• Title/Summary/Keyword: good pair

Search Result 227, Processing Time 0.026 seconds

Pair Correlation Analysis of Reaction-Diffusion Halftoning (반응-확산 하프토닝의 공간영역신호 분석)

  • Jho, Chueng-woon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.648-653
    • /
    • 2018
  • Analysis of a specific wavelength band of a video signal is an old research field. However, studies on the analysis of signals having the characteristics of a specific wavelength band or the generation of samples have been conducted actively in recent years. In this paper, we analyze the signal of digital halftoned image. The interpretation of halftoning in terms of signals was first made by Ulichney. We have come to the view that the signal characteristics between pixels used for half toning are good for blue noise. Lau has developed a halftoning method that uses green-noise characteristics by using output-dependent feedback as an error diffusion method. Jho has developed a method for producing halftoned images using a reaction diffusion model. In this paper, we analyze reaction diffusion halftoning in terms of signal to show green noise and compare it with existing green noise half tone.

Design of transistor oscillator for X-band application using a pair of L-shaped monopole slot resonator (한 쌍의 L-형 모노폴 슬롯 공진기를 이용한 X-밴드 트랜지스터 발진기 설계)

  • Lee, Yeong-min;Lee, Young-soon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.1
    • /
    • pp.107-114
    • /
    • 2021
  • In this paper, a planar transistor oscillator for X-band using a newly proposed L-shaped monopole slot resonator is proposed. For planar design, an L-shaped monopole slot with an open-end is used as a resonator for a transistor oscillator. As a result of the simulated design of the resonator in three stages, a high Q value of 1169.84 and a high insertion loss of 49.934 dB were identified. The results of the final design and manufactured oscillator measurements confirmed that the oscillation output is greater than 7 dBm and has good phase noise characteristics of -58 dBc/Hz at 100 kHz offset. The proposed oscillator is planar and has the advantage of being directly applicable to microwave integrated circuit technology. It also has the advantage of being able to reduce its size as it can only be implemented in microstrip form without additional devices such as metal cavities and tuning screws in 3D structures, as in the case of a DRO (dielectric resonance oscillator).

Ginseng extract and ginsenosides improve neurological function and promote antioxidant effects in rats with spinal cord injury: A meta-analysis and systematic review

  • Sng, Kim Sia;Li, Gan;Zhou, Long-yun;Song, Yong-jia;Chen, Xu-qing;Wang, Yong-jun;Yao, Min;Cui, Xue-jun
    • Journal of Ginseng Research
    • /
    • v.46 no.1
    • /
    • pp.11-22
    • /
    • 2022
  • Spinal cord injury (SCI) is defined as damage to the spinal cord that temporarily or permanently changes its function. There is no definite treatment established for neurological complete injury patients. This study investigated the effect of ginseng extract and ginsenosides on neurological recovery and antioxidant efficacies in rat models following SCI and explore the appropriate dosage. Searches were done on PubMed, Embase, and Chinese databases, and animal studies matches the inclusion criteria were selected. Pair-wise meta-analysis and subgroup analysis were performed. Ten studies were included, and the overall methodological qualities were low quality. The result showed ginseng extract and ginsenosides significantly improve neurological function, through the Basso, Beattie, and Bresnahan (BBB) locomotor rating scale (pooled MD = 4.40; 95% CI = 3.92 to 4.88; p < 0.00001), significantly decrease malondialdehyde (MDA) (n = 290; pooled MD = -2.19; 95% CI = -3.16 to 1.22; p < 0.0001) and increase superoxide dismutase (SOD) levels (n = 290; pooled MD = 2.14; 95% CI = 1.45 to 2.83; p < 0.00001). Both low (<25 mg/kg) and high dosage (25 mg/kg) showed significant improvement in the motor function recovery in SCI rats. Collectively, this review suggests ginseng extract and ginsenosides has a protective effect on SCI, with good safety and a clear mechanism of action and may be suitable for future clinical trials and applications.

A Novel RGB Channel Assimilation for Hyperspectral Image Classification using 3D-Convolutional Neural Network with Bi-Long Short-Term Memory

  • M. Preethi;C. Velayutham;S. Arumugaperumal
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.3
    • /
    • pp.177-186
    • /
    • 2023
  • Hyperspectral imaging technology is one of the most efficient and fast-growing technologies in recent years. Hyperspectral image (HSI) comprises contiguous spectral bands for every pixel that is used to detect the object with significant accuracy and details. HSI contains high dimensionality of spectral information which is not easy to classify every pixel. To confront the problem, we propose a novel RGB channel Assimilation for classification methods. The color features are extracted by using chromaticity computation. Additionally, this work discusses the classification of hyperspectral image based on Domain Transform Interpolated Convolution Filter (DTICF) and 3D-CNN with Bi-directional-Long Short Term Memory (Bi-LSTM). There are three steps for the proposed techniques: First, HSI data is converted to RGB images with spatial features. Before using the DTICF, the RGB images of HSI and patch of the input image from raw HSI are integrated. Afterward, the pair features of spectral and spatial are excerpted using DTICF from integrated HSI. Those obtained spatial and spectral features are finally given into the designed 3D-CNN with Bi-LSTM framework. In the second step, the excerpted color features are classified by 2D-CNN. The probabilistic classification map of 3D-CNN-Bi-LSTM, and 2D-CNN are fused. In the last step, additionally, Markov Random Field (MRF) is utilized for improving the fused probabilistic classification map efficiently. Based on the experimental results, two different hyperspectral images prove that novel RGB channel assimilation of DTICF-3D-CNN-Bi-LSTM approach is more important and provides good classification results compared to other classification approaches.

A Study on the Pitch Extraction Improvement Using LSP for the Synthesis of High Speech Quality (고음질 음성합성을 위한 LSP를 이용한 피치검출 성능향상에 관한 연구)

  • Seo, Ji-Ho;Kim, Jong-Kuk;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.69-75
    • /
    • 2010
  • In this paper, the pitch is detected after the elimination of formant ingredients by flattening the spectrum in frequency domain. In order to remove impact of formant and transition frequency in the signal spectrum, formant envelop is made by linear interpolation with any points each sub-band and the spectrum of speech signal is compensated by the reverse of the envelop interpolated linearly after we divide frequency band into several segment based on LSP and detect the points. The experimental result showed the proposed method appeared an outstanding performance in compared with LPC, Cepstrum, Lifter methods. The method reduced the gross error rate 1.30% than the LPC method which appeared a good performance except the proposed method. Also, the proposed method showed low error rate in noise environment.

Experimental Study on Compressive Strength of Concrete Column Retrofitted by Carbon FRP Sheet (탄소섬유시트로 보강된 콘크리트 기둥의 압축성능 평가를 위한 실험연구)

  • Yoo, Youn-Jong;Lee, Kyoung-Hun;Kim, Heecheul;Lee, Young-Hak;Hong, Won-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.119-126
    • /
    • 2008
  • In 1980 and 1990's most of residential buildings were constructed with relatively low strength concrete of 18 MPa. And, columns were designed considering only vertical loads. In this study, compressive strength tests for low strength RC columns retrofitted by carbon fiber sheets were carried out. Carbon fiber sheet provides constructability and high tensile strength as well as good corrosion resistance characteristics. A pair of carbon sheets were wrapped with ${\pm}60^{\circ}$ angle with respect to longitudinal direction of RC column to increase structural capacity against axial and lateral load simultaneously. Strength and strain patterns and failure modes of specimens were analyzed and prediction equation of increased compressive strength of RC column confined by carbon fiber sheet was proposed based on regression analysis.

Interferometric coherence analysis using space-borne synthetic aperture radar with respect to spatial resolution (공간해상도에 따른 위성 영상레이더 위상간섭기법 긴밀도 분석)

  • Hong, Sang-Hoon;Wdowinski, Shimon
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.4
    • /
    • pp.389-397
    • /
    • 2013
  • Recently high spatial resolution space-borne Synthetic Aperture Radar (SAR) systems have launched and have been operated successfully. Interferometric SAR (InSAR) processing with the space-based high resolution observations acquired by these systems can provide more detail information for various geodetic applications. Coherence is regarded as a critical parameter in the evaluating the quality of an InSAR pair. In this study, we evaluate the coherence characteristics of high-resolution data acquired by TerraSAR-X (X-band) and ALOS PALSAR (L-band) and intermediate-resolution data acquired by Envisat ASAR (C-band) over western Texas, U.S.A. Our coherence analysis reveals that the high-resolution X-band TSX (3.1 cm) data has a high coherence level (0.3-0.6), similar to that of the L-band ALOS PALSAR data (23.5 cm) in short temporal baselines. Further more, the TSX coherence values are significantly higher than those of the C-band (5.6 cm) Envisat ASAR data. The higher coherence of the TSX dataset is a surprising result, because common scattering theories suggest that the longer wavelength SAR data maintain better coherence. In vegetated areas the shorter wavelength radar pulse interacts mostly with upper sections of the vegetation and, hence, does not provide good correlation over time in InSAR pairs. Thus, we suggest that the higher coherence values of the TSX data reflect the data's high-resolution, in which stable and coherent scatters are better maintained. Although, however, the TSX data show a very good coherence with short temporal baseline (11-33 days), the coherences are significantly degraded as the temporal baselines are increased. This result confirms previous studies showing that the coherence has a strong dependency on the temporal baseline.

Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

  • Pittayapat, Pisha;Jacobs, Reinhilde;Odri, Guillaume A.;Vasconcelos, Karla De Faria;Willems, Guy;Olszewski, Raphael
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.15-22
    • /
    • 2015
  • Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D Accuitomo$^{(R)}$ 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim$^{(R)}$ software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). Results: The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from $0.43{\pm}0.34mm$ to $0.51{\pm}0.46mm$. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

Size-Reduced Ring-Hybrid Coupler Using Phase-Inverting Ultra-Wideband Transitions and Its Frequency Doubler Application (초광대역 위상 역전 전이 구조를 이용한 소형화된 링 하이브리드 결합기 및 주파수 체배기 응용)

  • Song, Sun-Young;Kim, Young-Gon;Park, Jin-Hyun;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.1037-1044
    • /
    • 2010
  • In this paper, a new size-reduced, wideband ring-hybrid coupler is presented, and a design of a planar single-balanced doubler using the ring-hybrid is shown. This ring-hybrid coupler employs a pair of ultra-wideband transitions for phase inversion, which consists of in-phase and out of-phase transitions providing a good amplitude and phase balances for wide frequency ranges. The implemented ring-hybrid is 65 % smaller than conventional ring-hybrids, and provides 92.5 % and 81.3 % bandwidth at $\sum$ and $\Delta$ ports, respectively. Thanks to good amplitude and phase balances over wide bandwidth, the ring-hybrid can be applied to implement various balanced components. The implemented single-balanced doubler utilizing the ring-hybrid exhibits typical conversion loss of 10.5 dB for the output frequency range of 4~12 GHz with fundamental suppression level of 30 dB. The performance was also well-predicted with the nonlinear circuit simulation.

Injuries Associated with Inline Skating (인라인스케이트와 관련된 손상)

  • Song Ha Heon;Kim Joung Woo;Cho Yong Woo;Yang Jung Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.1
    • /
    • pp.25-30
    • /
    • 2004
  • Objective: Recently, inline skates are populary increasing and have become major recreational activities. This study was performed to determine the effective prevention means on various extremity injury by investigating injury severity occording to acute injury and overuse injury. Results: Acute inline skating injury was experienced mostly among the age between 6$\~$14 years old children after school around nearby their home without using no appropriate safety device gear. The wrist injury was mostly happened. We think that overuse injury is related to boot itself, boot fitting and improper skating techniques. Conclusion: So afterall, appropriate safety equipment wearing in inline skating at the safe place after learning about the skating skills can reduce the acute inline skating extremity injuries. Choosing a pair of good fitting boots, performing the exact pushing techniques and take good rests in the middle of skating frequently can reduce the overuse injury.

  • PDF