• Title/Summary/Keyword: glass fiber reinforced polymer bars

검색결과 52건 처리시간 0.023초

Post-heating behavior of concrete beams reinforced with fiber reinforced polymer bars

  • Irshidat, Mohammad R.;Haddad, Rami H.;Almahmoud, Hanadi
    • Structural Engineering and Mechanics
    • /
    • 제53권6호
    • /
    • pp.1253-1269
    • /
    • 2015
  • The present paper investigates the post heating behavior of concrete beams reinforced with fiber reinforced polymer (FRP) bars, namely carbon fiber reinforced polymer (CFRP) bars and glass fiber reinforced polymer (GFRP) bars. Thirty rectangular concrete beams were prepared and cured for 28 days. Then, beams were either subjected (in duplicates) to elevated temperatures in the range (100 to $500^{\circ}C$) or left at room temperature before tested under four point loading for flexural response. Experimental results showed that beams, reinforced with CFRP and GFRP bars and subjected to temperatures below $300^{\circ}C$, showed better mechanical performance than that of corresponding ones with conventional reinforcing steel bars. The results also revealed that ultimate load capacity and stiffness pertaining to beams with FRP reinforcement decreased, yet their ultimate deflection and toughness increased with higher temperatures. All beams reinforced with FRP materials, except those post-heated to $500^{\circ}C$, failed by concrete crushing followed by tension failure of FRP bars.

A study on load-deflection behavior of two-span continuous concrete beams reinforced with GFRP and steel bars

  • Unsal, Ismail;Tokgoz, Serkan;Cagatay, Ismail H.;Dundar, Cengiz
    • Structural Engineering and Mechanics
    • /
    • 제63권5호
    • /
    • pp.629-637
    • /
    • 2017
  • Continuous concrete beams are commonly used as structural members in the reinforced concrete constructions. The use of fiber reinforced polymer (FRP) bars provide attractive solutions for these structures particularly for gaining corrosion resistance. This paper presents experimental results of eight two-span continuous concrete beams; two of them reinforced with pure glass fiber reinforced polymer (GFRP) bars and six of them reinforced with combinations of GFRP and steel bars. The continuous beams were tested under monotonically applied loading condition. The experimental load-deflection behavior and failure mode of the continuous beams were examined. In addition, the continuous beams were analyzed with a numerical method to predict the load-deflection curves and to compare them with the experimental results. Results show that there is a good agreement between the experimental and the theoretical load-deflection curves of continuous beams reinforced with pure GFRP bars and combinations of GFRP and steel bars.

FRP 보강근을 사용한 콘크리트 보의 처짐예측 (Deflection Prediction of Concrete Beams Reinforced with Fiber Reinforced Polymer(FRP) Bars)

  • 김재생;서대원;한범석;안종문;신성우;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.114-117
    • /
    • 2006
  • Concrete beams reinforced with fiber reinforced polymer (FRP) bars exhibit large deflection and crack width as compared to concrete beams reinforced steel due to modulus of elasticity of FRP bars. Current design code for prediction and crack width developed in concrete structures reinforced with steel bars may not be used for concrete beams reinforced with FRP bars. Thus a number of researcher have attempted to propose modifications to the ACI 318 empirical equation for estimating the effective moment of inertia of reinforced concrete beams. Others used numerical method to calculate the deflection. The purpose of this paper is to evaluation of methods of ACI 440.1 R-01, ISIS Canada design manual, and others for predicting deflection for glass fiber reinforced polymer reinforced concrete beams.

  • PDF

폴리머콘크리트 박스 거어더의 구조적 거동 (Structural Behavior of Polymer Concrete Bos Girders)

  • 연규석;김광우;이윤수;김성순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.213-219
    • /
    • 1993
  • The box girder was developed using polymer concrete, box girder were made for flexural behavior evaluation. The box girder was reinforced with reinforcing steel bars and fiber glass roving cloths. Failure loads were 13.5 tons and 16.6tons for steel reinforced girder and fiber glass reinforced girder, respectively. Especially for the fiber glass reinforced girder, the shape was not changed even after failure. It is expected that application of this idea will be useful for developing under ground box, girder, utility tunnel, small stream bridge box, etc.

  • PDF

Efficient repair of damaged FRP-reinforced geopolymeric columns using carbon fiber reinforced polymers

  • Mohamed Hechmi El Ouni;Ali Raza;Khawar Ali
    • Structural Engineering and Mechanics
    • /
    • 제87권6호
    • /
    • pp.585-599
    • /
    • 2023
  • Geopolymer concrete (GC) can be competently utilized as a practical replacement for cement to prevent a high carbon footprint and to give a direction toward sustainable concrete construction. Moreover, previous studies mostly focused on the axial response of glass fiber reinforced polymer (glass-FRP) concrete compressive elements without determining the effectiveness of repairing them after their partial damage. The goal of this study is to assess the structural effectiveness of partially damaged GC columns that have been restored using carbon fiber reinforced polymer (carbon-FRP). Bars made of glass-FRP and helix made of glass-FRP are used to reinforce these columns. For comparative study, six of the twelve circular specimens-each measuring 300 mm×1200 mm-are reinforced with steel bars, while the other four are axially strengthened using glass-FRP bars (referred to as GSG columns). The broken columns are repaired and strengthened using carbon-FRP sheets after the specimens have been subjected to concentric and eccentric compression until a 30% loss in axial strength is attained in the post-peak phase. The study investigates the effects of various variables on important response metrics like axial strength, axial deflection, load-deflection response, stiffness index, strength index, ductility index, and damage response. These variables include concentric and eccentric compression, helix pitch, steel bars, carbon-FRP wrapping, and glass-FRP bars. Both before and after the quick repair process, these metrics are evaluated. The results of the investigation show that the axial strengths of the reconstructed SSG and GSG columns are, respectively, 15.3% and 20.9% higher than those of their original counterparts. In addition, compared to their SSG counterparts, the repaired GSG samples exhibit an improvement in average ductility indices of 2.92% and a drop in average stiffness indices of 3.2%.

콘크리트 강도가 GFRP 복합재료 보강근의 부착강도에 미치는 영향 (Effect of Concrete Strength on the Bond Strength of Glass Fiber Reinforced Polymer Bars)

  • 김태영;박지선;이정윤;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.189-192
    • /
    • 2005
  • Glass fiber reinforced polymer (GFRP) bars gain increasingly more attention as a reinforcing option for concrete because of their corrosion resistance and non-magnetism. GFRP reinforcement for concrete does not have the same shape as steel reinforcement. Therefore, the bond performance of FRP bars, unlike that of steel, is dependent on their design, manufacture and mechanical properties. This paper studied the effect of high strength concrete on the bond strength of GFRP bars. Twenty-nine specimens having different compressive strength of concrete were tested in order to examine the bond behavior of GFRP bars.

  • PDF

GFRP 복합재료 보강근의 부착강도 평가 (Bond Strength of Glass Fiber Reinforced Polymer Bars)

  • 김태영;박지선;이정윤;유영찬;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.290-293
    • /
    • 2006
  • Glass fiber reinforced polymer (GFRP) bars gain increasingly more attention in the civil engineering community. GFRP reinforcement for concrete does not have the same shape as steel reinforcement. Therefore, the bond performance of FRP bars, unlike that of steel, is dependent on their design, manufacture and mechanical properties. It was tested in order to examine the bond behavior of GFRP bars under different compressive strength of concrete. Test results showed that the bond strength of GFRP increased with the compressive strength of concrete.

  • PDF

GFRP 보강 내염성 콘크리트 보의 해양구조부재로서의 적용성 검토 (Study of Application of Salt Resistance Concrete Beam Reinforced with Glass Fiber Reinforced Polymer-Ribbed Bar as a Member of Marine Structure)

  • 김충호;황윤희
    • 한국해양공학회지
    • /
    • 제22권5호
    • /
    • pp.94-99
    • /
    • 2008
  • Three types of salt resistant concrete beams reinforced with glass fiber reinforced polymer-ribbed bars (GFRP-ribbed bars) were selected, and their applicable properties were investigated with the goal of improving the problem of capacity deterioration in marine structures due to sea water corrosion. In this study, the structural behaviors were similar to RC beams in relation to the development of the strength and stiffness up to the generation of the initial crack. After the growth of this initial crack, the structural properties decreased owing to a sudden loss of bond strength. Also these beams showed the trends of brittle failure. As a result, it was confirmed that a GFS beam replaced with Fly Ash (20%) and Silica Fume (5%) has the best application as a marine structural element.

GFRP Rebar의 부착성능에 관한 실험적 연구 (An Experimental Study on the Bond Characteristics of Glass Fiber Reinforced Polymer Rebar)

  • 박지선;유영찬;박영환;최기선;김형열;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.124-127
    • /
    • 2004
  • This study is to investigate the bond characteristics of glass fiber reinforced polymer(GFRP) reinforcing bars in concrete by pullout test experimentally. Three different types of GFRP bars with different surface deformations were considered in this study. Also, standard deformed steel reinforcing bar with or without epoxy-coating were included for the comparisons of bond strength. All test procedures including specimens preparation, test apparatus and measuring devices were made according to the recommendation of CSA(Canadian Standards Association) Standard S806-02. From the test results, it was found that small surface indentations contributed to increase the bond strength of GFRP bar significantly. Based on the limited test results till now, the bond strength of GFRP bar with sand-coated deformation commercially available in foreign market is around $80\%$ of that of steel deformed bars.

  • PDF

2방향 슬래브의 성능 향상을 위한 집중 배근된 FRP 바의 적용 (Application of Concentrated FRP Bars to Enhance the Capacity of Two-Way Slabs)

  • 이주하;양준모;윤영수
    • 콘크리트학회논문집
    • /
    • 제19권6호
    • /
    • pp.727-734
    • /
    • 2007
  • 철근과 fiber-reinforced polymer (FRP)의 물리적, 역학적 특성의 차이 및 슬래브 상부 보강재의 기둥 인접부 집중 배근, 그리고 기둥 인접부 슬래브에 강섬유 콘크리트 (SFRC)의 타설 등에 따른 2방향 슬래브의 펀칭 전단 거동에 대한 효과를 평가하였다. 펀칭 전단강도, 강성, 연성, 변형률 분포 그리고 균열 제어 성능 등을 파악하였다. 실험 결과 기둥 인접부의 슬래브에 집중 배근을 하거나 SFRC를 타설하는 것은 glass fiber-reinforced polymer (GFRP) 바로 보강된 슬래브의 펀칭 전단 거동을 향상시켰다. 기둥 인접 구역에 집중 배근된 슬래브의 실험 결과를 다양한 설계기준과 타 연구자에 의해 제안된 예측식과 비교하였으며, 집중 배근으로 인한 이점을 예측식에 반영할 수 있도록 집중 배근된 슬래브의 철근비를 산정하는 합리적인 방법도 제안하였다.