• 제목/요약/키워드: grease

검색결과 201건 처리시간 0.038초

열처리 조건에 따른 XLPE / EPDM 계면의 전기적 특성 (Electrical Characteristics of the Interfacial Layer between XLPE/EPDM Laminates on the Heat Treatment)

  • 최원창;이제정;김석기;조대식;한상옥;박강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.225-228
    • /
    • 1997
  • The main fault in this interface is that power cable insulating materials are mainly composed of a double layered structure, XLPE/FPDM laminates in cable joint. In this parer, we instituted the interface of XLPE/EPDM laminates and then investigated the breakdown and conduction characteristics as a function of heat treatment time. The results showed that conduction current was influenced by volatile crosslinking by-products which remained inside the insulating material during the production of XLPE and EPDM, especially during heat treatment process. And conduction current of XLPE/Oil 12500cSt/EPDM was more stable than XLPE/Grease/EPDM from the long heat treatment time. AC breakdown strength of silicone oil itself from the heat treatment was changed during the 4∼12 hour heat treatment time.

  • PDF

열전도율 변화에 따른 Bi-Te계 열전모듈의 열전특성 (Thermoelectric Characteristics of Bi-Te Module with Thermal Conductivity Change)

  • 김봉서;정현욱;박수동;한동희;이희웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2025-2027
    • /
    • 2005
  • Thermal conductive polymer film was adopted to reduce the fracture of module during the fabrication of thermoelectric generator. We investigated the thermoelectric output power of module with the change of thickness of polymer film, direct contact and thermal-conductive grease. It is measured that thermoelectric output power is decreased with the increasing thickness of thermal-conductive polymer film. And

  • PDF

Development of the High Performance Thermoelectric Modules for High Temperature Heat Sources

  • Jinushi, Takahiro;Okahara, Masahiro;Ishijima, Zenzo;Shikata, Hideo;Kambe, Mitsuru
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.79-80
    • /
    • 2006
  • From a viewpoint of heat stress at high temperatures and contact thermal resistance, it is confirmed that the optimal structure is the skeleton structure using Cu substrate on the cooling side, which has excellent heat conductivity and the optimal installation method is to adopt a carbon sheet and a mica sheet to the high temperature side, where Si grease is applied to the low temperature side, under pressurized condition. The power of the developed modules indicated 0.5W in an $FeSi_2$ module and 3.8 W with a SiGe module at 823K, respectively.

  • PDF

윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구 (An Experimental Study on the Light Transmission Characteristics with Oil Contamination)

  • 조성용;장철주;공호성;윤의성;한흥구
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.287-298
    • /
    • 2001
  • Change in light transmission characteristics caused by various types of oil contaminations was experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon dust, two kinds of solutions and grease were used for the lest contaminants in this work. Light intensity of the transmitted light was treasured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and polymeric fibers mainly due to the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change iii lubricating oils.

  • PDF

The Analysis on the Deformation of Electrostrictive Polymer Film with respect to Time under Constant Voltage

  • Park, Kyung-Chul;Yun, Ji-Won;Jeon, Jae-Wook;Park, Hyoukryueol;Kim, Hunmo;Nam, Jae-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.46.5-46
    • /
    • 2001
  • Electrostrictive polymer is deformed by electric force generated by electric field built by high voltage. When high voltage is applied to the electrostrictive polymer film in which the electrodes such as conductive grease or carbon powder are installed, it expands in the direction of area. Because electrostrictive polymer is incompressible and electric force is applied to it in the direction of thickness. Electrostrictive polymer film in which electrodes are installed, functions as a parallel-plate capacitor. Therefore anode and cathode charges are piled up or both electrodes and there exists attractive force that functions as pressure in the direction of thickness. So the thickness of electrostrictive polymer becomes thicker ...

  • PDF

리니어 구동 구조의 마찰 저감을 위한 수동형 성장 피복 (A Passively Growing Sheath for Reducing Friction of Linearly Moving Structures)

  • 서한범;김동기;정광필
    • 로봇학회논문지
    • /
    • 제17권2호
    • /
    • pp.159-163
    • /
    • 2022
  • A linearly moving structure in the area where the friction force is dominant - such as ducts filled with grease in the nuclear power plant - experiences increase in friction since the contact surface gets larger as the structure proceeds. To solve this problem is critical for the pipe inspection robot to investigate further area and this makes the system more energy-efficient. In this paper, we propose a passively growing sheath that can be added to linearly moving structures using zipper mechanism. The mechanism enables the linearly moving structures to maintain rolling contact condition against external environment, which provides substantial reduction in kinetic friction. To analyze the effect of the mechanism's head shape, we establish a physical model and compare to the experimental results. Finally, we have shown that the passively growing sheath can be successfully applied to the pipe inspection robot for the nuclear power plant.

Sb-DTC의 합성 및 물성 평가에 관한 연구 (A Study on Synthesis and Evaluation of Sb-DTC)

  • 조원오;이기헌;전인식;백진욱;정근우;김영운
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제32회 추계학술대회 정기총회
    • /
    • pp.90-99
    • /
    • 2000
  • This report describes the results of analysis, synthesis and evaluation of antimony dithiocarbamates (SbDTC). Sb-DTC were synthesized by reacting antimony oxide with dithiocarbamates whish were prepared by reaction of dialkylamines and carbon disulfide. The chemical structures and properties of synthesized Sb-DTCs in lab. were discussed. The frictional properties of SbDTC were tested with Four-Ball Wear Scar Tester and Four-Ball Extreme Tester by ASTM method.

  • PDF

군용차량용 엔진일체형 직렬 발전기 부식 방지에 관한 연구 (A Study on the Corrosion Prevention of the Integral Series Generator for Military Vehicles)

  • 강태우;김성곤;신철호;이계섭
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.74-79
    • /
    • 2019
  • 군용차량은 별도의 발전기 장착공간을 마련하지 않고 엔진과 연결되어 발전하는 엔진일체형 직렬 하이브리드 발전기를 통해 전력을 생산한다. 그러나 발전기와 엔진 간 연결 방식이 가지는 기계적 특성에 따라 내부 방청 및 윤활용 그리스가 비산하여 산화철이 발생했다. 산화철이 시동기에 고착되어 시동성능이 저하되고 기어마모에 따른 레틀 소음이 증대되는 문제가 발생하였다. 이러한 문제를 해결하기 위하여 엔진의 연결 스플라인 재질 및 표면처리를 개선하고 형상을 그리스 밀봉형으로 변경하여 내부의 산화철 발생을 방지하였다. 축계를 구성하는 발전기 연결기의 형상이 변경됨에 따라 비틀림 내구 시험을 통해 구조의 건전성을 확인하였다. 또한 실차 부하시험을 통하여 내부 부식 없이 목표한 내구수명 동안 부식이 발생하지 않음을 검증하였다. 그리스 비산 방지구조가 실제로 산화철의 발생을 억제함으로써 발전기에서 발생하는 소음을 감소시키는지 확인할 수 있었다. 본 논문은 엔진과 변속기 사이에 장착하는 직렬 하이브리드 발전기에서 발생하는 배부 부식을 방지하여 시동기의 성능저하 현상과 소음 발생 현상에 대한 근본적인 해결방안을 제시하였다고 할 수 있다.

광촉매 코팅한 모르타르를 이용한 대기 중 NOX의 광화학적 변환 (Photochemical Conversion of NOX in Atmosphere by Photocatalyst Coated Mortar)

  • 진현;윤경구;최하진;김교선
    • Korean Chemical Engineering Research
    • /
    • 제61권2호
    • /
    • pp.240-246
    • /
    • 2023
  • 친환경적인 태양에너지를 사용하여 대기오염물질인 NOx를 광화학적 반응으로 변환시키는 연구를 수행하였으며 광촉매를 모르타르 표면에 코팅한 시편을 제조하여 NOx의 광화학적 전환율을 분석하였다. TiO2 광촉매를 거푸집의 하부에 먼저 넣고 시멘트 모르타르를 넣은 후 시멘트 모르타르를 양생시켜 광촉매 코팅된 콘크리트를 제조하였다. 거푸집 바닥에 미리 grease를 도포함으로써 양생 후에 콘크리트가 쉽게 탈형될 수 있도록 하였다. TiO2 코팅 양, UV-A 광 세기, 전체 기체 유량, 상대 습도, 그리고 초기 NOx 농도와 같은 공정 변수를 체계적으로 변화시켜서 광촉매 반응에 의한 NOx의 전환율을 조사하였다. 제조된 광촉매 코팅된 콘크리트가 다양한 공기 중의 공정 변수 조건에서 NOx를 성공적으로 전환시키는 것을 확인하였다. 본 연구 결과는 향후 NOx, SOx, VOCs 등의 대기오염물질을 효과적으로 제어하기 위한 건물, 터널, 또는 도로와 같은 인프라 시설의 설계를 위한 기초 자료로 활용될 수 있을 것으로 본다.

일반 가설앵커의 문제점과 개선방향 (Ground Anchor Testing on Temporary Excavations)

  • 김성규;김낙경;김정렬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.545-552
    • /
    • 2003
  • For temporary excavation support in a congested urban area, the strand of ground anchor should be removed to get permission of the private land to install anchors. But the strand doesn't need to be removed in the outside city area after use. So the anchor body, tension anchor, is fabricated in-situ. The unbonded length of This anchor has several strands, which wrap only one sheath. When the anchor body is carried into job-site or installed in the bore hole, the sheath is torn easily because it is a very week material. So the grout permeate into the torn sheath. Because of that, the load doesn't transfer to the bond length of ground anchors. It may indicate that load is being transferred along the unbonded length and thus within the potential slip surface assumed for overall stability of the anchored system. The load tests were performed on seven low-pressure grouted anchors installed in weathered soil to verify its problems. Four anchors(Type A) have the unbonded length, which consist of five strands and a week sheath and three anchors(Type B) have strands, which is covered by plastic sheath filled with grease, in the unbonded length. Both anchors are compared with load tests results.

  • PDF