• 제목/요약/키워드: glass pipe

검색결과 104건 처리시간 0.021초

유리섬유 강화플라스틱 복합관의 구조적 특성 (Structural Behavior of Glass-Fiber Reinforced Plastic Composite Pipes)

  • 연규석;김남길;조규우;김동준;최종윤;백종만
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.822-827
    • /
    • 2003
  • This study was performed to evaluate the internal and external factors affecting external strength of the 3-layer polymer composite pipes made of polymer mortar and fiber-glass reinforced plastic. Twenty four sandwich type 3-layer polymer composite pipes were made of polymer mortar and fiber-glass reinforced plastic by centrifugal method. The objective of this study was to evaluate the effects the of polymer mortar thickness for and core fiber-glass contents per unit area on external strength of 3-layer polymer composite pipes. For the more economical and practical design of 3-layer polymer composite pipe, further study should be done for the various polymer mortar, fiber-glass and different ratio of the inside/outside FRP thickness.

  • PDF

Numerical Study on the Air-Cushion Unit for Transportation of Large-Sized Glass Plate

  • Jun, Hyun-Joo;Kim, Kwang-Sun;Im, Ik-Tae
    • 반도체디스플레이기술학회지
    • /
    • 제6권1호
    • /
    • pp.59-64
    • /
    • 2007
  • Non-contact transportation of a large-sized glass plate using air cushion for the vertical sputtering system of liquid crystal display (LCD) panel was considered. The objective of the study was to design an air pad unit which was composed of multiple injection and exhaust holes and mass flow supplying pipe. The gas was injected through multiple small holes to maintain the force for levitating glass plate. After hitting the plate, the air was vented through exhaust holes. Complex flow field and resulting pressure distribution on the glass surface were numerically studied to design the air injection pad. The exhaust hole size was varied to obtain evenly distributed pressure distribution at fixed diameter of the injection hole. Considering the force for levitating glass plate, the diameter of the exhaust hole of 30 to 40 times of the gas injection hole was recommended.

  • PDF

대구경 상수도관 부식 손상부의 고분자 필러와 복합슬리브 성능 평가 (Performance assessment of polymeric filler and composite sleeve technique for corrosion damage on large-diameter water pipes)

  • 이호민;박정수;박정주;배철호
    • 상하수도학회지
    • /
    • 제37권4호
    • /
    • pp.203-214
    • /
    • 2023
  • In this study, the physical properties and fracture characteristics according to the tensile load are evaluated on the materials of the polymeric filler and carbon fiber-based composite sleeve technique. The polymeric filler and the composite sleeve technique are applied to areas where the pipe body thickness is reduced due to corrosion in large-diameter water pipes. First, the tensile strength of the polymeric filler was 161.48~240.43 kgf/cm2, and the tensile strength of the polyurea polymeric filler was relatively higher than that of the epoxy. However, the tensile strength of the polymeric filler is relatively very low compared to ductile cast iron pipes(4,300 kgf/cm2<) or steel pipes(4,100 kgf/cm2). Second, the tensile strength of glass fiber, which is mainly used in composite sleeves, is 3,887.0 kgf/cm2, and that of carbon fiber is up to 5,922.5 kgf/cm2. The tensile strengths of glass and carbon fiber are higher than ductile cast iron pipe or steel pipe. Third, when reinforcing the hemispherical simulated corrosion shape of the ductile cast iron pipe and the steel pipe with a polymeric filler, there was an effect of increasing the ultimate tensile load by 1.04 to 1.06 times, but the ultimate load was 37.7 to 53.7% compared to the ductile cast iron or steel specimen without corrosion damage. It was found that the effect on the reinforcement of the corrosion damaged part was insignificant. Fourth, the composite sleeve using carbon fiber showed an ultimate load of 1.10(0.61T, 1,821.0 kgf) and 1.02(0.60T, 2,290.7 kgf) times higher than the ductile cast iron pipe(1,657.83 kgf) and steel pipe(2,236.8 kgf), respectively. When using a composite sleeve such as fiber, the corrosion damage part of large-diameter water pipes can be reinforced with same level as the original pipe, and the supply stability can be secured through accident prevention.

원전 냉각수 취수용 지중매설 GFRP관의 구조적 거동 조사 (An Investigation of Structural Behavior of Underground Buried GFRP Pipe in Cooling Water Intake for the Nuclear Power Plant)

  • 이형규;박준석
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.91-96
    • /
    • 2015
  • GRP pipe (Glass-fiber Reinforced Plastic Pipe) lines making use of FRP (Fiber Reinforced Plastic) are generally thinner, lighter, and stronger than the existing concrete or steel pipe lines, and it is excellent in stiffness/strength per unit weight. In this study, we present the result of field test for buried GRP pipes with large diameter(2,400mm). The vertical and horizontal ring deflections are measured for 387 days. The short-term deflection measured by the field test is compared with the result predicted by the Iowa formula. In addition, the long-term ring deflection is predicted by using the procedure suggested in ASTM D 5365(ANNEX) in the range of 40 to 60 years of service life of the pipe based on the experimental results. From the study, it was found that the long-term vertical and horizontal ring deflection up to 60 years is less than the 5% ring deflection limitation.

실측을 통한 융착식 플라스틱 입상배관 성능 평가 (An Applicability Estimation of Plastic Vertical Pipes using Electric Fusion Fittings through Measurement)

  • 박률;안영철;김현대;김정수;곽유식;김용경
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.595-599
    • /
    • 2013
  • The pipes used in buildings are generally categorized into metallic or plastic materials. Metal pipes, such as copper and stainless steel pipes, are mainly used for water and hot water supply, and for the heating system. However, plastic pipes made of polyethylene and cross-linked polyethylene are used for floor heating, water drainage, and air vent systems. Usually, plastic pipes have thermal demerits, such as high linear expansion coefficients and bending phenomenon by hot water, although the pipes have several merits of light weight, low price, low thermal conductivity, and the comparatively high workability of metal pipes. Therefore, if those kind of demerits are overcome, plastic pipes can be easily accepted for hot water systems. This research is aimed to evaluate the applicability for vertical heating pipes of a plastic pipe system consisting of electric fusion fitting of a conductive carbon compound and propylene random glass fiber pipe, through measurement of the expansion rate and leakage in summer and winter seasons, in the apartment construction field.

지중매설 유리섬유복합관의 관변형에 관한 안전성 평가 (A Safety Evaluation on the Ring Deflection of Buried GRP Pipes)

  • 박준석;김선희;김응호;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제2권2호
    • /
    • pp.26-33
    • /
    • 2011
  • 최근 지중매설 유리섬유복합관(GRP관)은 유해한 환경에서 뛰어난 성능을 보유하고 있어 하수관거용으로서 사용이 증가 되고 있다. 또한 지중에 매설되어 있는 조건에서 기존의 콘크리트관 등 강성관에 비해 구조적 성능이 뛰어나다. 지중매설 GRP관은 주로 상부에 작용하는 상부토압과 활하중에 의한 압축응력에 의해 원주방향으로 변형이 일어나게 된다. GRP관의 구조적 거동은 매설토와 주변의 지반의 성질에 따라 다르게 설계되어야 한다. GRP관의 설계는 Spangler 의 변형량 계산식을 Watkins에 의해 수정되어 사용되고 있다. 이 연구에서는 Watkins의 관변형 추정식에 GRP관의 재료적 특성을 고려하여 관변형량을 예측하였다.

자기손상자현 기능성 콘크리트 개발 (Development of Self-Diagnosis Function Concrete for Damage)

  • 장주영;김이성;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.198-201
    • /
    • 2003
  • The R.C Building will be superannuated as time passes. This program is generated by propagation of cracks. In order to manage such cracks, time and efforts, expense, etc. are required. In this study, glass sensors were embedding in a model beam and column and leakage of fluorescence and adhesive material was investigated. Further, currents in glass pipe were observed to find the leakage of liquid in glass pipes. Progressive cracks generated by cause the fracture of glass pipes. Therefore, the liquid become to flow and electric current stops, and the cracked part of the member can be found easily. Moreover, the adhesive delays progressive cracking system that responds in air, and the life of a structure can be made to extend. The purpose of this research is to develop of low price sensors that can perform of self-diagnosis in addition to ability of concrete repair concrete to damage.

  • PDF

지중매설 GRP 관의 관변형 예측 (Prediction of Ring Deflection GRP Pipe Buried Underground)

  • 김선희;이영근;주형중;정남진;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제4권3호
    • /
    • pp.38-44
    • /
    • 2013
  • Glass fiber reinforced plastic (GRP) pipes buried underground are attractive for use in harsh environments, such as for the collection and transmission of liquids which are abrasive and/or corrosive. In this paper, we present the result of investigation pertaining to the structural behavior of GRP flexible pipes buried underground. In the investigation of structural behavior such as a ring deflection, experimental and analytical studies are conducted. In addition, vertical ring deflection is measured by the field test and finite element analysis (FEA) is also conducted to simulate behavior of GRP pipe buried underground. Based on the results from the finite element analyses considering soil-pipe interaction the vertical ring deflection behavior of buried GRP pipe is predicted. In addition, analytical and experimental results are compared and discussed.

MMA 이중 플랜지를 갖는 GFRP 복합관 구조거동에 관한 실험 연구 (II) (An experimental study on structural behaviour of the MMA double wide flanged GFRP pipe composite structures (II))

  • 지효선
    • 복합신소재구조학회 논문집
    • /
    • 제6권3호
    • /
    • pp.50-61
    • /
    • 2015
  • This paper presents on the structural behavior of the the methyl methacrylate monomer (MMA) double wide flanged the glass fiber-reinforced polymer(GFRP) pipe composite structures for the manhole raise. The evaluation of structural performance on this composite structure was conducted by the axial load, fatigue load, and ultimate load test. The assessment indicates that the MMA double wide flanged GFRP pipe composite structures was confirmed safety, durability and reliability in result as expected. It was found that this composite structure was able to short working times to around 30-50% and construction costs to around 10-23% with compare other construction methods. Also, environmental pollution and civil complaints will be prevented because there will be no longer any noises, vibrations, dust, or construction wastes.

히트파이프를 활용한 농업용 고효율난방기 및 스마트 제어시스템 (High-efficiency Agricultural Heater and Smart Control System Utilizing Heat Pipe)

  • 김응곤;임창균
    • 한국전자통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.1151-1158
    • /
    • 2017
  • 히트파이프 일체형 고효율 난방기는 겨울철 시설원예 내 작물생육에 필수인 난방장치와 배기열 회수기를 일체화하여 배기열이 외부로 배출되기 전 미사용 에너지를 재이용하는 장치이다. 시설원예, 유리온실 등 점검을 통해 우리나라 농업용 난방기의 문제점을 파악하였고, 개선방향을 찾아 시설원예 및 하우스에 맞는 최적화된 농업용 고효율난방기 및 스마트 제어시스템을 제안하였다.