• Title/Summary/Keyword: green area

Search Result 2,354, Processing Time 0.025 seconds

Observational Study of Thermal Characteristics by Distribution Ratio of Green Area at Urban in Summer Season (하절기 관측을 통한 도시의 지역별 공간녹지분포율에 따른 열환경 특성 연구)

  • Jung, Im-Soo;Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.8-16
    • /
    • 2011
  • The objective of this study is to analyze the characteristic of thermal environment in the summer season by conducting the field observation of temperature, relative humidity, and globe temperature in some parts of the city. Observation point was divided to a densely populated area, a residential area, a green area, a waterfront green area and a suburban district by the distribution ratio of green area. In this study, the correlation between maximum temperature and globe temperature, study on index for intensity of the tropical night and the temperature distribution characteristic of measurement points by the distribution ratio of green area were analyzed. The results of this study are as follows. (1) The difference between temperature and globe temperature by the distribution ratio of green area is confirmed. The difference of nighttime is more clearly that of daytime. (2) The average temperature and globe temperature of the densely populated area($29.2^{\circ}C$, $33.7^{\circ}C$) are higher than that of the waterfront green area($27.9^{\circ}C$, $32.0^{\circ}C$) by $1.3^{\circ}C$ and $1.7^{\circ}C$, respectively. (3) The number of tropical nights has different days of tropical nights by the distribution ratio of green area of 17days for the Daegu weather station, 14days for adensely populated area, 14days for a residential area, 6days for a green area, 2days for a waterfront green area, and 2days for a suburban district. (4) The results of the slope of trend line for the effects of the temperature on globe temperature change and the intercept for the size of the impact of radiant energy gained around by the analysis of the correlation between the maximum temperature and globe temperature can be utilized objective evaluation index of the each point's artificial effects.

Estimation of the Available Green Roof Area using Geo-Spatial Data (공간정보를 이용한 옥상녹화 가용면적 추정)

  • Ahn, Ji-Yeon;Jung, Tae-Woong;Koo, Jee-hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.5
    • /
    • pp.11-17
    • /
    • 2016
  • The purposes of this research are to estimate area of greenable roof and to monitor maintaining of green roofs using World-View 2 images. The contents of this research are development of World-View 2 application technologies for estimation of green roof area and development of monitoring and maintaining of green roofs using World-View 2 images. The available green roof areas in Gwangjin-gu Seoul, a case for this study, were estimated using digital maps and World-View 2 images. The available green roof area is approximately 12.17% ($2,153,700m^2$) of the total area, and the roof vegetation accounts for 0.46% ($80,660m^2$) of the total area. For verification of the extracted roof vegetation, Vworld 3D Desktop map service was applied. The study results may be used as a decision-making tool by the government and local governments in determining the feasibility of green roof projects. In addition, the project implementer may periodically monitor to see whether roof greening has maintained for efficient management of projects, and a vast amount of World-View 2 images may be regularly used before and after the projects to contribute to sharing of satellite images information.

Change of Green Space Arrangement and Planting Structure of Apartment Complexes in Seoul (서울시 아파트단지의 녹지배치 및 식재구조 변화 연구)

  • Lee, Dong-Wook;Lee, Kyong-Jae;Han, Bong-Ho;Jang, Jae-Hoon;Kim, Jong-Yup
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.1-17
    • /
    • 2012
  • This study was carried out to propose the improved method by analyzing the change of green space arrangement and planting structure of apartment complexes in Seoul. 12 survey sites, which have obvious differences, were selected by reflecting the change of floor area ratio, underground parking place, and green space ratio. We divided the survey sites into four types that high green ratio(over 40%) apartment on natural ground, low green ratio(under 40%) apartment on natural ground, low green ratio(under 40%) apartment on artificial ground, and high green ratio(over 40%) apartment on artificial ground each period based on green space ratio and ground structure, plant crown volume, planting density, and planting pattern. The main factors of change of green space arrangement were green space ratio and ground structure. The Green space ratio was changed by the floor area ratio with constructing underground parking place and floor area ratio was adjusted by government policy and economic status. Average width of front green area has been changed from 10.0m in high green ratio apartment on natural ground for 3.5m, 2.7m, and 4.5m each period. The average width of the buffer green area has been changed from 15.0m in high green ratio apartment on natural ground of 7.7m, and 2.7m by extending parking place in the low green ratio apartment of artificial ground, so buffer green areas have been reduced and disconnected. So buffer green area in apartment complexes has been extended that the average width of the buffer green area was 3.8m caused by growing recognition of green since 2001. The ratio of native plant in canopy layer was increased from 45.1 % in the case of the high green ratio apartment of natural ground in 1980~1983 to 55.6%. Average plant crown volume increased from $1.27m^3/m^2$ in high green ratio apartment on natural ground for $3.47m^3/m^2$ in a low green ratio apartment on natural ground. But average plant crown volume is $0.27m^3/m^2$ in the high green ratio apartment of the artificial ground plant density of canopy layer was changed from 5 individuals per $100m^2$ to 14.5 individuals per $100m^2$. We should construct the buffer green area with natural ground and get the function of ecological and beautiful environment regarding to garden concept in case of front green area, width 4.5m. We should get the function of increasing green volume by multi-layer planting with shade woody species and flower woody species in case of back-side green area, width over 5.0m. We should get the function of covering the wall and increasing green landscape by planting with high woody species in case of side green area. We should apply the ecological planting technique to buffer green area and connect buffer green area to inner green area in apartment complexes.

The Classification and Characteristics of Landscape on Urban Land Use Patterns - The Case of Metropolitan Daejeon - (도시의 토지이용 형태별 경관특성과 유형 - 대전광역시를 사례로 -)

  • Kim Dae-Hyun;Kim Dae-Soo;Joo Shin-Ha;Oh Se-Rae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.4 s.111
    • /
    • pp.1-10
    • /
    • 2005
  • Recently, as urban landscape is growing in importance, urban landscape planning is being actively performed. for this purpose, classification of the urban landscape is definitely required. Therefore, this research focuses on classifying urban landscape in Daejeon metropolis by dividing the urban land use pattern. This results are as follows. 1. Urban land use pattern is divided into 20 classes. The residential, commercial and industrial areas, the old market and the bus terminal are evaluated negatively, whereas the areas of school, water reservoir, neighborhood park and train station are appreciated as being positive in landscape characters. 2. As a result of a cluster analysis, urban landscape has five different landscape types. These are: landscapes of medium diversity lacking green area, landscapes of high diversity lacking green area, landscapes rich in green area and with medium diversity, landscapes rich in green area and with high diversity, and landscapes rich in green area and with low diversity. 3. In landscape characters of beauty and harmony, landscapes rich in green area and with medium diversity are more positively evaluated than those rich in green area and with low diversity. This point should be taken into account for planning the urban landscape.

A Study on the Conservation Plan of the Regional Green Space in the Tokyo Metropolitan Area - A Case Study of the Minuma Tanbo Area -

  • Hiroshi Akiyama;Sonomi Ishi;Yuki Mashimo;Sadatoshi Tabata
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.2
    • /
    • pp.171-177
    • /
    • 2004
  • This surveillance research drafted a conservation plan of regional green spaces, on a metropolitan area level, geared toward the Minuma Tanbo area of 1260 ha, located in Saitama City, in the suburbs of Tokyo. It was an effective method, applied to an area where Japan's current issues on regional green space were epitomized, as it formed symposiums consisting of various personnel, and the opinions of the citizen had been reflected.

  • PDF

An Analysis of Rational Green Area Ratio by Land Use Types for Mitigating Heat-Island Effects (도시열섬완화를 위한 토지 이용 유형별 합리적 녹지율 분석)

  • SONG, Bong-Geun;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.2
    • /
    • pp.59-74
    • /
    • 2015
  • The purpose of this study is to analyze reasonable green area ratios for mitigating urban heat island considering various land use types. Land uses of 5 types such as single residential, multi residential, commercial area, public facility, and industrial area were considered. Green areas were extracted from the tree attribution of land cover. Effect of urban heat island was analysed by the surface temperature of ASTER thermal infrared radiance scanned daytime and nighttime. Mitigation effect of green area at daytime was higher than nighttime. Surface temperature of green area was low in single residential at daytime. But the difference of surface temperature by each land use type was small. The effect of surface temperature mitigation of green area was lower in industrial area. The results of reasonable green area ratios for mitigating urban heat island indicate that surface temperature was the lowest with green area ratio of 40~50% in single residential, multi residential, and commercial area at daytime. Surface temperature of nighttime was not changed much by green area ratios. Therefore, the results of this study will be suggested in urban development planning to construct effectively green area for mitigating urban heat island.

Restoration and Landscape Ecological Design to Restore Mt. Nam in Seoul, Korea as an Ecological Park (복원 및 경관생태학적 원리에 근거한 남산의 생태공원화 계획)

  • 이창석;문정숙;김재은;조현제;이남주
    • The Korean Journal of Ecology
    • /
    • v.21 no.5_3
    • /
    • pp.723-733
    • /
    • 1998
  • Restoration to improve the ecological quality of Mt. Nam was explored in a viewpoint of restoration in both landscape and ecosystem levels. A restoration plan in landscape level was based on the result on the land-use pattern in Mt. Nam including its surrounding area and that in ecosystem level on the ecological quality of each landscape element. A plant to construct the green network, which extending from Mt. Nam to the Han river through the Yongsan family park and through the Eungbong urban park was prepared as a restoration project in landscape level to improve the ecological quality of Mt. Nam as an ecological park. On the other hand, a plan for restoration and creation of biotop as a restoration project in ecosystem level was also prepared to improve the ecological quality of each green area consisting green network. Green areas composing green network include keystone green area (Mt. Nam), green stations (Yongsan family park, Eungbong urban park, and the han river citizen's park), and green pathway (or ecological corridor) connecting those green areas.

  • PDF

A Study on Factor Extraction of Green-Network by Assessment Indicators -For the purpose of Biotop creation- (평가지표를 통한 녹지네트워크 인자도출에 관한 연구 -비오토프 조성을 위하여-)

  • Kim, E-Shin;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.3
    • /
    • pp.75-83
    • /
    • 2001
  • This study selected Yangpyung as a target site because Yangpyung is a area of high value blessed with well preserved natural resources and beautiful natural scene and where thoughtless development and malformed use of land are in progress under the mask of hotel, accommodations and sales facility which fits the interests of land owner. As for the method used for this study, I inquired into domestic/international instances and the concept of existing environmental indicators and assessment of suitability with a view to establish assessment indicators and pose the concept through theoretical investigation of green-network and to establish green-network. 17 articles of environmental indicators such as aspect analysis, contour, greenbelt, DEM, NDVI, nature conservation area, reservoir and area for the promotion of agriculture were chosen as a actual analysing n data for setting up assessment indicators. From the result of analysis, as anticipated, green zone in Yongmusan areas within Youngmun and Seojong areas were the center of green-network in the wide area green-network in Yangpyung and the restricted area by basin system, road and legal regulation was selected as spot area and finally arable land and reservoir were selected as base which connects core with spot.

  • PDF

A Study on the Environmental Assessment for Regional-Based Green Area Conservation (지역단위 녹지 확보를 위한 환경성평가방안 연구)

  • Oh, Seung-Ryun;Kang, Seon-Hong;Lee, Chun-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.535-546
    • /
    • 2011
  • The study area investigated in this research is Hwaseong city, Gyeonggi-Do where small scale development is currently in progress. For the last three years, we carried out the environmental and ecological assessment by using data from The Ministry of Environment and Han River Basin Environmental Office. Most of development works in Hwaseong city, Gyeonggi-Do are small scale developments which are related with factory and distribution complex based on individual laws and regulations. However, environmental and ecological assessment is not being sufficiently reflected beforehand. Especially, because the development takes place mainly in the outskirts of the city, the fine forest is continuously being damaged. We analyzed changes in green zone area caused by the developments. As a result, the percentage of original green zone was decreasing while the percentage of artificial green zone was increasing. We should maintain the percentage of the original green zone in order to conserve natural environment. In the past three years, the damage of the DGN (Degree of Green Naturality) 7 area that has high conservative value was little, but, there was serious damage in the area of DGN 6. In order to conserve natural environment, political and institutional investigation should be seriously carried out for mitigation of environmental and ecological damages.

Evaluation of Pedestrian Space Ion Index by Land Use Type in Heat wave - Focused on ChungJu - (폭염시 토지이용유형별 보행공간 이온지수 평가 - 충주시를 대상으로 -)

  • Yoon, Yong Han;Yoon, Ji Hun;Kim, Jeong Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.3
    • /
    • pp.354-365
    • /
    • 2019
  • This study measured and analyzed the weather characteristics and the air-ion characteristics of walking space by land use type in Chungju, Chungcheongbuk Province during the heat wave. We used the land registration map to classify the type of land use in walking areas in the studied into the production and green area, the residential area, and the commercial area. We then selected 44 measurement points in about 4.1 km. They included 12 walking space points in the green area, 14 in the residential area, and 18 in the commercial area. Moreover, we calculated the ion index by analyzing the impact of weather factors such as temperature, relative humidity, solar radiation, and net radiation in the walking space on the anion generation and cation generation by land use type during the heat wave. Comparison of air ion characteristics in walking space by type of land use during the heat wave showed that the average cation generation was in the order of commercial area ($700.73cations/cm^3$) > residential area ($600.76cations/cm^3$) > green area ($589.73cations/cm^3$). The average anion generation was in the order of green area ($663.95anions/cm^3$) > residential area ($628.48anions/cm^3$) > commercial area ($527.48anions/cm^3$). The average ion index was in the order of green area (1.13) > residential area (1.04) > commercial area (0.75). This study checked the weather characteristics, cation generation, and anion generation in walking space according to the land use type during the heat wave and checked the difference of ion indexes in the walking space according to the land use type. However, there were limitations in the lack of accurate comparison according to the land use due to the moving measurement and the insufficient quantitative comparison according to the change of road width. Therefore, we recommend further studies that consider the road characteristics.