• 제목/요약/키워드: gravity building

검색결과 203건 처리시간 0.031초

Panel heating을 적용한 철골조 건물의 합성테크 진동조건 설정에 관한 연구 (A study on the establishment of vibration conditions of a composite deck floor with panel heating systems for a steel structure)

  • 박진영;김희철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.972-977
    • /
    • 2000
  • One of the major differences of Korean residential building compared with other countries is a rigid diaphragm of a floor due to the panel heating system. An increment of a gravity floor load might cause vibration problem when the composite floor system is introduced to the panel heating system. Since the noise criteria of a residential building is lower than that of an office building, the development of a noise absorbing system should be preceded. The response evaluation was performed for the finished floor, that is with panel heating and noise absorbing system. The natural frequency was obtained both from an experimental study and an analytical study. An appropriate vibration condition of a floor with panel heating and noise absorbing systems was evaluated from this study.

  • PDF

Simplified finite element modelling of non uniform tall building structures comprising wall and frame assemblies including P-Δ effects

  • Belhadj, Abdesselem Hichem;Meftah, Sid Ahmed
    • Earthquakes and Structures
    • /
    • 제8권1호
    • /
    • pp.253-273
    • /
    • 2015
  • The current investigation has been conducted to examine the effect of gravity loads on the seismic responses of the doubly asymmetric, three-dimensional structures comprising walls and frames. The proposed model includes the P-${\Delta}$ effects induced by the building weight. Based on the variational approach, a 3D finite element with two nodes and six DOF per node including P-${\Delta}$ effects is formulated. Dynamic and static governing equations are derived for dynamic and buckling analyzes of buildings braced by wall-frame systems. The influences of P-${\Delta}$ effects and height of the building on tip displacements under Hachinohe earthquake record are investigated through many structural examples.

Contribution of Reinforced Concrete Floor Slabs to Lateral Behavior of Tall Buildings

  • Rehmanjee, Yasmin;Leslie, Benjamin;Lamianski, Dmitri;Chafart, Manuel
    • 국제초고층학회논문집
    • /
    • 제11권1호
    • /
    • pp.25-29
    • /
    • 2022
  • This paper focuses on how the coupling of the columns and walls through the structural slab contributes to the overall stiffness and strength of lateral systems. The rationale and procedures behind the design approach, which may offer a shift from more conventional assumptions made regarding compatibility and connectivity of gravity and lateral structural systems, will be introduced. The impacts on serviceability and strength design will be discussed, and observations on key design and analysis approaches will be featured. Mass and stiffness assumptions will also be reviewed. A case study on the topic will be presented describing implementation of slab coupling into engineering of a building project.

Optimization of Heat Exchanger Network in the Steam Assisted Gravity Drainage Process Integration

  • Rho, Seon-Gyun;Yuhang, Zhang;Hwang, InJu;Kang, Choon-Hyoung
    • International Journal of Advanced Culture Technology
    • /
    • 제8권2호
    • /
    • pp.260-269
    • /
    • 2020
  • The Steam Assisted Gravity Drainage (SAGD) process is an enhanced method to extract oil from bitumen which involves surface and central process facilities. This paper describes the Central Process Facilities (CPF) of SAGD and proposes several retrofit plans to the Heat Exchanger Network (HEN). In this approach, the process integration scheme is applied to estimate the energy saving in HENs, and various cases are modeled in favor of a commercial simulator. Throughout this work, a minimum approach temperature of 10℃ is assumed. The results reveal that, due to the HEN optimization using process integration, the heating and cooling duties can be reduced to 29.68MW and 1.886MW, respectively. Compared with the Husky case, all cases considered in this study indicate a potential reduction of at least 6% in total cost, including investment and operation costs.

중량 최소화를 위한 RC 빌딩의 구조 최적설계 (Structural Optimization of a RC Building for Minimizing Weight)

  • 박창현;안희재;최동훈;정철규
    • 한국전산구조공학회논문집
    • /
    • 제23권5호
    • /
    • pp.501-507
    • /
    • 2010
  • 본 논문에서는 중력하중 및 풍하중, 지진하중을 받는 지상 8층, 지하 3층의 RC(Reinforced Concrete) 빌딩 시공에 필요한 부재의 재료비를 줄이기 위해 중량을 감소시키는 구조 최적설계를 수행한다. 이를 위해 설계요구사항을 바탕으로 부재의 부피를 최소화하는 설계변수값을 찾기 위한 설계문제를 정식화한다. 최적설계 수행을 위해 상용 PIDO(Process Integration and Design Optimization) 툴인 PIAnO(Process Integration, Automation and Optimization)에서 제공하는 다양한 설계기법들을 이용한다. 먼저 실험계획법(Design of Experiments; DOE)을 이용하여 실험계획을 세우고, 실험점에 따라 건축분야 범용 구조해석 프로그램인 MIDAS Gen을 사용하여 구조해석을 수행한다. 그리고 해석결과를 바탕으로 각 응답에 대한 근사모델을 생성한 후 근사모델의 예측성능을 평가한다. 예측성능이 검증된 근사모델과 최적화기법을 이용하여 최적설계를 수행하고, 설계조건을 만족하면서 부재의 부피를 최소화하는 최적 설계변수값을 도출함으로서 본 논문에서 제안된 설계방법의 유효성을 보이고자 한다.

초고층 건물의 기둥축소와 지진하중에 대한 구조적 영향 (A Column Shortening on High-Rise Building and Structural Effect under seismic load)

  • 정은호;김희철
    • 한국지진공학회논문집
    • /
    • 제1권3호
    • /
    • pp.59-68
    • /
    • 1997
  • 대도시에서 초고층 건물의 필요성은 구조 기술자에게 새로운 문제를 안겨주었다. 기둥축소의 효과는 설계 및 시공에 있어 특별한 주의를 요구한다. 기둥의 축소는 칸막이, 마감, 그리고 설비체계와 같이 수직하중을 지탱하도록 고려되어 있지 않은 비구조적인 요소에 영향을 미친다. 또한 각 기둥의 축소량 차이는 주위의 슬래브 및 보와 같은 부재들을 경사지게 한다. 축소량을 예측하는 목적은 부등 축소량의 차이를 미리 보정하는데 있다. 본 연구는 부동 축소량에 의한 주구조부재의 영향에 대한 내용을 다루었다. 자중으로 인해 초지 수직변위를 갖는 52층 철근콘크리트 구조물에 지진하중을 적용하여 구조물에 미치는 영향을 평가하였다. 각 수직구조요소에 대한 축소량은 전산화된 기둥축소 해석 프로그램을 이용하여 예측되었으며 지진하중으로 인한 축소량이 보정된 구조물과 보정되지 않은 구조물 사이의 응력을 조사하였다.

  • PDF

Prediction of Time-dependent Lateral Movement Induced by Differential Shortening in Tall Buildings Using Construction Stage Analysis

  • Ha, Taehun;Kim, Sangdae;Lee, Sungho
    • 국제초고층학회논문집
    • /
    • 제6권1호
    • /
    • pp.11-19
    • /
    • 2017
  • High-rise buildings move during construction due to time-dependent material properties of concrete (creep and shrinkage), construction sequences, and structural shapes. The building movements, including vertical and horizontal displacements, result from the sum of axial and lateral deformation of vertical members at each level. In addition to the vertical shortenings, the lateral movement induced by differential shortening can have adverse effects on the construction tolerance and serviceability of non-structural elements such as elevators and curtain walls. In this study a construction stage analysis method is developed to predict lateral movement induced by shortening, including the effect of creep and shrinkage. The algorithm of construction stage analysis is combined with the FE analysis program. It is then applied to predict lateral movement of a 58-story reinforced concrete building that was constructed in Kuala Lumpur, Malaysia. Gravity induced lateral movement of this building is predicted by the construction stage analysis. A field three-dimensional laser scanning survey is carried out to verify the prediction results, and satisfactory agreement is obtained.

Dynamic Analysis of AP1000 Shield Building Considering Fluid and Structure Interaction Effects

  • Xu, Qiang;Chen, Jianyun;Zhang, Chaobi;Li, Jing;Zhao, Chunfeng
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.246-258
    • /
    • 2016
  • The shield building of AP1000 was designed to protect the steel containment vessel of the nuclear reactor. Therefore, the safety and integrity must be ensured during the plant life in any conditions such as an earthquake. The aim of this paper is to study the effect of water in the water tank on the response of the AP1000 shield building when subjected to three-dimensional seismic ground acceleration. The smoothed particle hydrodynamics method (SPH) and finite element method (FEM) coupling method is used to numerically simulate the fluid and structure interaction (FSI) between water in the water tank and the AP1000 shield building. Then the grid convergence of FEM and SPH for the AP1000 shield building is analyzed. Next the modal analysis of the AP1000 shield building with various water levels (WLs) in the water tank is taken. Meanwhile, the pressure due to sloshing and oscillation of the water in the gravity drain water tank is studied. The influences of the height of water in the water tank on the time history of acceleration of the AP1000 shield building are discussed, as well as the distributions of amplification, acceleration, displacement, and stresses of the AP1000 shield building. Research on the relationship between the WLs in the water tank and the response spectrums of the structure are also taken. The results show that the high WL in the water tank can limit the vibration of the AP1000 shield building and can more efficiently dissipate the kinetic energy of the AP1000 shield building by fluid-structure interaction.

Validating the Structural Behavior and Response of Burj Khalifa: Synopsis of the Full Scale Structural Health Monitoring Programs

  • Abdelrazaq, Ahmad
    • 국제초고층학회논문집
    • /
    • 제1권1호
    • /
    • pp.37-51
    • /
    • 2012
  • New generation of tall and complex buildings systems are now introduced that are reflective of the latest development in materials, design, sustainability, construction, and IT technologies. While the complexity in design is being overcome by the availability and advances in structural analysis tools and readily advanced software, the design of these buildings are still reliant on minimum code requirements that yet to be validated in full scale. The involvement of the author in the design and construction planning of Burj Khalifa since its inception until its completion prompted the author to conceptually develop an extensive survey and real-time structural health monitoring program to validate all the fundamental assumptions mad for the design and construction planning of the tower. The Burj Khalifa Project is the tallest structure ever built by man; the tower is 828 meters tall and comprises of 162 floors above grade and 3 basement levels. Early integration of aerodynamic shaping and wind engineering played a major role in the architectural massing and design of this multi-use tower, where mitigating and taming the dynamic wind effects was one of the most important design criteria established at the onset of the project design. Understanding the structural and foundation system behaviors of the tower are the key fundamental drivers for the development and execution of a state-of-the-art survey and structural health monitoring (SHM) programs. Therefore, the focus of this paper is to discuss the execution of the survey and real-time structural health monitoring programs to confirm the structural behavioral response of the tower during construction stage and during its service life; the monitoring programs included 1) monitoring the tower's foundation system, 2) monitoring the foundation settlement, 3) measuring the strains of the tower vertical elements, 4) measuring the wall and column vertical shortening due to elastic, shrinkage and creep effects, 5) measuring the lateral displacement of the tower under its own gravity loads (including asymmetrical effects) resulting from immediate elastic and long term creep effects, 6) measuring the building lateral movements and dynamic characteristic in real time during construction, 7) measuring the building displacements, accelerations, dynamic characteristics, and structural behavior in real time under building permanent conditions, 8) and monitoring the Pinnacle dynamic behavior and fatigue characteristics. This extensive SHM program has resulted in extensive insight into the structural response of the tower, allowed control the construction process, allowed for the evaluation of the structural response in effective and immediate manner and it allowed for immediate correlation between the measured and the predicted behavior. The survey and SHM programs developed for Burj Khalifa will with no doubt pioneer the use of new survey techniques and the execution of new SHM program concepts as part of the fundamental design of building structures. Moreover, this survey and SHM programs will be benchmarked as a model for the development of future generation of SHM programs for all critical and essential facilities, however, but with much improved devices and technologies, which are now being considered by the author for another tall and complex building development, that is presently under construction.

준불연 외단열시스템의 역학적 특성에 관한 연구 (Mechanical Properties of External Thermal Insulation Composite System with Quasi-Non-Combustible Performance)

  • 최기선;하수경;오근영;박금성;류화성
    • 한국건축시공학회지
    • /
    • 제21권5호
    • /
    • pp.507-518
    • /
    • 2021
  • 외단열시스템에서 준불연 성능을 확보한 부착식 탄산칼슘계 복합단열판은 효과적인 단열성능과 화재안전성을 강화한 것으로, 본 연구에서는 준불연 복합단열판을 대상으로 부착식 준불연 외단열시스템의 구조설계 기초데이터를 확보하기 위하여 복합단열판 및 구성재의 역학적 시험을 수행하였다. 국내외 시험규격을 참조하여 시험체를 제작하였으며, 인장강도, 압축강도, 굴곡강도, 전단강도를 시험 평가하였다. 시험결과로부터 준불연 복합단열판의 강도특성치를 도출하였고, 현행 KS M ISO 4898에서 제시하는 최소 요구물성을 확보하고 있는 것을 검증하였다. 또한, 본 연구에서 사용한 준불연 외단열시스템은 지속적 중량 하중을 받지 않는 벽체의 외단열시스템으로 사용이 가능한 것을 확인하였다.