• 제목/요약/키워드: glass architecture

검색결과 302건 처리시간 0.031초

염료감응태양전지(DSC)를 적용한 Glazing의 구성에 따른 단열 및 전기 성능 분석 (A Study on Thermal & Electrical Performance of Glazings with DSC modules)

  • 김지성;박세현;강준구;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.158-163
    • /
    • 2011
  • Recently, more attention has been paid to DSC(Dye-sensitized Solar Cell) with the potential of glazing applications. The aim of the study is to analyze thermal and electrical performance according to composition of glazing with DSC. For this study, the electrical and thermal performance of glazing with DSC modules were measured and their result were compared. The measurement were performed according to the KS L2525 and with a solar simulator of DSC modules. The result show that the U-value of the DSC double glazings with clear glass and low-e glass were 2.78 $W/m^2K$ and 1.70 $W/m^2K$, respectively. The electrical measurement indicated that the electrical efficiency of the DSC double glazings with clear glass and low-e glass decreaced by 9.9% and 13.3%, respectively, compared to the DSC medules electrical performance.

  • PDF

반복 충격이 유리섬유 강화 폴리우레탄 폼의 기계적 성능에 미치는 영향 (Effect of Repetitive Impacts on the Mechanical Behavior of Glass Fiber-reinforced Polyurethane Foam)

  • 김명성;김정현;김슬기;이제명
    • 한국해양공학회지
    • /
    • 제33권1호
    • /
    • pp.85-91
    • /
    • 2019
  • In a cryogenic storage structure, the insulation system is in an environment in which fluid impact loads occur throughout the lifetime of the structure. In this study, we investigated the effect of repetitive impact loading on the mechanical performance of glass fiber-reinforced polyurethane foam. The repeated impact loading test was conducted in accordance with the required impact energy and the required number of repetitive impacts. The impact behavior of glass fiber-reinforced polyurethane foam was analyzed in terms of stress and displacement. After the impact test, the specimen was subjected to a compression test to evaluate its mechanical performance. We analyzed the critical impact energy that affected mechanical performance. For the impact conditions that were tested, the compressive strength and elastic modulus of the polyurethane foam can be degraded significantly.

실측실험과 3차원 정상상태 열전달 해석을 통한 발열유리의 온도 및 전열량 분석 (Analysis of Temperature and Total Heat of Heated Glass through Experimental Measurement and Three-Dimensional Steady-State Heat Transfer Analysis)

  • 이도형;윤종호;오명환
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.111-116
    • /
    • 2015
  • Heat loss from windows and condensation occuring on its surface due to its lower insulation value causes much discomfort to occupants. In this study, Heated glass was used to make a basic study on prevention of condensation on glass surface for its heating functionality through experimental measurement and simulation analysis of total heat flux on the interior and exterior surface of glass. Error between experimental results and three dimensional steady-state heat transfer analysis were caused firstly, beacuse in the experimental chambers, cold chamber and steady temperature and humidity chamber, air temperature setting was not constant but rather ON/OFF control, and secondly, due to error rate in heat flux meter due to heat flux direction even in stable conditions.

에너지절약형 이중외피 창호의 기본채광 성능 (Daylighting Performance of a New-Developed Energy Efficient Double-Skin Window System)

  • 박종명;김재훈;최진우;임홍수;김곤
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.117-122
    • /
    • 2008
  • The apartment will be much more convenient than the other one in the application of green technologies, providing the merits by mass production. For example, pre-manufactured building materials can be effectively adapted to the formation of buildings. Recently, the form of double-enveloped window system has been developed for the purposed of minimizing energy loss occurred around windows. On the other hand, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. A various types of glass can be applied to the window system and it plays a critical role in the determination of inner visual environment. For the purpose of verifying the potential of its daylighting, a mock-up model has been constructed and tested. The refurbished version of conventional window shows its illuminated characteristics. Clear and Low-e glass have been adapted for window area and daylighting ratio has been compared in both test cells.

  • PDF

Development of New Detachable Connection for Glass Fiber Reinforced Polymer Considering of Short and Long-Term Behavior

  • Park, Don-U;Hwang, Kyung-Ju;Knippers, Jan
    • 한국공간구조학회논문집
    • /
    • 제7권3호
    • /
    • pp.141-151
    • /
    • 2007
  • The appearance of many Glass Fiber Reinforced Plastic (GFRP) constructions look like ordinary steel construction, because GFRP has been imitated by the same way with the traditional steel's cross section as well as connection system. In terms of detachable connection, there was not enough appropriate option of GFRP connection, such as a traditional bolt connection for steel and wood structures. Most of all, from material characteristic of GFRP related to the deficient ductility, the shearstress principle of GFRP s not proper for the material property, which causes ineffective and not economic application of material. With this research problem, the innovative and detachable onnection system, which is more considered with appropriate material characteristic for FRP, is developed. Not only short time but also long time research with various connection variations is carried out.

  • PDF

현대 실내 건축에 있어서 유리가 미친 심리적 영향에 관한 연구 -Mies van der Rohe의 주택을 중심으로- (A Study on the Psychological effects of glass in Modern Interior Architecture -focused on Mies van der Rohes House Projects-)

  • 문정묵
    • 한국실내디자인학회논문집
    • /
    • 제25호
    • /
    • pp.103-110
    • /
    • 2000
  • The material world around human is normally composed of opaque one, with which human has made the spaces. The opaque material to make space has played a role to control the relationship among people and has produced socio-cultural things since the history started. The opening of opaque material(wall) connects one space with the other. Therefore, the meaning of opening is a connection among people who are in different spaces in terms of sociology. In conjunction with this, socio-cultural situation has been deployed differently. In the traditional european domestic space, the glass has been applied to this opening since they found the glass. It disconnects two spaces physically but connects them visually. Therefore, without blocking the opening visually, the glass became to protect people with their interior space from outside environment. The important thing is that the application of the glass in a building had been restricted because of opening size. However, after Industrial Revolution with the advanced technology of architecture, the glass came to be applied to the building and it became widen. So, the concept of glass window became to be the one of glass wall. This change made a transformation of visual character between two spaces which are separated with glass wall. This means that the glass wall gave two directional visibility while the glass window gave one directional visibility from inside to outside of space. This is because the amount of the natural light to the interior space increased due to widen glass in a space. This gave a change of visual authority and the space of surveillance(interior space) became to the one of communication. The space of surveillance, Michel Foucault mentioned in his book surveillance and punishment, is a very private one that is not visually permeable from the people outside, while the space of communication is a public one which needs other eyes. In the space of publicity, there needs a rationality, morality and ethics because of public surveillance and in the space of privacy, there restores a desire for sex and assaults.

  • PDF

투명성 효과를 위한 재료의 특성 및 적용 방법 (An Analysis of Application of Transparent Materials in Interior Space)

  • 정필영
    • 한국디지털건축인테리어학회논문집
    • /
    • 제7권2호
    • /
    • pp.19-24
    • /
    • 2007
  • This study attempts to examine and to analyze the characteristics of transparent materials and its methods to apply in space. the ability to see through a physical element, whether it is clear glass, sandblasted acrylic, or a delicate fabric, can have a dramatic and sensory effect on the overall perception of a space. The various range of Transparent materials and product in glass, plastic, fabric, and grid now gives us the potential to maximize the flow of light in our enclosed space. This research will explore how transparent, translucent, and semi-opaque elements can be used within the interior with full range of see-through materials. The transparent materials can be divided in two level - as structural elements and as stylish accessories. A glass partition or floor, metal mesh stairs can create divisions or link one space to another while maintaining effective levels of natural light. there is also various level of products from glass chair to basin. With the enthusiasm for using transparent materials, transparent materials will be more decorative and powerful application while still maximize the highest possible flow of light.

  • PDF

유리 색에 따른 아트리움 실내공간의 채광분위기 평가 (A Study on The Evaluation of Interior Atmosphere in Atrium with Glass Colour)

  • 정유근;김찬수;김정태
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.51-58
    • /
    • 2003
  • This Study aims to evaluate the interior atmospheres of atrium by glass colours. For the purpose, the 1/50 scale model of one-sided atrium was made and images of interior atmospheres were pictured under clear sky conditions. And then, questionnaire surveys were conducted on K university students in department architecture engineering. The survey results were analyzed by SPSS program. Frequency and correlation analysis were performed. As results, clear glass is chosen as the most preferred glass colour in any seasons. And, green and blue glasses are preferred in the order. And then, it is revealed that the main variables affecting satisfaction of interior atmospheres are a little changed by thermal senses of seasons. These variables are "bright", "neat", "warm", "comfort", "stable", "active", "static", "elegant" and "cool" through correlation analysis.

LNGC 2차 방벽에 적용된 Aramid 섬유의 Weibull 통계 분석을 이용한 피로특성 평가 (Estimation of Fatigue Characteristics Using Weibull Statistical Analysis with Aramid Fiber on LNGC Secondary Barrier)

  • 박진형;오동진;김민규;김명현
    • 대한조선학회논문집
    • /
    • 제54권5호
    • /
    • pp.415-420
    • /
    • 2017
  • Insulation systems in Liquefied Natural Gas Carriers (LNGC) are vulnerable to sloshing impact and fatigue loads because of waves. If gas leaks into the primary barrier, the Flexible Secondary Barrier (FSB) prevents the leakage of gas in this system. Fatigue strength of the FSB largely depends on the behavior of composite materials. In this study, a new system is applied to the FSB using aramid fiber to improve the fatigue strength of the secondary barrier, with the intention of replacing conventional E-glass fibers. The manufacturing method involved varying the ratio of the aramid fiber to the E-glass fiber for optimum design of the FSB. The fatigue tests results of the secondary barrier using aramid fiber were superior to that using E-glass fiber. The statistical analysis is performed to obtain the fatigue test results and estimate the probability of failure as well as the design guideline of LNGC secondary barriers.

아트리움형 공간 내 수직온도차에 따른 온열환경 (Indoors Thermal Environment by Vertical Temperature Differences in Atrium Space)

  • 위승환;이종기;김석환;김수민
    • 한국가구학회지
    • /
    • 제25권2호
    • /
    • pp.122-128
    • /
    • 2014
  • Recently, many studies have conducted to satisfy a physical need of human between environment of light on space, so an atrium structure has been applied to cultural complex. However, this structure brings about many problems such as overheating in summer, excessive vertical temperature differences, condensation, diffusion of noise, effect of echo, and withering landscapes. Especially, in this research, thermal comfort by difference of vertical temperature in the space of atrium and the optical characteristics of glass skins of the atrium could be remarkably effected by solar flux entering indoors.

  • PDF