal of Biological Psychiatry
    • /
    • v.22 no.2
    • /
    • pp.63-77
    • /
    • 2015
  • Objectives The combination extract of four kinds of herbs, Gastrodia elata, Liriope platyphylla, Dimocarpus longan, and Salvia miltiorrhiza, has shown to have memory improving effects in mice. The aim of this study was to investigate the efficacy and safety of the herbal mixture for improving working memory as well as microstructural changes in white matter integrity in individuals with subjective memory complaints. Methods Seventy-five individuals with subjective memory complaints were assigned to receive either placebo (n = 15) or herbal mixture (low-dose group, n = 30 and high-dose group, n = 30) supplementation in an 8-week, randomized, double-blind, placebo-controlled clinical trial. Changes in working memory performance and fractional anisotropy (FA) values reflecting white matter integrity from baseline to 8-week endpoint were assessed. Results The herbal mixture group showed an increase in working memory performance compared to the placebo group (p for interaction = 0.001). In addition, the herbal mixture group showed an increase in FA values in the temporo-parietal regions (corrected p < 0.05), which are crucially involved in working memory function and are among the most affected regions in patients with cognitive impairments. Conclusions Findings from this study indicate that the herbal mixture may be a promising therapeutic option for individuals with subjective memory complaints.

Simultaneous Quantification of Urinary L-, and D-Lactate by Reversed-Phase Liquid Chromatography Tandem Mass Spectrometry (액체크로마토그래프-탠덤질량분석기(LC-MS/MS)를 이용한 소변 내 D-, L- Lactate 분리 및 정량)

  • Moon, Chul Jin;Yang, Song Hyun
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.2
    • /
    • pp.59-64
    • /
    • 2015
  • Purpose: Lactate has two optical isomers, L-lactate and D-lactate. In human L-lactate is the most abundant enantiomer of lactate. As plasma and urinary levels of L-lactate is associated with inherited metabolic disorders in general, D-lactate have been linked to the presence of diabetes and inflammatory bowel disease. Previously developed techniques have shown several limitations to further evaluate D-lactate as a biomarker for this condition. In this paper, we describe a highly sensitive, specific and fast liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of D-, L-lactate in urine. Methods: D- and L-lactate were quantified using high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) with labelled internal standard. Samples were derivatized with (+)-O,O'-diacety-L-tartaric anhydride (DATAN) and seperated on a Poroshell 120 EC-C18 column. Results: Quantitative analysis of D-, and L-lactate was achieved successfully. Calibration curves were linear (r>0.999) over $0.5-100{\mu}g/mL$. Stabilities for samples were within the 10% varation. Inter- and Intra-day assay variations were below 10%. Conclusion: The presented method proved to be suitable for the quantitation of D- and L-lactate and opens the possibility to explore the use of D-lactate as a biomarker.