Development of glass bulb for sprinkler head system (스프링클러용 유리발브의 개발)

  • Kim, Byung-Cheol;Joung, Hoon-Choul;Seo, Yo-Won;Myung, Young-Sup
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.144-147
    • /
    • 2008
  • A glass bulb is the most reliable and simplest device for a fire sprinkler head system. We had developed an accurate glass bulb. The glass bulb is composed with a glass ampoule, liquid filled within the ampoule and an air bubble in the liquid. The first step of the development was to establish a stable mass production system for uniform glass ampoule. The second step is to optimize the composition of the liquid and the size of the bubble. It was also a difficult problem to devise manufacturing process to form uniform bubble size. The final step for the development is to control the mechanics for glass breaking by surface treatment for the glass bulb.

  • PDF

The Characteristics of Al Thin Films by Vacuum Evaporation for Bulb Reflector (전구 Reflector용 진공증착 Al박막의 특성)

  • 김동구;김경남;김석기;구경완;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.688-691
    • /
    • 1999
  • Light was of electric lamp was reflected by bulb reflector. In order to improve the efficiency of the electric lamp. it is inevitable that lamp, it is inevitable that improve the reflectance of bulb reflector. Important factors that affect the reflectance of bulb reflector is working pressure, distance between evaporation source to substrate, the situation of surface of glass. etch rate of glass, etc. In this paper. confirmed the effect of etching, working pressure etc. , and its effect for the reflectance of bulb reflector. Especially, concentration of HF in the etching solution and etching time is to be importnace for characteristic of bulb reflector.

  • PDF

Comparative Study of Fluidized Bed-type and Assmann Psychrometer (유동층습도계와 아스만습도계의 비교 연구)

  • 강희찬;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

Recent Developments in Reducing Bulkiness of CRT Glass Bulbs

  • Sugawara, Tsunehiko;Shimizu, Naoya;Murakami, Toshide
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.359-363
    • /
    • 2002
  • Several innovations for reducing the bulkiness of glass bulbs for flat and large CRTs have been made and further technologies are being developed by using material and structural approaches. The integrated glass technology based on these innovations will provide a lightweight shallow glass bulb for the realization of a half- depth CRT.

  • PDF

Elastic-plastic Contact Stress Analysis of CRT Glass Bulb (CRT 글래스 벌브의 탄소성 접촉 응력 해석)

  • Kang, Dae Jin;Shin, Woon Seo;Song, Chang Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.145-151
    • /
    • 1997
  • In this paper, we discuss the cathode ray tube(CRT) glass bulb stress and sagging recovery by the contact band pressure using finite element method. We analyzed the band pressure and stress using contact element method between band and bulb before and after banding process which was conducted to decrease the stress concentration using finite element method, and calculated sagging recovery. The analysis results were confirmed by experiments using strain gauge and sagging recovery test apparatus.

  • PDF

Cause Investigation and Verification of Fire Accidents for Road and Street Lighting (가로등 화재사고의 원인규명과 검증)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Jong-Min;Kim, Young-Seok;Kim, Myoung-Soo;Kim, Hyeok-Soo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • This paper carried out a variety of analysis for a finding out the causes of fire on the street lamp. The glass bulb of 250W metal-halide(MH) lamps attached with the impurities rose the temperature by at $410.4^{\circ}$ in normal condition. Therefore, a lamp apparatus is needed the improvement for ventilation and the protection against dust. The heat of MH lamps is diffused through out the luminous tube, a glass bulb, and apparatus by degrees. The accident cause of the lamp is presumed that the accumulated heat by deposits of the inner part. It will be recommended the improvement of the structure that aren't the external impurity and accumulated heat in the MH lamps set.

  • PDF

Software Development for Glass-Bulb Automatic Design Integrated System Using Design Axiom (설계공리를 이용한 유리벌브 제품설계 자동화 시스템 구축)

  • Do, Sung-Hee;Park, Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1333-1346
    • /
    • 1996
  • As the automation system in manufacturing field works more efficientely, the automation scheme is applied to many areas. In order to reduce the entire manufacturing, cost the design process must be automated. However, design process is so complicated, it is very difficult to construct the design automation system. The axiomatic approach to design provides a general theoretical framework for all design fields, including mechanical design. The key concepts of axiomatic design are : the existence of domains, the characteristic vectors within the domains that can be decomposed into hierarchies through zigzagging between the domains, and the design axioms. Using this approach, the glass bulb design process was analyzed and the design automation software was developed. Through menu display, a user can select or furnish the design input and generate the drawing with ease.

An Experimental Study on the Lens Surface Temperature Distribution of P/C Headlamp Using the Three Category of H4 Halogen Bulbs (PIC 렌즈 전조등 렌즈면의 온도분포에 관한 실험적 연구)

  • 박경석;강병도
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.158-165
    • /
    • 2002
  • This Paper deals with the headlamp lens surface temperature distribution of p/c headlamp using the three categories of H4 halogen bulbs. Glass is gradually replaced by P/C for the lens material off vehicle headlamp due to the weight reduction and stream lined body of a vehicle. With this trend, the newly established standards for a headlamp with a P/C lens in Europe requires that the heat generated by a bulb should not distort the lens surface. Also the requirements fur the bulb of a headlamp are being enforced in U.S.A & Europe. However, such requirements are not established yet in Korea. By using three kinds (60/55w, 100/90w, 130/90w) of H4 halogen bulbs in this experiment, the surface temperature distribution and Max. temperature on the lens were measured. The results of this study implies the necessity of requirement fur the bulb off headlamp.

Development of glass bulb as a fire detecting element. (화재감지 감열체로서 유리벌브의 양산화 개발)

  • Kim, Byung-Cheol;Joung, Hoon-Choul;Seo, Yo-Won;Kim, Yong-Kyu
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.188-193
    • /
    • 2009
  • 유리벌브는 다양한 자동 소화장치 또는 시설에 신뢰성이 높은 감열체로서 각광받고 있다. 당사는 최근 작동온도가 매우 균일하고 하중강도가 우수한 유리벌브를 개발하였고 양산화에도 성공하였다. 본 논문에서는 당사가 개발한 유리벌브의 품질특성을 소개하고자 한다. 특히 본 연구에서는 화재 감지용 감열체로서 유리벌브의 주요 특성치인 반응시간지수 (RTI)에 대해 비중 있는 연구를 진행하여 유리벌브의 RTI를 결정하는 주요 변수들을 도출하고, 이를 설계에 응용하여 유리벌브의 RTI를 조절할 수 있는 툴로서 개발하였다.

  • PDF

Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp (백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.