• 제목/요약/키워드: glass penetration

검색결과 111건 처리시간 0.014초

수복방법에 따른 복합레진 및 글라스아이오노머 시멘트의 변연부 미세누출에 관한 연구 (A STUDY ON THE MICROLEAKAGE OF COMPOSITE RESIN AND GLASS IONOMER CEMENT WITH VARYING FILLING METHODS)

  • 황호길;박주식
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.174-186
    • /
    • 1996
  • The purpose of this study was to evaluate the adaptability to tooth structure of composite resin and glass ionomer cement according to filling methods. In this study. two class V cavities were prepared on the buccal and lingual surface of each tooth of forty extracted human premolars. and they were randomly assigned into 4 groups with 10 teeth. The cavities of each group were filled with the CLEARFIL FII self curing resin(Control Group), Z-100 light curing resin (Group 1). $Vitremer^{TM}$ light curing glass ionomer cement(Group 2) and Z-100 light curing resin over the $Vitremer^{TM}$ liner(Group 3). The specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ five hundred times. After thermocycling. specimens were immersed in 2% methylene blue solution and stored in 100% relative humidity at $37^{\circ}C$ for 24 hours. And then. the specimens sectioned buccolingually. Degree of dye penetration at tooth-restoration interfaces were examined by Tool maker's microscope(x 200) and Image analyzer. The results were as follows : 1. On the occlusal margin. among the experimental groups. the group 2 showed the highest dye penetration($2.40{\pm}0.68$) and the group 3 showed the lowest dye penetration($1.15{\pm}0.37$). There was significant difference among the experimental groups(p<0.001). 2. On the gingival margin, among the experimental groups, the group 1 showed the highest dye penetration($3.30{\pm}0.57$) and the group 2 showed the lowest dye penetration($1.65{\pm}0.49$). There was significant difference among the experimental groups(p>0.001). 3. About total degree of dye penetration, the group 1 showed the highest dye penetration($2.25{\pm}1.17$) and the group 3 showed the lowest dye penetration ($1.43{\pm}0.55$). There was significant difference among the experimental groups(p<0.001). 4. The sum of dye penetration at occlusal margin was less than gingival margin. There was significant difference between occlusal margin and gingival margin (p<0.001). The results showed that differences were more pronounced at the gingival margin. Composite restorations inserted over the glass-ionomer liner demonstrated significantly less leakage than single restoration that used composite resin or glass-ionomer cement.

  • PDF

Glass Ionomer Cement의 변록누출(邊綠漏出)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE OF GLASS IONOMER CEMENT)

  • 주광섭;유근원
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.101-106
    • /
    • 1981
  • The purpose of this study was to estimate the ability of the marginal fit of Glass ionomer cement. Using the human extracted teeth and 2% acqueous solution of methylene blue, the author investigated the marginal penetration of dye in restorative materials such as Amalgam, Hi-Pol, Glass ionomer cement, Estic microfill and Restodent. The results were as follows. 1. All filling materials showed some degree of marginal penetration. 2. Glass ionomer cement revealed nearly the same microleakage as Estic microfill and Hi-Pol, but showed inferior effect of the marginal seal as compared with Restodent. 3. It is appeared that Amalgam has more effective ability of the marginal fit than the others within a week.

  • PDF

충격기류 탈진방식 여과포집진장치에서 탈진조건 변화에 따른 국산유리섬유여과포의 성능시험 (Performance Test of Domestic Glass Fabric by varying cleaning conditions in a Pulse-Jet Cleaned Fabric Filter)

  • 박영옥;구철오;임정환;김영성;손재익
    • 한국대기환경학회지
    • /
    • 제10권3호
    • /
    • pp.183-190
    • /
    • 1994
  • Performance of domestic glass fabrics was tested in a Pulse- jet cleaned fabric filter under simulated coal combustion. Pulse Pressure were 2.5, 4.0kgf/$\textrm{cm}^2$ and pulse air nozzle diameter were 4.0, 6.0mm Pressure drop and penetration turned out to be low at small pulse air nozzle diameter and low pulse air pressure. Fractional penetration through the dust cake and fabric at face velocity of 1.7m/min was higher than that at face velocity of 1.0m/min. As a consequense, the performance of domestic glass fabrics was better with face velocity of less than 1.0m/min, pulse air pressure of 2.5 kgf/$\textrm{cm}^2$ and pusle air nozzle diameter of 4.0mm.

  • PDF

세라믹/유리섬유강화복합재 적층판의 고속충돌에 의한 파괴거동 (Fracture Mechanism of Ceramic/Glass-fiber-reinforced-composites Laminate by High Velocity Impact)

  • 정우균;이우일;김희재;권정원;안성훈
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.170-176
    • /
    • 2006
  • Multi-layered laminate made of ceramic/composite have been developed to prevent penetration by high velocity impact. In this study, three-layered plates consisted of 1) cover layer (glass fiber reinforced polymer), 2) $Al_{2}O_{3}$, ceramic plate, and 3) backing plate (glass fiber reinforced polymer) were fabricated with various conditions and tested for their ballistic protection characteristic. The ceramic composite laminates, with thin backing plate, were completely penetrated by armor piercing projectile. The plate with inserted rubber between ceramic and backing plate showed excellent ballistic protection, though completely penetrated by the second shoot.

수종(數種) 수복물(修復物)의 색소침투(色素浸透)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON PENETRATION OF DYE IN FILLING MATERIALS)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제4권1호
    • /
    • pp.29-34
    • /
    • 1978
  • The purpose of this study was to measure penetration of dye stuff(5% Methylene blue, Hematoxylin, Crystal violet and Safranin-O) on silicate cement, Adaptic, Hi-pol and unfilled resin. Each filling material was mixed on the mixing pad and the mixed material was inserted with condensation force of 500gr, 1000gr and 2000gr and without condensation force into preformed glass tube (10mm in diameter and 10mm in height). The specimen was stored in the air for 24 hours, then specimen was immersed in various dye solution (5% methylene blue, hematoxin, crystal violet and safranin-O) for different period of time (l hour and 24 hours). These dye-treated specimen was cut horizontally at the middle portion and the dye penetration in cut surface was measured. Following results were obtained. 1. Pentration of various dye was excessive in silicate cement with and without Condensation force. 2. There has been no evidence of dye penetration in unfilled resin. 3. Dye penetration occurced with in 1 hour period and the extending time didn't affect the dye penetration.

  • PDF

인공치관용 알루미나/지르코니아-유리 복합체의 기계적 및 광학적 특성 (Mechanical and optical properties of alumina/zirconia-glass dental crown composites)

  • 이득용;장주웅
    • 한국결정성장학회지
    • /
    • 제13권3호
    • /
    • pp.99-104
    • /
    • 2003
  • 용융침투법으로 알루미나/지르코니아-유리 복합체를 제조하여 지르코니아 첨가가 복합체의 기계적 및 광학적 특성과 유리 침투 kinetic에 미치는 영향을 조사하였다. 유리 침투시간이 증가할수록 침투깊이는 Washburn식에 의한 포물선관계로 증가하였으며 침투 상수인 K는 기공 크기의 함수로 지르코니아 첨가량이 증가할수록 기공 크기의 감소로 감소하였다. 지르코니아 양이 증가함에 따라 명도($L^*$)는 증가하지만 유리 침투 상수(K), 투과율(transmittance), 채도($C^*$)가 감소하였다. 지르코니아가 15 wt% 첨가될 때까지 알루미나/지르코니아-유리 복합체의 인성값 증가를 보였지만 기공률의 증가로 인하여 기계적 특성 향상에는 크게 기여하지 않았다.

Penetration Mechanisms of Ceramic Composite Armor Made of Alumina/GFRP

  • Jung, Woo-Kyun;Lee, Hee-Sub;Jung, Jae-Won;Ahn, Sung-Hoon;Lee, Woo-Il;Kim, Hee-Jae;Kwon, Jeong-Won
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권4호
    • /
    • pp.38-44
    • /
    • 2007
  • Combat vehicles are frequently maneuvered in battlefields when the lives of combatants are being threatened. These vehicles are important elements that influence the consequences of a battle. Their armor must be lightweight and provide excellent protection to ensure successful operations. Ceramic composite armor has recently been developed by many countries to fulfill these requirements. We reviewed previous research to determine an effective armor design, and then fabricated a composite armor structure using $Al_2O_3$ and glass fiber-reinforced polymer. Specimens were manufactured under controlled conditions using different backing plate thicknesses and bonding methods for the ceramic layer and the backing plate. The penetration of an armor-piercing bullet was evaluated from ballistic protection tests. The bonding method between the ceramic layer and the fiber-reinforced polymer influenced the ballistic protection performance. A bonding layer using rubber provided the best protection.

폴리에틸렌글리콜의 분자량에 따른 셀룰로스에서의 확산 거동 (The Effect of the Molecular Weight of Poly(ethylene glycol) on Diffusion through Cellulose)

  • 윤기종;우종형;서영삼
    • 한국염색가공학회지
    • /
    • 제16권1호
    • /
    • pp.48-52
    • /
    • 2004
  • Diffusion/penetration rates of finishing agents are not a major criterion in the design of low molecular weight finishing agents. However, in the case of polymeric finishing agents, high molecular weights result in large hydrodynamic volumes and diffusion/penetration of the finishing agent into the substrate may become a critical factor in the design of textile finishing agents. Thus the effect of the molecular weight of a model compound, polyethylene glycol, on its diffusion through a cellulose membrane or cotton fabric is studied. Diffusion experiments of polyethylene glycol of molecular weight 400, 1000, 2000, 4600, 8000, and 10000 through cellulose membrane or fabric was carried out in a glass U-tube diffusion apparatus and the half penetration times and the penetration coefficients were determined. Both the half penetration times and the penetration coefficients exhibited a significant change between molecular weight 2000 and 2500 as the molecular weight of polyethylene glycol increased, suggesting that there is a critical molecular weight above which diffusion/penetration becomes difficult. Based on this study on a model compound, it is suggested that polymeric textile finishing agents can be expected to exhibit similar behavior.

투명 방탄소재용 보로실리케이트 유리의 이온교환 강화 (Strengthening of Borosilicate Glass by Ion Exchange for Lightweight Transparent Bulletproof Windows Materials)

  • 심규인;엄형우;최세영
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.507-513
    • /
    • 2013
  • Transparent bulletproof windows play an important role in the munitions industry. The thickness of bulletproof windows including soda-lime silicate(SLS) glass, polyvinyl butyral, poly urethane, main defense(200MD), and safety film was reduced from 40mm to 29mm by adjustment of SLS glass laminated array. Borosilicate glasses generally have lower surface density and more excellent mechanical properties than SLS glass. Borosilicate glass was strengthened by ion exchange in the $KNO_3$ powder. The maximum mechanical properties were observed at $550^{\circ}C$ for 10min. The Vickers hardness, fracture toughness and 3-point bending strength of ion exchanged samples were about $775kg/mm^2$, $1.91MPa{\cdot}m^{1/2}$ and 764MPa each, which are about 27%, 149% and 249% higher than parent borosilicate glass, respectively. The penetration depth of K+ ion at $550^{\circ}C$ for 10min was $59.8{\mu}m$. As a result, the transparent bulletproof windows were predicted to be more lightweight by ion exchange of borosilicate glass. If the SLS glass for bulletproof windows is replaced by ion exchanged borosilicate glass, the bulletproof windows can be expected to be lightweight and thinner.

염 용액에서의 화학적 이온교환 강화유리에 관한 연구 (A Study on the Glass Strengthened in Salt Solution by Chemical Ion Exchange)

  • 이종근;김인섭
    • 한국세라믹학회지
    • /
    • 제24권4호
    • /
    • pp.335-342
    • /
    • 1987
  • There were several numbers of studies on chemically strengthening glass. Most of them were strengthened in molten salt bath below transformation range of glass. Apart from them, this study used solution hydration technique by Autoclave. After determining proper concentration of AgNO3 salt solution, experimental condition varied from 4hrs to 16hrs at relatively low temperature (180, 200, 220$^{\circ}C$). The results showed that the Soda-Lime-Silica glass could be strengthened by diffusion mechanism without influence of water above 15% salt solution. Because of Ag+ ion penetration in glass surface, yellow color appeared and decreased transmittance at visible range. Modulus of rupture was increased with the amount of exchange and brittleness was decreased.

  • PDF