• 제목/요약/키워드: granular activated carbon (GAC)

검색결과 152건 처리시간 0.023초

Bacterial Community Structure Shifted by Geosmin in Granular Activated Carbon System of Water Treatment Plants

  • Pham, Ngoc Dung;Lee, Eun-Hee;Chae, Seon-Ha;Cho, Yongdeok;Shin, Hyejin;Son, Ahjeong
    • Journal of Microbiology and Biotechnology
    • /
    • 제26권1호
    • /
    • pp.99-109
    • /
    • 2016
  • We investigated the relation between the presence of geosmin in water and the bacterial community structure within the granular activated carbon (GAC) system of water treatment plants in South Korea. GAC samples were collected in May and August of 2014 at three water treatment plants (Sungnam, Koyang, and Yeoncho in Korea). Dissolved organic carbon and geosmin were analyzed before and after GAC treatment. Geosmin was found in raw water from Sungnam and Koyang water treatment plants but not in that from Yeoncho water treatment plant. Interestingly, but not surprisingly, the 16S rRNA clone library indicated that the bacterial communities from the Sungnam and Koyang GAC systems were closely related to geosmin-degrading bacteria. Based on the phylogenetic tree and multidimensional scaling plot, bacterial clones from GAC under the influence of geosmin were clustered with Variovorax paradoxus strain DB 9b and Comamonas sp. DB mg. In other words, the presence of geosmin in water might have inevitably contributed to the growth of geosmin degraders within the respective GAC system.

Enhancement of Efficiency of Activated Carbon Impregnated Chitosan for Carbon Dioxide Adsorption

  • Patkool, Chaiwat;Chawakitchareon, Petchporn;Anuwattana, Rewadee
    • Environmental Engineering Research
    • /
    • 제19권3호
    • /
    • pp.289-292
    • /
    • 2014
  • The effect of carbon dioxide ($CO_2$) on global warming is serious problem. The adsorption with solid sorbents is one of the most appropriate options. In this study, the most interesting adsorbent is granular activated carbon (GAC). It is suitable material for $CO_2$ adsorption because of its simple availability, many specific surface area, and low-cost material. Afterwards, GAC was impregnated with chitosan solution as impregnated granular activated carbon (CGAC) in order to improve the adsorption capacity of GAC. This research aims to compare the physical and chemical characteristics of GAC and CGAC. The experiment was carried out to evaluate the efficiency of $CO_2$ adsorption between GAC and CGAC. The results indicated that the iodine number of GAC and CGAC was 137.17 and 120.30 mg/g, respectively. The Brunauer-Emmett-Teller results (BET) of both GAC and CGAC show that specific surface area was 301.9 and $531.3m^2/g$, respectively; total pore volume was 0.16 and $0.29cm^3/g$, respectively; and mean diameter of pore was 2.18 and 2.15 nm, respectively. Finally, the $CO_2$ adsorption results of both GAC and CGAC in single column how the maximum adsorption capacity was 0.17 and 0.25 mol/kg, respectively; how degeneration time was 49.6 and 80.0 min, respectively; and how the highest efficiency of $CO_2$ adsorption was 91.92% and 91.19%, respectively.

마이크로파 조사에 따른 금속이 담지 된 활성탄의 특성 연구 (A Study on the Characteristics of Activated Carbons Supported Metal by Microwave Irradiation)

  • 김성욱;김정배;최성우
    • 한국환경과학회지
    • /
    • 제18권5호
    • /
    • pp.501-508
    • /
    • 2009
  • In this study, the characteristics of granular activated carbon (GAC) supported metal was investigated in an area influenced by flame discharge and temperature variation during irradiating microwave. The modified GAC was formulated by impregnating metal hydroxides of nickel (Ni/GAC), barium (Ba/GAC), copper (Cu/GAC), zinc (Zn/GAC), cobalt (Co/GAC) and lanthanum (La/GAC). Ba/GAC was selected as it showed lack of spark discharge and temperature increasing aspects. Comparison of adsorption and desorption amount of GAC and Ba/GAC showed that adsorption and desorption rate of the GAC were higher than those of Ba/GAC. The results show that the presence of barium can decrease adsorption/desorption rate because of plugging pore of GAC. Toluene regeneration rate of Ba/GAC was better than that of GAC due to barium loading. Finally, GAC with barium can be controled a rapid increasing temperature and spark discharge, increased the regeneration rate of toluene during desorption by irradiating microwave.

DOM의 분자량과 크기분포에 따른 입상활성탄 공정의 평가 (Evaluation of Granular Activated Carbon Process Focusing on Molar mass and size distribution of DOM)

  • 채선하;이경혁
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.31-38
    • /
    • 2008
  • The primary objective of this study was to evaluate the variation of the molecular size distribution by granular activated carbon (GAC) adsorption. GAC adsorption was assessed by using the rapid small-scale column test (RSSCT) and high-performance size-exclusion chromatography (HPSEC) was used to analyze the molecular size distribution (MSD) in the effluent of GAC column. RSSCT study suggested that GAC adsorption exhibited excellent interrelationship between dissolved organic carbon (DOC) breakthrough and MSD as function of bed volumes passed. After GAC treatment, the nonadsorbable fraction which was about 25percents of influent DOC corresponded to the hydrophilic (HPI) natural organic carbon (NOM) of NOM fractions and was composed entirely of <300 molecular weight (MW) in the HPSEC at the initial stage of the RSSCT operation. The dominant MW fraction in the source water was 1,000~5,000daltons. At the bed volumes 2,500, MW <500 of GAC treated water was risen rather than it of source water. After the bed volumes 7,300 of operation, the MW 1,000~3,000 fraction was closed to about 80percents of DOC found in the GAC influent. The Number-average molecular weight (Mn) value determined using HPSEC for the effluent of GAC column was gently increased as DOC breakthrough progress. The quotient p(Mw/Mn) can be used to estimate the degree of polydispersity was shown greatest value for the GAC effluent at the initial stage of the RSSCT operation.

Humic acid 제거를 위한 국산 입상활성탄의 흡착성능 평가에 관한 연구 (A Study on Evaluation of Adsorption Performance of Humic Acid on Granular Activated Carbon)

  • 신성교;김종구;박청길
    • 한국환경과학회지
    • /
    • 제2권1호
    • /
    • pp.73-81
    • /
    • 1993
  • Adsorption process using granular activated carbon(GAC) has been considered as one of the most effective water treatment technologies to remove humic acid which is recon- niEed as trihalomethane(THM) precursor in chlorination. To design the most effective GAC process, it is necessary to conduct the test of adsor- ption performance by means of isothem, batch rate and column studies and to select the most effective activated carbon according to raw materials of GAC - lignite and coconut shell. The objective of this study is to investigate the adsorption performance of humid acid on two activated carbons - lignite activated carbon(LAC) and coconut shell activated car- bon(CAC) made in Korea. It is available to represent UV-abs and trihalomethane formation potential(THMFP) as concentration of humic acid due to good relationship. The adsorption capacity of humid acid is not concerned with surface area of activated carbon but with pore size related to about $100{\AA}$, and then LAC forming at the extent of mesopore is found to be eight times more effective in adsorption capacity than CAC forming at micropore. The adsorption capacity of LAC and CAC is better at pH 5.5 than at pH 7. Pore and surface diffusion coefficients calculated from the diffusion model are $7.61\times10^{-13}m^2/sec$, $3.52\times10^{-15}m^2/sec$ for CAC, and $3.38\times10^{-12}m^2$/sec and $Ds=1.48{\times}10^{-15}m^2/sec$ for GAC respectively. From the results of column test it shows that the performance of LAC is also better than CAC and the optimal EBCT(Empty Bed Contact Time) is 4.52min. and activated carbon removes selectively the components of humic acid to be easily formed to THM.

  • PDF

상향류 혐기성 슬러지 블랭킷 반응조를 이용한 침출수 처리시 입상 활성탄 및 입상슬러지 첨가의 영향 (Effect of the Addition of Granular Activated Carbon and Granular Sludge on the Performance of Upflow Anaerobic Sludge Blanket Reactors for Treating Leachate)

  • 이채영
    • 유기물자원화
    • /
    • 제16권4호
    • /
    • pp.91-97
    • /
    • 2008
  • 본 연구에서는 상향류 혐기성 블랭킷 반응조를 이용한 침출수 처리시 입상활성탄과 입상슬러지의 첨가가 반응조의 성능에 미치는 영향을 평가하였다. Control 반응조의 경우 식종물질로 혐기성 소화슬러지를 이용하였으며 GAC 반응조와 Granule 반응조의 경우 Control 반응조와 동일 방식으로 식종하였으며 단지 GAC와 입상슬러지를 소량 첨가하였다. Granule 반응조가 초기 운전기간 동안 가장 짧은 순응기간을 보였으며 GAC 반응조의 경우에도 운전초기에 만족할 만한 성능을 보였다. 그러나 활성탄의 흡착능이 소모됨에 따라 유출수 COD 농도가 점차 증가하는 경향을 보였다. 반응조가 안정화된 후 GAC 반응조가 다른 반응조에 비해 약간 우수한 결과를 보였으며 모든 반응조의 COD 제거율은 수리학적 체류시간 1일에서 90% 이상을 나타내었다. 특히 GAC 반응조의 경우 COD 제거율의 변화 없이 유기물 부하 $4.0{\sim}8.2kg\;COD/m^3.d$에서 95%를 유지하였다. 소량의 입상슬러지 첨가에 의해 초기 운전기간을 단축시킬 수 있었으며 처리효율은 GAC 첨가에 의해 향상되는 것으로 나타났다.

  • PDF

표면 처리에 따른 입상활성탄 및 활성탄소섬유의 중금속 흡착 (Adsorption of heavy metal ions onto a surface treated with granular activated carbon and activated carbon fibers)

  • 강광철;권수한;김승수;최종원;전관식
    • 분석과학
    • /
    • 제19권4호
    • /
    • pp.285-289
    • /
    • 2006
  • 본 연구에서는 산 표면 처리한 입상 활성탄(GAC)과 활성 탄소섬유(ACF)에 의한 $Pb^{2+}$$Ni^{2+}$ 이온의 흡착 특성을 고찰하였다. 산 표면 처리용액으로는 1.0 M 질산 용액을 사용하였다. GAC와 ACF의 표면특성분석은 pH, 등전점(pHpzc), 그리고 원소분석기를 사용하였으며, 비표면적과 기공구조는 77K에서 $N_2$ 등온흡착 방법으로 측정하였다. 본 실험결과 GAC 와 ACF를 산으로 표면 처리한 경우 산소를 포함한 작용기가 증가하였다. 이처럼 산 표면 처리에 의해 증가된 표면 작용기에 따른 GAC 및 ACF의 기공이 막힘에도 불구하고, acidic-ACF > untreated-ACF > acdic-GAC > untreated-GAC 순으로 중금속 흡착능이 증가하였다.

마이크로파 조사에 따른 개질화 활성탄의 온도특성 및 벤젠흡착 (Temperature Characteristics of the Modified GAC by Microwave Irradiation and Benzene Adsorption)

  • 최성우;김윤갑
    • 한국환경과학회지
    • /
    • 제15권6호
    • /
    • pp.579-586
    • /
    • 2006
  • The purposes of this paper were to monitor the temperature rising courses and spark discharge of the modified granular activated carbon (GAC) by microwave (MW) irradiation and to evaluate absorption of benzene. The GAC coated on $SiO_2$, boron, talc, ferrite was named as the modified GAC. Thermal and spark discharge measurement of virgin GAC and modifed GAC has been carried out using a MW device operating at 2450 MHz under various energy conditions. The results of this paper as follows. First, the modified GAC is more efficient than the virgin GAC in temperature control. Temperature gradient of the modified GAC is more lower than that of virgin GAC. The temperature gradient of GAC was observed in the following order : virgin GAC, Mn-Zn ferrite/GAC, Ni-Zn ferrite,/GAC, $SiO_2/GAC$, Boron/GAC, Talc/GAC. Second, the spark discharge of the modified GAC was diminished, compared with that of virgin GAC. Because of its excellent electrical insulating properties, the coating material prevents the spark discharge. Finally, the benzene adsorption capacity of the modified GAC decreased due to diminishing of adsorption site by the coating material. Considering the temperature gradient and spark discharge of GAC, the GAC coated $SiO_2$ would be appropriate absorbent under irradiation of MW.

입상활성탄 재생온도에 따른 정수처리 효율 평가 (Evaluation of Drinking Water Treatment Efficiency according to Regeneration Temperatures of Granular Activated Carbon (GAC))

  • 김상구;손희종;정종문;류동춘;유평종
    • 한국환경과학회지
    • /
    • 제24권9호
    • /
    • pp.1163-1170
    • /
    • 2015
  • This study carried out continuous column test for estimating the regeneration efficiency with regeneration times and temperatures. More times regenerated granular activated carbon (GAC) has more ash in the GAC and has less apparent density. Two times regenerated GAC ($2^{nd}$ re-GAC) could removed the Trihalomethanes (THMs) in the water for the first two week after starting continuous column test, on the other hand five times regenerated GAC ($5^{th}$ re-GAC) did not have adsorption capacity. The THMs concentration in the effluent was almost equal or higher than that of influent at the first time of continuous column test. $2^{nd}$ re-GAC showed much more DOC adsorption capacity than $5^{th}$ re-GAC and the GAC which was regenerated with $700^{\circ}C$ had highest DOC removal efficiency among the GACs with 600, 700, 800, $900^{\circ}C$ regeneration temperatures. It is anticipated the cost of GAC regeneration could be saved more 100 million won by reducing the furnace temperature of 3rd~4th and 5th~6th about $150^{\circ}C$ compared to the current regeneration condition.

Utilization of Element-doping Titania-impregnated Granular Activated Carbon in a Plug-flow System for Removal of BTEX

  • Jo, Wan-Kuen;Shin, Seung-Ho;Hwang, Eun-Song;Yang, Sung-Bong
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권3호
    • /
    • pp.177-188
    • /
    • 2010
  • The use of an activated carbon (AC) system alone has the limitation that the pollutants are not eliminated but only transferred to another phase with the consumed AC becoming hazardous waste itself. Therefore, the present study investigated the feasibility of using a combined system of granular AC (GAC) with S-doped visible-light-induced $TiO_2$ (GAC/S-doped $TiO_2$) to clean monocyclic aromatic hydrocarbons (MAHs) with concentrations at $\leq$ 3 mg $m^{-3}$, using a continuous air-flow reactor. This study conducted three different experiments: an adsorption test of pure GAC and GAC/S-doped $TiO_2$; a long-term adsorptional photocatalytic (AP) activity test of GAC/S-doped $TiO_2$; and an AP activity test of GAC/S-doped $TiO_2$ under different conditions. For the AP activity test, three parameters were evaluated: various weights of GAC/S-doped $TiO_2$ (0.9, 4.4, and 8.9 g); various flow rates (FRs) (0.5, 1 and 2 L $min^{-1}$); and various input concentrations (ICs) of the target MAHs (0.1, 1, 2 and 3 mg $m^{-3}$). The adsorption efficiencies were similar for the pure GAC and GAC/S-doped $TiO_2$ reactors, suggesting that S-doped $TiO_2$ particles on GAC surfaces do not significantly interfere with the adsorption capacity of GAC. Benzene exhibited a clear AP activity, whereas no other target MAHs did. In most cases, the AP efficiencies for the target MAHs did not significantly vary with an increase in weight, thereby suggesting that, under the weight range tested in this study, the weights or FRs are not important parameters for AP efficiency. However, ICs did influence the AP efficiencies.