• 제목/요약/키워드: glass fiber type

검색결과 218건 처리시간 0.032초

현무암 섬유 보강 폴리우레탄폼의 열적 성능 및 극저온 환경에서의 기계적 특성 평가 (Evaluation of Thermal Performance and Mechanical Properties in the Cryogenic Environment of Basalt Fiber Reinforced Polyurethane Foam)

  • 전성규;김정대;김희태;김정현;김슬기;이제명
    • 대한조선학회논문집
    • /
    • 제59권4호
    • /
    • pp.207-213
    • /
    • 2022
  • LNG CCS which is a special type of cargo hold operated at -163℃ for transporting liquefied LNG is composed of a primary barrier, plywood, insulation panel, secondary barrier, and mastic. Currently, glass fiber is used to reinforce polyurethane foam. In this paper, we evaluated the possibility of replacing glass fiber-reinforced polyurethane foam with basalt fiber-reinforced polyurethane foam. We conducted a thermal conductivity test to confirm thermal performance at room temperature. To evaluate the mechanical properties between basalt and glass-fiber-reinforced polyurethane foam which is fiber content of 5 wt% and 10 wt%, tensile and an impact test was performed repeatedly. All of the tests were performed at room temperature and cryogenic temperature(-163℃) in consideration of the temperature gradient in the LNG CCS. As a result of the thermal conductivity test, the insulating performance of glass fiber reinforced polyurethane foam and basalt fiber reinforced polyurethane foam presented similar results. The tensile test results represent that the strength of basalt fiber-reinforced polyurethane foam is superior to glass fiber at room temperature, and there is a clear difference. However, the strength is similar to each other at cryogenic temperatures. In the impact test, the strength of PUR-B5 is the highest, but in common, the strength decreases as the weight ratio of the two fibers increases. In conclusion, basalt fiber-reinforced polyurethane foam has sufficient potential to replace glass fiber-reinforced polyurethane foam.

사이징제에 따른 유리섬유/불포화 폴리에스터 복합재료의 계면 접착력과 기계적 물성 (Influence of Sizing Agent on Interfacial Adhesion and Mechanical Properties of Glass Fiber/Unsaturated Polyester Composites)

  • 박수진;김택진;이재락;홍성권;김영근
    • 폴리머
    • /
    • 제24권3호
    • /
    • pp.326-332
    • /
    • 2000
  • 유리섬유/불포화 폴리에스터 복합재료에서 섬유에 처리된 사이징제가 복합재료의 최종 물성에 미치는 영향을 상온에서의 접촉각 측정을 통해 고찰하였다. 본 연구에서는 폴리비닐알코올, 폴리에스터, 그리고 에폭시계 사이징제를 사용하여 유리섬유의 표면을 처리하였으며 각각의 물성을 비교하였다. 유리섬유의 접촉각은 증류수와 diiodomethane을 젖음액으로 사용하여 Washburn식을 기본으로 한 wicking법으로 측정하였다. 결과적으로 접촉각 측정에 의해 구한 표면자유에너지는 에폭시계 사이징제로 치리된 유리섬유에서 최대값을 나타내었다. 복합재료의 층간 전단 강도 (ILSS)와 파괴 인성 ( $K_{IC}$ )의 측정 결과로부터 사이징제의 처리에 따라 계면 결합력이 증진되며 결과적으로 복합재료의 기계적 강도가 증가함을 알 수 있었다. 이것은 복합재료에서 유리섬유의 표면 자유에너지 증가에 기인한다고 사료된다.

  • PDF

복합재료의 저속충격 특성 (Low-velocity Impact Characterization of Laminated Composite Materials)

  • 한지원
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.34-37
    • /
    • 2008
  • The composite materials are widely used in the many applications of industry as well as aerospace field because of their high specific stiffness and strength which benefits the material and provides potential energy savings. However, composite materials also have a low property about external applied impact. In this paper, impact tests were conducted on different sample types(glass, carbon and kevlar composite) to obtain information such as absorbed energy and composite deformation using an instrumented impact test machine (DYNATUP 8250). 3 type samples were compared to experimental results. The data from impact test provided valuable information between the different type samples by wet lay up. This paper shows results of that kevlar composite has larger absorption energy and deformation than others.

피로 실험에 의한 PSC 부재의 성능개선기법에 관한 연구 (A Study on Strengthening of PSC Beam by Fatigue Experiment)

  • 김현호;송재필;김기봉;정영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.165-172
    • /
    • 2003
  • The fatigue problem of Prestressed Concrete(PSC) bridges are more serious than the other type of concrete bridges, because the cross sectional area and self weight of PSC bridges are smaller. The endurance of strengthening methods for PSC bridges are tested in this study. Glass fiber sheeting and external post-tensioning methods were applied. 1/5 scale PSC beams were made for fatigue test, same as static test. The range of repeated load is from 10% to 80% of yielding load with sine curve. The experimental results show that the failure cycle of strengthened members are increased compare to non-strengthened members. The members strengthened with glass fiber show better enhancement in fatigue problem than the members strengthened with external post-tensioning method, though the adhesion of glass fiber and concrete is failed, as increase of crack. With these experimental results, it can be said that the strengthening methods used in this study are efficient at extending the life time of aged PSC bridges.

알루미나 단섬유 및 유리섬유 보강 청동기지 복합재의 마모특성 연구 (Tribological Properties of the Aluminum Short fiber and glass fiber Reinforced Tin-Bronze Matrix Composites)

  • 황순홍;안병길;이범주;최웅수;허무영
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1996년도 제24회 춘계학술대회
    • /
    • pp.13-19
    • /
    • 1996
  • The tribological properties of the aluminum short fiber and glass fiber reinforced tin-bronze matrix composites manufactured by vacuum hot pressing was studied. The effect of the composition and the relative density on the wear properties was examined by a reciprocal type tribo-test machine. The results were discussed by the observation of the microstructure of sintered specimen and worn surface observation using SEM and EDS. Addition of the fibers led to the wear resistance since the metal matrix was reinforced by the fibers. The reinforcement of the fiber seemed to be stronger as the distribution of the fibers was more uniform. Graphite also reduce the wear loss. The pores in the sintered composites seemed to play an important role to improve the wear resistance since the pores provide the places where the solid lubricants locate.

  • PDF

저변형률시험법에 의한 섬유강화 복합재료의 응력부식균열에 관한 연구 (A Study on Stress Corrosion Cracking of Fiber Reinforced Composite by Slow Strain Rate Test)

  • 임재규;최태수
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3433-3440
    • /
    • 1996
  • This paper was investigation of the stres corrosion cracking(SCC) mechanism and the properties of corrosion fracture surface of glass fiber reinforced plastics(GFRP) produced by hand lay up(HLU) method in synthetic sea water. Test material is GFRP, that was used vinylester type epoxy acrylate resin and an unsaturated polyester as the matrix and the chopped strand mat(CSM) type E-glss fiber as the reinforcement. The slow strain rate test(SSRT) was performed on dry, wet and saturated wet specimens in sea water. Here the pH concentration of synthetic sea water was 8.2 and the strain rate is 1 x $10^{-6}$($sec^{-1}$) and test temperature ranges varied from $-60^{\circ}C$ to $80^{\circ}C$. It could be confirmed the fact that wet specimens tested at a particular test temperature ranges were appeared the eviences of SCC such as con-planar, mirror and hackle zone. Moreover, SCC of GFRP in sea water was characterised by falt fracture surfaces with only small amounts of fiber pull-out, in partial.

인조광물섬유 산업에서 발생된 공기중 섬유의 크기 분포 (Size Distribution of Airborne Fibers in Man-made Mineral Fiber Industries)

  • 신용철;이광용
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.213-220
    • /
    • 2005
  • Penetration and health effect of fibers was related with their diameters and length. The purpose of this study is to characterize and compare the diameter and length of airborne man-made mineral fibers(MMMF) or synthetic vitreous fibers in the related industries. The average fiber length of the continuous filament glass, rock wool, refractory ceramic, and glass wool fibers production industries approximately 27, 28, 35, $50-105{\mu}m$. Airborne glass fibers were longest in all the type of MMMFs. The average diameters of airborne fibers generated from refractory ceramic, rock wool, glass wool, continuous filament glass fibers production industries were approximately 1.0, 1.6, 1.5-4 and $10{\mu}m$, respectively. The percentages of respirable fibers(<$3{\mu}m$) were 94% for RCFs, 73% for rock wool fibers, 61.0% for glass fibers, and 1.6% for filament glass fibers. The length of glass fibers were the longest in all types of fibers, and length of the others were similar. The refractory ceramic fibers were smallest in diameters and highest in fraction of respirable fibers.

유리와 탄소섬유로 제작된 하이브리드 FRP 로드의 인장특성에 관한 실험연구 (Tensile Properties of Hybrid FRP Rods with Glass and Carbon Fibers)

  • 유영준;박지선;박영환;김긍환
    • 콘크리트학회논문집
    • /
    • 제18권2호
    • /
    • pp.275-282
    • /
    • 2006
  • 최근 철근 콘크리트 구조물에서 철근의 부식문제를 근본적으로 해결하기 위한 대안으로 섬유강화폴리머(Fiber Reinforced Polymers, FRP)가 주목받고 있다. FRP는 철근에 비해 높은 비강도를 가지며, 무게가 가볍다. 특히 내부식성이 뛰어나 염해와 같은 열악한 환경에 특히 유용하다. 그러나 재료단가가 철근에 비해 높고, 장기거동에 대해 구축되어 있는 정보가 적으며 항복 거동을 보이는 철근과는 달리 취성파괴를 일으키기 때문에 FRP를 토목재료로 사용하려는 노력은 더디게 진행되고 있다. FRP 제작에 사용되는 섬유 중 유리섬유가 가장 경제적이지만 강성이 철근에 비해 대략 1/4 정도 밖에 되지 않아 휨부재에 사용될 경우 과도한 처짐 문제가 발생한다. 이에 본 연구에서는 유리섬유로 제작된 FRP(Glass Fiber Reinforced Polymer, GFRP) 로드(Rod)의 인장특성을 개선하고자 탄소와 유리섬유로 제작된 하이브리드 로드의 인장특성에 관한 연구를 수행하였다. 로드 제작에 사용되는 수지 종류와 배치 방법에 대해 변수를 설정하여 총 40개의 시편을 제작하여 인장실험을 실시하였다. 하이브리드 로드의 인장특성은 섬유가 혼합되지 않은 순수한 유리섬유와 탄소섬유로만 제작된 로드의 인장특성과 비교하였다. 실험 결과에 따르면 로드의 핵은 탄소섬유로, 외피는 유리섬유로 제작된 하이브리드 로드의 인장특성이 가장 우수하였다.

하이브리드 FRP 리바의 역학적 특성 (Mechanical Properties of Hybrid FRP Rebar)

  • 박찬기;원종필
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.58-67
    • /
    • 2003
  • Over the last decade fiber-reinforced polymer (FRP) reinforcement consisting of glass, carbon, or aramid fibers embedded in a resin such as vinyl ester, epoxy, or polyester has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. But reinforcing rebar for concrete made of FRP rebar has linear elastic behavior up to tensile failure. For safety a certain plastic strain and an elongation greater than 3% at maximum load is usually required for steel reinforcement in concrete structures. The same should be required for FRP rebar. Thus, the main object of this study was to develop new type of hybrid FRP rebar Also, this study was evaluated to the mechanical properties of Hybrid FRP rebar. The Manufacture of the hybrid FRP rebar was achieved by pultrusion, and braiding and filament winding techniques. Tensile and interlaminar shear test results of Hybrid FRP rebar can provide its excellent tensile strength-strain behavior and interlaminar stress-strain behavior.

노후 콘크리트포장 위에 덧씌운 섬유그리드 보강 아스팔트포장의 장기공용성 (Long-term Performance of Fiber Grid Reinforced Asphalt Pavements Overlaid on Old Concrete Pavements)

  • 이주명;백승범;이강훈;김조순;정진훈
    • 한국도로학회논문집
    • /
    • 제19권3호
    • /
    • pp.31-43
    • /
    • 2017
  • PURPOSES : The objective of this study is to verify the effect of fiber grid reinforcement on the long-term performance of asphalt pavement overlaid on old concrete pavement by performing field investigation, laboratory test, and finite element analysis. METHODS : The reflection cracking, roughness, and rutting of fiber grid reinforced overlay sections and ordinary overlay sections were compared. Cores were obtained from both the fiber grid reinforced and ordinary sections to measure bonding shear strength between the asphalt intermediate and asphalt overlay layers. Fracture energy, displacement after yield, shear stiffnesses of the cores were also obtained by analyzing the test results. Finite element analysis was performed using the test results to validate the effect of the fiber grid reinforcement on long-term performance of asphalt pavement overlaid on the old concrete pavement. The fatigue cracking and reflection-cracking were predicted for three cases: 1) fiber grid was not used; 2) glass fiber grid was used; 3) carbon fiber grid was used. RESULTS : The reflection-cracking ratio of fiber grid reinforced sections was much smaller than that of ordinary sections. The fiber grid reinforcement also showed reduction effect on rutting while that on roughness was not clear. The reflection-cracking was not affected by traffic volume but by slab deformation and joint movement caused by temperature variation. The bonding shear strength of the fiber grid reinforced sections was larger than that of the ordinary sections. The fracture energy, displacement after yield, and shear stiffnesses of the cores of the fiber grid reinforced sections were also larger than those of the ordinary sections. Finite element analysis results showed that fatigue cracking of glass or carbon fiber grid reinforced pavement was much smaller than that of ordinary pavement. Carbon fiber grid reinforcement showed larger effect in elongating the fatigue life of the ordinary overlay pavement compared to glass fiber grid reinforcement. The binder type of the overlay layer also affected the fatigue life. The fiber grid reinforcement resisted reflection-cracking and the carbon fiber grid showed the greater effect. CONCLUSIONS :The results of field investigation, laboratory test, and finite element analysis showed that the fiber grid reinforcement had a better effect on improving long-term performance of asphalt pavement overlaid on the old concrete pavement.