Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).
The electrolyte separator for thermal battery should be easily handled and loaded a large amount of the molten salt. Ceramic fibers, especially fibrous commercial glass filters were used as an electrolyte separator and the lithium based molten salts were infiltrated into the ceramic filters. The pore structures of the ceramic filter and the melting properties of the lithium salts affected to the electrolyte loading and leakage. During the infiltration, ions of $Li^+$ and $F^-$ in the molten salts were reacted with the glass fiber and caused to be weaken the fiber strength.
본 연구에서는 필터를 이용하여 가스상 황화합물들을 필터 방식으로 제거하는 특성을 비교 분석하고자 하였다. 이를 위해, 이산화황으로 대표되는 산화황화합물과 황화수소를 위시한 5가지 환원황화합물 ($H_2S$, $CH_3SH$, DMS, $CS_2$, 와 DMDS)을 동시에 함유한 표준가스를 준비하였다. 그리고 이 가스를 연구대상으로 정한 글래스파이버 필터에 흘려주면서, 필터 통과 유무에 따른 농도차를 분석하였다. 이러한 자료를 토대로 황성분들의 제거특성을 각각의 황성분에 대비하여 해석하였다. 그 결과에 의하면, 이산화황은 필터에 의해 거의 완전하게 제거되지만, 환원황성분들은 각자의 반응성에 따라 상당히 차별화된 결과를 보였다. 반응성이 가장 강한 황화수소는 60% 가까이 제거되었다. 그러나 이에 반해, 분자량이 큰 성분들(DMS, $CS_2$, DMDS)은 필터에 제거되지 않고 거의 통과하는 것으로 나타났다.
Electret filter is good enough to protect health and environment from air pollution. The reason why is gathering particles not only by mechanical mechanism but also by electrostatic attraction. Especially this filter is shown lower pressure drop than general mechanical filters as glass fiber. For making electret filter media using polypropylene meltblown(M/B) nonwoven, the nonwoven is charged with corona which was supplied high voltage DC, AC, and pulse with DC power. The electret filter media is tested with $0.3{\mu}m$ sodium chloride and dioctyl phthalate(DOP) aerosol. Results revealed that filtration performance of electret filter media increased as corona was applied with higher voltage and with AC power rather than DC, and fiber diameter was fine and uniform.
Fabric fibrous filter has been used in various industrial applications owing to the low cost and wide generality. However, the basic properties of fabric materials often limit the practical utilization including hot gas cleaning. This study attempts to find new coatings of porous fibrous filter media in order to overcome its insufficient thermal resistance and durability. Teflon was one of the plausible chemicals to supplement the vulnerability against frequent external thermal impacts. A foaming agent composed of Teflon and some organic additives was tentatively coated on the glass fiber mat. The present test Teflon foam coated filter was fount to be useful for hot gas cleaning, up to $250^{\circ}C$-$300^{\circ}C$. Close examination using XPS(X-ray Photoelectron Spectroscopy) and Contact angle proved the binding interactions between carbon and fluorine, which implies coating stability. The PTFE/Glass foam coated filter consisted of more than 95% (C-F)n bond, and showed super-hydrophobic with good-oleophobic characteristics. The contact angle of liquid droplets on the filter surface enabled to find the filter wet-ability against liquid water or oil.
대기중의 암모니아가스와 암모늄염의 필터포집법에 관하여 연구하였다. 표준가스 발생장치로 발생시킨 암모니아가스를 3% 붕산-25% 글리세린 혼합액이 스며든 유리섬유 필터에 포집하였다. pH조절법으로 발생시킨 암모니아가스와 대기중의 암모니아를 5회씩 포집하여 측정한 결과 포집효율은 각각 96.4${\pm}$ 2.15%와 97.4${\pm}$1.06%였다. 시판되는 유리섬유 필터 및 Polycarbonate 필터에 대하여 암모니아가스의 흡착 및 탈리현상을 검토한 결과 유리섬유 및 석영 섬유 필터에서는 암모니아가스의 흡착과 약간의 암모늄염이 탈리되었으나, Polycarbonate 필터는 대기중의 암모늄염을 포집하는데 적합한 것으로 판단되었다. 지름 47mm의 필터에 20l/min의 유량으로 60분동안 대기를 포집하여 인도페놀법에 의한 분광광도법으로 측정 할 경우, 측정가능한 암모니아가스의 최저농도는 0.83ppb (약 0.63$\mug$/$m^3$)이다. 이 방법은 종래의 용액포집법에 의한 분광광도 측정법에 비하여 감도가 20배나 높으므로 대기중의 암모니아 농도의 변화를 단시간(약 60분)내에 측정할 수 있다.
Analytical chemists frequently use filter papers during the course of experiments without any hesitation. However, the results of analysis could be deteriorated by the various ions which are extracted from filter papers. In some filter paper made for qualitative use, about $300{\mu}g$ sodium and many other cations were detected. Although the quantities of contaminants was low in the filter paper made for quantitative use, significant amount of Fe, Si, Al, Cu and Zn was detected as well as alkali element. Many cations and anions were also detected in the filtrate obtained from the glass fiber filter.
A new method for measuring fiber length and fiber coarseness was developed using image analysis technique. Measured fibers were transferred to a glass slide on a filter paper placed on a wire of the laboratory paper machine. After staining the fibers on the slide, mean fiber lengths and coarseness were measured by a commercial image analysis software, named KS400. The resultant data obtained from the image analysis displayed a close correlation with those from FS-200 and also showed excellent reproducibility as well as those from FS-200. The length of synthetic fibers over 10 mm long could be readily measured by this new analysis technique. Finally, a substantial improvement in precision for measuring fiber length and coarseness was made with less operator's effort for a given time.
Thermal desorption/gas chromatography/mass selective detection method using Tenax cartridges for the determination of gaseous polycyclic aromatic hydrocarbons(PAH) is described. Glass fiber filter can collect only PAH in particulate. Gaseous PAH may penetrate the filter. Glass cartridge packed Tenax-GC was uses fur adsorption of gaseous PAH. The air of inhalation zone was collected fur 2-10 hours. Cartridges were thermally desorbed in the reverse direction to sample flow. The desorption conditions were as follows; desorption temperature; $300^{\circ}C$; desorption time; 20min; column head pressure; 30psi; inlet split vent; closed during desorption.
메타바코딩을 이용한 환경 DNA 분석은 검출 감도가 높아 어류의 생물다양성 평가 및 멸종위기종의 검출에 유용한 기술이다. 이번 연구는 메타바코딩을 이용해 우리나라 담수어류를 대상으로 높은 검출 효율을 보일 수 있는 적합한 분석방법을 확인하기 위해 4가지 분석조건별, 즉 필터(cellulose nitrate filter, glass fiber filter), 추출 키트(DNeasy® Blood & Tissue Kit, DNeasy® PowerWater Kit), 프라이머 조합(12S rDNA, 16S rDNA) 그리고 PCR 방법(conventional PCR, touchdown PCR)로 나타나는 Operational Taxonomic Units(OTUs) 수와 종 조성을 비교하였다. Glass fiber filter와 DNeasy® Tissue & Blood Kit를 이용해 추출한 시료는 12S rDNA와 16S rDNA 프라이머 조합에서 담수어류 OTUs가 가장 많이 검출되었다. 모든 분석조건 중 프라이머 조합에서만 조기어강(Class Actinopterygii) 평균 OTUs 수에서 통계적으로 유의한 차이를 보였고(Non-parametric Wilcoxon Signed Ranks Test, p=0.005), 담수어류 평균 OTUs 수는 유의하지 않았다. 종 조성 비교 결과 역시 프라이머 조합에서 유의한 차이를 보였고(PERMANOVA, Pseudo-F=6.9489, p=0.006), 나머지 분석조건에서는 유의한 차이를 보이지 않았다. NMDS 분석 결과 종 조성은 유사도 65% 기준에서 프라이머 조합에 따라 묶였고, 16S rDNA 프라이머 세트는 주로 멸종위기종인 모래주사(Microphysogobio koreensis), 꼬치동자개(Pseudogobio brevicorpus)가 기여하였고, 12S rDNA 프라이머 세트는 주로 일반종인 피라미(Zacco platypus), 꺽지(Coreoperca herzi) 등이 기여한 것으로 나타났다. 본 연구는 국내 하천에서 채취한 시료에 대한 메타바코딩을 이용한 종 다양성 분석의 기초정보를 제공한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.