• Title/Summary/Keyword: glucose measurement

Search Result 267, Processing Time 0.026 seconds

Study of Enzyme Immobilization on Composite of CTA and PCL Membrane for Biosensor (바이오센서용 CTA와 PCL 혼합막에의 효소고정화 기법의 개발)

  • 홍성현;김태진
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.468-474
    • /
    • 1995
  • The disposable glucose bio-sensor using composite of CTA and PCL membrane was developed for measurement of glucose. The most effective membrane was composed of CTA/PCL(80/20, w/w) and glutaraldehyde one-step immobilization method ($10{\mu}m$ thickness) for glucose sensor gave the best result among various methods, considering oxygen permeability and electronic sensitivity. A scanning electron micrograph of the cross-section of a typical asymmetric CTA/PCL composite membrane showed that the membrane fused with a dense layer covered with a GOD-glutaraldehyde. Glucose oxidase immoblilized on the membrane showed the linearity between difference of absolute amperometric values and glucose concentrations within 7mM when the GOD immobilized electrode was used. About 35% of activity was remained after 8 days when the tyrosinase was immobilized on CTA/PCL (80/20) membrane.

  • PDF

Preparation and Stability Measurement of Liposome-amino Acid Conjugates (리포솜-아미노산 결합체의 제조와 안정성 측정)

  • 문제영;이기영;김진철
    • KSBB Journal
    • /
    • v.15 no.1
    • /
    • pp.96-99
    • /
    • 2000
  • Liposome-amino acid conjugates were prepared using phopholipid (dipalmitoylphosphatidylcholine (DPPC) or distearoylph-osphatidylcholine(DSPC)) and hydrophobically modified amino acids (glutamic acid(glu), glutamine(gln) or asparagine(asn)). The size of liposomes was about 100 nm. According to the glucose-induced turbidity changes, liposomes composed of DPPC and glutamic acid have higher glucose binding affinity than liposomes of DPPC-glutamine or DPPC-asparagine. Also, the liposomes were more stable in terms of aggregation or fusion than the others (DPPC-glutamine, DPPC-asparagine and DSPC-amino acids). As a rdsult, stable liposomes with an affinity for glucose could be prepared with DPPC and glutamic acid.

  • PDF

Measurement of Nutrition Counseling Effects for Diabetes Mellitus Patients (당뇨환자를 대상으로 한 영양상담의 효과측정)

  • 문수재
    • Journal of Nutrition and Health
    • /
    • v.27 no.10
    • /
    • pp.1070-1077
    • /
    • 1994
  • The purpose of this study was to measure the counseling effects for diabetes mellitus patients. To measure the effects of the nutrition counseling, 40(13 men and 27 women) outpatients with diabetes mellitus were selected and they were randomly assigned to either the counseling group or non counseling group. Twenty-one counseling group patients received nutrition counseling weekly for 6 weeks and 19 patients served as non counseling group(control group) did not received counseling over same study period. The results of this study can be summerized as follows : 1) The food attitude score of the counseling group significantly increased from 61.9$\pm$15.9 prior to counseling to 87.0$\pm$7.8 after counseling (p<0.001). 2) Fasting blood glucose level and postgrandial blood glucose level also showed significant difference between two groups(p<0.01). In the counseling group, the fasting blood glucose level significantly decreased from 163.5$\pm$48.6mg/dl to 142.3$\pm$40.6mg/dl(p<0.01), and the postgrandial blood glucose level significantly decreased from 281.3$\pm$105.1mg/dl(p<0.001). 3) There was a significant difference of glycosylated hemoglobin between the two groups(p<0.005), and the glycosylated hemoglobin level of counseling group significantly decreased from 11.2$\pm$2.9% to 9.7$\pm$3.6%(p<0.005). 4) There was a significant correlation between the food attitude score difference and the glycosylated hemoglobin level difference in counseling group(p<0.05).

  • PDF

Evaluation of the clinical accuracy of six portable blood glucose meters in dogs

  • Shin, Min-Keun;Kim, Hakhyun;Yun, Taesik;Kang, Ji-Houn;Kang, Byeong-Teck
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.3
    • /
    • pp.123-131
    • /
    • 2020
  • Portable blood glucose meters (PBGMs) are widely used because of their practicality. However, the accuracy of PBGMs has frequently been questioned. The objectives of this study were to evaluate factors that might interfere with measurements made using PBGMs, and to assess the clinical utility of 6 PBGMs. The glucose concentrations measured using the PBGMs were compared with those obtained using a reference method. The agreement between the measured values was assessed using Spearman correlation analysis, Passing-Bablok regression analysis, Bland-Altman plots, and consensus error grid analysis. Mann-Whitney and Kruskal-Wallis tests were performed to identify the parameters affecting glucose measurement. The results indicated that all of the PBGMs tested perform adequately for use in veterinary practice. In most cases, measurements made using PBGM corresponded well with the blood glucose values obtained using the reference method. Error grid analysis revealed that most of the PBGM values fell within zones A and B. However, some measurements of blood glucose concentrations < 80 mg/dL fell into zone C. PCV, and triglyceride and total protein concentration, significantly affected the output of some of the PBGMs. Therefore, clinicians should be aware of the characteristics of the PBGM that they use.

Electrochemical Determination of Glucose Concentration Contained in Salt Solution (소금용액에 포함된 글루코오스 농도의 전기화학적 측정)

  • 김영한
    • Journal of Korean Port Research
    • /
    • v.14 no.4
    • /
    • pp.475-479
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the determination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a quartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution, and a proper relation between the concentrations of glucose solution, and a proper relation between the concentration and the measurements is analyzed. As a result, it is found that a linear relation between the concentration of less than 900 ppm and the peak current when a constant potential of -180 mV (SSCE) is applied. The relation can be utilized for the determination of glucose concentration in sea water, and considering a direct relation between gluose concentration and chemical oxygen demand tells a possibility of the measurement of chemical oxygen demand using quartz crystal oscillators.

  • PDF

Determination of Glucose Using Enzyme Immobilized Membrane (효소 고정화 막을 이용한 Glucose의 정량)

  • Kim, Im Ok;Kwak, Kyeong Do;Ha, Youn Shick;Kwon, Hyo Shik;Seo, Moo Lyong
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.264-270
    • /
    • 1999
  • Enzyme electrodes for amperometric measurement of glucose were prepared by immobilization of glucose oxidase on an Immobilon-AV Affinity membrane and attachement to a Pt electrodes. The electrochemical oxidation of Hz02 was monitored at +0.8V vs. Ag/AgCl. Response was linear from 0.2 mM to 20mM. The detection limit was 10m3 mM. Response time, the optimum pH and life time of enzyme immobilized membrane was 12 seconds, pH 5.5(CH3COONaJCH3COOH) and about 27 days, respectively. When the enzyme electrode was applied for the determinaion of glucose with amperometric method, other physiolosical materials have not interfered. Also, we compared the result with that from AOAC(Association of Offical Analytical Chemists) method, measuring the glucose in sweet potato. The relative error was 0.1%.

  • PDF

Portable Amperometric Glucose Detection based on NiS/CuS Nanorods Integrated with a Smartphone Device

  • Heyu Zhao;Kaige Qu;Haoyong Yin;Ling Wang;Yifan Zheng;Shumin Zhao;Shengji Wu
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.252-261
    • /
    • 2023
  • Glucose detection is particularly important for clinical diagnosis and personal prevention and control. Herein, the smartphone-based amperometric glucose sensors were constructed using the NiS/CuS nanorods (NRs) as sensing electrodes. The NiS/CuS NRs were prepared through a facile hydrothermal process accompanied by the subsequent vulcanization treatment. The morphological and structural properties of NiS/CuS NRs were characterized with SEM, EDS, XRD, and XPS. Electrochemical measurements including cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy display that NiS/CuS NRs can act as highly efficient electrocatalyst for glucose detection. The NiS/CuS NRs electrodes present a wide detection range of 1-8000 µM for glucose sensing with the sensitivity of 956.38 µA·mM-1·cm-2. The detection limit was 0.35 µM (S/N=3). When employed in smartphone-based glucose sensing device, they also display a high sensitivity of 738.09 µA·mM-1·cm-2 and low detection limit of 1.67 µM. Moreover, the smartphone-based glucose sensing device also presents favorable feasibility in determination of glucose in serum samples with the recoveries ranging between 99.5 and 105.8%. The results may provide a promising viewpoint to design other new portable glucose sensors.

Non-invasive Blood Glucose Detection Sensor System Based on Near-Infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 검출 센서 시스템)

  • Kang, Young-Man;Han, Soon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.991-1000
    • /
    • 2021
  • Among non-invasive blood glucose detection technologies, the optical technique is a method that uses light reflection, absorption, and scattering characteristics when passing through a biological medium. It reduces pain or discomfort in measurement and has no risk of infection. So it is becoming a major flow of blood glucose detection research. Among them, near-infrared spectroscopy has a disadvantage in that the complexity increases when analyzing signals detected due to interferences between proteins and acids that share a similar absorption function with blood glucose molecules. In this study, a non-invasive sensor system with multiple near-infrared bands was designed and manufactured to alleviate the deterioration of blood glucose detection function that may occur due to skin absorption of near-infrared rays. A blood survey was conducted to verify the system, and the degree of blood glucose response in the blood was collected as spectral data, and the results of this study were quantitatively verified in terms of correlation between the data and blood glucose.

Effect of an Individually Tailored Program Based on Self-Measurement of Blood Glucose on Health Behavior and HbA1c in Diabetes and Pre-diabetes Patients (자가혈당측정 기반의 개별 맞춤형 프로그램이 당뇨병 및 당뇨병 전단계 환자의 건강행태와 당화혈색소에 미치는 영향)

  • Kim, Yoon-kyung;Kim, Bo-Ra;Yoo, Eun-Suk;Yun, Seo-Yeong;Jeong, Mi-Jeong;Choi, Ji-Hye;Choi, Jae-Soon;Sung, Hyun-Jin;Kang, Young-Suk;Lee, Min-Sook;Hwang, Tae-Yoon
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.2
    • /
    • pp.67-77
    • /
    • 2022
  • Objective: This study was to evaluate the effectiveness of an individually tailored program based on self-measurement of blood glucose on health behavior and HbA1c in diabetes and pre-diabetes patients. Methods: The program consisted of seven sessions for 12 weeks which were carried out every two weeks. Almost all sessions were progressed on untact method except for the first and last session. The 71 subjects were assessed for their knowledge of diabetes, health behavior, the experience of self-measurement of blood glucose, body mass Index (BMI) and hemoglobin A1c (HbA1c) at before and after the program. They were also evaluated on their degree of utilization of blood glucose measurements after the program. Results: Each mean score on their knowledge of diabetes, health behavior and the experience of self-measurement of blood glucose was significantly increased from 14.77, 25.50, and 2.70 to 15.41, 28.40, and 4.81, respectively. Each mean score on both BMI and HbA1c (n=53) was significantly decreased from 24.47kg/m2 and 7.27% to 24.01kg/m2 and 6.67%, respectively. The post-HbA1c had a significant negative correlation(r=-0.415) with the degree of utilization of blood glucose measurements. The degree of utilization of blood glucose measurements had a significant positive correlation(r=0.581) with post-health behavior. Conclusions: The program shows effectiveness in improving HbA1c in Type 2 diabetes and pre-diabetes patients. The post-HbA1c might be related to the degree of utilization of blood glucose measurements which might be related to the health behavior.