• Title/Summary/Keyword: good selectivity

Search Result 340, Processing Time 0.025 seconds

A Novel Iron(III) Selective Membrane Electrode Containing a Tripodal Polycatacholamine as Sensor

  • Bera, Rati Kanta;Sahoo, Suban K;Baral, Minati;Kanungo, B.K.
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.10
    • /
    • pp.3592-3596
    • /
    • 2011
  • A novel poly(vinylchloride)-based membrane sensor using $N^1$,$N^3$,$N^5$-tris(2-(2,3-dihydroxybenzylamino)-ethyl)cyclohexane-1,3,5-tricarboxamide (CYCOENCAT, L) as ionophore has been prepared and explored as $Fe^{3+}$ selective electrode. The membrane electrode composed of ionophore, poly(vinylchloride) and o-nitropheyloctyl ether in the optimum ratio 4:33:63 gave excellent potentiometric response characteristics, and displayed a linear log[$Fe^{3+}$] versus EMF response over a wide concentration range of $1.0{\times}10^{-5}-1.0{\times}10^{-1}$ M with super nernstian slope of 28.0 mV/decade and the detection limit of $8.0{\times}10^{-6}$ M. The proposed ion selective electrode showed fast response time (< 15 s), wide pH range (3.0-7.0), high non-aqueous tolerance (up to 20%) and adequate long life time (120 days). It also exhibited very good selectivity for $Fe^{3+}$ relative to a wide variety of alkali, alkaline earth, transition and heavy metal ions. Further, the analytical applicability of the sensor was tested as an indicator electrode in the potentiometric titration of $Fe^{3+}$ with EDTA.

Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor

  • Ganjali, M.R.;Norouzi, P.;Alizadeh, T.;Salavati-Niasari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.1
    • /
    • pp.68-72
    • /
    • 2007
  • A new PVC membrane potentiometric sensor that is highly selective to Hg2+ ions was prepared, using bis(2-hydroxybenzophenone) butane-2,3-dihydrazone (HBBD) as an excellent hexadendates neutral carrier. The sensor works satisfactorily in the concentration range of 1.0 × 10-6 to 1.0 × 10-1 mol L-1 (detection limit 4 × 10-7 mol L-1) with a Nernstian slope of 29.7 mV per decade. This electrode showed a fast response time (~8 s) and was used for at least 12 weeks without any divergence. The sensor exhibits good Hg2+ selectivity for a broad range of common alkali, alkaline earth, transition and heavy metal ions (lithium, sodium, potassium, magnesium, calcium, copper, nickel, cobalt, zinc, cadmium, lead and lanthanum). The electrode response is pH independent in the range of 1.5-4.0. Furthermore, the developed sensor was successfully used as an indicator electrode in the potentiometric titration of mercury ions with potassium iodide and the direct determination of mercury in some binary and ternary mixtures.

Polymeric Membrane and Solid Contact Electrodes Based on Schiff Base Complexes of Co(III) for Potentiometric Determination of Perchlorate Ions

  • Soleymanpour, Ahmad;Hanifi, Abdolghafoor;Kyanfar, Ali Hossein
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.9
    • /
    • pp.1774-1780
    • /
    • 2008
  • New PVC based polymeric membrane electrodes (PME) and coated glassy carbon electrodes (CGCE) based on synthesized Schiff base complexes of Co(III); [Co(Salen)$(PBu_3)_2$]$ClO_4$, [Co($Me_2$Salen)$(PBu_3)_2$]$ClO_4$, [Co(Salen)$(PBu_3)H_2O$]$ClO_4$; as anion carriers for potentiometric determination of $ClO_4\;^-$were studied. The PME and also CGCE electrodes prepared with [Co(Me2Salen)$(PBu_3)_2$]$ClO_4$ showed excellent response characteristics to perchlorate ions. The electrodes exhibited Nernstian responses to $ClO_4\;^-$ ions over a wide concentration range with low detection limits ($1.0 {\times} 10^{-6}\;mol\;L^{-1}$ for PME and $9.0 {\times} 10^{-7}\;mol\;L^{-1}$ for CGCE). The electrodes possess fast response time, satisfactory reproducibility, appropriate lifetime and, most importantly, good selectivity toward $ClO_4\;^-$ relative to a variety of other common inorganic anions. The potentiometric response of the electrodes is independent of the pH in the pH range 2.5-8.5. The proposed sensors were used in potentiometric determination of perchlorate ions in mineral water and urine samples. The interaction of the ionophore with perchlorate ions was shown by UV/Vis spectroscopy.

Surface-functionalized Hexagonal Mesoporous Silica Supported 5-(4-Carboxyphenyl)-10,15,20-triphenyl Porphyrin Manganese(III) Chloride and Their Catalytic Activity

  • Zhang, Wei-Jie;Jiang, Ping-Ping;Zhang, Ping-Bo;Zheng, Jia-Wei;Li, Haiyang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.4015-4022
    • /
    • 2012
  • Manganese(III) 5-(4-carboxyphenyl)-10,15,20-triphenyl porphyrin chloride (Mn(TCPP)Cl) was grafted through amide bond on silica zeolite Y (HY), zeolite beta ($H{\beta}$) and hexagonal mesoporous silica (HMS). XRD, ICP-AES, $N_2$ physisorption, SEM, TEM, FTIR and thermal analysis were employed to analyse these novel heterogeneous materials. These silica supported catalysts were shown to be used for epoxidation and good shape selectivity was observed. The effect of support structure on catalytic performance was also discussed. The catalytic activity remained when the catalysts were recycled five times. The energy changes about epoxidation of alkenes by $NaIO_4$ and $H_2O_2$ were also computationally calculated to explain the different catalytic efficiency.

Novel Thallium(I)-Selective Membrane Electrode Based on a Podal Ligand

  • Ganjali, Mohammad Reza;Pourjavid, Mohammad Reza;Mouradzadegun, Arash;Hosseini, Morteza;Mizani, Farhang
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.11
    • /
    • pp.1585-1589
    • /
    • 2003
  • A PVC-based membrane electrode for thallium(I) ions based on 1,21,23,25-tetramethyl-2,20: 3,19-dimetheno-[H, 2] H, 23H, 25H-bis-[1,3] dioxocino[5,4-i:5',4'-i] benzo [1,2-d: 5.4-d'] bis [1,3] benzodioxocin(II) has been prepared. The electrode displays a linear dynamic range of $1.0{\times}10^{-1}-1.0{\times}10^{-5}$ M, with a Nernstian slope of $59.8{\pm}0.2\;mV\;{decad^-1}$, and a detection limit $5.0{\times}10^{-6}$ M. It has a very fast response time of<10 s and can be used for at least ten weeks without a considerable divergence in potentials. This electrode revealed comparatively good selectivity with respect to alkali, alkaline earth, and some transition and heavy metal ions and was effective in a pH range of 2.0-10.0. It was used as an indicator electrode in potentiometric titration of thallium ion with sulfide ion.

Electrochemical Investigation of Acetaminophen with a Carbon Nano-tube Composite Film Electrode

  • Li, Chunya;Zhan, Guoqing;Yang, Qingdan;Lu, Jianjie
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.11
    • /
    • pp.1854-1860
    • /
    • 2006
  • Electrochemical behaviors of acetaminophen at a muti-wall carbon nano-tube composite film modified glassy carbon electrode were investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Compared with that obtained at the unmodified electrode, the peak currents were enhanced significantly, and the oxidation peak shifted towards more negative potential with the reduction peak shifted positively. The peak-to-peak separation turned narrow, and suggested that the reversibility was improved greatly. Experimental parameters, such as scan rate, pH and accumulation conditions were optimized. It was found that a maximum current response can be obtained at pH = 5.0 after accumulation at -0.50 V for 80 s. The oxidation peak current was found to be linearly related to acetaminophen concentration over the range of $5.0{\times}10^{-7}\;\sim\;1.0{\times}10^{-4}$ mol $L^{-1}$ with a detection limit of $5.0{\times}10^{-8} $mol $L^{-1}$. A convenient and sensitive electrochemical method was developed for the determination of acetaminophen in a commercial paracetamol oral solution. Its practical application demonstrated that it has good selectivity and high sensitivity.

The Potentiometric Performances of Membrane Electrodes Based on Tetracycline Antibiotics (테트라싸이크린 항생제를 담체로 이용한 막전극의 전위차 특성)

  • Baek, Jong-Gyu;Rhee, In-Sook;Paeng, Ki-Jung
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.3
    • /
    • pp.132-134
    • /
    • 2006
  • The main component governing selectivity in ion-selective electrodes and optodes is the ionophore. For this reason, a member of natural products that possess selective ion-binding properties have long been sought after. By applying this principle, the performance of tetracycline used as neutral carriers for cation selective polymeric membrane electrode was investigated. The cation ion-selective electrode based on tetracycline gave a good Nernstian response of 26.6 mV per decade for calcium ion in the activity range $1x10^{-6}M$ to $1x10^{-2}M$ with and without lipophilic additives. The optimized cation ion-selective membrane electrodes displayed very comparable potentiometric responses to various mono and di-valent cations of alkali and alkaline earth metal ions except $Mg^{2+}$.

An Optimization of Tungsten Plug Chemical Mechanical Polishing(CMP) using the Different Sets of Slurry and Pad (슬러리와 패드변화에 따른 텅스텐 플러그 CMP 공정의 최적화)

  • 김상용;서용진;이우선;이강현;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.568-574
    • /
    • 2000
  • We have been optimized tungsten(W) plug CMP(chemical mechanical polishing) characteristics using two different kinds of component of slurry and two different kinds of pad which have different hardness. The comparison of oxide film roughness on around W plug after polishing has been carried out. And W plug recess for consumable sets and dishing effect at dense area according to the rate of over-polishing has been investigated. Also the analysis of residue on surface after cleaning have been performed. As a experimental result we have concluded that the consumable set of slurry A and hard pad was good for W plug CMP process. After decreasing the rate of chemical reaction of silica slurry and adding two step buffering we could reduce the expanding of W plug void however we are still recognizing to need a more development for those kinds of CMP consumables.

  • PDF

Behavior of Surface Compositions in CMP Process for PZT Thin Fims (PZT 박막의 CMP 공정중 표면 조성 거동)

  • Ko, Pil-Ju;Kim, Nam-Hoon;Lee, Woo-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1448-1449
    • /
    • 2006
  • Pb(Zr,Ti)$O_3$ is one of the most attractive ferroelectric materials for realizing the FeRAM due to its higher remanant polarization and the ability to withstand higher coercive fields. Generally, the ferroelectric materials were patterned by a plasma etching process for high-density FeRAM. The applicable possibility of CMP process to pattern Pb(Zr,Ti)$O_3$ instead of plasma etching process was investigated in our previous study for improvement of an angled sidewall which prevents the densification of ferroelectric memory and is apt to receive the plasma damage. Our previous study showed that good removal rate with the excellent surface roughness compared to plasma etching process were obtained by CMP process for the patterning of Pb(Zr,Ti)$O_3$. The suitable selectivity to TEOS without any damage to the structural property of Pb(Zr,Ti)$O_3$ was also guaranteed. In this study, the removal mechanism of $Pb_{1.1}(Zr_{0.52}Ti_{0.48})O_3$ coated by sol-gel method was investigated. Surface analysis of polished specimens at the best and worst conditions was carried out by XPS.

  • PDF

Improved hydrogen sensing characteristics of flat type catalytic combustible hydrogen gas sensor of micro-structure (평판형 접촉연소식 마이크로 수소센서의 감지특성 향상)

  • Kim, Chan-Woo;Gwak, Ji-Hye;Chun, Il-Su;Han, Sang-Do;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.202-206
    • /
    • 2009
  • Flat type catalytic combustible hydrogen sensors were fabricated using platinum micro-heaters and sensing material pastes. The platinum micro-heater was formed on an alumina substrate by sputtering method. The paste for the sensing materials was prepared using ${\gamma}-Al_2O_3$ 30 wt%, $SnO_2$ 35 wt%, and Pd/Pt 30 wt% and coated on the platinum micro-heater. The sensing performances were tested for the prepared sensors with different substrate sizes. The micro catalytic combustible hydrogen sensors showed quick response time, high reliability, and good selectivity against various gases(CO, $C_3H_8,\;CH_4$) at low operating temperature of $156^{\circ}\C$.