• 제목/요약/키워드: gravity-load design

검색결과 150건 처리시간 0.027초

Compatible Anchors of Silt Protector in Shallow Sea with Mud Seafloor Material (천해역 점성토 지반에 적합한 오탁방지막 기초 앵커)

  • KWEON GI-CHUL;HONG NAM-SEEG;SONG Mu-HYO;CHOI CHANG-GYU
    • Journal of Ocean Engineering and Technology
    • /
    • 제17권3호
    • /
    • pp.7-12
    • /
    • 2003
  • The Navy has tested the holding capacity of many kinds of anchors in order to propose the design chart for the holding capacity of drag-embedment anchors. The design chart is only applicable up to the cable bottom angle 60 when load is raised to the ultimate weight. However, the anchor experiences a significant uplift force when the angle is above 60 in shallow seas. In this paper, the procedure for the estimation of the holding capacity of anchors in mud is proposed. Drag-embedment anchors do not function well when there is a significant uplift component of load in soft seafloor materials, such as mud. Under these loading and seafloor conditions, gravity anchors seems to be more efficient. However, they are too heavy for their holding capacity. Therefore, suction pile (hollow concrete block) is more beneficial to the foundntion of silt protector in shallow sea with mud seafloor materials.

Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns

  • Goldsworthy, H.M.;Gardner, A.P.
    • Structural Engineering and Mechanics
    • /
    • 제24권4호
    • /
    • pp.463-478
    • /
    • 2006
  • The design of structural frameworks for buildings is constantly evolving and is dependent on regional issues such as loading and constructability. One of the most promising recent developments for low to medium rise construction in terms of efficiency of construction, robustness and aesthetic appearance utilises concrete-filled steel tubular sections as the columns in a moment-resisting frame. These are coupled to rigid or semi-rigid connections to composite steel-concrete beams. This paper includes the results of a pilot experimental programme leading towards the development of economical, reliable connections that are easily constructed for this type of frame. The connections must provide the requisite strength, stiffness and ductility to suit gravity loading conditions as well as gravity combined with the governing lateral wind or earthquake loading. The aim is to develop connections that are stiffer, less expensive and easier to construct than those in current use. A proposed fabricated T-stub connection is to be used to connect the beam flanges and the column. These T-stubs are connected to the column using "blind bolts" with extensions, allowing installation from the outside of the tube. In general, the use of the extensions results in a dramatic increase in the strength and stiffness of the T-stub to column connection in tension, since the load is shared between membrane action in the tube wall and the anchorage of the bolts through the extensions into the concrete.

Analytical study of slant end-plate connection subjected to elevated temperatures

  • Zahmatkesh, F.;Osman, M.H.;Talebi, E.;Kueh, A.B.H.
    • Steel and Composite Structures
    • /
    • 제17권1호
    • /
    • pp.47-67
    • /
    • 2014
  • Due to thermal expansion, the structural behaviour of beams in steel structures subjected to temperature increase will be affected. This may result in the failure of the structural members or connection due to extra internal force in the beam induced by the thermal increase. A method to release some of the thermally generated internal force in the members is to allow for some movements at the end supports of the member. This can be achieved by making the plane of the end-plate of the connection slanted instead of vertical as in conventional design. The present paper discusses the mechanical behaviour of beams with bolted slant end-plate connection under symmetrical gravity loads, subjected to temperature increase. Analyses have been carried out to investigate the reduction in internal force with various angles of slanting, friction factor at the surface of the connection, and allowable temperature increase in the beam. The main conclusion is that higher thermal increase is tolerable when slanting connection is used, which means the risk of failure of structures can be reduced.

Structural Performance of Column-Slab Connection in Flat Plate System Using High Strength Concrete (고강도 콘크리트를 사용한 플랫 플레이트 구조의 기둥·슬래브 접합부 구조성능)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제10권1호
    • /
    • pp.97-105
    • /
    • 2006
  • The reinforced concrete flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problem in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab connection. Since the use of high strength concrete recently has become in practice for reinforced concrete structures, it is highly desired to establish the structural design method for flat plate construction using high strength concrete. In this paper, interior column-slab connection constructed with high strength concrete were tested under lateral and gravity loads to evaluate their strength and behavior. The test parameters were slab reinforcement ratio and the gravity load levels.

Seismic Behaviors of OMRCF Columns (철근 콘크리트 보통 모멘트 골조 기둥의 거동평가)

  • 한상환;이리형
    • Journal of the Korea Concrete Institute
    • /
    • 제14권2호
    • /
    • pp.199-206
    • /
    • 2002
  • The objective of this study is to investigate the seismic behavior and evaluate structural performance of columns in Ordinary Moment Resting Concrete Frames (OMRCF). For this purpose 3 story OMRCF building was designed and detailed in compliance to ACI 318 (1999). Only gravity load is considered for the design. It is important to note that details strongly relate to the structural performance. The 1st story columns in the 3 story building are considered in this study since 다lese columns shall resist the largest axial and lateral forces during an earthquate. Four test specimens were made for representing the upper part and lower part of exterior and interior columns. All specimens are two-third scale. Based on the test results this study estimates deformation, ductility, strength, and energy absorption capacities as well as plastic hinge length.

Comparative Evaluation of Structural Systems for Tilted Tall Buildings

  • Moon, Kyoung Sun
    • International Journal of High-Rise Buildings
    • /
    • 제3권2호
    • /
    • pp.89-98
    • /
    • 2014
  • Employing tilted forms in tall buildings is a relatively new architectural phenomenon, as are the cases with the Gate of Europe Towers in Madrid and the Veer Towers in Las Vegas. This paper studies structural system design options for tilted tall buildings and their performances. Tilted tall buildings are designed with various structural systems, such as braced tubes, diagrids and outrigger systems, and their structural performances are studied. Structural design of today's tall buildings built with higher strength materials is generally governed by lateral stiffness. Tilted towers are deformed laterally not only by lateral loads but also by dead and live loads due to their eccentricity. The impact of tilting tall buildings on the gravity and lateral load resisting systems is studied. Comparative evaluation of structural systems for tilted tall buildings is presented.

Seismic design of connections between steel outrigger beams and reinforced concrete walls

  • Deason, Jeremy T.;Tunc, Gokhan;Shahrooz, Bahram M.
    • Steel and Composite Structures
    • /
    • 제1권3호
    • /
    • pp.329-340
    • /
    • 2001
  • Cyclic response of "shear" connections between steel outrigger beams and reinforced concrete core walls is presented in this paper. The connections investigated in this paper consisted of a shear tab welded onto a plate that was connected to the core walls through multiple headed studs. The experimental data from six specimens point to a capacity larger than the design value. However, the mode of failure was through pullout of the embedded plate, or fracture of the weld between the studs and plate. Such brittle modes of failure need to be avoided through proper design. A capacity design method based on dissipating the input energy through yielding and fracture of the shear tab was developed. This approach requires a good understanding of the expected capacity of headed studs under combined gravity shear and cyclic axial load (tension and compression). A model was developed and verified against test results from six specimens. A specimen designed based on the proposed design methodology performed very well, and the connection did not fail until shear tab fractured after extensive yielding. The proposed design method is recommended for design of outrigger beam-wall connections.

Analysis and Suggestion of Estimation Equation for Sedimentation in Square Manholes with Straight Path (사각형 중간맨홀에서의 유사 퇴적 분석 및 산정식 제안)

  • Kim, Jung-Soo;Song Ju-Il;Rim Chang-Soo;Yoon, Sei-Eui
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제26권2호
    • /
    • pp.177-189
    • /
    • 2012
  • Sediment load deposited in sewers and manholes reduces not only the capacity of pipes but also the efficiency of the whole sewer system. This causes the inundations of the low places and overflows at manholes, Moreover, sulfides and bad odor can occur due to deposited sediment with organic loads in manholes. Movements of sediment load in manholes are complicated depending on manhole size, location, inside structure, sediment load type, and time. Therefore, it is necessary to understand the movements of sediment load in manholes by experiments. In this study, experiments were implemented by a square manhole with straight path to measure deposited sedimentation quantity. The experimental apparatus was consisted of a high water tank, an upstream tank, test pipes, a sediment supplier, a manhole, and a downstream tank to measure the experimental discharge. The quantity of deposited sediment load was measured by different conditions, such as the inflow condition of sediment(continuous and certain period), the amount of inflow sediment, discharge, and the type of sediment. Jumoonjin sand(S=2.63, D50=0.55mm), general sand(GS, S=2.65, D50=1.83mm) and anthracite (S=1.45, D50=0.80mm) were employed for the experiment. The velocities in inflow pipe were 0.45 m/s, 0.67 m/s, and 0.9 m/s. Sediment load movement and sedimentation quantity in manhole were influenced by many factors such as velocity, shear stress, viscosity, amount of sediment, sediment size, and specific gravity. Suggested regression equations can estimated the quantity of deposited sediment in the straight path square manholes. The connoted equations that were evaluated through the experimental study have velocity range from 0.45 to 0.9m/sec. The study results illustrates that appropriation of design velocity ragne between 1.0 and 2.0m/sec could implement to maintain and manage manholes.

A Study on Potential of Engineered Wood for 9-story Office Buildings (공학목재의 9층 사무소 건물 적용 가능성 연구)

  • Chu, Yurim;Kim, Taewan;Kim, Seung-Rae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • 제21권4호
    • /
    • pp.163-170
    • /
    • 2017
  • The need for eco-friendly building materials such as engineered wood has increased to reduce carbon emissions. Although the range and height of engineered wood buildings are gradually increasing in North America and Europe, engineered wood is mainly used for low-rise residential buildings in Korea. In order to reduce carbon emissions more, therefore, it needs to expand the use of engineered wood by applying it to various buildings with different uses or more stories. With this background, the aim of this study is to investigate the applicability of engineered wood for 9-story office buildings. Since a 9-story building with engineered wood only is not allowed in KBC, an example building has RC ordinary shear walls as the lateral force resisting system while engineered wood is only used for gravity load resisting moment frames. Another example building is also used for comparison where both lateral and gravity load resisting systems are designed by RC. The applicability of engineered wood is investigated by comparing the seismic performance and the amount of carbon emission of both buildings. The result shows that the seismic performance of both buildings was not significantly different while the amount of carbon emission of the engineered wood building was much less then the RC building. Based on this result, engineered wood is sufficiently applicable to 9-story office buildings even though it still needs to pay attention to the shear design of reinforce concrete walls.

Generalization of an Evaluation Formula for Bearing Pressures on the Rubble Mound of Gravity-Based Harbor Structures (중력식 항만구조물의 사석마운드 지반반력 평가식의 일반화)

  • Woo-Sun Park
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • 제35권6호
    • /
    • pp.128-137
    • /
    • 2023
  • In this study, the bearing pressure on the rubble mound of a gravity-based harbor structure with an arbitrarily shaped bottom was targeted. Assuming that the bottom of the structure is a rigid body, the rubble mound was modeled as a linear spring uniformly distributed on the bottom that resists compression only, and the bearing pressure evaluation formula was derived. It was confirmed that there were no errors in the derivation process by showing that when the bottom was square, the derived equation was converted to the equation used in the design. In addition, the validity of the derived equation was proven by examining the behavior and convergence value of the bearing pressure when an arbitrarily shaped bottom converges into a square one. In order to examine the adequacy of the method used in the current design, the end bearing pressure for the pre-designed breakwater cross-section was calculated and compared with the values in the design document. As a result, it was shown that the method used for design was not appropriate as it gave unsafe results. In particular, the difference was larger when the eccentricity of the vertical load was large, such as in the case of extreme design conditions.