• 제목/요약/키워드: global performance analysis

검색결과 1,360건 처리시간 0.033초

원격의료서비스 수용요인의 구조적 관계 실증연구 (Structural Relationships Among Factors to Adoption of Telehealth Service)

  • 김성수;류시원
    • Asia pacific journal of information systems
    • /
    • 제21권3호
    • /
    • pp.71-96
    • /
    • 2011
  • Within the traditional medical delivery system, patients residing in medically vulnerable areas, those with body movement difficulties, and nursing facility residents have had limited access to good healthcare services. However, Information and Communication Technology (ICT) provides us with a convenient and useful means of overcoming distance and time constraints. ICT is integrated with biomedical science and technology in a way that offers a new high-quality medical service. As a result, rapid technological advancement is expected to play a pivotal role bringing about innovation in a wide range of medical service areas, such as medical management, testing, diagnosis, and treatment; offering new and improved healthcare services; and effecting dramatic changes in current medical services. The increase in aging population and chronic diseases has caused an increase in medical expenses. In response to the increasing demand for efficient healthcare services, a telehealth service based on ICT is being emphasized on a global level. Telehealth services have been implemented especially in pilot projects and system development and technological research. With the service about to be implemented in earnest, it is necessary to study its overall acceptance by consumers, which is expected to contribute to the development and activation of a variety of services. In this sense, the study aims at positively examining the structural relationship among the acceptance factors for telehealth services based on the Technology Acceptance Model (TAM). Data were collected by showing audiovisual material on telehealth services to online panels and requesting them to respond to a structured questionnaire sheet, which is known as the information acceleration method. Among the 1,165 adult respondents, 608 valid samples were finally chosen, while the remaining were excluded because of incomplete answers or allotted time overrun. In order to test the reliability and validity of the assessment scale items, we carried out reliability and factor analyses, and in order to explore the causal relation among potential variables, we conducted a structural equation modeling analysis using AMOS 7.0 and SPSS 17.0. The research outcomes are as follows. First, service quality, innovativeness of medical technology, and social influence were shown to affect perceived ease of use and perceived usefulness of the telehealth service, which was statistically significant, and the two factors had a positive impact on willingness to accept the telehealth service. In addition, social influence had a direct, significant effect on intention to use, which is paralleled by the TAM used in previous research on technology acceptance. This shows that the research model proposed in the study effectively explains the acceptance of the telehealth service. Second, the research model reveals that information privacy concerns had a insignificant impact on perceived ease of use of the telehealth service. From this, it can be gathered that the concerns over information protection and security are reduced further due to advancements in information technology compared to the initial period in the information technology industry, and thus the improvement in quality of medical services appeared to ensure that information privacy concerns did not act as a prohibiting factor in the acceptance of the telehealth service. Thus, if other factors have an enormous impact on ease of use and usefulness, concerns over these results in the initial period of technology acceptance may become irrelevant. However, it is clear that users' information privacy concerns, as other studies have revealed, is a major factor affecting technology acceptance. Thus, caution must be exercised while interpreting the result, and further study is required on the issue. Numerous information technologies with outstanding performance and innovativeness often attract few consumers. A revised bill for those urgently in need of telehealth services is about to be approved in the national assembly. As telemedicine is implemented between doctors and patients, a wide range of systems that will improve the quality of healthcare services will be designed. In this sense, the study on the consumer acceptance of telehealth services is meaningful and offers strong academic evidence. Based on the implications, it can be expected to contribute to the activation of telehealth services. Further study is needed to assess the acceptance factors for telehealth services, such as motivation to remain healthy, health care involvement, knowledge on health, and control of health-related behavior, in order to develop unique services according to the categorization of customers based on health factors. In addition, further study may focus on various theoretical cognitive behavior models other than the TAM, such as the health belief model.

모바일게임 기업의 정성적 평가요인에 관한 연구 (A Study on the Qualitative Evaluation Factors for Mobile Game Company)

  • 최석균;황보윤;이도연
    • 벤처창업연구
    • /
    • 제8권3호
    • /
    • pp.125-146
    • /
    • 2013
  • 최근 모바일 게임이 국내 코스닥 게임 기업들의 기업가치 순위를 좌우하기 시작하면서, 그동안 온라인게임 투자에 주력해왔던 벤처캐피털 등 투자 회사들이 모바일게임 및 모바일게임 기업 투자에 큰 관심을 보이고 있다. 아울러 2012년부터 본격화되기 시작한 엔젤투자자들과 엑셀러레이터들 중에서도 모바일게임 기업 투자가 증가하고 있다. 이러한 모바일 게임투자자들에게 가장 중요한 이슈는 모바일게임 기업 혹은 게임콘텐츠를 어떠한 방법으로 평가할 것인가 하는 것이다. 따라서 본 연구는 모바일게임 기업의 평가에 대한 평가기준과 평가항목을 도출하였다. 연구방법은 게임 수요자 및 공급자의 의견을 수렴하기 위하여 게임업계의 공급을 담당하는 개발사 및 경영자 그룹, 수요를 대변하는 게임전문가 및 투자사 그룹을 포함하는 전문가 20인을 선정하여 델파이 기법(Delphi Technique)에 따라 설문조사를 실시함으로써 모바일게임 기업을 평가할 수 있는 경영능력, 개발력, 게임성, 사업성, 운영능력 등의 5개 평가기준과 경영자의 신뢰도 등 20개의 세부 평가요소를 도출하였다. 또한 델파이 설문을 통하여 도출된 정성적인 요소의 중요도를 분석하기 위하여 AHP(Analytic Hierarchy Process) 이론에 근거하여 모바일게임 기업의 평가를 위한 평가요소의 계층분석도를 작성하였으며, 각 요소에 대한 쌍대비교(Pair-wise Comparison)를 통하여 그 중요도를 분석한 결과, 게임의 핵심적 재미(12.2%), 게임의 몰입도(10.3%), 보안 신뢰성(8.9%), 핵심개발자의 개발능력(7.6%) 등의 순으로 나타났다. 본 연구의 의의는 모바일게임 기업의 M&A나 혹은 프로젝트 투자를 진행함에 있어 모바일게임 기업을 평가하는 현실적 평가요소가 무엇이고 어떤 중요도에 의하여 평가할 것인가에 대한 보다 객관적인 방법론을 제시했다는 점이다.

  • PDF

정밀한 다중센서 영상정합을 위한 통계적 상관성의 증대기법 (Enhancement of Inter-Image Statistical Correlation for Accurate Multi-Sensor Image Registration)

  • 김경수;이진학;나종범
    • 대한전자공학회논문지SP
    • /
    • 제42권4호
    • /
    • pp.1-12
    • /
    • 2005
  • 영상정합은 동일한 장면에 대해서 서로 다른 시간 혹은 서로 다른 특성의 센서로부터 서로 다른 위치에서 얻은 영상들의 위치적 대응관계를 찾는 기법이다. 이 논문에서는 특성이 다른 적외선 센서와 광학 센서로부터 얻은 영상의 정합을 위한 새로운 알고리즘을 제안한다. 지금까지 제안된 서로 다른 특성의 영상을 위한 정합기법은 크게 특징점 기반 영상정합기법과 밝기값 기반 영상정합기법으로 구분될 수 있다. 특징점 기반의 영상정합기법은 정확하게 대응하는 특징점을 선택하는 것이 성능에 결정적인 영향을 준다 그러나 적외선 영상과 가시광선 영상에서는 특징점이 서로 같지 않은 경우가 많기 때문에 강인하지 못하다 그리고 밝기 값 기반의 정합기법에서는 정규상호정보를 유사성 척도로 사용한 영상정합기법이 가장 좋은 성능을 제공하는 것으로 알려져 있다. 그러나 정규상호정보 기반의 영상정합기법은 두 영상의 통계적 상관성이 전역적이어야 한다는 가정을 전제하는데, 적외선 영상과 가시광선 영상에서는 이를 보장하지 못하는 경우가 많아 정규상호정보를 유사성 척도로 사용하는 영상정합기법에서도 좋은 성능을 기대하기 힐들다. 따라서 이 논문에서는 적외선 영상과 가시광선 영상의 통계적 상관성의 해석에 기반한 두 단계 영상정합기법을 제안한다. 정확하고 강인한 정합을 위해서 첫 단계에서는 두 영상에서 통계적 상관성이 높은 부분을 추출하는 ESCR기법과 두 영상을 통계적 상관성이 높도록 필터링하는 ESCF기법을 수행한다. 그리고 두 번째 단계에서는 첫 단계에서의 결과 영상에 대해서 정규상호정보를 유사성 척도로 한 영상정합을 수행한다. 다양한 적외선 영상과 가시광선 영상을 이용한 실험으로부터 제안하는 두 단계 영상정합기법이 기존의 정규상호정보 기반의 영상정합기법에 비해 정확도와 강인함, 그리고 실행 속도의 측면에서 더욱 향상된 성능을 제공함을 확인하였다.

기업체에서의 역량모델 개발과 활용실태 분석 (The Analysis on the Actual Condition of Development of Competency Model and Application in Corporation)

  • 주인중;김덕기;정종태;김호현;최선아
    • 직업교육연구
    • /
    • 제29권3호
    • /
    • pp.309-334
    • /
    • 2010
  • 글로벌 경제 전쟁 하에서 각 기업의 경쟁력은 효율적 인재개발에 의한 고성과 창출에 있다. 이에 최근 규모가 있는 선진화된 기업을 중심으로 기업의 비전과 전략에 기반한 구성원의 역량과 성과를 분석하고 역량모델을 개발하여 기업 내 인적자원 개발과 관리에 적극 도입하고 있는 추세다. 따라서 본 연구는 조직 구성원 역량진단을 위해 국내 기업에 도입되고 있는 역량모델에 대한 활용 정도를 살펴보기 위해 기업체에서의 역량모델의 개발 및 활용 실태 파악을 목적으로 설정하였다. 이를 위해 관련 전문가협의회, 자문위원회를 통해 설문 항목을 구성하여, 국내 기업들을 대상으로 설문조사를 실시하였다. 조사결과, 첫째 대부분의 기업들이 규모나 업종에 관계없이 주로 외부 모델을 벤치마킹하여 자체개발하거나, 외부컨설팅사의 부분적인 주도하에 개발된 역량모델을 사용하고 있어 기업특성에 맞는 역량모델 개발의 중요성이 시급하였다. 둘째는 역량모델 도입계기의 주요 이유가 근로자 역량강화에 있음에도 불구하고 개발된 역량모델을 인적자원관리 전 분야에 활용하지 못하고 있는 실정이므로, 역량모델 활용에 대한 한계를 극복할 수 있는 방안 마련이 필요하였다. 셋째는 기업의 역량모델 사후관리의 체계화에 대한 중요성이다. 이는 기업의 규모와 업종에 관계없이 다수의 기업이 업무환경 변화로 인하여 역량모델을 업그레이드 하거나, 또는 개발된 역량 모델을 아예 업그레이드 하지 않는 것으로 나타난 결과에서 찾아볼 수 있었다. 이 연구는 기업 현장에서 역량모델이 개발되고 활용되는 실태에 대한 초기연구인 만큼, 역량모델을 활용하고 있는 국내 기업의 내부 상황이나 조직 구성원의 특정 직급에 따른 심층 연구의 초석이 될 것이다.

망상대구점(网上代购店): 소비자감지풍험화산품평개대원산국형상적영향(消费者感知风险和产品评价对原产国形象的影响) (Surrogate Internet Shopping Malls: The Effects of Consumers' Perceived Risk and Product Evaluations on Country-of-Buying-Origin Image)

  • Lee, Hyun-Joung;Shin, So-Hyoun;Kim, Sang-Uk
    • 마케팅과학연구
    • /
    • 제20권2호
    • /
    • pp.208-218
    • /
    • 2010
  • 互联网快速增长, 已经成为一个重要的零售渠道, 并出现了各种互联网零售商, 又称电子零售商. 一种网上代购店蓬勃发展起来, 吸引了国内市场的消费者. 这是一种独特的电子零售商, 他们从全球购买国内市场尚未进口的名牌产品, 寄给个人购买者, 并收取服务费. 有些消费者喜欢高端独特但无进口资格的品牌, 却因付款问题或国内的寄送问题很难直接从海外零售商处购买. 在韩国, 网上代购店的数量和销售量快速增长-2008年韩国有超过430个活跃商店和5000亿销售额, 需要这种代购服务的消费者数量也在急剧增加. 这种电子零售的概念源于 "代理中介采购" -种存在已久的形式和内容多样化的代购. 通常市场经营者面对的是购买者的代表人而非本人, 由消费者决定的代理购买者影响越来越大. 很多市场营销和心理学领域的学者都研究过代理对消费者购买决定的影响范围. 然而, 在互联网商务方面却没有深入的研究. 此外, 网上代购店作为代理购买者, 将海外品牌或零售商同国内消费者连接起来. 它有一个特点, 代理购买国, 即代购商品所在国的形象对消费者的态度和购买倾向有重要影响, 还会影响消费者在进行信息处理时所感知的风险维度. 然而, 尽管对原产国不同维度的影响已有很多研究, 对网络内容的相关研究却很少. 已有研究证明, 原产国信息作为产品制造情况的线索对消费者的评价有正面影响, 但对这种形式下网络代理购买国的形象和产品评价之间的关系进行的研究却很少. 因此, 作者们发这种具体的零售渠道很值得研究, 重点结构间的系统关系以及各自不同的路径很值得探索. 已有研究证明代购原产国, 也就是代购店购买商品所在地的形象, 不仅对消费者的产品评价(包括态度和购买意向)有正面影响, 还对感知风险的三个维度有负面影响: 产品相关, 行员相关, 以及购买后的风险. 在所有的感知风险中, 由于对产品性能的高度不确定性, 产品相关的风险受负面形象的影响最大(${\beta}$= -.30), 其次是航运相关风险(${\beta}$= -.18)和购买后的风险(${\beta}$= -.15). 对产品态度(${\beta}$= .10)和购买倾向(${\beta}$= .14)也有一定影响. 此外, 经证明, 感知风险的三个维度通过对产品的态度作为中介, 对购买倾向有负面的的影响(${\beta}$= -.57: 产品相关风险${\rightarrow}$ 对产品的态度; ${\beta}$= -.24: 航运相关风险${\rightarrow}$ 对产品的态度; ${\beta}$= -.44: 购买后风险${\rightarrow}$ 对产品的态度). 从更多的分析可以看出, 消费者处理信息的路径会因其对产品知识的等级不同而改变. 新手购买者知识等级较低, 只会考虑感知风险, 而知识等级较高的专家购买者则会考虑到代理购买国的形象和感知风险两个方面, 对产品形成更准确更系统的态度和决定. 这同之前的研究相一致. 本研究提出一些理论和实际的建议. 代理购买国的形象会影响消费者的风险感知和行为结果, 因此应谨慎选择代购国家, 如果这种新型的零售业务快速发展起来, 应控制好消费者的风险, 无论是新手或专家. 另外, 由于消费者各自知识等级不同, 处理信息的路径也不尽相同, 针对不同消费者应形成成熟的市场营销手段. 新手购买者需要风险消减方面的建议, 以帮助他们形成更好的态度, 而专家购买者应选择更好更发达的国家进行代购. 消费者可以使用担保策略来促使在线购物的顺利进行. 本研究没有拘于概括性等限制. 在今后的研究中, 应进一步测试比较有相关结构的不同电子零售商.

첨단산업의 환경동태성이 공급체인의 결속에 미치는 영향: 유연성과 의존성의 역할 (The Effects of Environmental Dynamism on Supply Chain Commitment in the High-tech Industry: The Roles of Flexibility and Dependence)

  • 김상덕;지성구
    • 마케팅과학연구
    • /
    • 제17권2호
    • /
    • pp.31-54
    • /
    • 2007
  • 첨단산업의 기업들은 환경의 변화에 효과적으로 대응하는 것을 기업 성패에 중요한 요인으로 여기고 있다. 하지만 첨단산업의 환경 동태성이 공급체인 구성원 간 관계 결속에 미치는 영향에 관한 연구가 부족하여, 환경 변화에 효과적인 대응을 어렵게 하고 있다. 본 연구는 첨단산업에서 환경 동태성이 공급체인의 결속에 영향을 미치는 메커니즘에 대해 규명하고 있다. 좀 더 구체적으로 말하면, 첫째, 첨단산업의 고객, 경쟁, 기술 동태성이 공급체인의 결속에 어떠한 영향을 미치는지, 둘째, 공급체인의 유연성과 의존성이 이러한 영향에 어떠한 조절효과를 가지는 지 실증하고 있다. 구조방정식 모형에 의한 가설검정 결과 첨단산업의 고객 동태성은 공급체인의 결속을 약화시켰지만 경쟁 동태성은 강화시키는 역할을 하였다. 한편 유연성과 의존성은 고객과 경쟁 동태성에 유의적인 조절 효과를 가졌다.

  • PDF

가정과 교사의 창의.인성 교육에 대한 관심과 실행에 대한 인식 - CBAM 모형에 기초하여- (Home Economics teachers' concern on creativity and personality education in Home Economics classes: Based on the concerns based adoption model(CBAM))

  • 이인숙;박미정;채정현
    • 한국가정과교육학회지
    • /
    • 제24권2호
    • /
    • pp.117-134
    • /
    • 2012
  • 본 연구의 목적은 가정과교육에서 창의 인성 교육에 대한 가정과 교사의 관심 단계와 실행 수준, 그리고 실행 실태를 알아보는데 있다. 연구 자료는 전국의 중학교 가정과 교사를 대상으로 체계적 표집과 편의 표집을 하여 우편과 이메일을 통해 설문지를 배포하고 회수된 187부를 최종 분석에 사용하였다. 조사 도구는 주로 Hall(1987)이 개발한 혁신에 대한 교사의 관심도와 실행 수준에 대한 질문지를 수정 보완하여 사용하였고 그 외는 선행연구를 기초하여 개발하였으며 타당도와 신뢰도를 검증하였다. 자료는 SPSS/window(12.0) 프로그램을 이용하여 빈도, 백분율, 평균, 표준편차, t-test, ANOVA를 실시하였다. 본 연구를 통해 밝혀진 결과를 요약하면 다음과 같다. 첫째, 창의 인성 교육에 대한 가정과 교사의 관심 단계는 정보적 관심 단계(85.51)가 가장 높았으며 다음으로 개인적 관심 단계(85.18), 운영적 관심 단계(81.88), 지각적 관심 단계(82.15), 강화적 관심 단계(68.80), 협동적 관심 단계(61.97), 그리고 결과적 관심단계(59.76)의 순으로 나타났다. 둘째, 창의 인성 교육에 대한 가정과 교사의 실행 수준은 기계적 실행 수준(수준 3; 21.4%)이 가장 많았으며, 다음으로 탐색 수준(수준 1; 20.9%), 정교화 수준(수준 5; 17.1%), 사용하지 않는 수준(수준 0; 15.0%), 준비 수준(수준 2; 10.2%), 통합 수준(수준 6; 5.9%), 갱신 수준(수준 7; 4.8%), 일상화 수준(수준 4; 4.8%) 순이었다. 셋째, 창의 인성 교육에 대한 가정과 교사의 실행 실태를 조사한 결과, 반 이상의 가정과 교사(56.1%)는 가정과 수업에서 인성 교육에 치중하고 있으며, 31.0%의 교사는 창의 인성 교육을 모두 실행한다고 응답하였다. 반면 소수의 교사(6.4%)는 창의성 교육을 실행한다고 응답하였고 같은 수의 교사(6.4%)는 창의성과 인성 교육 어느 것도 실행하지 않는다고 응답하였다. 가정과 교사의 창의 인성 교육 요소의 실행 정도를 조사한 결과, 창의 인성 교육 요소의 실행은 평균은 5점 만점에서 3.76이었고 창의성 요소의 평균은 3.59, 인성 요소의 평균은 3.94로 보통보다 높았다. 창의성 교육 요소의 실행 정도에 대해서, 개방성/민감성(3.97)을 가장 많이 실행하였고 다음으로 문제해결능력(3.79), 호기심/흥미(3.73), 비판적 사고(3.68), 논리/분석적 사고(3.63), 문제발견능력(3.61), 독창성(3.57), 유추성(3.47), 유창성/융통성(3.46), 정교성(3.46), 상상력(3.37), 몰입/공감(3.37)의 순으로 실행하였다. 인성 교육 요소는 실천력(4.07)을 가장 많이 실행하였고, 다음으로 협동/배려/공정(4.06), 자기관리능력(4.04), 시민의식(4.04), 진로개발능력(4.03), 환경친화능력(3.95), 책임(감)/소유(3.94), 의사결정능력(3.89), 신뢰/정직/약속(3.88), 자율성(3.86), 글로벌역량(3.55)의 순으로 실행한 것으로 나타났다. 창의 인성 교육을 실행할 때 어려운 점으로, 많은 가정과 교사(64.71%)는 창의 인성 교육을 실행할 수업 자료가 부족한 데 있다고 하였으며, 40.11%의 교사는 창의 인성 교육의 연수 기회가 적은데 있다고 응답하였다. 한편 38.50%의 가정과 교사는 창의 인성 교육에 대한 평가 기준을 설정하거나 평가 도구를 개발하는 것이 어렵다고 응답하였고, 25.67%의 교사는 창의 인성 교육 방법을 모른다고 응답하였다. 창의 인성 교육 실행을 위해서 필요한 지원에 대해서, '창의 인성 교육과 관련된 학생들의 체험활동의 확대'(4.34), '창의성과 인성을 중시하는 가정과 수업 문화 조성'(4.29), '학생 발달 단계에 적합한 창의 인성 교육 내용'(4.27), '창의 인성 교육을 담당할 교수 인력 확보'(4.21), '창의 인성 교육의 개념과 가치 확립'(4.09), '지역 사회 기업 등과 연계한 창의 인성 교육 추진'(3.94)의 순으로 응답하였다.

  • PDF

대영향(对影响)HSDPA복무적태도화사용의도적인소적연구(服务的态度和使用意图的因素的研究): 재아주화구주지간적(在亚洲和欧洲之间的)-개과문화비교(个跨文化比较) (The Factors Affecting Attitudes Toward HSDPA Service and Intention to Use: A Cross-Cultural Comparison between Asia and Europe)

  • Jung, Hae-Sung;Shin, Jong-Kuk;Park, Min-Sook;Jung, Hong-Seob;Hooley, Graham;Lee, Nick;Kwak, Hyok-Jin;Kim, Sung-Hyun
    • 마케팅과학연구
    • /
    • 제19권4호
    • /
    • pp.11-23
    • /
    • 2009
  • HSDPA(高速下行分组接入)是在第三代的W-CDMA技术基础上的3.5代移动通信异步服务. 在韩国, 它主要是通过提供可视电话服务. 由于更强大和多元化的服务扩散, 随着移动通信技术迅速的进步, 消费者需要更多的选择. 然而, 由于各种技术, 不论消费者偏好往往会溢出市场, 消费者感到越来越迷惑. 因此, 我们不应该采取只注重发展假设是下一代新技术项目的战略相反, 我们应该了解消费者接受新的形式和技术的过程, 通过制定战略, 使开发人员能够理解并提供消费者真正想要的, 从而降低进入市场的障碍. 在技术接受模型(TAM)中, 感知到的有用性和使用的简单性被认为是影响人们接受新技术的态度的最重要因素(Davis, 1989; Taylor and Todd, 1995; Venkatesh, 2000; Lee et al., 2004). 感知到的有用性是一个人相信某种特定的技术能提高他或她工作绩效的程度. 感知易用性是主观认为使用某种特定技术不需要太多体力和精力的付出的程度(Davis, 1989; Morris and Dillon, 1997; Venkatesh, 2000). 感知的愉悦性和感知的有用性已经被清楚的证明对接受技术的态度有影响(Davis et al., 1992). 比如, 网上购物的愉悦性已经表现出对消费者对网上商家的态度有积极的影响(Eighmey and McCord, 1998; Mathwick, 2002; Jarvenpaa and Todd, 1997). 消费者的感知风险是一种主观风险. 这种风险和客观可能的风险是有显著区别的. 感知风险包括心理上的风险, 这是当消费者为某一特定物品而选择品牌, 商店和购买方式时所感知到的. 企业革新产品的能力取决于有效的获得有关新产品的知识(Bierly and Chakrabarti, 1996; Rothwell and Dodgson, 1991). 知识获取是公司感知外界新事物和技术的价值的能力(Cohen and Levinthal, 1990); 是公司评估外界最新的技术的能力(Arora and Gambaradella, 1994); 是公司正确预测这项科技对未来革新的能力(Cohen and Levinthal, 1990). 消费者创新是一种在社会体系中比其他人更早接受创新的程度(Lee, Ahn, and Ha, 2001; Gatignon and Robertson, 1985). 也就是说, 它显示了消费者如何快速、方便地接受新的思路. 创新被认为是重要的, 因为它对消费者是否接受新产品和他们多快接受新产品有显著的影响(Midgley and Dowling, 1978; Foxall, 1988; Hirschman, 1980). 我们用技术接受模型来进行跨国家的研究比较, 此模型实证验证了影响态度的因素-感知有用性, 易用性, 感知愉悦, 感知风险, 创新和感知的知识管理水平-和对HSDPA服务的态度之间的关系. 我们为HSDPA服务提供商开发更有效的管理方法还验证了态度和使用意图之间的关系. 在本研究中, 我们在韩国350名学生中分发了346份问卷调查. 由于其中26份收回的问卷时不完整的或者有缺失数据, 所以在假设检验时320份问卷被使用. 在英国, 200份问卷收回了192份, 舍弃了两份不完整的之后, 总共有190份问卷用于统计分析中. 整体模型的分析结果如下: 韩国, x2=333.27(p=0.0), NFI=0.88, NNFI=0.88, CFI=0.91, IFI=0.91, RMR=0.054, GFI=0.90, AGFI=0.84; 英国, x2=176.57(p=0.0), NFI=0.88, NNFI=0.90, CFI=0.93, IFI=0.93, RMR=0.062, GFI=0.90, AGFI=0.84. 在韩国消费者中, 从有关影响HSDPA服务的使用意图和态度之间的关系的假设检验的结果中, 感知的有用性, 易用性, 乐趣, 知识管理的高水平和促进创新对HSDPA移动手机的态度有积极的影响. 然后, 易用性和感知的乐趣对HSDPA服务的使用意图没有直接的影响. 这可能是因为在日常生活中使用视频电话还不是必需的这一现实. 而且消费者对HSDPA视频电话的态度和使用意图有直接的关系, 这些态度包括感知的有用性, 易用性, 乐趣, 知识管理的高水平和创新. 这些关系构成了购买意图的基础, 并造成消费者决定谨慎购买的情况. 对欧洲消费者的假设检验结果揭示了感知的有用性, 乐趣, 风险和知识管理水平是影响态度形成的因素, 而易用性和创新则对态度没有影响. 特别是效果价值和感知有用性, 在快乐和知识管理之后对态度有最大的影响. 相反, 认为感知风险对态度影响较小. 在亚洲模型中易用性和感知的乐趣没有发现对使用意图有直接影响. 然而, 因为态度广泛的影响使用意图, 感知有用性, 乐趣, 风险和知识管理可被视为从使用意图中的态度发展的关键因素. 总之, 感知的有用性, 愉悦和知识管理水平在亚洲和欧洲消费者中对态度形成都有影响, 这些梯度形成了消费者的使用意图. 而且, 易用性和感知的乐趣对使用意图的假设被拒绝. 然而, 易用性, 感知风险和创新有不同的结果. 在亚洲消费者中, 感知风险对态度形成没有影响, 而在欧洲消费者中, 易用性和创新对态度都没有影响.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF